Joshua M. Rosvold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Joshua M. Rosvold has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Cyril B. Frank
University of Calgary
5 shared publications - Nigel G. Shrive
University of Calgary
5 shared publications - Mohammad Atarod
McCaig Institute for Bone and Joint Health, Faculty of Medicine, University of Calgary, Calgary, Alberta, Canada
4 shared publications - Bryan J. Heard
Section of Orthopaedic Surgery, Department of Surgery, University of Calgary, Calgary, Canada
1 shared publication C. B. Frank
Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
1 shared publicationD. T. Corr
Department of Civil Engineering, Schulich School of Engineering, University of Calgary, c/o McCaig Institute for Bone and Joint Health, 3330 Hospital Drive Northwest, Calgary, AB, T2N 4N1, Canada
1 shared publication
Latest Publications
- 12 February 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (5) , 1121-1132
A Novel Testing Platform for Assessing Knee Joint Mechanics: A Parallel Robotic System Combined with an Instrumented Spatial Linkage
Assessing joint function following trauma and its inter-relation with degenerative changes requires an understanding of the normal state of structural loading in the joint. Very few studies have attempted to reproduce joint specific in vivo motions in vitro to quantify the actual loads carried by different tissues within the knee joint. The most significant challenge in this area is the very high sensitivity of the loads in joint structures to motion reproduction accuracy. A novel testing platform for assessing knee joint mechanics is described, comprised of a highly accurate (0.3 ± 0.1 mm, 0.3 ± 0.1°) six-degree-of-freedom (6-DOF) instrumented spatial linkage (ISL) for in vivo joint kinematic assessments and a unique 6-DOF parallel robotic manipulator. A position feedback system (ISL and position controller) is used for accurate reproduction of in vivo joint motions and estimation of “in situ” joint/tissue loads. The parallel robotic manipulator provides excellent stiffness and repeatability in reproducing physiological motions in 6-DOF, compared to the commonly used serial robots. The position feedback system provides real-time feedback data to the robot to reproduce in vivo motions and significantly enhances motion reproduction accuracy by adjusting for robot end-effector movements. Using this combined robot-ISL system, in vivo motions can be reproduced in vitro with very high accuracy (0.1 mm, 0.1°). Our results indicate that this level of accuracy is essential for meaningful estimation of tissue loads during gait. Using this novel testing platform, we have determined the normal load-carrying characteristics of different tissues within the ovine knee joint. The application of this testing system will continue to increase our understanding of normal and pathological joint states.
- 12 February 2014
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 42 (5) , 1121-1132
A Novel Testing Platform for Assessing Knee Joint Mechanics: A Parallel Robotic System Combined with an Instrumented Spatial Linkage
Assessing joint function following trauma and its inter-relation with degenerative changes requires an understanding of the normal state of structural loading in the joint. Very few studies have attempted to reproduce joint specific in vivo motions in vitro to quantify the actual loads carried by different tissues within the knee joint. The most significant challenge in this area is the very high sensitivity of the loads in joint structures to motion reproduction accuracy. A novel testing platform for assessing knee joint mechanics is described, comprised of a highly accurate (0.3 ± 0.1 mm, 0.3 ± 0.1°) six-degree-of-freedom (6-DOF) instrumented spatial linkage (ISL) for in vivo joint kinematic assessments and a unique 6-DOF parallel robotic manipulator. A position feedback system (ISL and position controller) is used for accurate reproduction of in vivo joint motions and estimation of “in situ” joint/tissue loads. The parallel robotic manipulator provides excellent stiffness and repeatability in reproducing physiological motions in 6-DOF, compared to the commonly used serial robots. The position feedback system provides real-time feedback data to the robot to reproduce in vivo motions and significantly enhances motion reproduction accuracy by adjusting for robot end-effector movements. Using this combined robot-ISL system, in vivo motions can be reproduced in vitro with very high accuracy (0.1 mm, 0.1°). Our results indicate that this level of accuracy is essential for meaningful estimation of tissue loads during gait. Using this novel testing platform, we have determined the normal load-carrying characteristics of different tissues within the ovine knee joint. The application of this testing system will continue to increase our understanding of normal and pathological joint states.
- 15 May 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (10) , 2067-2076
Functional Activity of the Anterior and Posterior Cruciate Ligaments Under In Vivo Gait and Static Physiological Loads
- 15 May 2013
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 41 (10) , 2067-2076
Functional Activity of the Anterior and Posterior Cruciate Ligaments Under In Vivo Gait and Static Physiological Loads
- 1 May 2011
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 133 (5) , 054501
Technical Issues in Using Robots to Reproduce Joint Specific Gait
Reproduction of the in vivo motions of joints has become possible with improvements in robot technology and in vivo measuring techniques. A motion analysis system has been used to measure the motions of the tibia and femur of the ovine stifle joint during normal gait. These in vivo motions are then reproduced with a parallel robot. To ensure that the motion of the joint is accurately reproduced and that the resulting data are reliable, the testing frame, the data acquisition system, and the effects of limitations of the testing platform need to be considered. Of the latter, the stiffness of the robot and the ability of the control system to process sequential points on the path of motion in a timely fashion for repeatable path accuracy are of particular importance. Use of the system developed will lead to a better understanding of the mechanical environment of joints and ligaments in vivo.
- 1 May 2011
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 133 (5) , 054501
Technical Issues in Using Robots to Reproduce Joint Specific Gait
Reproduction of the in vivo motions of joints has become possible with improvements in robot technology and in vivo measuring techniques. A motion analysis system has been used to measure the motions of the tibia and femur of the ovine stifle joint during normal gait. These in vivo motions are then reproduced with a parallel robot. To ensure that the motion of the joint is accurately reproduced and that the resulting data are reliable, the testing frame, the data acquisition system, and the effects of limitations of the testing platform need to be considered. Of the latter, the stiffness of the robot and the ability of the control system to process sequential points on the path of motion in a timely fashion for repeatable path accuracy are of particular importance. Use of the system developed will lead to a better understanding of the mechanical environment of joints and ligaments in vivo.