Håkan Ahlström
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Håkan Ahlström has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Joel Kullberg
Radiology, Department of Surgical Sciences, Uppsala University, Uppsala, SE-75185, Sweden
5 shared publications - Lars Johansson
Antaros Medical AB, Gothenburg, Sweden
5 shared publications Joel Kullberg
Section of Radiology, Department of Surgical Sciences, Uppsala University, Uppsala, Sweden; Antaros Medical AB, BioVenture Hub, Mölndal, Sweden
3 shared publications- Lars Lind
Uppsala University
3 shared publications Lars Lind
Department of Medical Sciences, Uppsala University, Uppsala, Sweden
2 shared publications- Peter Lind
Department of Medical Sciences, Occupational and Environmental Medicine, Uppsala University, Uppsala, Sweden
2 shared publications
Latest Publications
- Open Access
- 1 February 2021
- Published by Elsevier in Nutrition, Metabolism and Cardiovascular Diseases
- Vol. 31 (2) , 532-539
Cardiovascular-related proteins and the abdominal visceral to subcutaneous adipose tissue ratio
- 1 February 2021
- Published by Elsevier in Nutrition, Metabolism and Cardiovascular Diseases
- Vol. 31 (2) , 532-539
Open AccessCardiovascular-related proteins and the abdominal visceral to subcutaneous adipose tissue ratio
- Open Access
- 1 October 2019
- Published by Elsevier in Nutrition, Metabolism and Cardiovascular Diseases
- Vol. 29 (10) , 1077-1086
Relationship between endothelium-dependent vasodilation and fat distribution using the new “imiomics” image analysis technique
- 1 October 2019
- Published by Elsevier in Nutrition, Metabolism and Cardiovascular Diseases
- Vol. 29 (10) , 1077-1086
Open AccessRelationship between endothelium-dependent vasodilation and fat distribution using the new “imiomics” image analysis technique
- Open Access
- 1 May 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 58, 135-142
MRI estimates of brown adipose tissue in children – Associations to adiposity, osteocalcin, and thigh muscle volume
- 1 May 2019
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 58, 135-142
Open AccessMRI estimates of brown adipose tissue in children – Associations to adiposity, osteocalcin, and thigh muscle volume
- Open Access
- 24 January 2018
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 52 (1) , 90-97
MRI and 11 C acetate PET/CT for prediction of regional lymph node metastasis in newly diagnosed prostate cancer
Background: The aim of the study was to examine the value of quantitative and qualitative MRI and 11 C acetate PET/CT parameters in predicting regional lymph node (LN) metastasis of newly diagnosed prostate cancer (PCa). Patients and methods: Patients with intermediate (n = 6) and high risk (n = 47) PCa underwent 3T MRI (40 patients) and 11 C acetate PET/CT (53 patients) before extended pelvic LN dissection. For each patient the visually most suspicious LN was assessed for mean apparent diffusion coefficient (ADCmean), maximal standardized uptake value (SUVmax), size and shape and the primary tumour for T stage on MRI and ADCmean and SUVmax in the index lesion. The variables were analysed in simple and multiple logistic regression analysis. Results: All variables, except ADCmean and SUVmax of the primary tumor, were independent predictors of LN metastasis. In multiple logistic regression analysis the best model was ADCmean in combintion with MRI T-stage where both were independent predictors of LN metastasis, this combination had an AUC of 0.81 which was higher than the AUC of 0.65 for LN ADCmean alone and the AUC of 0.69 for MRI T-stage alone. Conclusions: Several quantitative and qualitative imaging parameters are predictive of regional LN metastasis in PCa. The combination of ADCmean in lymph nodes and T-stage on MRI was the best model in multiple logistic regression with increased predictive value compared to lymph node ADCmean and T-stage on MRI alone.
- 24 January 2018
- Published by Walter de Gruyter GmbH in Radiology and Oncology
- Vol. 52 (1) , 90-97
Open AccessMRI and 11 C acetate PET/CT for prediction of regional lymph node metastasis in newly diagnosed prostate cancer
Background: The aim of the study was to examine the value of quantitative and qualitative MRI and 11 C acetate PET/CT parameters in predicting regional lymph node (LN) metastasis of newly diagnosed prostate cancer (PCa). Patients and methods: Patients with intermediate (n = 6) and high risk (n = 47) PCa underwent 3T MRI (40 patients) and 11 C acetate PET/CT (53 patients) before extended pelvic LN dissection. For each patient the visually most suspicious LN was assessed for mean apparent diffusion coefficient (ADCmean), maximal standardized uptake value (SUVmax), size and shape and the primary tumour for T stage on MRI and ADCmean and SUVmax in the index lesion. The variables were analysed in simple and multiple logistic regression analysis. Results: All variables, except ADCmean and SUVmax of the primary tumor, were independent predictors of LN metastasis. In multiple logistic regression analysis the best model was ADCmean in combintion with MRI T-stage where both were independent predictors of LN metastasis, this combination had an AUC of 0.81 which was higher than the AUC of 0.65 for LN ADCmean alone and the AUC of 0.69 for MRI T-stage alone. Conclusions: Several quantitative and qualitative imaging parameters are predictive of regional LN metastasis in PCa. The combination of ADCmean in lymph nodes and T-stage on MRI was the best model in multiple logistic regression with increased predictive value compared to lymph node ADCmean and T-stage on MRI alone.
- 24 August 2015
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 37 (2) , 194-197
Endothelium‐dependent vasodilation is related to the occurrence of cortical brain infarcts at MR imaging
Endothelium-dependent vasodilation in both forearm resistance vessels and the brachial artery was related to the occurrence of cortical, but not lacunar, infarcts at MRI in a population-based sample independently of traditional risk factors.
- 24 August 2015
- Published by Wiley in Clinical Physiology and Functional Imaging
- Vol. 37 (2) , 194-197
Endothelium‐dependent vasodilation is related to the occurrence of cortical brain infarcts at MR imaging
Endothelium-dependent vasodilation in both forearm resistance vessels and the brachial artery was related to the occurrence of cortical, but not lacunar, infarcts at MRI in a population-based sample independently of traditional risk factors.
- 1 December 2012
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (10) , 1112-1117
Gadobenate Dimeglumine (Multihance) in Mr Angiography: An In-Vitro Phantom Comparison with Gadopentetate Dimeglumine (Magnevist) at Different Concentrations
Background Numerous clinical studies suggest that gadobenate dimeglumine is diagnostically superior to other gadolinium chelates for MR imaging applications, including contrast-enhanced MR angiography (CE-MRA). However, confirmatory in-vitro phantom studies have thus far been lacking. Purpose To evaluate the difference in signal intensity achieved with the high-relaxivity MR contrast agent gadobenate dimeglumine (MultiHance) relative to that achieved with the standard-relaxivity non-specific agent gadopentetate dimeglumine (Magnevist) at different concentrations using an in-vitro phantom study design. Material and Methods Test tubes with whole human blood were prepared with concentrations of gadobenate dimeglumine or gadopentetate dimeglumine ranging from 0 to 12 mM. A three-dimensional (3D) T1-weighted gradient echo sequence normally used for CE-MRA of the renal arteries was performed at flip angles of 25° and 35°. The signal-to-noise ratio (SNR) was calculated for all concentrations of both contrast agents. Furthermore a Look-Locker sequence was used and quantitative T1 mapping was performed for all the test tubes. The contrast agent concentration in the aorta was simulated using previously published data on T1 in the aorta during the first pass of a contrast agent. The differences between gadobenate dimeglumine and gadopentetate dimeglumine were compared at the simulated concentrations. Results The SNR achieved with gadobenate dimeglumine was consistently greater than that achieved with gadopentetate dimeglumine at all concentrations. An improvement of 15–25% in SNR was obtained when increasing the flip angle from 25° to 35°. The relative improvement in SNR with gadobenate dimeglumine relative to gadopentetate dimeglumine ranged from 25–72% and was markedly greater at lower concentrations with a flip angle of 35°. Conclusion Our findings suggest that the relative benefit of gadobenate dimeglumine over gadopentetate dimeglumine for CE-MRA applications is greater at lower concentrations.
- 1 December 2012
- Published by SAGE Publications in Acta Radiologica
- Vol. 53 (10) , 1112-1117
Gadobenate Dimeglumine (Multihance) in Mr Angiography: An In-Vitro Phantom Comparison with Gadopentetate Dimeglumine (Magnevist) at Different Concentrations
Background Numerous clinical studies suggest that gadobenate dimeglumine is diagnostically superior to other gadolinium chelates for MR imaging applications, including contrast-enhanced MR angiography (CE-MRA). However, confirmatory in-vitro phantom studies have thus far been lacking. Purpose To evaluate the difference in signal intensity achieved with the high-relaxivity MR contrast agent gadobenate dimeglumine (MultiHance) relative to that achieved with the standard-relaxivity non-specific agent gadopentetate dimeglumine (Magnevist) at different concentrations using an in-vitro phantom study design. Material and Methods Test tubes with whole human blood were prepared with concentrations of gadobenate dimeglumine or gadopentetate dimeglumine ranging from 0 to 12 mM. A three-dimensional (3D) T1-weighted gradient echo sequence normally used for CE-MRA of the renal arteries was performed at flip angles of 25° and 35°. The signal-to-noise ratio (SNR) was calculated for all concentrations of both contrast agents. Furthermore a Look-Locker sequence was used and quantitative T1 mapping was performed for all the test tubes. The contrast agent concentration in the aorta was simulated using previously published data on T1 in the aorta during the first pass of a contrast agent. The differences between gadobenate dimeglumine and gadopentetate dimeglumine were compared at the simulated concentrations. Results The SNR achieved with gadobenate dimeglumine was consistently greater than that achieved with gadopentetate dimeglumine at all concentrations. An improvement of 15–25% in SNR was obtained when increasing the flip angle from 25° to 35°. The relative improvement in SNR with gadobenate dimeglumine relative to gadopentetate dimeglumine ranged from 25–72% and was markedly greater at lower concentrations with a flip angle of 35°. Conclusion Our findings suggest that the relative benefit of gadobenate dimeglumine over gadopentetate dimeglumine for CE-MRA applications is greater at lower concentrations.
- Open Access
- 2 April 2012
- Published by Springer Nature in Environmental Health
- Vol. 11 (1) , 21
Serum concentrations of phthalate metabolites are related to abdominal fat distribution two years later in elderly women
Phthalates, commonly used to soften plastic goods, are known PPAR-agonists affecting lipid metabolism and adipocytes in the experimental setting. We evaluated if circulating concentrations of phthalates were related to different indices of obesity using data from the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS) study. Data from both dual-energy X-ray absorptiometry (DXA) and abdominal magnetic resonance imaging (MRI) were used.
- 2 April 2012
- Published by Springer Nature in Environmental Health
- Vol. 11 (1) , 21
Open AccessSerum concentrations of phthalate metabolites are related to abdominal fat distribution two years later in elderly women
Phthalates, commonly used to soften plastic goods, are known PPAR-agonists affecting lipid metabolism and adipocytes in the experimental setting. We evaluated if circulating concentrations of phthalates were related to different indices of obesity using data from the Prospective Investigation of the Vasculature in Uppsala Seniors (PIVUS) study. Data from both dual-energy X-ray absorptiometry (DXA) and abdominal magnetic resonance imaging (MRI) were used.
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 63-61
Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial)
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 63-61
Open AccessSuperior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial)
- Open Access
- 19 June 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (2) , 394-401
Whole‐body T1 mapping improves the definition of adipose tissue: Consequences for automated image analysis
Purpose To determine whether a whole-body T1-mapping acquisition method improves the definition of adipose tissue (AT) and simplifies automated AT segmentation compared to an image-based method. Materials and Methods The study included 10 subjects. Two whole-body volumes were acquired from each subject using two different flip angles. Whole-body T1 maps were calculated from each pair of whole-body volumes. AT was automatically segmented from the T1 maps and from the original image slices. The results were evaluated using manually segmented slices as reference. Results The T1-mapping method segmented more of the reference AT than the image-based method, with mean values (standard deviations (SDs)) of 87.7(5.1)% and 81.1(5.2)%, respectively. Compared to the image-based method, the T1-mapping method gives better histogram separation of AT in whole-body volumes. The suggested method also provides an output with smaller in-slice AT intensity variations. Conclusion The T1-mapping method improves the definition of AT. T1-based analysis is superior to analysis based on the original images, and allows fully automated and accurate whole-body AT segmentation. J. Magn. Reson. Imaging 2006.
- 19 June 2006
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 24 (2) , 394-401
Open AccessWhole‐body T1 mapping improves the definition of adipose tissue: Consequences for automated image analysis
Purpose To determine whether a whole-body T1-mapping acquisition method improves the definition of adipose tissue (AT) and simplifies automated AT segmentation compared to an image-based method. Materials and Methods The study included 10 subjects. Two whole-body volumes were acquired from each subject using two different flip angles. Whole-body T1 maps were calculated from each pair of whole-body volumes. AT was automatically segmented from the T1 maps and from the original image slices. The results were evaluated using manually segmented slices as reference. Results The T1-mapping method segmented more of the reference AT than the image-based method, with mean values (standard deviations (SDs)) of 87.7(5.1)% and 81.1(5.2)%, respectively. Compared to the image-based method, the T1-mapping method gives better histogram separation of AT in whole-body volumes. The suggested method also provides an output with smaller in-slice AT intensity variations. Conclusion The T1-mapping method improves the definition of AT. T1-based analysis is superior to analysis based on the original images, and allows fully automated and accurate whole-body AT segmentation. J. Magn. Reson. Imaging 2006.