Kyoo-Dong Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kyoo-Dong Song has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
D. K. Jeong
Department of Animal Biotechnology; Faculty of Biotechnology; Jeju National University; Jeju 690-756 Korea
1 shared publication- Dong-Woo Cho
Korea Institute of Civil Engineering & Building Technology, 283 Goyangdae-ro, Ilsanseo-gu, Goyang-si 10223, Korea
1 shared publication H. K. Lee
The Animal Genomics and Breeding Center; Hankyong National University; Anseong-si Gyeonggi-do 456-749 Korea
1 shared publication- Hae-Kwon Jung
Building Research Department, Korea Institute of Civil Engineering and Building Technology, 283 Goyangdae-Ro, Ilsanseo-Gu, Goyang-Si, Gyeonggi-Do 411-712, Korea
1 shared publication - Hakgeun Jeong
Energy ICT∙ESS Laboratory, Korea Institute of Energy Research, Daejeon 34101, Korea
1 shared publication J. H. Kim
Department of Animal Biotechnology; Faculty of Biotechnology; Jeju National University; Jeju 690-756 Korea
1 shared publication
Latest Publications
- Open Access
Reliability Field Test of the Air–Surface Temperature Ratio Method for In Situ Measurement of U-Values
This study proposes the air–surface temperature ratio (ASTR) method as an in situ measurement method to rapidly and accurately measure wall U-values in existing houses. Herein, the wall U-values were measured in situ applying the heat flow meter (HFM) method of ISO 9869-1 and the ASTR method. The results obtained using the HFM and ASTR methods were compared, and the relative error rate and accuracy of the measurements were analyzed. The aging rates of the wall U-values were compared and analyzed by comparing them with the wall U-values before and after the installation of retrofit insulation. Subsequently, the ASTR method was used to analyze the U-value measurement error rates according to the number of measurement days (one day to seven days). In addition, this method calculated the appropriate measurement period required to satisfy the measurement conditions. As a result, the mean relative measurement errors rates of the HFM and ASTR methods were ±3.21%. The short-term (one day) and long-term (seven days or longer) measurement results indicated the average error rates as approximately ±2.63%. These results were included in the tolerance range. Therefore, it was determined that the ASTR method can rapidly and accurately measure wall U-values.
Open AccessReliability Field Test of the Air–Surface Temperature Ratio Method for In Situ Measurement of U-Values
This study proposes the air–surface temperature ratio (ASTR) method as an in situ measurement method to rapidly and accurately measure wall U-values in existing houses. Herein, the wall U-values were measured in situ applying the heat flow meter (HFM) method of ISO 9869-1 and the ASTR method. The results obtained using the HFM and ASTR methods were compared, and the relative error rate and accuracy of the measurements were analyzed. The aging rates of the wall U-values were compared and analyzed by comparing them with the wall U-values before and after the installation of retrofit insulation. Subsequently, the ASTR method was used to analyze the U-value measurement error rates according to the number of measurement days (one day to seven days). In addition, this method calculated the appropriate measurement period required to satisfy the measurement conditions. As a result, the mean relative measurement errors rates of the HFM and ASTR methods were ±3.21%. The short-term (one day) and long-term (seven days or longer) measurement results indicated the average error rates as approximately ±2.63%. These results were included in the tolerance range. Therefore, it was determined that the ASTR method can rapidly and accurately measure wall U-values.
- Open Access
- 26 September 2017
- Published by MDPI AG in Sustainability
- Vol. 9 (10) , 1731
Resolving Stack Effect Problems in a High-Rise Office Building by Mechanical Pressurization
In high-rise buildings, the stack effect causes various problems, especially problems related to excessive pressure differences across main entrance doors and elevator doors, particularly in heating seasons. To reduce the stack effect, this study aims to find effective operation schemes for the HVAC systems in a 60-story commercial building, located in Seoul, Korea. Field measurements were conducted to identify the problems related to the stack effect in the building. Computer simulations were conducted to examine the effectiveness of various HVAC operation schemes in reducing the stack effect. Then, an optimum and effective operation scheme was adopted from the computer simulation results and applied in the field. The adopted scheme was used to pressurize the upper zone of the building. Through field application and an adjustment process, a proper amount of air volume was found to effectively pressurize the upper zone of this building, solving the problems related to the stack effect. The required air volume for pressurization was maintained in the building by reducing the volume of the exhaust air (EA) while maintaining a constant volume of outdoor air (OA).
- 26 September 2017
- Published by MDPI AG in Sustainability
- Vol. 9 (10) , 1731
Open AccessResolving Stack Effect Problems in a High-Rise Office Building by Mechanical Pressurization
In high-rise buildings, the stack effect causes various problems, especially problems related to excessive pressure differences across main entrance doors and elevator doors, particularly in heating seasons. To reduce the stack effect, this study aims to find effective operation schemes for the HVAC systems in a 60-story commercial building, located in Seoul, Korea. Field measurements were conducted to identify the problems related to the stack effect in the building. Computer simulations were conducted to examine the effectiveness of various HVAC operation schemes in reducing the stack effect. Then, an optimum and effective operation scheme was adopted from the computer simulation results and applied in the field. The adopted scheme was used to pressurize the upper zone of the building. Through field application and an adjustment process, a proper amount of air volume was found to effectively pressurize the upper zone of this building, solving the problems related to the stack effect. The required air volume for pressurization was maintained in the building by reducing the volume of the exhaust air (EA) while maintaining a constant volume of outdoor air (OA).
- Open Access
Influence of Lighting Loads upon Thermal Comfort under CBAD and UFAD Systems
Under-floor air distribution (UFAD) systems are occupied-area-based air conditioning systems that generally offer advantages over ceiling-based air distribution (CBAD) systems in terms of energy efficiency and thermal comfort; accordingly, UFAD systems have become more popular lately. The purpose of this study is to provide reasonable UFAD application conditions by comparing and analyzing the influences of cooling loads when UFAD and CBAD are applied to thermally control indoor environments. A chamber experiment was conducted to allow comparisons of the indoor thermal environment under CBAD and UFAD, with the experimental variables of the thermal load of the occupied area and the supply airflow rate. In conclusion, the lower the supply airflow and the higher the lighting power density, the more the thermal comfort of the indoor environment could be improved by using UFAD instead of CBAD. In the lighting power density range of 0–30 W/m2, correlations were calculated whereby the lighting power density levels could be predicted that would ensure thermal comfort at a desired level.
Open AccessInfluence of Lighting Loads upon Thermal Comfort under CBAD and UFAD Systems
Under-floor air distribution (UFAD) systems are occupied-area-based air conditioning systems that generally offer advantages over ceiling-based air distribution (CBAD) systems in terms of energy efficiency and thermal comfort; accordingly, UFAD systems have become more popular lately. The purpose of this study is to provide reasonable UFAD application conditions by comparing and analyzing the influences of cooling loads when UFAD and CBAD are applied to thermally control indoor environments. A chamber experiment was conducted to allow comparisons of the indoor thermal environment under CBAD and UFAD, with the experimental variables of the thermal load of the occupied area and the supply airflow rate. In conclusion, the lower the supply airflow and the higher the lighting power density, the more the thermal comfort of the indoor environment could be improved by using UFAD instead of CBAD. In the lighting power density range of 0–30 W/m2, correlations were calculated whereby the lighting power density levels could be predicted that would ensure thermal comfort at a desired level.
- 6 March 2015
- Published by Wiley in Animal Genetics
- Vol. 46 (3) , 255-264
Evaluation of body growth and immunity-related differentially expressed genes through deep RNA sequencing in the piglets of Jeju native pig and Berkshire
This study was carried out with the objective to investigate the differentially expressed genes (DEGs) between Jeju native pig (JNP) and Berkshire piglets. The RNA-Seq technique was used to investigate the transcriptomes in the fat, liver and longissimus dorsi muscle from these two breeds. Paired-end reads of the sequences that passed the quality filters were aligned to the Sus scrofa genome using tophat2 (v2.0.2). In this study, 65% of muscle, 20% of fat and 54% of liver genes showed higher expression in the piglets of JNP than in Berkshire. Gene Ontology and signaling pathways showed that immune response and lipid metabolisms were commonly enriched pathways in all three tissues. It was found that the genes pertaining to body growth and immune system are significantly (P < 0.01) more highly expressed in Berkshire piglets. DEGs explored between the piglets of the two breeds might influence the identification of the genetic markers for further breed improvement programs. Our findings provide a new perspective for understanding and identifying candidate genes that are involved in various biological functions. Moreover, transcriptome analysis makes it easier to understand the differences between genetic mechanisms of breeds.
- 6 March 2015
- Published by Wiley in Animal Genetics
- Vol. 46 (3) , 255-264
Evaluation of body growth and immunity-related differentially expressed genes through deep RNA sequencing in the piglets of Jeju native pig and Berkshire
This study was carried out with the objective to investigate the differentially expressed genes (DEGs) between Jeju native pig (JNP) and Berkshire piglets. The RNA-Seq technique was used to investigate the transcriptomes in the fat, liver and longissimus dorsi muscle from these two breeds. Paired-end reads of the sequences that passed the quality filters were aligned to the Sus scrofa genome using tophat2 (v2.0.2). In this study, 65% of muscle, 20% of fat and 54% of liver genes showed higher expression in the piglets of JNP than in Berkshire. Gene Ontology and signaling pathways showed that immune response and lipid metabolisms were commonly enriched pathways in all three tissues. It was found that the genes pertaining to body growth and immune system are significantly (P < 0.01) more highly expressed in Berkshire piglets. DEGs explored between the piglets of the two breeds might influence the identification of the genetic markers for further breed improvement programs. Our findings provide a new perspective for understanding and identifying candidate genes that are involved in various biological functions. Moreover, transcriptome analysis makes it easier to understand the differences between genetic mechanisms of breeds.
- 1 October 2007
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 16 (5) , 411-425
Determining Photosensor Conditions of a Daylight Dimming Control System Using Different Double-skin Envelope Configurations
Daylight responsive dimming control systems are analysed in a small office with a double-skin envelope to recommend better control alternatives for achieving target illuminance and better energy savings. Computer simulations are performed for photosensors positioned at three different locations in three different shielding conditions. These are applied in both northwards and southwards facing rooms. Daylight conditions included three sky types at different times of the day and year. Shading device conditions are: a horizontal blind on the external envelope, a combination of a horizontal blind on an external envelope and a retractable shading device on an internal envelope. A partially-shielded condition generally achieved good dimming performance under clear and intermediate cloudy skies. Regardless of position, the unshielded photosensors generally fails to achieve target illuminance, providing excessive dimming levels for all tested daylight conditions. Reasonable lighting energy savings are achieved. The savings were not critically influenced by the photosensor positions, but rather are impacted significantly by the sky conditions. Linear prediction models are studied to determine the relationship between photosensor signals and workplane illuminance according to photosensor conditions. The models are acceptable with low significance levels. The linear correlation is best for the partially-shielded condition, but the correlation is weaker for the fully-shielded photosensor.
- 1 October 2007
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 16 (5) , 411-425
Determining Photosensor Conditions of a Daylight Dimming Control System Using Different Double-skin Envelope Configurations
Daylight responsive dimming control systems are analysed in a small office with a double-skin envelope to recommend better control alternatives for achieving target illuminance and better energy savings. Computer simulations are performed for photosensors positioned at three different locations in three different shielding conditions. These are applied in both northwards and southwards facing rooms. Daylight conditions included three sky types at different times of the day and year. Shading device conditions are: a horizontal blind on the external envelope, a combination of a horizontal blind on an external envelope and a retractable shading device on an internal envelope. A partially-shielded condition generally achieved good dimming performance under clear and intermediate cloudy skies. Regardless of position, the unshielded photosensors generally fails to achieve target illuminance, providing excessive dimming levels for all tested daylight conditions. Reasonable lighting energy savings are achieved. The savings were not critically influenced by the photosensor positions, but rather are impacted significantly by the sky conditions. Linear prediction models are studied to determine the relationship between photosensor signals and workplane illuminance according to photosensor conditions. The models are acceptable with low significance levels. The linear correlation is best for the partially-shielded condition, but the correlation is weaker for the fully-shielded photosensor.