Ashok Kumar
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ashok Kumar has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Shashi Khare
National Centre for Disease Control, Sham Nath Marg, Delhi, 110054, India
8 shared publications- Ankur Kaushal
Department of Biosciences and Technology, Maharishi Markandeshwar Engineering College, Maharishi Markandeshwar (Deemed to be University), Mullana, Ambala, India
6 shared publications Swati Singh
CSIR-Institute of Genomics and Integrative Biology, New Delhi, India and Academy of Scientific and Innovative Research (AcSIR, New Delhi, India
4 shared publications- Minakshi Sharma
Maharshi Dayanand University
3 shared publications Anita Dalal
CSIR-Institute of Genomics and Integrative Biology
2 shared publicationsDeepika Bhatnagar
CSIR-Institute of Genomics and Integrative Biology, Mall Road, Delhi, 110007, India; CSIR-Central Scientific Instruments Organisation, Sector 30-C, Chandigarh, 160030, India; Academy of Scientific and Innovative Research (AcSIR), New Delhi, India
2 shared publications
Latest Publications
- Open Access
- 26 February 2021
- Published by Research Lake International Inc. in International Journal of Biomedical and Clinical Analysis
- Vol. 1 (1) , 17-27
Rapid Bispecific Antibodies Based Homogeneous Immunoassay for Detection of Prostate-Specific Antigen (PSA)
Development of rapid and economical method for detection of prostate- specific antigen (PSA) in human blood. Methods: The usual procedure for the detection of prostate cancer markers in human is prostate-specific antigen (PSA) in blood (normal level ≤ 4 ng/mL) using heterogeneous immunoassay enzyme linked immunosorbent assay (ELISA). However, a rapid homogeneous immunoassay for the detection of PSA in serum, based on bispecific antibodies, is more convenient due to its speed, accuracy and obviating the need of multiple washing steps. The assay using bispecific antibody P57 (against PSA and peroxidase) and monospecific antibody B87 (against PSA) conjugated with glucose oxidase was developed in the presence of excess catalase. Similarly, in solid phase homogeneous immunoassay the monospecific antibody B87 (against PSA) and glucose oxidase were immobilized onto a solid support (plastic) and other reagents, bio-chemicals, and bispecific antibody P57 were taken in homogeneous solution. All variables, viz., glucose oxidase, peroxidase and catalase were optimized at different PSA concentrations. Results: Homogeneous immunoassay (HIA) showed linearity of PSA detection 1-10 ng/mL whereas, solid phase homogeneous immunoassay (SPHIA) showed in the range of 1-50 ng/mL suggesting SPHIA has a broader operating range, thus much better than HIA. Detection of PSA in a homogeneous solution can be completed in 90 minutes without involving any washing and incubation steps. Conclusions: Homogeneous assay is a rapid, economical method that eliminates all washing and incubation steps of conventional ELISA.
- 26 February 2021
- Published by Research Lake International Inc. in International Journal of Biomedical and Clinical Analysis
- Vol. 1 (1) , 17-27
Open AccessRapid Bispecific Antibodies Based Homogeneous Immunoassay for Detection of Prostate-Specific Antigen (PSA)
Development of rapid and economical method for detection of prostate- specific antigen (PSA) in human blood. Methods: The usual procedure for the detection of prostate cancer markers in human is prostate-specific antigen (PSA) in blood (normal level ≤ 4 ng/mL) using heterogeneous immunoassay enzyme linked immunosorbent assay (ELISA). However, a rapid homogeneous immunoassay for the detection of PSA in serum, based on bispecific antibodies, is more convenient due to its speed, accuracy and obviating the need of multiple washing steps. The assay using bispecific antibody P57 (against PSA and peroxidase) and monospecific antibody B87 (against PSA) conjugated with glucose oxidase was developed in the presence of excess catalase. Similarly, in solid phase homogeneous immunoassay the monospecific antibody B87 (against PSA) and glucose oxidase were immobilized onto a solid support (plastic) and other reagents, bio-chemicals, and bispecific antibody P57 were taken in homogeneous solution. All variables, viz., glucose oxidase, peroxidase and catalase were optimized at different PSA concentrations. Results: Homogeneous immunoassay (HIA) showed linearity of PSA detection 1-10 ng/mL whereas, solid phase homogeneous immunoassay (SPHIA) showed in the range of 1-50 ng/mL suggesting SPHIA has a broader operating range, thus much better than HIA. Detection of PSA in a homogeneous solution can be completed in 90 minutes without involving any washing and incubation steps. Conclusions: Homogeneous assay is a rapid, economical method that eliminates all washing and incubation steps of conventional ELISA.
- 1 June 2019
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 130, 720-726
Hemagglutinin gene based biosensor for early detection of swine flu (H1N1) infection in human
- 1 June 2019
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 130, 720-726
Hemagglutinin gene based biosensor for early detection of swine flu (H1N1) infection in human
- 5 December 2018
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 116 (2) , 444-451
Recent advances in biosensors for diagnosis of celiac disease: A review
Celiac disease (CD) is an intestinal issue activated by the inappropriate immune reaction towards gluten protein of wheat, rye, barley, oats, and autoantigen, tissue transglutaminase. Regardless of the accessibility of immunochemical conventions for research facility analysis of CD, there is as yet a need of speedier, less expensive, and simpler devices for diagnosing CD. This review concentrates on progresses in biosensors for diagnosing CD in perspective of the scaled down hardware, multianalyte discovery and low sample volume necessity. Various recently developed biosensors in this field are presented.
- 5 December 2018
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 116 (2) , 444-451
Recent advances in biosensors for diagnosis of celiac disease: A review
Celiac disease (CD) is an intestinal issue activated by the inappropriate immune reaction towards gluten protein of wheat, rye, barley, oats, and autoantigen, tissue transglutaminase. Regardless of the accessibility of immunochemical conventions for research facility analysis of CD, there is as yet a need of speedier, less expensive, and simpler devices for diagnosing CD. This review concentrates on progresses in biosensors for diagnosing CD in perspective of the scaled down hardware, multianalyte discovery and low sample volume necessity. Various recently developed biosensors in this field are presented.
- 15 January 2018
- Published by Emerald Publishing in Sensor Review
- Vol. 38 (1) , 92-98
Recent advances in sensors for early detection of pathogens causing rheumatic heart disease
Purpose: There is an immense concern in the international community about controlling the outburst of infectious diseases. An essential step towards diminishing it is the development of an adequate detection system. Among the huge plethora of microorganisms which may infect the human body, Streptococcus pyogenes is important one which infects the upper respiratory tract leading to sore throat, which eventually develops into rheumatic heart disease (RHD) in the absence of timely treatment. A major process in controlling the infection is to detect it at an early stage. Hence, there is a need to develop detection tools which are both rapid and reliable. Design/methodology/approach: Different types of diagnostic methods are available for identification, but the most commonly used are culturing, staining and rapid antigen detection tests. For better sensitivity and specificity, this review describes the development of biosensor. Compared with the current available methods, which are usually cumbersome, time-consuming and expensive, this approach features sequence specificity, cost efficiency, rapid and ease of use. Findings: This review outlines various sensors which are available for the detection of Streptococcus pyogenes which causes human RHD. The working scheme of the sensors, their sensitivity and limitation of detection has been described in the review. Originality/value: The review fulfills an acknowledged the need to study various sensors that are available for the detection of Streptococcus pyogenes, causing human RHD.
- 15 January 2018
- Published by Emerald Publishing in Sensor Review
- Vol. 38 (1) , 92-98
Recent advances in sensors for early detection of pathogens causing rheumatic heart disease
Purpose: There is an immense concern in the international community about controlling the outburst of infectious diseases. An essential step towards diminishing it is the development of an adequate detection system. Among the huge plethora of microorganisms which may infect the human body, Streptococcus pyogenes is important one which infects the upper respiratory tract leading to sore throat, which eventually develops into rheumatic heart disease (RHD) in the absence of timely treatment. A major process in controlling the infection is to detect it at an early stage. Hence, there is a need to develop detection tools which are both rapid and reliable. Design/methodology/approach: Different types of diagnostic methods are available for identification, but the most commonly used are culturing, staining and rapid antigen detection tests. For better sensitivity and specificity, this review describes the development of biosensor. Compared with the current available methods, which are usually cumbersome, time-consuming and expensive, this approach features sequence specificity, cost efficiency, rapid and ease of use. Findings: This review outlines various sensors which are available for the detection of Streptococcus pyogenes which causes human RHD. The working scheme of the sensors, their sensitivity and limitation of detection has been described in the review. Originality/value: The review fulfills an acknowledged the need to study various sensors that are available for the detection of Streptococcus pyogenes, causing human RHD.
- 3 January 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 11 (5) , 1539-1540
Correction to: Ultrasensitive Nanosensor for Detection of Malic Acid in Tomato as Fruit Ripening Indicator
- 3 January 2018
- Published by Springer Nature in Food Analytical Methods
- Vol. 11 (5) , 1539-1540
Correction to: Ultrasensitive Nanosensor for Detection of Malic Acid in Tomato as Fruit Ripening Indicator
- 1 December 2017
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 105, 905-911
Ultrasensitive transglutaminase based nanosensor for early detection of celiac disease in human
- 1 December 2017
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 105, 905-911
Ultrasensitive transglutaminase based nanosensor for early detection of celiac disease in human
- 1 October 2017
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 103, 355-359
DNA chip based sensor for amperometric detection of infectious pathogens
- 1 October 2017
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 103, 355-359
DNA chip based sensor for amperometric detection of infectious pathogens
- 26 May 2017
- Published by Springer Nature in Food Analytical Methods
- Vol. 10 (11) , 3680-3686
Ultrasensitive Nanosensor for Detection of Malic Acid in Tomato as Fruit Ripening Indicator
- 26 May 2017
- Published by Springer Nature in Food Analytical Methods
- Vol. 10 (11) , 3680-3686
Ultrasensitive Nanosensor for Detection of Malic Acid in Tomato as Fruit Ripening Indicator
- 1 February 2017
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 95, 505-510
Ultrasensitive cardiac troponin I antibody based nanohybrid sensor for rapid detection of human heart attack
- 1 February 2017
- Published by Elsevier in International Journal of Biological Macromolecules
- Vol. 95, 505-510
Ultrasensitive cardiac troponin I antibody based nanohybrid sensor for rapid detection of human heart attack
- 22 September 2016
- Published by Springer Nature in Indian Journal of Microbiology
- Vol. 57 (1) , 112-115
Gene Specific Impedimetric Bacterial DNA Sensor for Rheumatic Heart Disease
An impedimetric mga gene specific DNA sensor was developed by immobilization of single stranded DNA probe onto the screen printed modified gold-dendrimer nanohybrid composite electrode for early and rapid detection of S. pyogenes in human throat swab samples causing rheumatic heart disease. Electrochemical impedance response was measured after hybridization with bacterial single stranded genomic DNA (ssG-DNA) with probe. The sensor was found highly specific to S. pyogenes and can detect as low as 0.01 ng ssDNA in 6 µL sample only in 30 min. The nanohybrid sensor was also tested with non-specific pathogens and characterized by FTIR. An early detection of the pathogen S. pyogenes in human can save damage of mitral and aortic heart valves (rheumatic heart disease) by proper medical care.
- 22 September 2016
- Published by Springer Nature in Indian Journal of Microbiology
- Vol. 57 (1) , 112-115
Gene Specific Impedimetric Bacterial DNA Sensor for Rheumatic Heart Disease
An impedimetric mga gene specific DNA sensor was developed by immobilization of single stranded DNA probe onto the screen printed modified gold-dendrimer nanohybrid composite electrode for early and rapid detection of S. pyogenes in human throat swab samples causing rheumatic heart disease. Electrochemical impedance response was measured after hybridization with bacterial single stranded genomic DNA (ssG-DNA) with probe. The sensor was found highly specific to S. pyogenes and can detect as low as 0.01 ng ssDNA in 6 µL sample only in 30 min. The nanohybrid sensor was also tested with non-specific pathogens and characterized by FTIR. An early detection of the pathogen S. pyogenes in human can save damage of mitral and aortic heart valves (rheumatic heart disease) by proper medical care.