Judith Harrer-Haag
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Judith Harrer-Haag has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
Christof Klötzsch
Department of Neurology, RWTH Aachen University Hospital, Pauwelsstr. 30, D-52074 Aachen, Germany
4 shared publicationsF. Schlachetzki
Universität Regensburg, Bezirksklinikum Regensburg
3 shared publicationsWalter Möller-Hartmann
3 shared publicationsJ. Valaikiene
2 shared publicationsMarkus F. Oertel
2 shared publicationsTiemo Wessels
Department of Neurology, RWTH Aachen University Hospital, Pauwelsstr 30, D-52074 Aachen, Germany
2 shared publications
Latest Publications
- 1 November 2024
- Published by Deutscher Arzte-Verlag GmbH in Deutsches Ärzteblatt international
- Vol. 121 (22) , 739
Hallucinations while using guanfacine in ADHD
- 1 November 2024
- Published by Deutscher Arzte-Verlag GmbH in Deutsches Ärzteblatt international
- Vol. 121 (22) , 739
Hallucinations while using guanfacine in ADHD
- 12 March 2019
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 50 (01) , 28-42
Neurovaskuläre Erkrankungen – Ultraschalldiagnostik
Zusammenfassung: Neurovaskuläre Erkrankungen gehören zu den häufigsten Erkrankungen im neurologischen Fachgebiet. Vor dem Hintergrund der immer älter werdenden Gesellschaft spielt der Schlaganfall und damit dessen Diagnostik eine herausragende Rolle. Für den Neurologen in eigener Hand ermöglicht der Ultraschall nicht nur die Einschätzung der Gefäßsituation in der Primärprophylaxe, sondern selbstverständlich v. a. beim akuten Schlaganfall bei Beantwortung der Fragestellung hinsichtlich einer Thrombektomie oder Thrombolyse. Auch im Verlauf hilft der Ultraschall bei der ätiologischen Zuordnung und somit wichtige Therapieentscheidungen zu treffen. Hier sind neben arteriosklerotischen Obstruktionen insbesondere Dissektionen zu nennen. In der Zukunft wird aufgrund der neuen Studienlage pro invasiver Therapie auch die sonografische Detektion eines kardialen Rechts-Links-Shunts mittels transkranieller Doppler- oder Duplexsonografie von noch größerer Bedeutung sein. Nach therapeutischen Eingriffen insbesondere an der extrakraniellen Arteria carotis interna wird die Sonografie zur Beurteilung des Operations- oder Interventionsergebnisses und bei der Verlaufskontrolle genutzt. Ebenso gelingt mit dem Ultraschall auch die Verlaufsbeurteilung intrakranieller Stenosen. Wertvoll ist der transkranielle Ultraschall auch in der Diagnostik auf der Intensivstation, bspw. zur Detektion erhöhten Hirndrucks oder in der Hirntoddiagnostik. Andere Anwendungen sind bspw. die Detektion von intrakraniellen Vasospasmen nach Subarachnoidalblutungen, die Diagnostik von Vaskulitiden der hirnversorgenden Gefäße, und neuerdings auch der transorbitale Ultraschall bei ischämischen Ophthalmopathien. Therapeutisch wird der Ultraschall in der Neurologie bisher überwiegend auf wissenschaftlicher Basis im Rahmen von Studien zur Sonothrombolyse eingesetzt. Die Anwendung transkranieller Sonografie zeigte beim akuten Mediaverschluss eine höhere Rekanalisationsrate, es kam allerdings auch zu etwas häufigeren, statistisch nicht signifikanten symptomatischen Einblutungen. In den meisten Fällen ist bei der alltäglichen Anwendung der Duplexsonografie der Vorzug zu geben, aber auch die einfache Dopplersonografie gehört nach wie vor zum Standardrepertoire der meisten Ultraschallabore. In diesem Artikel möchten wir Ihnen über die wichtigsten Anwendungen des Ultraschalls in der Neurologie einen Überblick geben.
- 12 March 2019
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 50 (01) , 28-42
Neurovaskuläre Erkrankungen – Ultraschalldiagnostik
Zusammenfassung: Neurovaskuläre Erkrankungen gehören zu den häufigsten Erkrankungen im neurologischen Fachgebiet. Vor dem Hintergrund der immer älter werdenden Gesellschaft spielt der Schlaganfall und damit dessen Diagnostik eine herausragende Rolle. Für den Neurologen in eigener Hand ermöglicht der Ultraschall nicht nur die Einschätzung der Gefäßsituation in der Primärprophylaxe, sondern selbstverständlich v. a. beim akuten Schlaganfall bei Beantwortung der Fragestellung hinsichtlich einer Thrombektomie oder Thrombolyse. Auch im Verlauf hilft der Ultraschall bei der ätiologischen Zuordnung und somit wichtige Therapieentscheidungen zu treffen. Hier sind neben arteriosklerotischen Obstruktionen insbesondere Dissektionen zu nennen. In der Zukunft wird aufgrund der neuen Studienlage pro invasiver Therapie auch die sonografische Detektion eines kardialen Rechts-Links-Shunts mittels transkranieller Doppler- oder Duplexsonografie von noch größerer Bedeutung sein. Nach therapeutischen Eingriffen insbesondere an der extrakraniellen Arteria carotis interna wird die Sonografie zur Beurteilung des Operations- oder Interventionsergebnisses und bei der Verlaufskontrolle genutzt. Ebenso gelingt mit dem Ultraschall auch die Verlaufsbeurteilung intrakranieller Stenosen. Wertvoll ist der transkranielle Ultraschall auch in der Diagnostik auf der Intensivstation, bspw. zur Detektion erhöhten Hirndrucks oder in der Hirntoddiagnostik. Andere Anwendungen sind bspw. die Detektion von intrakraniellen Vasospasmen nach Subarachnoidalblutungen, die Diagnostik von Vaskulitiden der hirnversorgenden Gefäße, und neuerdings auch der transorbitale Ultraschall bei ischämischen Ophthalmopathien. Therapeutisch wird der Ultraschall in der Neurologie bisher überwiegend auf wissenschaftlicher Basis im Rahmen von Studien zur Sonothrombolyse eingesetzt. Die Anwendung transkranieller Sonografie zeigte beim akuten Mediaverschluss eine höhere Rekanalisationsrate, es kam allerdings auch zu etwas häufigeren, statistisch nicht signifikanten symptomatischen Einblutungen. In den meisten Fällen ist bei der alltäglichen Anwendung der Duplexsonografie der Vorzug zu geben, aber auch die einfache Dopplersonografie gehört nach wie vor zum Standardrepertoire der meisten Ultraschallabore. In diesem Artikel möchten wir Ihnen über die wichtigsten Anwendungen des Ultraschalls in der Neurologie einen Überblick geben.
- 17 October 2012
- Published by Springer Nature in Medizinische Klinik - Intensivmedizin und Notfallmedizin
- Vol. 108 (2) , 131-138
Sonographische Diagnostik in der neurologischen Notfall- und Intensivmedizin
- 17 October 2012
- Published by Springer Nature in Medizinische Klinik - Intensivmedizin und Notfallmedizin
- Vol. 108 (2) , 131-138
Sonographische Diagnostik in der neurologischen Notfall- und Intensivmedizin
- 22 April 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (S 01) , 95-101
Transcranial Perfusion Sonography Using a Low Mechanical Index and Pulse Inversion Harmonic Imaging: Reliability, Inter-/Intraobserver Variability
Ziel: Die transkranielle Perfusionssonografie (TPS) ist eine neue, nicht invasive Methode zur Darstellung der Hirnperfusion. Ziel war die Bewertung einer neuen TPS-Modalität, die einen niedrigen MI mit einer hohen (nahezu Echtzeit) Bildrate kombiniert und die Untersuchung deren Intra- und Interobserver-Variabilität. Material und Methoden: 10 gesunde Probanden erhielten 3-mal TPS mit einem niedrigen MI (1,0) und einer hohen Bildrate (8,3 Hz). Die Untersuchungen wurden von 2 Sonografeuren im Cross-over-Design durchgeführt: 1. 2-fache Messungen bei je 5 Probanden (Intraobserver-Testung); und 2. einfache Untersuchung der jeweils anderen 5 Probanden (Interobserver-Testung). Aus 8 etablierten Regions of Interest (ROI) wurden Zeitintensitätskurven (TIC) und deren Maximalintensität (PI), Zeit-bis-zur-PI (TTP), Fläche-unter-der-Kurve (AUC) und zerebrale Transitzeit (CTT) berechnet. Die Qualität der TIC wurde mithilfe des Determinationskoeffizienten abgebildet. TIC-Parameter wurden deskriptiv dargestellt. Intra- und Interobserver-Variabilität wurde nach Spearman untersucht. Ergebnisse: Die TIC-Qualität war sehr gut (r2 = 0,92, 0,87 – 0,97). Die Intraobserver-Variabilität war bei dem erfahreneren Untersucher geringer (r = 0,70 vs. r = 0,29). Die Interobserver-Reliabilität lag bei r = 0,34 (p < 0,05) und war damit moderat. TTP (25,7 – 28,1 s; Mittel 26,8 s) und CTT (8,2 – 10,7 s; Mittel 9,9 s) waren die robustesten Parameter. Schlussfolgerung: TPS mit niedrigem MI erlaubt transkranielle Perfusionsuntersuchungen unter nahezu Echtzeitbedingungen. Dies ermöglicht eine bessere Kontrolle der Sondenposition. Solide Ultraschallerfahrung gewährt eine hohe Reliabilität dieser Technik und macht TPS zu einem interessanten Modus für Diagnostik und Follow-up von Perfusionsveränderungen z. B. bei Schlaganfällen oder anti-angiogenetischer Tumortherapie. Purpose: Transcranial perfusion sonography (TPS) is an emerging noninvasive bedside method for evaluating brain perfusion. The purpose was to assess the feasibility of a low MI/almost real-time frame rate approach and to test its intra-/interobserver variability. Materials and Methods: 10 healthy volunteers were investigated 3 times with TPS at a low MI (1.0) and a high frame rate (8.3 Hz). Investigations were performed by 2 sonographers in a cross-over design: 1.) twofold measurements each with 5 volunteers (intraobserver test), and 2.) single measurements of the other 5 volunteers (interobserver test). From 8 established regions of interest (ROI), time-intensity curves (TIC) with the following parameters were calculated: peak intensity (PI), time-to-PI (TTP), area-under-curve (AUC), and cerebral transit time (CTT). The TIC quality was described by the coefficient of determination. TIC parameters were presented descriptively. Intra- and interobserver variability was tested by Spearman’s correlation. Results: The overall quality of the TIC was very good (mean r2 = 0.92, 0.87 – 0.97). TTP (25.7 – 28.1 sec; mean 26.8 sec) and CTT (8.2 – 10.7 sec; mean 9.9 sec) were the most robust parameters. The intraobserver variability was lower with the more experienced sonographer (r = 0.70 vs. r = 0.29). The interobserver reliability was r = 0.34 (p < 0.05). Conclusion: Low MI TPS allows for nearly real-time imaging facilitating probe control. Sound sonographer experience allows for a high reliability and makes TPS an interesting tool for the diagnosis and follow-up of perfusion changes, e. g. in stroke or anti-angiogenic brain tumor therapy.
- 22 April 2010
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 32 (S 01) , 95-101
Transcranial Perfusion Sonography Using a Low Mechanical Index and Pulse Inversion Harmonic Imaging: Reliability, Inter-/Intraobserver Variability
Ziel: Die transkranielle Perfusionssonografie (TPS) ist eine neue, nicht invasive Methode zur Darstellung der Hirnperfusion. Ziel war die Bewertung einer neuen TPS-Modalität, die einen niedrigen MI mit einer hohen (nahezu Echtzeit) Bildrate kombiniert und die Untersuchung deren Intra- und Interobserver-Variabilität. Material und Methoden: 10 gesunde Probanden erhielten 3-mal TPS mit einem niedrigen MI (1,0) und einer hohen Bildrate (8,3 Hz). Die Untersuchungen wurden von 2 Sonografeuren im Cross-over-Design durchgeführt: 1. 2-fache Messungen bei je 5 Probanden (Intraobserver-Testung); und 2. einfache Untersuchung der jeweils anderen 5 Probanden (Interobserver-Testung). Aus 8 etablierten Regions of Interest (ROI) wurden Zeitintensitätskurven (TIC) und deren Maximalintensität (PI), Zeit-bis-zur-PI (TTP), Fläche-unter-der-Kurve (AUC) und zerebrale Transitzeit (CTT) berechnet. Die Qualität der TIC wurde mithilfe des Determinationskoeffizienten abgebildet. TIC-Parameter wurden deskriptiv dargestellt. Intra- und Interobserver-Variabilität wurde nach Spearman untersucht. Ergebnisse: Die TIC-Qualität war sehr gut (r2 = 0,92, 0,87 – 0,97). Die Intraobserver-Variabilität war bei dem erfahreneren Untersucher geringer (r = 0,70 vs. r = 0,29). Die Interobserver-Reliabilität lag bei r = 0,34 (p < 0,05) und war damit moderat. TTP (25,7 – 28,1 s; Mittel 26,8 s) und CTT (8,2 – 10,7 s; Mittel 9,9 s) waren die robustesten Parameter. Schlussfolgerung: TPS mit niedrigem MI erlaubt transkranielle Perfusionsuntersuchungen unter nahezu Echtzeitbedingungen. Dies ermöglicht eine bessere Kontrolle der Sondenposition. Solide Ultraschallerfahrung gewährt eine hohe Reliabilität dieser Technik und macht TPS zu einem interessanten Modus für Diagnostik und Follow-up von Perfusionsveränderungen z. B. bei Schlaganfällen oder anti-angiogenetischer Tumortherapie. Purpose: Transcranial perfusion sonography (TPS) is an emerging noninvasive bedside method for evaluating brain perfusion. The purpose was to assess the feasibility of a low MI/almost real-time frame rate approach and to test its intra-/interobserver variability. Materials and Methods: 10 healthy volunteers were investigated 3 times with TPS at a low MI (1.0) and a high frame rate (8.3 Hz). Investigations were performed by 2 sonographers in a cross-over design: 1.) twofold measurements each with 5 volunteers (intraobserver test), and 2.) single measurements of the other 5 volunteers (interobserver test). From 8 established regions of interest (ROI), time-intensity curves (TIC) with the following parameters were calculated: peak intensity (PI), time-to-PI (TTP), area-under-curve (AUC), and cerebral transit time (CTT). The TIC quality was described by the coefficient of determination. TIC parameters were presented descriptively. Intra- and interobserver variability was tested by Spearman’s correlation. Results: The overall quality of the TIC was very good (mean r2 = 0.92, 0.87 – 0.97). TTP (25.7 – 28.1 sec; mean 26.8 sec) and CTT (8.2 – 10.7 sec; mean 9.9 sec) were the most robust parameters. The intraobserver variability was lower with the more experienced sonographer (r = 0.70 vs. r = 0.29). The interobserver reliability was r = 0.34 (p < 0.05). Conclusion: Low MI TPS allows for nearly real-time imaging facilitating probe control. Sound sonographer experience allows for a high reliability and makes TPS an interesting tool for the diagnosis and follow-up of perfusion changes, e. g. in stroke or anti-angiogenic brain tumor therapy.
- 24 September 2008
- Published by Springer Nature in Journal of Neurology
- Vol. 255 (9) , 1309-1314
High rate of restenosis after carotid artery stenting in patients with high-grade internal carotid artery stenosis
Carotid endarterectomy (CEA) is the goldstandard procedure for the majority of patients with high-grade symptomatic internal carotid artery stenosis and also for specified high-grade asymptomatic stenoses; however, a proportion of patients are treated with carotid endovascular therapy. We aimed to document medium-term clinical and neurosonographical outcome after carotid artery stenting (CAS).
- 24 September 2008
- Published by Springer Nature in Journal of Neurology
- Vol. 255 (9) , 1309-1314
High rate of restenosis after carotid artery stenting in patients with high-grade internal carotid artery stenosis
Carotid endarterectomy (CEA) is the goldstandard procedure for the majority of patients with high-grade symptomatic internal carotid artery stenosis and also for specified high-grade asymptomatic stenoses; however, a proportion of patients are treated with carotid endovascular therapy. We aimed to document medium-term clinical and neurosonographical outcome after carotid artery stenting (CAS).
- 14 July 2008
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 36 (8) , 472-479
Extracranial and intracranial vertebral artery dissection: Long‐term clinical and duplex sonographic follow‐up
Purpose.: To determine the value of color Doppler sonography (CDUS) in the diagnosis and follow‐up of patients with extracranial and intracranial vertebral artery (VA) dissection.Method.: Thirty‐three patients aged 42 ± 12 years with 40 VADS confirmed via digital subtraction angiography (DSA) (n = 37) and magnetic resonance angiography (MRA) (n = 3) were included in the study. All patients were investigated with extracranial CDUS and transcranial CDUS (TCCDUS) over a mean ± SD follow‐up period of 42 ± 24 months and occurrence of new ischemic symptoms was assessed. Sonographic results were compared with initial and follow‐up angiographic results.Results.: At presentation, 24/33 (73%) patients had suffered an ischemic stroke, 5/33 (15%) had a transient ischemic attack (TIA), and 4/33 (12%) were asymptomatic. Two patients had a recurrent vertebrobasilar TIA; there was no recurrent stroke. The initial DSA findings consisted of 14 stenoses, 20 tapered occlusions, and 6 pseudoaneurysms. During follow‐up, 63% of the vessels recanalized. Sonographic findings were consistent with angiographic findings in 80% at the initial examination and in 86% during follow‐up. The main reason for discordant results was the failure of CDUS to detect pseudoaneurysms. No recurrence occurred in the vertebral arteries (VA), but 1 patient had an asymptomatic carotid artery dissection during follow‐up.Conclusion.: Recurrent TIA or stroke after VAD appears to be extremely rare, independent of recanalization or persistent occlusion of the affected artery. CDUS and TCCDUS provide reliable follow‐up of VAD in all patients presenting with stenosis or occlusion, but do not allow for detection of pseudoaneurysms of the VA. © 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2008
- 14 July 2008
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 36 (8) , 472-479
Extracranial and intracranial vertebral artery dissection: Long‐term clinical and duplex sonographic follow‐up
Purpose.: To determine the value of color Doppler sonography (CDUS) in the diagnosis and follow‐up of patients with extracranial and intracranial vertebral artery (VA) dissection.Method.: Thirty‐three patients aged 42 ± 12 years with 40 VADS confirmed via digital subtraction angiography (DSA) (n = 37) and magnetic resonance angiography (MRA) (n = 3) were included in the study. All patients were investigated with extracranial CDUS and transcranial CDUS (TCCDUS) over a mean ± SD follow‐up period of 42 ± 24 months and occurrence of new ischemic symptoms was assessed. Sonographic results were compared with initial and follow‐up angiographic results.Results.: At presentation, 24/33 (73%) patients had suffered an ischemic stroke, 5/33 (15%) had a transient ischemic attack (TIA), and 4/33 (12%) were asymptomatic. Two patients had a recurrent vertebrobasilar TIA; there was no recurrent stroke. The initial DSA findings consisted of 14 stenoses, 20 tapered occlusions, and 6 pseudoaneurysms. During follow‐up, 63% of the vessels recanalized. Sonographic findings were consistent with angiographic findings in 80% at the initial examination and in 86% during follow‐up. The main reason for discordant results was the failure of CDUS to detect pseudoaneurysms. No recurrence occurred in the vertebral arteries (VA), but 1 patient had an asymptomatic carotid artery dissection during follow‐up.Conclusion.: Recurrent TIA or stroke after VAD appears to be extremely rare, independent of recanalization or persistent occlusion of the affected artery. CDUS and TCCDUS provide reliable follow‐up of VAD in all patients presenting with stenosis or occlusion, but do not allow for detection of pseudoaneurysms of the VA. © 2008 Wiley Periodicals, Inc. J Clin Ultrasound, 2008
- 16 July 2007
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 28 (04) , 380-386
Transcranial Ultrasound Perfusion Imaging: Implementation of a Low MI and a High Frame Rate
Ziel: Die konventionelle transkranielle Perfusionssonographie (ultrasound perfusion imaging, UPI) basiert auf der Bolusinjektion eines Echosignalverstärkers und zeitgetriggerter Bildaufnahme. Zur Optimierung unserer Geräteeinstellungen verglichen wir zwei unterschiedliche Bildraten (frame rate, FR) und Sendeleistungen (angegeben als mechanical index, MI) mit dem Ziel, echtzeitähnliche Untersuchungsbedingungen zu erreichen und hiermit die Berechnung von kinetischen Parametern zu präzisieren. Material und Methoden: Nach Gabe von 1 ml SonoVue® wurde bei 15 gesunden Probanden eine UPI je zweimal durchgeführt: einmal mit hohem MI (1,6) und niedriger FR (0,67 Hz) und zum zweiten mit niedrigem MI (1,0) und hoher FR (5 Hz). Neben der visuellen Analyse wurden aus 3 Hirnregionen (region of interest, ROI) Zeitintensitätskurven mit Maximalintensität (peak intensity, PI), Zeit bis zur PI (time-to-peak-intensity, TP [sec]) und der Fläche unter der Kurve (area-under-the-curve, AUC) errechnet und zwischen den beiden Methoden verglichen. Ergebnisse: Die visuelle Analyse ergab eine nur mäßige Kontrastverstärkung bei 10/15 Probanden und eine deutlich geringere Eindringtiefe mit niedrigem MI/hoher FR, während mit hohem MI/niedriger FR eine starke Kontrastverstärkung bei 13/15 Probanden erreicht wurde. Das Signal-Rausch-Verhältnis war höher bei niedrigem MI/hoher FR. Die TP war bei beiden Methoden vergleichbar (p > 0,05). PI und AUC waren signifikant niedriger bei niedrigem MI/hoher FR (p≤ 0,001), und beide Parameter korrelierten gut in korrespondierenden ROIs (p < 0,05 oder < 0,01 in 8/9 ROIs). Die Parameterbilder spiegelten die Unterschiede beider Methoden wider. Schlussfolgerung: Die neue Geräteeinstellung erlaubt eine hochpräzise kinetische Analyse mit sehr gutem Signal-Rausch-Verhältnis bei Patienten mit exzellentem Knochenfenster. Bei der Mehrzahl der Patienten ist allerdings die konventionelle transkranielle UPI mit hohem MI und dementsprechend niedriger FR erforderlich, um eine ausreichende Eindringtiefe bei gleichzeitig adäquater Kontrastverstärkung zu erreichen. Purpose: Conventional transcranial ultrasound perfusion imaging (UPI) depends on bolus injection and is limited to triggered imaging. To improve our set-ups, we compared two imaging modalities with two different frame rates (FR) and mechanical indices (MI), intending to approach conditions more similar to real time imaging in order to increase parameter precision. Materials and Methods: Fifteen healthy volunteers were investigated twice with UPI after i. v. administration of 1 ml of SonoVue®: first, with a high MI (1.6) and a low FR (0.67 Hz)) and second, with a low MI (1.0) and a high FR (5 Hz). Apart from visual analysis, time-intensity curves were calculated from three regions of interest (ROI) and peak intensity (PI), time to PI (TP), and area-under-the-curve (AUC) were compared between the two imaging modalities. Results: Visually, only scarce contrast enhancement was observed in 10/15 probands, and penetration depth was markedly lower at the low MI/high FR setting, while the high MI/low FR setting lead to very intense enhancement in 13/15 individuals. Signal-to-noise-ratio was higher at the low MI/high FR setting. TP was not significantly different between the two set-ups (p > 0.05). PI and AUC were significantly lower at the low MI/high FR setting (p≤ 0.001), and both parameters correlated well in corresponding ROIs (p < 0.05 or < 0.01 in 8/9 ROIs). Parameter images reflected the differences of these two semi-quantitative parameters. Conclusion: In patients with excellent bone windows, the new set-up seems to offer highly precise kinetic analysis with an excellent signal-to-noise ratio. In the majority of patients, however, conventional transcranial UPI is limited to high MI and a resulting rather low FR to allow sufficient penetration depth and contrast enhancement.
- 16 July 2007
- Published by Georg Thieme Verlag KG in Ultraschall in der Medizin - European Journal of Ultrasound
- Vol. 28 (04) , 380-386
Transcranial Ultrasound Perfusion Imaging: Implementation of a Low MI and a High Frame Rate
Ziel: Die konventionelle transkranielle Perfusionssonographie (ultrasound perfusion imaging, UPI) basiert auf der Bolusinjektion eines Echosignalverstärkers und zeitgetriggerter Bildaufnahme. Zur Optimierung unserer Geräteeinstellungen verglichen wir zwei unterschiedliche Bildraten (frame rate, FR) und Sendeleistungen (angegeben als mechanical index, MI) mit dem Ziel, echtzeitähnliche Untersuchungsbedingungen zu erreichen und hiermit die Berechnung von kinetischen Parametern zu präzisieren. Material und Methoden: Nach Gabe von 1 ml SonoVue® wurde bei 15 gesunden Probanden eine UPI je zweimal durchgeführt: einmal mit hohem MI (1,6) und niedriger FR (0,67 Hz) und zum zweiten mit niedrigem MI (1,0) und hoher FR (5 Hz). Neben der visuellen Analyse wurden aus 3 Hirnregionen (region of interest, ROI) Zeitintensitätskurven mit Maximalintensität (peak intensity, PI), Zeit bis zur PI (time-to-peak-intensity, TP [sec]) und der Fläche unter der Kurve (area-under-the-curve, AUC) errechnet und zwischen den beiden Methoden verglichen. Ergebnisse: Die visuelle Analyse ergab eine nur mäßige Kontrastverstärkung bei 10/15 Probanden und eine deutlich geringere Eindringtiefe mit niedrigem MI/hoher FR, während mit hohem MI/niedriger FR eine starke Kontrastverstärkung bei 13/15 Probanden erreicht wurde. Das Signal-Rausch-Verhältnis war höher bei niedrigem MI/hoher FR. Die TP war bei beiden Methoden vergleichbar (p > 0,05). PI und AUC waren signifikant niedriger bei niedrigem MI/hoher FR (p≤ 0,001), und beide Parameter korrelierten gut in korrespondierenden ROIs (p < 0,05 oder < 0,01 in 8/9 ROIs). Die Parameterbilder spiegelten die Unterschiede beider Methoden wider. Schlussfolgerung: Die neue Geräteeinstellung erlaubt eine hochpräzise kinetische Analyse mit sehr gutem Signal-Rausch-Verhältnis bei Patienten mit exzellentem Knochenfenster. Bei der Mehrzahl der Patienten ist allerdings die konventionelle transkranielle UPI mit hohem MI und dementsprechend niedriger FR erforderlich, um eine ausreichende Eindringtiefe bei gleichzeitig adäquater Kontrastverstärkung zu erreichen. Purpose: Conventional transcranial ultrasound perfusion imaging (UPI) depends on bolus injection and is limited to triggered imaging. To improve our set-ups, we compared two imaging modalities with two different frame rates (FR) and mechanical indices (MI), intending to approach conditions more similar to real time imaging in order to increase parameter precision. Materials and Methods: Fifteen healthy volunteers were investigated twice with UPI after i. v. administration of 1 ml of SonoVue®: first, with a high MI (1.6) and a low FR (0.67 Hz)) and second, with a low MI (1.0) and a high FR (5 Hz). Apart from visual analysis, time-intensity curves were calculated from three regions of interest (ROI) and peak intensity (PI), time to PI (TP), and area-under-the-curve (AUC) were compared between the two imaging modalities. Results: Visually, only scarce contrast enhancement was observed in 10/15 probands, and penetration depth was markedly lower at the low MI/high FR setting, while the high MI/low FR setting lead to very intense enhancement in 13/15 individuals. Signal-to-noise-ratio was higher at the low MI/high FR setting. TP was not significantly different between the two set-ups (p > 0.05). PI and AUC were significantly lower at the low MI/high FR setting (p≤ 0.001), and both parameters correlated well in corresponding ROIs (p < 0.05 or < 0.01 in 8/9 ROIs). Parameter images reflected the differences of these two semi-quantitative parameters. Conclusion: In patients with excellent bone windows, the new set-up seems to offer highly precise kinetic analysis with an excellent signal-to-noise ratio. In the majority of patients, however, conventional transcranial UPI is limited to high MI and a resulting rather low FR to allow sufficient penetration depth and contrast enhancement.
- 1 September 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 103 (3) , 564-566
Sonographic detection and follow up of an atypical pineal cyst: a comparison with magnetic resonance imaging Case report
The incidental ultrasonographic detection of an asymptomatic cystic pineal lesion in a young woman is described and compared with findings on magnetic resonance (MR) images. Follow-up studies obtained using both imaging modalities are presented. The results indicate that transcranial ultrasonography may represent an easy and cost-effective imaging technique for follow up of cystic lesions of the pineal gland, especially in patients unable to undergo MR imaging.
- 1 September 2005
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 103 (3) , 564-566
Sonographic detection and follow up of an atypical pineal cyst: a comparison with magnetic resonance imaging Case report
The incidental ultrasonographic detection of an asymptomatic cystic pineal lesion in a young woman is described and compared with findings on magnetic resonance (MR) images. Follow-up studies obtained using both imaging modalities are presented. The results indicate that transcranial ultrasonography may represent an easy and cost-effective imaging technique for follow up of cystic lesions of the pineal gland, especially in patients unable to undergo MR imaging.
- 1 May 2005
- Published by Wolters Kluwer Health in Stroke
- Vol. 36 (5) , 976-979
Assessment of Dural Arteriovenous Fistulae by Transcranial Color-Coded Duplex Sonography
Background and Purpose— To study hemodynamic changes and to determine the value of contrast-enhanced transcranial color-coded sonography (TCCS) for the evaluation of dural arteriovenous fistulae (DAVF) before and after transcatheter embolization. Methods— Twenty-four patients (mean age 61±11 years) with occipitally located DAVF were studied with contrast-enhanced TCCS using the transtemporal bone window in transverse-axial and coronal insonation planes. Blood flow velocity measurements of all depictable basal cerebral veins and sinuses were obtained before and after transcatheter embolization. Pretreatment and post-treatment flow velocity values were compared. Results of digital subtraction angiography (DSA) were compared with sonographic findings. Results— Four of the 24 patients (17%) could not be studied because of an insufficient temporal bone window. In all remaining patients (n=20), draining veins/sinuses could be identified because of pathologically increased blood flow velocities with peak systolic flow velocities of >50 cm/s. Of the 27 draining vessels depicted by DSA, TCCS correctly identified 25 (93%): the basal vein (3 of 3), the straight sinus (3 of 3), the superior sagittal sinus (1 of 3), the transverse sinus (9), the sigmoid sinus (4), and the superior petrosal sinus (5/5). However, TCCS failed to depict supplementary drainage via cortical veins. After transcatheter embolization, mean reduction of blood flow velocity was 44±18% ( P Conclusions— Contrast-enhanced TCCS is a promising technique for monitoring embolization of DAVF, follow-up after complete fistula occlusion, and may even be useful as a screening tool in patients with pulsatile tinnitus.
- 1 May 2005
- Published by Wolters Kluwer Health in Stroke
- Vol. 36 (5) , 976-979
Assessment of Dural Arteriovenous Fistulae by Transcranial Color-Coded Duplex Sonography
Background and Purpose— To study hemodynamic changes and to determine the value of contrast-enhanced transcranial color-coded sonography (TCCS) for the evaluation of dural arteriovenous fistulae (DAVF) before and after transcatheter embolization. Methods— Twenty-four patients (mean age 61±11 years) with occipitally located DAVF were studied with contrast-enhanced TCCS using the transtemporal bone window in transverse-axial and coronal insonation planes. Blood flow velocity measurements of all depictable basal cerebral veins and sinuses were obtained before and after transcatheter embolization. Pretreatment and post-treatment flow velocity values were compared. Results of digital subtraction angiography (DSA) were compared with sonographic findings. Results— Four of the 24 patients (17%) could not be studied because of an insufficient temporal bone window. In all remaining patients (n=20), draining veins/sinuses could be identified because of pathologically increased blood flow velocities with peak systolic flow velocities of >50 cm/s. Of the 27 draining vessels depicted by DSA, TCCS correctly identified 25 (93%): the basal vein (3 of 3), the straight sinus (3 of 3), the superior sagittal sinus (1 of 3), the transverse sinus (9), the sigmoid sinus (4), and the superior petrosal sinus (5/5). However, TCCS failed to depict supplementary drainage via cortical veins. After transcatheter embolization, mean reduction of blood flow velocity was 44±18% ( P Conclusions— Contrast-enhanced TCCS is a promising technique for monitoring embolization of DAVF, follow-up after complete fistula occlusion, and may even be useful as a screening tool in patients with pulsatile tinnitus.
- 1 October 2004
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 101 (4) , 700-703
Perfusion imaging of high-grade gliomas: a comparison between contrast harmonic and magnetic resonance imaging
✓ Transcranial contrast harmonic (CH) imaging is emerging as a promising tool for the evaluation of brain perfusion. The authors report on two cases of histologically proven high-grade gliomas evaluated using CH imaging in comparison to perfusion magnetic resonance (pMR) imaging. In both cases, pMR imaging results demonstrated a massive decrease in signal intensity and an elevated regional cerebral blood volume (rCBV) in the tumor region; however, signal decrease was less prominent and rCBV was lower in healthy brain tissue. In one patient, the rCBV ratio of tumor/brain was 5.0 and the maximal signal decay occurred 3.1 times deeper in the tumor than in the healthy brain tissue. Results of an ultrasonography examination using CH imaging revealed similar data: the tumor/brain ratio for the area under the curve, a parameter corresponding to rCBV, was 4.1. The maximal signal intensity in the tumor was 3.3 times greater than in adjacent healthy brain. Comparable data were obtained in a second patient. Taken together, these findings indicate that CH imaging may be a valuable alternative to pMR imaging. This new, cost-effective bedside ultrasonic technique could be helpful not only as a means of noninvasive staging of gliomas but also as a follow-up imaging modality to evaluate postoperative tumor recurrence or response to antiangiogenic therapy.
- 1 October 2004
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 101 (4) , 700-703
Perfusion imaging of high-grade gliomas: a comparison between contrast harmonic and magnetic resonance imaging
✓ Transcranial contrast harmonic (CH) imaging is emerging as a promising tool for the evaluation of brain perfusion. The authors report on two cases of histologically proven high-grade gliomas evaluated using CH imaging in comparison to perfusion magnetic resonance (pMR) imaging. In both cases, pMR imaging results demonstrated a massive decrease in signal intensity and an elevated regional cerebral blood volume (rCBV) in the tumor region; however, signal decrease was less prominent and rCBV was lower in healthy brain tissue. In one patient, the rCBV ratio of tumor/brain was 5.0 and the maximal signal decay occurred 3.1 times deeper in the tumor than in the healthy brain tissue. Results of an ultrasonography examination using CH imaging revealed similar data: the tumor/brain ratio for the area under the curve, a parameter corresponding to rCBV, was 4.1. The maximal signal intensity in the tumor was 3.3 times greater than in adjacent healthy brain. Comparable data were obtained in a second patient. Taken together, these findings indicate that CH imaging may be a valuable alternative to pMR imaging. This new, cost-effective bedside ultrasonic technique could be helpful not only as a means of noninvasive staging of gliomas but also as a follow-up imaging modality to evaluate postoperative tumor recurrence or response to antiangiogenic therapy.