UKUlrike Krumsdorf

Ulrike Krumsdorf

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ulrike Krumsdorf has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 1 February 2013
      • Vol. 25  (2) , 69-72

    Percutaneous edge-to-edge repair of mitral regurgitation as a bail-out strategy in critically ill patients.

    by Sven T Pleger, Emmanuel Chorianopoulos, Ulrike Krumsdorf, Hugo A Katus, Raffi Bekeredjian

    Percutaneous edge-to-edge mitral valve repair using the MitraClip device has evolved as a new tool for the treatment of severe mitral valve regurgitation. This technique has been evaluated in both surgical low- and high-risk patients. The aim of this study was to assess the feasibility and efficacy of MitraClip implantation in critically ill, unstable patients with severe mitral regurgitation who would persistently need inotropes or who could not be weaned from a ventilator. Six patients with the above-mentioned criteria were identified among the 87 patients that were treated with MitraClip implantation between October 2009 and January 2012 at our institution. All patients were considered as surgical high-risk patients with a Society of Thoracic Surgeons (STS) score between 8.0% and 56.9%. In all patients, MitraClip implantation was successfully achieved without relevant complications. More importantly, all patients showed rapid clinical improvement within a few days, allowing discontinuation of inotropes and/or weaning from a respirator and finally a transfer to a regular ward or discharge home. These data emphasize the safety profile of the MitraClip system in multimorbid, high-risk patients. In addition, it demonstrates the applicability of this treatment in unstable and critically ill conditions as a tool for acute stabilization.


    • 1 June 2012
      • Vol. 24  (6) , 282-6

    C-reactive protein kinetics and its prognostic value after transfemoral aortic valve implantation.

    by Ulrike Krumsdorf, Emmanuel Chorianopoulos, Sven T Pleger, Klaus Kallenbach, Matthias Karck, Hugo A Katus, Raffi Bekeredjian

    Transcatheter aortic valve implantation (TAVI) has become an established therapeutic option in high-risk patients with severe aortic valve stenosis. The potential threat of a postinterventional infection is one of several life-threatening complications. We have analyzed C-reactive protein levels in all patients who underwent successful transfemoral aortic valve implantation between July 2009 and January 2011. CRP and leukocyte counts were measured within 24 hours prior to implantation and daily up to 14 days after implantation. Patients with CRP levels above 109 mg/L (75th percentile; normal range 6.4 mg/L) and elevated peak (>102 mg/L) CRP values were associated with higher 30-day mortality. In conclusion, CRP elevation after TAVI should be expected to peak on day 3. An infection should be taken into account if CRP increases above 110 mg/L and if patients show other signs of infection. Elevated CRP at baseline and at day 3 is associated with higher 30-day mortality.


  • Acute Safety and 30-Day Outcome After Percutaneous Edge-to-Edge Repair of Mitral Regurgitation in Very High-Risk Patients

    by Sven T. Pleger, Derliz Mereles, Marius Schulz-Schönhagen, Ulrike Krumsdorf, Emmanuel Chorianopoulos, Wolfgang Rottbauer, Hugo A. Katus, Raffi Bekeredjian


    • 1 March 2011
      • Vol. 20  (2) , 146-8

    Large atrial thrombus formation after MitraClip implantation: is anticoagulation mandatory?

    by Raffi Bekeredjian, Derliz Mereles, Sven Pleger, Ulrike Krumsdorf, Hugo A Katus, Wolfgang Rottbauer

    Percutaneous mitral valve repair with the MitraClip system has evolved as a promising new technique for the non-surgical treatment of mitral regurgitation (MR). To date, few major adverse events have been reported in initial studies with this technique. The case is reported of a 70-year-old patient who underwent successful MitraClip implantation. Routine pre-discharge transesophageal echocardiography on day 5 after implantation showed large thrombus formation in the left atrium (posterolateral wall) and on the right atrial side of the septum. The patient had not received any anticoagulation after clip implantation, and did not have any monitored episodes of atrial fibrillation prior to the scheduled discharge day. It is concluded that mandatory anticoagulation for at least one month should be considered in patients undergoing MitraClip implantation.


  • Open Access

    Percutaneous Aortic “Valve in Valve” Implantation for Severe Aortic Regurgitation in a Degenerated Bioprosthesis

    by Ulrike Krumsdorf, Raffi Bekeredjian, Grigorios Korosoglou, Joerg Kreuzer, Benjamin J. Rieck, Klaus Kallenbach, Hugo A. Katus, Wolfgang Rottbauer