Erwin Stolz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Erwin Stolz has a total of 110 co-authors. Here are the top co-authors by number of shared publications:
Manfred Kaps
Department of Neurology, Justus-Liebig University, Giessen, Germany
16 shared publicationsTibo Gerriets
Department of Neurology, Justus-Liebig University, Giessen, Germany
11 shared publications- Manfred Kaps
Klinik und Poliklinik für Neurologie, Universitätsklinikum Giessen, Giessen
6 shared publications Anousha Rahimi
Dept. of Neurology, Katholisches Klinikum, Haus St. Josef, Koblenz, Germany
4 shared publicationsJörg Kraus
Department of Neurology, Justus‐Liebig‐University, Giessen, Germany (ES, BCF, TG, FB, MK); University of Applied Sciences, Giessen, Germany (OH); and Paracelsus Medical University, Christian‐Doppler‐Clinic, Salzburg, Austria (JK)
4 shared publicationsM. Kaps
Neurologische Klinik der Justus-Liebig-Universität Gießen
4 shared publications
Latest Publications
- 1 November 2022
- Published by Hogrefe Publishing Group in Vasa
- Vol. 51 (6) , 329-332
Intracranial pressure and veins
Summary: This review summarizes the relationship between intracranial pressure and the venous system as far as ultrasound methods are concerned. Although the pressure in cortical veins is tightly and linearly coupled to the intracranial pressure, venous flow velocities in the basal veins are not. However, venous flow velocities reflect better the local cerebral blood flow than measurements in arteries. Therefore, they correlate better with clinical outcome in head trauma and subarachnoid hemorrhage. Transorbital sonography with measurement of the optic nerve sheath diameter and optic disk elevation has evolved to a valuable point of care diagnostic tool in idiopathic intracranial hypertension. In cerebral vein and sinus thrombosis ultrasound is at best a supplementary diagnostic tool, which may have a value in patient follow-up.
- 1 November 2022
- Published by Hogrefe Publishing Group in Vasa
- Vol. 51 (6) , 329-332
Intracranial pressure and veins
Summary: This review summarizes the relationship between intracranial pressure and the venous system as far as ultrasound methods are concerned. Although the pressure in cortical veins is tightly and linearly coupled to the intracranial pressure, venous flow velocities in the basal veins are not. However, venous flow velocities reflect better the local cerebral blood flow than measurements in arteries. Therefore, they correlate better with clinical outcome in head trauma and subarachnoid hemorrhage. Transorbital sonography with measurement of the optic nerve sheath diameter and optic disk elevation has evolved to a valuable point of care diagnostic tool in idiopathic intracranial hypertension. In cerebral vein and sinus thrombosis ultrasound is at best a supplementary diagnostic tool, which may have a value in patient follow-up.
- Open Access
- 1 July 2016
- Published by Springer Nature in BMC Neurology
- Vol. 16 (1) , 1
Erratum to: Feasibility and usefulness of ultrasonography in idiopathic intracranial hypertension or secondary intracranial hypertension
- 1 July 2016
- Published by Springer Nature in BMC Neurology
- Vol. 16 (1) , 1
Open AccessErratum to: Feasibility and usefulness of ultrasonography in idiopathic intracranial hypertension or secondary intracranial hypertension
- Open Access
- 2 June 2016
- Published by Springer Nature in BMC Neurology
- Vol. 16 (1) , 1-7
Feasibility and usefulness of ultrasonography in idiopathic intracranial hypertension or secondary intracranial hypertension
Transorbital sonography (TOS) has been proven to be able to non-invasively detect elevated intracranial pressure. In this condition TOS shows an increase in optic nerve sheath diameter (ONSD). It has been suggested that internal jugular vein valve insufficiency (IJVVI) may represent a factor contributing to the pathogenesis of idiopathic intracranial hypertension (IIH). The aim of this study was to investigate whether patients with IIH or secondary IH have higher ONSD values and higher frequency of IJVVI compared to subjects without IH. Twenty-one patients with newly diagnosed IIH or secondary IH were prospectively evaluated and compared with 21 age, gender and BMI-matched controls. Experienced vascular sonographers used B-mode TOS to evaluate ONSD, optic nerve diameter (OND) and IJVVI. CSF opening pressures were also measured. ONSD values were significantly higher in patients (6.50 ± 0.67) than controls (5.73 ± 0.66; p < 0.0001). No differences were found in OND values between patients (2.99 ± 0.26) and controls (2.93 ± 0.41; p = 0.574). No correlation was demonstrated between ONSD and CSF opening pressure (r = 0,086) (p = 0.73). No difference in frequency of IJVVI between patients (11/42 valves, 26 %) and controls (9/42, 21 %) was observed (p = 0.777). Increased ONSD values detected by TOS support the diagnosis of IH. Our results do not support the hypothesis of a venous congestion as a potential factor contributing to the pathogenesis of IIH. Not applicable. Observational, non-interventional study.
- 2 June 2016
- Published by Springer Nature in BMC Neurology
- Vol. 16 (1) , 1-7
Open AccessFeasibility and usefulness of ultrasonography in idiopathic intracranial hypertension or secondary intracranial hypertension
Transorbital sonography (TOS) has been proven to be able to non-invasively detect elevated intracranial pressure. In this condition TOS shows an increase in optic nerve sheath diameter (ONSD). It has been suggested that internal jugular vein valve insufficiency (IJVVI) may represent a factor contributing to the pathogenesis of idiopathic intracranial hypertension (IIH). The aim of this study was to investigate whether patients with IIH or secondary IH have higher ONSD values and higher frequency of IJVVI compared to subjects without IH. Twenty-one patients with newly diagnosed IIH or secondary IH were prospectively evaluated and compared with 21 age, gender and BMI-matched controls. Experienced vascular sonographers used B-mode TOS to evaluate ONSD, optic nerve diameter (OND) and IJVVI. CSF opening pressures were also measured. ONSD values were significantly higher in patients (6.50 ± 0.67) than controls (5.73 ± 0.66; p < 0.0001). No differences were found in OND values between patients (2.99 ± 0.26) and controls (2.93 ± 0.41; p = 0.574). No correlation was demonstrated between ONSD and CSF opening pressure (r = 0,086) (p = 0.73). No difference in frequency of IJVVI between patients (11/42 valves, 26 %) and controls (9/42, 21 %) was observed (p = 0.777). Increased ONSD values detected by TOS support the diagnosis of IH. Our results do not support the hypothesis of a venous congestion as a potential factor contributing to the pathogenesis of IIH. Not applicable. Observational, non-interventional study.
- Open Access
- 1 June 2015
- Vol. 3 (10) , 9-138
Sinus thrombosis-do animal models really cover the clinical syndrome?
Sinus thrombosis—do animal models really cover the clinical syndrome?
- 1 June 2015
- Vol. 3 (10) , 9-138
Open AccessSinus thrombosis-do animal models really cover the clinical syndrome?
Sinus thrombosis—do animal models really cover the clinical syndrome?
- 14 March 2014
- Published by Springer Nature in Neurological Sciences
- Vol. 35 (8) , 1281-1285
Histopathological effects of different therapy strategies in experimental sinus thrombosis
The optimal treatment for cerebral venous thrombosis is still under debate. The histological consequences of different treatments have not been systematically studied and may be of value in this debate. Thrombosis of the superior sagittal sinus was induced in rats by topical application of ferric chloride. Animals were treated 6 h after operation with subcutaneous injection of 450 IU/kg enoxaparin twice daily (n = 10), with 10 mg recombinant tissue plasminogen activator (rt-PA)/kg (n = 12), and with 6 mg abciximab/kg (n = 10). Eleven animals were treated with saline (controls), and four animals were sham-operated without thrombosis induction. Animals were killed on day 7. Coronal brain slices were stained with hematoxylin–eosin (HE) and against glial fibrillary acidic protein (GFAP), and factor VIII. Histology was quantified in parasagittal and temporal regions of interest. Compared with controls, counts of pyknotic neurons on HE stain were significantly lower in the enoxaparin group. Counts for GFAP-expressing astrocytes were highest in the enoxaparin (p p p p
- 14 March 2014
- Published by Springer Nature in Neurological Sciences
- Vol. 35 (8) , 1281-1285
Histopathological effects of different therapy strategies in experimental sinus thrombosis
The optimal treatment for cerebral venous thrombosis is still under debate. The histological consequences of different treatments have not been systematically studied and may be of value in this debate. Thrombosis of the superior sagittal sinus was induced in rats by topical application of ferric chloride. Animals were treated 6 h after operation with subcutaneous injection of 450 IU/kg enoxaparin twice daily (n = 10), with 10 mg recombinant tissue plasminogen activator (rt-PA)/kg (n = 12), and with 6 mg abciximab/kg (n = 10). Eleven animals were treated with saline (controls), and four animals were sham-operated without thrombosis induction. Animals were killed on day 7. Coronal brain slices were stained with hematoxylin–eosin (HE) and against glial fibrillary acidic protein (GFAP), and factor VIII. Histology was quantified in parasagittal and temporal regions of interest. Compared with controls, counts of pyknotic neurons on HE stain were significantly lower in the enoxaparin group. Counts for GFAP-expressing astrocytes were highest in the enoxaparin (p p p p
- Open Access
- 10 June 2011
- Published by Springer Nature in BMC Neurology
- Vol. 11 (1) , 69
Cerebral vein thrombosis: clinical manifestation and diagnosis
Cerebral venous thrombosis (CVT) is a disease with a wide spectrum of symptoms and severity. In this study we analysed the predictive value of clinical signs and symptoms and the contribution of D-dimer measurements for diagnosis.
- 10 June 2011
- Published by Springer Nature in BMC Neurology
- Vol. 11 (1) , 69
Open AccessCerebral vein thrombosis: clinical manifestation and diagnosis
Cerebral venous thrombosis (CVT) is a disease with a wide spectrum of symptoms and severity. In this study we analysed the predictive value of clinical signs and symptoms and the contribution of D-dimer measurements for diagnosis.
- Open Access
- 29 December 2010
- Published by Springer Nature in BMC Neurology
- Vol. 10 (1) , 123
Decrease in shunt volume in patients with cryptogenic stroke and patent foramen ovale
In patients with patent foramen ovale (PFO) there is evidence supporting the hypothesis of a change in right-to-left shunt (RLS) over time. Proven, this could have implications for the care of patients with PFO and a history of stroke. The following study addressed this hypothesis in a cohort of patients with stroke and PFO.
- 29 December 2010
- Published by Springer Nature in BMC Neurology
- Vol. 10 (1) , 123
Open AccessDecrease in shunt volume in patients with cryptogenic stroke and patent foramen ovale
In patients with patent foramen ovale (PFO) there is evidence supporting the hypothesis of a change in right-to-left shunt (RLS) over time. Proven, this could have implications for the care of patients with PFO and a history of stroke. The following study addressed this hypothesis in a cohort of patients with stroke and PFO.
- 7 December 2010
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 41 (04) , 253-257
Sonografie der Substantia nigra – Technik und klinische Implikationen
Die transkranielle Parenchymsonografie (TCS) stellt eine wertvolle ergänzende Methode bei der Diagnostik von Bewegungsstörungen dar. Über 90% der Patienten mit idiopathischem Parkinson-Syndrom (IPS) weisen sonografisch eine Vergrößerung der Fläche der Substantia nigra (SN) auf. Dahingegen findet man nur bei bis zu 10% der Gesunden eine veränderte Echogenität der SN. Die SN-Hyperechogenität entspricht einem Suszeptibilitätsmarker für die Parkinson-Erkrankung, sie ist jedoch kein Verlaufsparameter der striatonigralen Degeneration. Bei der Differenzierung des IPS von atypischen Parkinson-Syndromen oder essentiellem Tremor ist neben der Echogenität der SN die Beurteilung der Echogenität des Nucleus lentiformis, des Nucleus caudatus und der Ventrikelweite hilfreich. In diesem Artikel werden die Methodik der Parenchymsonografie, ihr Stellenwert im Vergleich zu anderen bildgebenden Verfahren und ihre Anwendung bei der Differenzialdiagnostik von Bewegungsstörungen erläutert. In movement disorders transcranial ultrasound (TCS) represents an important diagnostic method. In more than 90% of patients with idiopathic Parkinson's disease (IPD) an increase of the echogenicity of the substantia nigra (SN) is found. In contrast, in healthy individuals a change of the SN echogenic signal is shown in only up to 10%. Whereas SN hyperechogenicity seems to disclose a susceptibility for IPD, it is not a marker for the progression of the disease. In the differential diagnosis of IPD and atypical Parkinsonian syndromes or essential tremor, additional sonografic parameters such as echogenicity of the nucleus lentiformis, nucleus caudatus and width of ventricles are useful. This article elucidates the methodological approach, its value in comparison with other diagnostic methods and its implementation in the diagnostic work-up of movement disorders.
- 7 December 2010
- Published by Georg Thieme Verlag KG in Klinische Neurophysiologie
- Vol. 41 (04) , 253-257
Sonografie der Substantia nigra – Technik und klinische Implikationen
Die transkranielle Parenchymsonografie (TCS) stellt eine wertvolle ergänzende Methode bei der Diagnostik von Bewegungsstörungen dar. Über 90% der Patienten mit idiopathischem Parkinson-Syndrom (IPS) weisen sonografisch eine Vergrößerung der Fläche der Substantia nigra (SN) auf. Dahingegen findet man nur bei bis zu 10% der Gesunden eine veränderte Echogenität der SN. Die SN-Hyperechogenität entspricht einem Suszeptibilitätsmarker für die Parkinson-Erkrankung, sie ist jedoch kein Verlaufsparameter der striatonigralen Degeneration. Bei der Differenzierung des IPS von atypischen Parkinson-Syndromen oder essentiellem Tremor ist neben der Echogenität der SN die Beurteilung der Echogenität des Nucleus lentiformis, des Nucleus caudatus und der Ventrikelweite hilfreich. In diesem Artikel werden die Methodik der Parenchymsonografie, ihr Stellenwert im Vergleich zu anderen bildgebenden Verfahren und ihre Anwendung bei der Differenzialdiagnostik von Bewegungsstörungen erläutert. In movement disorders transcranial ultrasound (TCS) represents an important diagnostic method. In more than 90% of patients with idiopathic Parkinson's disease (IPD) an increase of the echogenicity of the substantia nigra (SN) is found. In contrast, in healthy individuals a change of the SN echogenic signal is shown in only up to 10%. Whereas SN hyperechogenicity seems to disclose a susceptibility for IPD, it is not a marker for the progression of the disease. In the differential diagnosis of IPD and atypical Parkinsonian syndromes or essential tremor, additional sonografic parameters such as echogenicity of the nucleus lentiformis, nucleus caudatus and width of ventricles are useful. This article elucidates the methodological approach, its value in comparison with other diagnostic methods and its implementation in the diagnostic work-up of movement disorders.
- Open Access
- 28 May 2010
- Published by Springer Nature in BMC Neurology
- Vol. 10 (1) , 36
Evaluation of the middle cerebral artery occlusion techniques in the rat by in-vitro 3-dimensional micro- and nano computed tomography
Animal models of focal cerebral ischemia are widely used in stroke research. The purpose of our study was to evaluate and compare the cerebral macro- and microvascular architecture of rats in two different models of permanent middle cerebral artery occlusion using an innovative quantitative micro- and nano-CT imaging technique.
- 28 May 2010
- Published by Springer Nature in BMC Neurology
- Vol. 10 (1) , 36
Open AccessEvaluation of the middle cerebral artery occlusion techniques in the rat by in-vitro 3-dimensional micro- and nano computed tomography
Animal models of focal cerebral ischemia are widely used in stroke research. The purpose of our study was to evaluate and compare the cerebral macro- and microvascular architecture of rats in two different models of permanent middle cerebral artery occlusion using an innovative quantitative micro- and nano-CT imaging technique.
- 7 March 2010
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 109 (4) , 691-697
Active regulation of cerebral venous tone: simultaneous arterial and venous transcranial Doppler sonography during a Valsalva manoeuvre
The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 ± 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 ± 0.29 vs. 16.0 ± 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.
- 7 March 2010
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 109 (4) , 691-697
Active regulation of cerebral venous tone: simultaneous arterial and venous transcranial Doppler sonography during a Valsalva manoeuvre
The aim of this study was to analyse the cerebral venous outflow in relation to the arterial inflow during a Valsalva manoeuvre (VM). In 19 healthy volunteers (mean age 24.1 ± 2.6 years), the middle cerebral artery (MCA) and the straight sinus (SRS) were insonated by transcranial Doppler sonography. Simultaneously the arterial blood pressure was recorded using a photoplethysmographic method. Two VM of 10 s length were performed per participant. Tracings of the variables were then transformed to equidistantly re-sampled data. Phases of the VM were analysed regarding the increase of the flow velocities and the latency to the peak. The typical four phases of the VM were also found in the SRS signal. The relative flow velocity (FV) increase was significantly higher in the SRS than in the MCA for all phases, particularly that of phase IV (p < 0.01). Comparison of the time latency of the VM phases of the MCA and SRS only showed a significant difference for phase I (p < 0.01). In particular, there was no significant difference for phase IV (15.8 ± 0.29 vs. 16.0 ± 0.28 s). Alterations in venous outflow in phase I are best explained by a cross-sectional change of the lumen of the SRS, while phases II and III are compatible with a Starling resistor. However, the significantly lager venous than the arterial overshoot in phase IV may be explained by the active regulation of the venous tone.