Carmen W. Huie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Carmen W. Huie has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Wing Hong Chan
Department of Chemistry
4 shared publications Albert W. M. Lee
Department of Chemistry and The Central Laboratory of the Institute of Molecular Technology for Drug Discovery and Synthesis*, Hong Kong Baptist University, Kowloon Tong, Hong Kong, China
3 shared publicationsQi Li
Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong, P R China
3 shared publicationsTom M. H. Choy
Department of Chemistry and The Central Laboratory of the Institute of Molecular Technology for Drug Discovery and Synthesis, Hong Kong Baptist University, Kowloon Tong, Hong Kong, China
3 shared publications- Chi Kwong Chang
Department of Chemistry, Michigan State University, E. Lansing, USA
2 shared publications Li Jia
Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong; Fax: 852–2339–7348
2 shared publications
Latest Publications
- 30 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (21) , 4219-4229
Coupling of acetonitrile deproteinization and salting‐out extraction with acetonitrile stacking for biological sample clean‐up and the enrichment of hydrophobic compounds (porphyrins) in capillary electrophoresis
A new sample pretreatment approach in CE was developed for concurrent biological sample clean‐up and the concentration of hydrophobic compounds based on the combination of ACN deproteinization with salting‐out extraction. Further enhancement in concentration detection sensitivity was achieved by coupling (offline) salting‐out extraction with an online CE sample enrichment technique known as “ACN stacking”. By optimizing the pH of salting‐out extraction, a number of model compounds (hydrophobic porphyrins with clinical significances), i.e. zinc‐protoporphyrin, protoporphyrin, and coproporphyrin (CP) III and I, can be efficiently extracted from the aqueous sample into a smaller volume organic solvent (ACN) phase and an enrichment factor of ca. 100 can be obtained. The pressure injection of the enriched ACN phase (containing ca.1% NaCl) into the CE capillary at 10% capillary volume resulted in additional concentration of the various hydrophobic porphyrins, allowing for a combined enrichment factor of ca.1000 to be obtained. Calibration curves obtained for the determination of a pair of positional isomers with significant diagnostic value, urinary CPIII and CPI, were found to be linear between 10–300 ng/mL (with R2 = 0.999), and LODs (absorbance detection at 400 nm) were ca. 0.8 ng/mL (1.1 nmol/L of CPIII or CPI). Based on a single salting‐out extraction, intraday precisions (nine consecutive injections) for both CPIII and CPI (at spiked concentrations of 10–300 ng/mL into urine) in terms of migration time and peak area were found to be within the range of 0.2–0.5 and 0.8–2.9%, respectively.
- 30 October 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (21) , 4219-4229
Coupling of acetonitrile deproteinization and salting‐out extraction with acetonitrile stacking for biological sample clean‐up and the enrichment of hydrophobic compounds (porphyrins) in capillary electrophoresis
A new sample pretreatment approach in CE was developed for concurrent biological sample clean‐up and the concentration of hydrophobic compounds based on the combination of ACN deproteinization with salting‐out extraction. Further enhancement in concentration detection sensitivity was achieved by coupling (offline) salting‐out extraction with an online CE sample enrichment technique known as “ACN stacking”. By optimizing the pH of salting‐out extraction, a number of model compounds (hydrophobic porphyrins with clinical significances), i.e. zinc‐protoporphyrin, protoporphyrin, and coproporphyrin (CP) III and I, can be efficiently extracted from the aqueous sample into a smaller volume organic solvent (ACN) phase and an enrichment factor of ca. 100 can be obtained. The pressure injection of the enriched ACN phase (containing ca.1% NaCl) into the CE capillary at 10% capillary volume resulted in additional concentration of the various hydrophobic porphyrins, allowing for a combined enrichment factor of ca.1000 to be obtained. Calibration curves obtained for the determination of a pair of positional isomers with significant diagnostic value, urinary CPIII and CPI, were found to be linear between 10–300 ng/mL (with R2 = 0.999), and LODs (absorbance detection at 400 nm) were ca. 0.8 ng/mL (1.1 nmol/L of CPIII or CPI). Based on a single salting‐out extraction, intraday precisions (nine consecutive injections) for both CPIII and CPI (at spiked concentrations of 10–300 ng/mL into urine) in terms of migration time and peak area were found to be within the range of 0.2–0.5 and 0.8–2.9%, respectively.
- 7 March 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (5-6) , 1104-1111
Fluorescence imaging of sample zone narrowing and dispersion in a glass microchip: The effects of organic solvent (acetonitrile)–salt mixtures in the sample matrix and surfactant micelles in the running buffer
A mismatch in the EOF velocities between the sample zone and running buffer region is known to generate pressure‐driven, parabolic flow profile of the sample plug in electrokinetic separation systems. In the present study, video fluorescence microscopy was employed to capture real‐time dynamics of the sample plug (containing fluorescein as the probe molecule) in a discontinuous conductivity system within a glass microchip, in which the sample matrix consisted of a mixture of ACN and salt (NaCl), and the running buffer contained sodium cholate (SC) micelles as the pseudo‐stationary phase (i.e., performing “ACN stacking” in the mode of MEKC). Upon application of the separation voltage, the video images revealed that zone narrowing and broadening of the probe molecules occurred as the sample plug headed toward the cathode during the initial time period, probably resulting in part from the stacking/sweeping, and destacking of the SC micelles at the boundaries between the sample zone and running buffer. Interestingly, a second sample zone narrowing event can be observed as the sample plug moved further toward the cathode, which could be attributed to the sweeping of the slower moving probe molecules by the faster moving SC micelles that originated from the anode. This phenomenon was studied as a function of pH, sample plug length, as well as the concentration of organic solvent and salt in the sample matrix. The data suggested that the presence of large amounts of an organic solvent (such as ACN or methanol) and salts in the sample matrix not only induces sample dispersion due to the formation of a pressure‐driven (hydrodynamic) flow, but may also lead to the formation of a double sample zone narrowing phenomenon by altering the local EOF dynamics within the separation system.
- 7 March 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (5-6) , 1104-1111
Fluorescence imaging of sample zone narrowing and dispersion in a glass microchip: The effects of organic solvent (acetonitrile)–salt mixtures in the sample matrix and surfactant micelles in the running buffer
A mismatch in the EOF velocities between the sample zone and running buffer region is known to generate pressure‐driven, parabolic flow profile of the sample plug in electrokinetic separation systems. In the present study, video fluorescence microscopy was employed to capture real‐time dynamics of the sample plug (containing fluorescein as the probe molecule) in a discontinuous conductivity system within a glass microchip, in which the sample matrix consisted of a mixture of ACN and salt (NaCl), and the running buffer contained sodium cholate (SC) micelles as the pseudo‐stationary phase (i.e., performing “ACN stacking” in the mode of MEKC). Upon application of the separation voltage, the video images revealed that zone narrowing and broadening of the probe molecules occurred as the sample plug headed toward the cathode during the initial time period, probably resulting in part from the stacking/sweeping, and destacking of the SC micelles at the boundaries between the sample zone and running buffer. Interestingly, a second sample zone narrowing event can be observed as the sample plug moved further toward the cathode, which could be attributed to the sweeping of the slower moving probe molecules by the faster moving SC micelles that originated from the anode. This phenomenon was studied as a function of pH, sample plug length, as well as the concentration of organic solvent and salt in the sample matrix. The data suggested that the presence of large amounts of an organic solvent (such as ACN or methanol) and salts in the sample matrix not only induces sample dispersion due to the formation of a pressure‐driven (hydrodynamic) flow, but may also lead to the formation of a double sample zone narrowing phenomenon by altering the local EOF dynamics within the separation system.
- 18 January 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (1) , 60-75
Recent applications of microemulsion electrokinetic chromatography
Compared to MEKC, the presence of a water‐immiscible oil phase in the microemulsion droplets of microemulsion EKC (MEEKC) gives rise to some special properties, such as enhanced solubilization capacity and enlarged migration window, which could allow for the improved separation of various hydrophobic and hydrophilic compounds, with reduced sample pretreatment steps, unique selectivities and/or higher efficiencies. Typically, stable and optically clear oil‐in‐water microemulsions containing a surfactant (SDS), oil (octane or heptane), and cosurfactant (1‐butanol) in phosphate buffer are employed as separation media in conventional MEEKC. However, in recent years, the applicability of reverse MEEKC (water‐in‐oil microemulsions) has also been demonstrated, such as for the enhanced separation of highly hydrophobic substances. Also, during the past few years, the development and application of MEEKC for the separation of chiral molecules has been expanded, based on the use of enantioselective microemulsions that contained a chiral surfactant or chiral alcohol. On the other hand, the application of MEEKC for the characterization of the lipophilicity of chemical substances remains an active and important area of research, such as the use of multiplex MEEKC for the high‐throughput determination of partition coefficients (log P values) of pharmaceutical compounds. In this review, recent applications of MEEKC (covering the period from 2003 to 2005) are reported. Emphases are placed on the discussion of MEEKC in the separation of chiral molecules and highly hydrophobic substances, as well as in the determination of partition coefficients, followed by a survey of recent applications of MEEKC in the analysis of pharmaceuticals, cosmetics and health‐care products, biological and environmental compounds, plant materials, and foods.
- 18 January 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (1) , 60-75
Recent applications of microemulsion electrokinetic chromatography
Compared to MEKC, the presence of a water‐immiscible oil phase in the microemulsion droplets of microemulsion EKC (MEEKC) gives rise to some special properties, such as enhanced solubilization capacity and enlarged migration window, which could allow for the improved separation of various hydrophobic and hydrophilic compounds, with reduced sample pretreatment steps, unique selectivities and/or higher efficiencies. Typically, stable and optically clear oil‐in‐water microemulsions containing a surfactant (SDS), oil (octane or heptane), and cosurfactant (1‐butanol) in phosphate buffer are employed as separation media in conventional MEEKC. However, in recent years, the applicability of reverse MEEKC (water‐in‐oil microemulsions) has also been demonstrated, such as for the enhanced separation of highly hydrophobic substances. Also, during the past few years, the development and application of MEEKC for the separation of chiral molecules has been expanded, based on the use of enantioselective microemulsions that contained a chiral surfactant or chiral alcohol. On the other hand, the application of MEEKC for the characterization of the lipophilicity of chemical substances remains an active and important area of research, such as the use of multiplex MEEKC for the high‐throughput determination of partition coefficients (log P values) of pharmaceutical compounds. In this review, recent applications of MEEKC (covering the period from 2003 to 2005) are reported. Emphases are placed on the discussion of MEEKC in the separation of chiral molecules and highly hydrophobic substances, as well as in the determination of partition coefficients, followed by a survey of recent applications of MEEKC in the analysis of pharmaceuticals, cosmetics and health‐care products, biological and environmental compounds, plant materials, and foods.
- 4 January 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1112 (1-2) , 361-368
Enantiomeric separation and quantification of ephedrine-type alkaloids in herbal materials by comprehensive two-dimensional gas chromatography
- 4 January 2006
- Published by Elsevier in Journal of Chromatography A
- Vol. 1112 (1-2) , 361-368
Enantiomeric separation and quantification of ephedrine-type alkaloids in herbal materials by comprehensive two-dimensional gas chromatography
- 5 September 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (17) , 3349-3359
Investigation of solvent effects in capillary electrophoresis for the separation of biological porphyrin methyl esters
The effects of organic solvents on the capillary electrophoresis (CE) separation of a number of important biological porphyrin methyl esters – six weakly basic, hydrophobic cyclic tetrapyrroles possessing two and four to eight methyl ester groups around the periphery of the porphyrin ring – were investigated in the mode of micellar electrokinetic chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC), and nonaqueous CE. In aqueous MEKC, partial separation of the six neutral porphyrin methyl esters was obtained with an organic modifier (acetonitrile) in the concentration range between 20 and 40%, in which sodium dodecyl sulfate (SDS) molecules might be present in the form of SDS micelles and/or SDS micelle‐like aggregates. Relatively stable SDS micelles can be formed in nonaqueous MEKC using formamide as the separation medium, but the separation of the target analytes remained unsatisfactory. Improved resolution of all six porphyrin methyl esters was obtained using MEEKC with the running buffer consisting of 0.8% w/w n‐heptane (oil phase), 2.25% w/w SDS and 1.0% w/w Brij 35 (mixed surfactant), 6.6% w/w 1‐butanol (cosurfactant), and 30% v/v 2‐propanol (second cosurfactant), but reproducibility in terms of peak areas for certain porphyrins (especially uroporphyrin I octamethyl ester) was found to be very poor. Best separation performances were achieved with nonaqueous CE separations in which the weakly basic porphyrin methyl esters were protonated under strongly acidic conditions (e.g., using 10 mM perchloric acid) in mixed organic solvents. For example, using a 50:50 mixture of methanol and acetonitrile as the separation medium, baseline separation of all six (positively charged) porphyrin methyl esters can be obtained within 3 min and the average precision (RSD, N = 13) in terms of migration time and peak area were 0.55 and 2.16%, respectively.
- 5 September 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (17) , 3349-3359
Investigation of solvent effects in capillary electrophoresis for the separation of biological porphyrin methyl esters
The effects of organic solvents on the capillary electrophoresis (CE) separation of a number of important biological porphyrin methyl esters – six weakly basic, hydrophobic cyclic tetrapyrroles possessing two and four to eight methyl ester groups around the periphery of the porphyrin ring – were investigated in the mode of micellar electrokinetic chromatography (MEKC), microemulsion electrokinetic chromatography (MEEKC), and nonaqueous CE. In aqueous MEKC, partial separation of the six neutral porphyrin methyl esters was obtained with an organic modifier (acetonitrile) in the concentration range between 20 and 40%, in which sodium dodecyl sulfate (SDS) molecules might be present in the form of SDS micelles and/or SDS micelle‐like aggregates. Relatively stable SDS micelles can be formed in nonaqueous MEKC using formamide as the separation medium, but the separation of the target analytes remained unsatisfactory. Improved resolution of all six porphyrin methyl esters was obtained using MEEKC with the running buffer consisting of 0.8% w/w n‐heptane (oil phase), 2.25% w/w SDS and 1.0% w/w Brij 35 (mixed surfactant), 6.6% w/w 1‐butanol (cosurfactant), and 30% v/v 2‐propanol (second cosurfactant), but reproducibility in terms of peak areas for certain porphyrins (especially uroporphyrin I octamethyl ester) was found to be very poor. Best separation performances were achieved with nonaqueous CE separations in which the weakly basic porphyrin methyl esters were protonated under strongly acidic conditions (e.g., using 10 mM perchloric acid) in mixed organic solvents. For example, using a 50:50 mixture of methanol and acetonitrile as the separation medium, baseline separation of all six (positively charged) porphyrin methyl esters can be obtained within 3 min and the average precision (RSD, N = 13) in terms of migration time and peak area were 0.55 and 2.16%, respectively.
- 15 February 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (4-5) , 885-894
Microemulsion and micellar electrokinetic chromatography of Hematoporphyrin D: A starting material of hematoporphyrin derivative
An investigation of the basic factors which govern the microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) separation of Hematoporphyrin D and its base hydrolysis product, hematoporphyrin derivative (HpD), was performed. These model compounds contain a complex mixture of porphyrin monomers, dimers and/or oligomers, and were utilized to gain insights into the MEEKC/micellar electrokinetic chromatography (MEKC) separation of samples containing highly lipophilic substances. For example, the organic modifier/cosurfactant (1‐butanol) and/or oil phase (e.g., 1‐octanol in comparison to ethyl acetate) were found to have an apparent influence on the separation selectivity of Hematoporphyrin D, the extent of which was dependent on the chemical nature of the surfactant employed (e.g., sodium dodecyl sulfate vs. sodium cholate). An interesting and important finding was that the presence of an organic modifier (methanol or acetonitrile at a concentration of 20% or higher) in the sample matrix as well as in the run buffer was essential for the optimal MEEKC or MEKC separation of a number of porphyrin monomers (including hematoporphyrin IX and its acetates, most likely hydroxyacetate, diacetate, and vinyl acetate, as well as its dehydration products, hydroxyethylvinyldeuteroporphyrin and protoporphyrin) contained in Hematoporphyrin D. On the other hand, the use of these optimized conditions for the MEEKC or MEKC separation of various oligomeric porphyrin species in HpD were unsatisfactory. As HpD is a well‐known and effective photosensitizing agent in photodynamic therapy (a new approach for cancer treatment), the improved separation and characterization of various monomeric and oligomeric porphyrin species in HpD and its starting material, such as Hematoporphyrin D, is a challenging and important task.
- 15 February 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (4-5) , 885-894
Microemulsion and micellar electrokinetic chromatography of Hematoporphyrin D: A starting material of hematoporphyrin derivative
An investigation of the basic factors which govern the microemulsion electrokinetic chromatography (MEEKC) and micellar electrokinetic chromatography (MEKC) separation of Hematoporphyrin D and its base hydrolysis product, hematoporphyrin derivative (HpD), was performed. These model compounds contain a complex mixture of porphyrin monomers, dimers and/or oligomers, and were utilized to gain insights into the MEEKC/micellar electrokinetic chromatography (MEKC) separation of samples containing highly lipophilic substances. For example, the organic modifier/cosurfactant (1‐butanol) and/or oil phase (e.g., 1‐octanol in comparison to ethyl acetate) were found to have an apparent influence on the separation selectivity of Hematoporphyrin D, the extent of which was dependent on the chemical nature of the surfactant employed (e.g., sodium dodecyl sulfate vs. sodium cholate). An interesting and important finding was that the presence of an organic modifier (methanol or acetonitrile at a concentration of 20% or higher) in the sample matrix as well as in the run buffer was essential for the optimal MEEKC or MEKC separation of a number of porphyrin monomers (including hematoporphyrin IX and its acetates, most likely hydroxyacetate, diacetate, and vinyl acetate, as well as its dehydration products, hydroxyethylvinyldeuteroporphyrin and protoporphyrin) contained in Hematoporphyrin D. On the other hand, the use of these optimized conditions for the MEEKC or MEKC separation of various oligomeric porphyrin species in HpD were unsatisfactory. As HpD is a well‐known and effective photosensitizing agent in photodynamic therapy (a new approach for cancer treatment), the improved separation and characterization of various monomeric and oligomeric porphyrin species in HpD and its starting material, such as Hematoporphyrin D, is a challenging and important task.
- 1 December 2004
- Published by Elsevier in Journal of Chromatography B
- Vol. 812 (1-2) , 241-257
Chromatographic and electrophoretic methods for Lingzhi pharmacologically active components
- 1 December 2004
- Published by Elsevier in Journal of Chromatography B
- Vol. 812 (1-2) , 241-257
Chromatographic and electrophoretic methods for Lingzhi pharmacologically active components
- 7 October 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (18-19) , 3263-3269
Separation of enantiomers in microemulsion electrokinetic chromatography using chiral alcohols as cosurfactants
A novel chiral microemulsion, which involved the use of chiral alcohols as cosurfactants, was demonstrated for the enantiomeric separation of a number of pharmaceutical drugs in microemulsion electrokinetic chromatography (MEEKC). The chiral alcohols investigated were optically active 2‐alkanols, with the alkyl chain length having carbon number ranging from 4 to 7. The data indicated that, except for R‐(—)‐2‐butanol, the use of R‐(—)‐2‐pentanol, R‐(—)‐2‐hexanol or R‐(—)‐2‐heptanol as the chiral cosurfactant resulted in the baseline or partial resolution of most of the test solutes, i.e., (±)‐norephedrine, (±)‐ephedrine, DL‐nadolol, and DL‐propranolol. In addition to the chain length of the chiral 2‐alkanols, the effects of other experimental conditions, such as the concentration and chirality of the 2‐alkanols, as well as the pH of the run buffer and the oil phase of the microemulsion, on the enantiomeric separation of the test solutes were also investigated. An interesting finding was that the water‐immiscible organic solvent (oil core) within the microemulsion droplets appeared to play an important role in the chiral separation mechanism. Also, the importance of hydrogen bonding between the test solutes ((±)‐ephedrine and related compounds) and the chiral microemulsion was demonstrated, as it was not possible to resolve a pair of enantiomers which lacked a β‐amino proton (i.e., (±)‐N‐methyl ephedrine) under optimized run buffer conditions (e.g., 5.0% R‐(—)‐2‐hexanol, 0.8% n‐octane, and 3.5% SDS in 90.7% borate buffer at pH 9.2).
- 7 October 2004
- Published by Wiley in Electrophoresis
- Vol. 25 (18-19) , 3263-3269
Separation of enantiomers in microemulsion electrokinetic chromatography using chiral alcohols as cosurfactants
A novel chiral microemulsion, which involved the use of chiral alcohols as cosurfactants, was demonstrated for the enantiomeric separation of a number of pharmaceutical drugs in microemulsion electrokinetic chromatography (MEEKC). The chiral alcohols investigated were optically active 2‐alkanols, with the alkyl chain length having carbon number ranging from 4 to 7. The data indicated that, except for R‐(—)‐2‐butanol, the use of R‐(—)‐2‐pentanol, R‐(—)‐2‐hexanol or R‐(—)‐2‐heptanol as the chiral cosurfactant resulted in the baseline or partial resolution of most of the test solutes, i.e., (±)‐norephedrine, (±)‐ephedrine, DL‐nadolol, and DL‐propranolol. In addition to the chain length of the chiral 2‐alkanols, the effects of other experimental conditions, such as the concentration and chirality of the 2‐alkanols, as well as the pH of the run buffer and the oil phase of the microemulsion, on the enantiomeric separation of the test solutes were also investigated. An interesting finding was that the water‐immiscible organic solvent (oil core) within the microemulsion droplets appeared to play an important role in the chiral separation mechanism. Also, the importance of hydrogen bonding between the test solutes ((±)‐ephedrine and related compounds) and the chiral microemulsion was demonstrated, as it was not possible to resolve a pair of enantiomers which lacked a β‐amino proton (i.e., (±)‐N‐methyl ephedrine) under optimized run buffer conditions (e.g., 5.0% R‐(—)‐2‐hexanol, 0.8% n‐octane, and 3.5% SDS in 90.7% borate buffer at pH 9.2).
- 2 April 2004
- Published by Wiley in Journal of Separation Science
- Vol. 27 (5-6) , 451-458
Application of headspace solid‐phase microextraction (HS‐SPME) and comprehensive two‐dimensional gas chromatography (GC×GC) for the chemical profiling of volatile oils in complex herbal mixtures
The coupling of headspace solid‐phase microextraction (HS‐SPME) with comprehensive two‐dimensional gas chromatography (GC×GC) was shown to be a powerful technique for the rapid sampling and analysis of volatile oils in complex herbal materials. When compared to one‐dimensional (1‐D) GC, the improved analytical capabilities of GC×GC in terms of increased detection sensitivity and separation power were demonstrated by using HS‐SPME/GC×GC for the chemical profiling (fingerprinting) of essential/volatile oils contained in herbal materials of increasing analytical complexity. More than 20 marker compounds belonging to Panax quinquefolius (American ginseng) can be observed within the 2‐D contour plots of ginseng itself, a mixture of ginseng and another important herb (P. quinquefolius/Radix angelicae sinensis), as well as a mixture of ginseng and three other herbs (P. quinquefolius /R. angelicae sinensis/R. astragali/R. rehmanniae preparata). Such analytical capabilities should be important towards the authentication and quality control of herbal products, which are receiving increasing attention as alternative medicines worldwide. In particular, the presence of Panax in the herb formulation could be readily identified through its specific peak pattern in the 2‐D GC×GC plot.
- 2 April 2004
- Published by Wiley in Journal of Separation Science
- Vol. 27 (5-6) , 451-458
Application of headspace solid‐phase microextraction (HS‐SPME) and comprehensive two‐dimensional gas chromatography (GC×GC) for the chemical profiling of volatile oils in complex herbal mixtures
The coupling of headspace solid‐phase microextraction (HS‐SPME) with comprehensive two‐dimensional gas chromatography (GC×GC) was shown to be a powerful technique for the rapid sampling and analysis of volatile oils in complex herbal materials. When compared to one‐dimensional (1‐D) GC, the improved analytical capabilities of GC×GC in terms of increased detection sensitivity and separation power were demonstrated by using HS‐SPME/GC×GC for the chemical profiling (fingerprinting) of essential/volatile oils contained in herbal materials of increasing analytical complexity. More than 20 marker compounds belonging to Panax quinquefolius (American ginseng) can be observed within the 2‐D contour plots of ginseng itself, a mixture of ginseng and another important herb (P. quinquefolius/Radix angelicae sinensis), as well as a mixture of ginseng and three other herbs (P. quinquefolius /R. angelicae sinensis/R. astragali/R. rehmanniae preparata). Such analytical capabilities should be important towards the authentication and quality control of herbal products, which are receiving increasing attention as alternative medicines worldwide. In particular, the presence of Panax in the herb formulation could be readily identified through its specific peak pattern in the 2‐D GC×GC plot.
- 18 December 2003
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 3,p. 288-289
Alteration of room temperature phosphorescence lifetimes of quinine and quinidine by chiral additives
Room temperature phosphorescence (RTP) lifetime differences between quinine and quinidine were observed in micellar solutions and the ability to alter these differences based on the use of chiral additives was demonstrated.
- 18 December 2003
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 3,p. 288-289
Alteration of room temperature phosphorescence lifetimes of quinine and quinidine by chiral additives
Room temperature phosphorescence (RTP) lifetime differences between quinine and quinidine were observed in micellar solutions and the ability to alter these differences based on the use of chiral additives was demonstrated.