MHMozammil Hussain

Mozammil Hussain

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mozammil Hussain has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Posterior Facet Load Changes in Adjacent Segments due to Moderate and Severe Degeneration in C5-C6 Disc

    by Mozammil Hussain, Raghu N. Natarajan, Gulafsha Chaudhary, Howard S. An, Gunnar B.J. Andersson

    Biomechanics of normal vertebral segments adjacent to a degenerated segment in the cervical spine. To test the hypothesis that posterior facet joints of adjacent segments are loaded more when degeneration occurs in the intermediate disc segment. Degeneration progression in adjacent segments is a clinical concern. Literature studies that have documented the effects of a degenerated segment on the adjacent-segment discs have not addressed these effects on adjacent-segment posterior facets. Moreover, these biomechanical studies are performed mainly on the lumbar spine or the tissue quality of the cadavers is poor because of degenerated segments. Retrospectively, it is difficult to decipher to what extent degeneration in a single disc induces biomechanical changes in facet joints along the posterior spinal column. To date, no cervical spine biomechanical study investigated the facet joints response of adjacent segments when the disc in between those segments degenerates. An earlier validated poroelastic, 3-dimensional finite element model of a normal C3-T1 segment was used. Two stages of degeneration (moderate and severe) were simulated in the C5-C6 disc. Disc geometry and tissue material properties were modified to simulate C5-C6 disc degeneration. For the 3 C3-T1 models, loads on the posterior facets at 3 levels (C4-C5, C5-C6, and C6-C7) were computed under moment loads. With progressive degeneration in the C5-C6 disc, posterior facet loading in adjacent segments and in the intermediate degenerated disc segment increased. Changes in facet loading in the inferior C6-C7 segment were greater than the corresponding changes in the superior C4-C5 segment. These changes were highest in lateral bending and lowest in axial rotation. Higher changes in facet loads along the posterior spinal column may contribute to altered biomechanics in neighboring segments. Future biomechanical experiments are required to develop a more clear understanding of the posterior facet joints response in neighboring segments because of degeneration in a cervical disc.


  • Corpectomy versus discectomy for the treatment of multilevel cervical spine pathology: a finite element model analysis

    by Mozammil Hussain, Ahmad Nassr, Raghu N. Natarajan, Howard S. An, Gunnar B.J. Andersson


  • Progressive disc degeneration at C5–C6 segment affects the mechanics between disc heights and posterior facets above and below the degenerated segment: A flexion–extension investigation using a poroelastic C3–T1 finite element model

    by Mozammil Hussain, Raghu N. Natarajan, Howard S. An, Gunnar B.J. Andersson

    Disc degeneration (DD) is often accompanied by a height reduction of the anterior and posterior discs (AD and PD, respectively), and this affect the way in which articulating posterior facets (PFs) come into contact during physiological motions. Any increase in the contact between overlapping articulating facet surfaces increases PF loading. Development of adjacent segment disease is a significant clinical concern. It still is not clear how degenerative motion changes in AD and PD heights affect the mechanics of adjacent segment discs and facets. We hypothesized that changes in axial height patterns (in the AD and PD) at the degenerated C5-C6 disc-segment would affect axial height patterns (in the AD and PD) above and below the degenerated disc-segment. A previously validated poroelastic three-dimensional finite element (FE) model of a normal C3-T1 segment was used. Two additional C3-T1 models were built with moderate and severe DD at C5-C6. The three FE models were evaluated in flexion and extension. With progressive C5-C6 DD, AD and PD flexibility (axial deformation or elongation per unit load) at C5-C6 decrease with a compensatory corresponding flexibility increase in adjacent segments (normal), whereas PF loading increased at all segments only during extension. Changes in AD and PD flexibility and PF loading were higher at inferior segments than at superior segments. This study confirmed the hypothesis that the anterior and posterior discs and articulating facets of cervical spine segments are affected during flexion and extension motions when a disc-segment degenerates. Motion changes involving a higher PD height loss, both at the degenerated and adjacent segments, would further increase PF loading along the posterior spinal column - a possible mechanism for the dysfunctioning of the facet joints. The current data should be compared to other multi-segmental cervical spine experiments.


  • Simulation of Inhomogeneous Rather Than Homogeneous Poroelastic Tissue Material Properties Within Disc Annulus and Nucleus Better Predicts Cervical Spine Response

    by Mozammil Hussain, Raghu N. Natarajan, Gulafsha Chaudhary, Howard S. An, Gunnar B. Andersson

    A finite element (FE) modeling of homogeneous and inhomogeneous poroelastic tissue material properties within disc anulus fibrosus (AF) and nucleus pulposus (NP). To test the hypothesis that simulation of inhomogeneous poroelastic tissue material properties within AF and NP quadrants, rather than homogeneous properties within regions of AF and NP without quadrants, would better predict the cervical spine biomechanics. In order to represent tissue swelling and creep deformation behavior more physiologically in FE models, disc poroelastic tissue material properties should be modeled appropriately. Past studies show an existence of inhomogeneous rather than homogeneous nature of the tissue properties in various quadrants of AF and NP, and this has been simulated in a single-segment FE lumbar model with only compression analysis. This article simulated these tissue properties in a multisegmental cervical spine and reported the results of both compression and moment loads. Two three-dimensional FE models of a C3-T1 segment were developed. Model I included homogeneous poroelastic tissue properties in AF and NP, whereas Model II included inhomogeneous poroelastic tissue properties in AF and NP quadrants. Biomechanical responses of the FE models under diurnal compression and moment loads were compared with corresponding in vivo published studies. Model II with disc quadrant-based inhomogeneous poroelastic tissue properties predicted better, mainly in flexion and extension, than the Model I with homogeneous tissue properties when compared with the corresponding in vivo results, thereby confirming the current study hypothesis. Inhomogeneous tissue properties govern segmental behavior mainly during sagittal plane motions, with a root-mean-square difference of nearly 50% across the motion segments. The current data justify the need to simulate inhomogeneous tissue properties within disc quadrants for any FE model analysis. Model II can be further used to understand the biomechanical effects of quadrant-based degenerative poroelastic tissue properties on cervical spine behavior. Future experiments are necessary to support the current study results.


  • Relative contributions of strain-dependent permeability and fixed charged density of proteoglycans in predicting cervical disc biomechanics: A poroelastic C5–C6 finite element model study

    by Mozammil Hussain, Raghu N. Natarajan, Gulafsha Chaudhary, Howard S. An, Gunnar B.J. Andersson

    Disc swelling pressure (P(swell)) facilitated by fixed charged density (FCD) of proteoglycans (P(fcd)) and strain-dependent permeability (P(strain)) are of critical significance in the physiological functioning of discs. FCD of proteoglycans prevents any excessive matrix deformation by tissue stiffening, whereas strain-dependent permeability limits the rate of stress transfer from fluid to solid skeleton. To date, studies involving the modeling of FCD of proteoglycans and strain-dependent permeability have not been reported for the cervical discs. The current study objective is to compare the relative contributions of strain-dependent permeability and FCD of proteoglycans in predicting cervical disc biomechanics. Three-dimensional finite element models of a C5-C6 segment with three different disc compositions were analyzed: an SPFP model (strain-dependent permeability and FCD of proteoglycans), an SP model (strain-dependent permeability alone), and an FP model (FCD of proteoglycans alone). The outcomes of the current study suggest that the relative contributions of strain-dependent permeability and FCD of proteoglycans were almost comparable in predicting the physiological behavior of the cervical discs under moment loads. However, under compression, strain-dependent permeability better predicted the in vivo disc response than that of the FCD of proteoglycans. Unlike the FP model (least stiff) in compression, motion behavior of the three models did not vary much from each other and agreed well within the standard deviations of the corresponding in vivo published data. Flexion was recorded with maximum P(fcd) and P(strain), whereas minimum values were found in extension. The study data enhance the understanding of the roles played by the FCD of proteoglycans and strain-dependent permeability and porosity in determining disc tissue swelling behavior. Degenerative changes involving strain-dependent permeability and/or loss of FCD of proteoglycans can further be studied using an SPFP model. Future experiments are necessary to support the current study results.


  • Patterns of Height Changes in Anterior and Posterior Cervical Disc Regions Affects the Contact Loading at Posterior Facets During Moderate and Severe Disc Degeneration

    by Mozammil Hussain, Raghu N. Natarajan, Howard S. An, Gunnar B. J. Andersson

    Study Design. Biomechanical roles of anterior and posterior portions of the disc (AD and PD, respectively) in governing posterior facets (PF) behavior of a C5-C6 motion segment. Objective. To understand how height patterns (loss and gain) at AD and PD affects the PF contact loading during moderate and severe grades of cervical disc degeneration (DD). Summary of Background Data. PF overloading and degeneration after degenerative disc height loss is a clinical concern. This may occur because of a decrease in facet joints space, causing elevated PF contact forces. During a physiologic motion, axial disc height patterns at AD and PD affects the spacing and overlapping of articulating PF surfaces. The question arises as to what percentage of deformation and/or elongation at AD and PD is contributing to a corresponding increase and/or decrease in PF contact loading. Methods. A poroelastic, three-dimensional finite element model of a C5-C6 segment with a normal (grade I) disc was used after validation. Two degenerated disc models were developed from the normal disc model: moderate (combined effect of Thompson disc grades II and III) and severe (combined effect of Thompson disc grades IV and V). The models were analyzed under compression, flexion, and extension. Height patterns (loss and gain) at AD and PD, and PF loading were calculated for each model. Results. PF loading increased with PD height loss, and further increased with AD height gain. In moderate DD, PF loading was more affected by PD height loss than AD height gain, whereas in severe DD, it was more affected by AD height gain than PD height loss. Conclusion. The current study conclusions suggest a possible mechanism for PF loading through loss and gain in the AD and PD heights during moderate and severe grades of DD. Further cervical spine based biomechanical investigations are suggested to verify our findings.


  • Reduction in Disk and Fiber Stresses by Axial Distraction is Higher in Cervical Disk With Fibers Oriented Toward the Vertical Rather Than Horizontal Plane: A Finite Element Model Analysis

    by Mozammil Hussain, Ralph E. Gay, Kai-Nan An

    The purpose of this study was to quantify the biomechanical changes that occur in a compressed cervical disk with the application of axial distraction when the annular fiber orientation angles are varied between the horizontal and vertical planes. A 3-dimensional finite element (FE) model of a cervical motion segment was developed. From this model, 3 FE models were developed and validated corresponding to 3 different fiber angles relative to the end plate-disk interface: +/-25 degrees (oriented toward the horizontal plane), +/-45 degrees (midway between the horizontal and vertical planes), and +/-65 degrees (oriented toward the vertical plane). Compression (50N), followed by an axial distraction (17N), was simulated. Annulus and nucleus stresses, von-Mises fiber stresses, annulus radial bulging, and nucleus radial displacement were computed. Hard tissue (cortical and cancellous bones and end plate) stresses were also quantified. With increasing fiber angle (toward vertical), axial segmental stiffness increased, whereas annulus and nucleus stresses, fiber stresses, annulus radial bulging, and nucleus radial displacement decreased. Similar outcomes were observed when axial distraction was applied to the compressed segment. Hard tissues were not affected with varying fiber angles; however, their mechanics changed when axial distraction was applied on the compressed segment. We noted lower disk stress in axial distraction than in compression. The results confirmed the hypothesis that fibers oriented toward the vertical plane reduce disk and fiber stresses and disk bulging. By aligning annular fibers toward the vertical plane axial distraction may help reduce disk and fiber stresses. Axial disk stresses decrease radially from outside to inside under compressive loading and that the anterior annulus is more stressed than the posterior-lateral annulus during both compression and distraction. Stresses decreased in both the annulus tissue matrix and fibers with increasing fiber angles and increasing fiber slope to 90 degrees (vertical fibers) is further anticipated to reduce the compressive disk stresses. The fibers in tension apply compression to the annulus tissue matrix, thus, decreasing annulus stresses in the axial and circumferential directions.


  • Motion Changes in Adjacent Segments due to Moderate and Severe Degeneration in C5–C6 Disc

    by Mozammil Hussain, Raghu N. Natarajan, Howard S. An, Gunnar B.J. Andersson

    Study Design. Biomechanics of normal vertebral segments adjacent to a degenerated segment in the cervical spine. Objective. To test the hypothesis of higher motion changes in the segment immediately inferior to a degenerated segment. Summary of Background Data. Past research has shown how disc degeneration (DD) affects adjacent segments; however, these studies are conducted only on the lumbar spine or the experimental protocols used are characterized by the presence of degeneration in adjacent segments. The question arises as to how much of the degenerative effect in a particular segment is internal to degeneration at that segment and how much is caused by degeneration at adjacent segments. It would be clinically relevant to analyze biomechanical changes in adjacent segments in the cervical spine by considering DD at only one segment, where adjacent segments remain normal. Methods. A poroelastic, 3-dimensional finite element model of a normal C3–T1 segment was validated and then used for the degenerative study. Two additional C3–T1 models were developed with moderate and severe degenerative C5–C6 disc grades. Disc geometry and tissue material properties were modified to simulate C5–C6 DD. Intersegmental rotational motions (C4–C5, C5–C6, and C6–C7) for the 3 C3–T1 models were computed under moment loads. Results. With progressive C5–C6 DD, motion decreased at that segment. At adjacent segments, higher motion changes were observed mainly in flexion/extension. Inferior C6–C7 motion changes were higher than superior C4–C5 motion changes. The inferior C6–C7 motion was affected even when C5–C6 DD was moderate, and it was further affected by severe C5–C6 DD. The superior C4–C7 motion, however, was mostly affected by severe C5–C6 DD. Conclusion. The hypothesis of higher motion changes in the normal C6–C7 segment immediately inferior to a degenerated C5–C6 segment was found to be true. Future experiments on multisegmental cervical spines are recommended to verify the current data.