Christoph Kniestedt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Christoph Kniestedt has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Michelle Nee
3 shared publicationsJörg Stürmer
2 shared publicationsRobert L. Stamper
Department of Ophthalmology, University of California San Francisco, San Francisco, California, USA
2 shared publicationsAlan Bostrom
1 shared publicationHartmut Kanngiesser
1 shared publicationJoyce Choe
1 shared publication
Latest Publications
- 1 November 2006
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 124 (11) , 1664
Applanation Area in Goldmann Applanation Tonometry—Reply
In reply We thank Dr Tesser for his observations. He is correct that the precise diameter of 3.06 mm allows the easy conversion of 1 g of force (1 pond) to 10 mm Hg. However, we do disagree that a range of diameters would allow a balance between the effect of corneal elasticity and the effect of the capillary attraction of tears. In their paper,1Goldmann and Schmidt show Figure 8 (page 232) which clearly demonstrates a linear relationship between applanation diameter and corneal rigidity forces for diameters greater than 3mm with a slope different than 0. The graph also shows that the behaviour is different for each eye. Therefore, the corneal rigidity and capillary attraction forces balance each other only where this line for an individual eye crosses 0 at exactly 3.06 mm applanation diameter.
- 1 November 2006
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 124 (11) , 1664
Applanation Area in Goldmann Applanation Tonometry—Reply
In reply We thank Dr Tesser for his observations. He is correct that the precise diameter of 3.06 mm allows the easy conversion of 1 g of force (1 pond) to 10 mm Hg. However, we do disagree that a range of diameters would allow a balance between the effect of corneal elasticity and the effect of the capillary attraction of tears. In their paper,1Goldmann and Schmidt show Figure 8 (page 232) which clearly demonstrates a linear relationship between applanation diameter and corneal rigidity forces for diameters greater than 3mm with a slope different than 0. The graph also shows that the behaviour is different for each eye. Therefore, the corneal rigidity and capillary attraction forces balance each other only where this line for an individual eye crosses 0 at exactly 3.06 mm applanation diameter.
- 1 April 2006
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 15 (2) , 91-97
Correlation Between Intraocular Pressure, Central Corneal Thickness, Stage of Glaucoma, and Demographic Patient Data
To determine the correlation of central corneal thickness (CCT) to Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT, PASCAL®), and to glaucoma stage as assessed by cup-to-disc ratio (CDR). Prospective, cross-sectional tricenter observation study. From three glaucoma specialty practices a sample of 406 independent eyes was included. After ultrasound pachymetry, intraocular pressure was measured using PASCAL® and Goldmann applanation tonometry and cup-to-disc ration was reassessed. Demographic data were included in the multivariate analysis. Mean corneal thickness was 540 μm. African Americans and normal-tension glaucoma patients showed the lowest values (518 μm and 522 μm, respectively). These values were significantly thinner than the central corneal thickness of Caucasians (549 μm) and ocular hypertensives (564 μm). Intraocular pressure assessed by Goldmann applanation tonometry shows a significant correlation with central corneal thickness (r2=0.068, P<0.001), whereas PASCAL® is not significantly associated with central corneal thickness (r2<0.001, P=0.997). Increased IOP is significantly correlated with large ocular pulse amplitudes (r2=0.13, P<0.001), which is predominantly seen in ocular hypertensives. A significant negative correlation was detected between cup-to-disc ratio and central corneal thickness (r2=0.102, P<0.001). Glaucoma patients with thin central corneal thickness are more likely to be found at an advanced stage of the disease and among those with normal-tension glaucoma and black African ancestry. Underestimation of intraocular pressure by Goldmann applanation tonometry could be one causative factor.
- 1 April 2006
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 15 (2) , 91-97
Correlation Between Intraocular Pressure, Central Corneal Thickness, Stage of Glaucoma, and Demographic Patient Data
To determine the correlation of central corneal thickness (CCT) to Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT, PASCAL®), and to glaucoma stage as assessed by cup-to-disc ratio (CDR). Prospective, cross-sectional tricenter observation study. From three glaucoma specialty practices a sample of 406 independent eyes was included. After ultrasound pachymetry, intraocular pressure was measured using PASCAL® and Goldmann applanation tonometry and cup-to-disc ration was reassessed. Demographic data were included in the multivariate analysis. Mean corneal thickness was 540 μm. African Americans and normal-tension glaucoma patients showed the lowest values (518 μm and 522 μm, respectively). These values were significantly thinner than the central corneal thickness of Caucasians (549 μm) and ocular hypertensives (564 μm). Intraocular pressure assessed by Goldmann applanation tonometry shows a significant correlation with central corneal thickness (r2=0.068, P<0.001), whereas PASCAL® is not significantly associated with central corneal thickness (r2<0.001, P=0.997). Increased IOP is significantly correlated with large ocular pulse amplitudes (r2=0.13, P<0.001), which is predominantly seen in ocular hypertensives. A significant negative correlation was detected between cup-to-disc ratio and central corneal thickness (r2=0.102, P<0.001). Glaucoma patients with thin central corneal thickness are more likely to be found at an advanced stage of the disease and among those with normal-tension glaucoma and black African ancestry. Underestimation of intraocular pressure by Goldmann applanation tonometry could be one causative factor.
- 16 February 2005
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 83 (1) , 129-130
Clinical alert: damage to Goldmann applanation tonometer tips
- 16 February 2005
- Published by Wiley in Acta Ophthalmologica Scandinavica
- Vol. 83 (1) , 129-130
Clinical alert: damage to Goldmann applanation tonometer tips
- 13 October 2004
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 243 (4) , 359-366
Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states
In an experimental laboratory investigation we compared intraocular pressure (IOP) measurements obtained by dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT), and pneumatonometry (PTG) with intracameral manometry on human cadaver corneas of different hydration conditions. Ten freshly enucleated eyes were de-epithelialized. Two tubes were placed in the anterior chamber in opposite directions and connected to a transducer and to a bottle system filled with balanced salt solution. The pressure in the eye was then adjusted between 5 mmHg and 58 mmHg by electronically altering the height of the bottle. Central corneal thickness (CCT) was registered and IOP measurements were obtained with DCT, GAT, and PTG at each manometric pressure reading. Immediately after the trial the same corneas were artificially dehydrated and the same measurement regimen was repeated. In the pressure range defined by the bottle height 10–50 cm, IOP values measured by DCT were 0.50 mmHg (95% CI=0.40–0.60) and 0.36 mmHg (95% CI=0.25–0.47) higher than manometric readings before and after dehydration, respectively. GAT showed consistently lower values than manometry, the difference being −3.48 mmHg (95% CI=−3.91 to −3.05) and −3.14 mmHg (95% CI=−3.39 to −2.89), respectively. Similar results were obtained with PGT, namely differences of −4.75 mmHg (95% CI=−5.21 to −4.29) and −3.98 mmHg (95% CI=−4.48 to −3.48) for the hydrated and the dehydrated corneal condition, respectively. Only DCT showed no significant change in accuracy between hydrated and dehydrated corneas. In this in vitro study DCT values for IOP were significantly closer to the manometric reference pressure than those obtained using GAT and PTG, independent of the state of corneal hydration.
- 13 October 2004
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 243 (4) , 359-366
Accuracy of dynamic contour tonometry compared with applanation tonometry in human cadaver eyes of different hydration states
In an experimental laboratory investigation we compared intraocular pressure (IOP) measurements obtained by dynamic contour tonometry (DCT), Goldmann applanation tonometry (GAT), and pneumatonometry (PTG) with intracameral manometry on human cadaver corneas of different hydration conditions. Ten freshly enucleated eyes were de-epithelialized. Two tubes were placed in the anterior chamber in opposite directions and connected to a transducer and to a bottle system filled with balanced salt solution. The pressure in the eye was then adjusted between 5 mmHg and 58 mmHg by electronically altering the height of the bottle. Central corneal thickness (CCT) was registered and IOP measurements were obtained with DCT, GAT, and PTG at each manometric pressure reading. Immediately after the trial the same corneas were artificially dehydrated and the same measurement regimen was repeated. In the pressure range defined by the bottle height 10–50 cm, IOP values measured by DCT were 0.50 mmHg (95% CI=0.40–0.60) and 0.36 mmHg (95% CI=0.25–0.47) higher than manometric readings before and after dehydration, respectively. GAT showed consistently lower values than manometry, the difference being −3.48 mmHg (95% CI=−3.91 to −3.05) and −3.14 mmHg (95% CI=−3.39 to −2.89), respectively. Similar results were obtained with PGT, namely differences of −4.75 mmHg (95% CI=−5.21 to −4.29) and −3.98 mmHg (95% CI=−4.48 to −3.48) for the hydrated and the dehydrated corneal condition, respectively. Only DCT showed no significant change in accuracy between hydrated and dehydrated corneas. In this in vitro study DCT values for IOP were significantly closer to the manometric reference pressure than those obtained using GAT and PTG, independent of the state of corneal hydration.