AVAnja Viestenz

Anja Viestenz

*This is an algorithmically generated author record based on publicly available information.

Anja Viestenz has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Toric Intraocular Lenses—Theory, Matrix Calculations, and Clinical Practice

    by Achim Langenbucher, Anja Viestenz, Nóra Szentmáry, Wolfgang Behrens-Baumann, Arne Viestenz

    Journal of Refractive Surgery | PURPOSETo describe 1) how to determine toric (posterior chamber) intraocular lenses (IOLs) with standard formulas, 2) a matrix-based calculation scheme for determining toric IOLs using 4x4 matrices, 3) a method to determine residual refraction after implantation of an arbitrary toric lens, and 4) to address clinical aspects. METHODSFormulas and metrics are reviewed for determining IOL power and


  • Raytracing von Hornhauttopographiedaten zur Ermittlung der optischen Abbildungsqualität des Auges

    by Achim Langenbucher, Tomas Sauer, Gerhard J. van der Heyd, Anja Viestenz, Berthold Seitz

    Hintergrund: Optische Aberrationen im Übertragungskanal beeinträchtigen die Abbildungsqualität des Auges in einer Weise, wie sie durch sphärozylindrische Gläser nicht vollständig ausgeglichen werden können. Die zu erwartende korrigierte Sehschärfe ist somit reduziert. Ziel dieser Studie war, die optische Abbildung einer punktförmigen Lichtquelle sowie eines ausgedehnten Objektes unter Verwendung computertopographischer Messdaten mit exaktem Raytracing abzuleiten. Methoden: Aus den Rohhöhendaten des Hornhauttopographiesystems (TMS-1, Tomey, Erlangen bzw. Orbscan, Orbtec Inc, USA) wurde mittels interpolierendem Subdivisionsschema (modifiziertes Butterfly-Schema) eine konvexe einfach differenzierbare (C1) refraktive Grenzfläche (Hornhautvorderfläche bzw. Vorder- und Rückfläche) berechnet. Die Charakteristika der verbleibenden Grenzflächen wurden dem Augenmodell nach Navarro entnommen. Aus der Berechnung der Punktstreuung (sog. „point-spread function”) mittels exaktem Raytracing (Anwendung des Snellius-Gesetzes) wurde die Fokusebene individuell durch eine Minimierung der Varianz ermittelt. Die Beugung an der Apertur wurde in Form einer Transmissionscharakteristik (radialsymmetrische Bessel-Funktion) an der Eintrittspupille des Systems realisiert. Das Schema wurde in der Programmiersprache C unter LINUX entwickelt und auf einen Normalbefund (Beispiel 1, TMS-1), einen Befund bei Keratokonus im fortgeschrittenem Stadium (Beispiel 2, TMS-1) und einen Befund mit Hornhautnarben (Beispiel 3, Orbscan) angewandt. Ergebnisse: Im Beispiel 1 vergrößerte sich der Fokusabstand (22,5 mm, 22,6 mm und 22,8 mm) geringfügig mit der Pupillenweite (2 mm, 3 mm und 5 mm). Die Varianz der nahezu radialsymmetrischen „point-spread function” in der Fokusebene erreichte einen minimalen Wert bei einer Pupillenweite von 3 mm (0,164, 0,104 und 0,230). Im Beispiel 2 veränderte sich aufgrund der optischen Aberrationen (v. a. Verkippung, Koma und Trifoil) der Fokusabstand uneinheitlich (21,1 mm, 21,0 mm und 21,3 mm) mit der Pupillenweite (2 mm; 3 mm und 5 mm). Die Varianz der deutlich asymmetrischen „point-spread function” in der Fokusebene lag durchwegs über den Vergleichswerten bei Beispiel 1 und erreichte einen minimalen Wert bei einer Pupillenweite von 3 mm (0,255, 0,224 und 0,371). Das optische Auflösungsvermögen (sinusförmig moduliertes Streifenmuster) war aufgrund der Unsymmetrie der „point-spread function” abhängig von der Orientierung (anisotrop). Im Beispiel 3 veränderte sich der Fokusabstand (22,3 mm, 22,3 mm und 22,5 mm) unwesentlich mit der Pupillenweite (2 mm, 3 mm und 5 mm). Die Varianz der „point-spread function” in der Fokusebene lag unter den Vergleichswerten aus Beispiel 2 und änderte sich unwesentlich zwischen Pupillenweiten von 2 und 3 mm (0,231, 0,239 und 0,338). Schlussfolgerung: Raytracing von topographischen Höhendaten auf der Basis eines Augenmodells mit der Option einer Autofokusfunktion bietet die Möglichkeit, das optische Auflösungsvermögen des Auges für punktförmige oder endlich ausgedehnte Lichtquellen abzuleiten. Weitere Studien über das Kontrastempfindlichkeitsverhalten und die Übertragung des optischen Bildes ins Gehirn sind nötig für eine vollständige Modellierung der subjektiven Sehschärfe. Background: Optical aberrations in the optical system may downgrade image quality and cannot be fully compensated by spherocylindrical glasses. The subjectively evaluated visual acuity may be significantly reduced. The purpose of this study was to calculate the image forming properties of the eye using a spotlight source or alternatively extended objects. Methods: A convex and first derivative continuous (C1) surface from the rough height data of the anterior corneal surface (TMS-1, Tomey, Erlangen) or the anterior and posterior corneal surface (Orbscan, Orbtec, USA) was calculated by means of an interpolating subdivision scheme (modified Butterfly algorithm). The characteristics of the residual refractive surfaces were used according to Navarro's eye model. The focal distance was calculated from the exact raytracing calculation (Snellius' law) of the point-spread function by minimising the variance of the point-spread function. The diffraction property of the aperture stop was implemented with a transmission characteristic according to a radially symmetrical Bessel function within the entrance pupil. The algorithm was realised with a C code on the LINUX platform and applied to a normal eye (example 1, TMS-1), an eye with severe keratoconus (example 2, TMS-1) and an eye with corneal scars (example 3, Orbscan). Results: The focal distance in example 1 (22.5 mm, 22.6 mm, and 22.8 mm) increased with the pupil diameter (2 mm, 3 mm, and 5 mm). The variance of the approximately radially symmetrical point-spread function in the focal plane attained a minimum value with a pupil size of 3 mm (0.164, 0.104, and 0.230). In example 2, the focal distance changed inconclusively (21.1 mm, 21.0 mm, and 21.3 mm) with the pupil size (2 mm, 3 mm, and 5 mm). The variance of the markedly asymmetrical point-spread function in the focal plane was systematically higher compared to the values of example 1 and reached a minimum value with a pupil size of 3 mm (0.255, 0.224, and 0.371). The imaging of the sinus-modulated pattern is anisotropic due to the asymmetry of the point-spread function. In example 3, the focal distance (22.3 mm, 22.3 mm, and 22.5 mm) did not change systematically with the pupil size (2 mm, 3 mm, and 5 mm). The variance of the nearly radially symmetrical point-spread function changed only marginally...


  • Wavelets zur Repräsentation von Hornhauttopographiedaten nach nichtmechanischer perforierender Keratoplastik - eine klinische Studie

    by Achim Langenbucher, Anja Viestenz, Berthold Seitz

    Hintergrund Oberflächenirregularitäten der Hornhaut sind oftmals maßgebliche Ursachen dafür, dass nach einer perforierenden Keratoplastik (PK) keine volle visuelle Rehabilitation erreicht wird. Topographiesysteme liefern in der Regel empirisch abgeleitete und systemspezifische Kenngrößen für diese Inhomogenitäten und erschweren einen Vergleich verschiedener Analysesysteme. Ziel der Studie war die auflösungsadaptierte Detektion und Quantifizierung fokaler Oberflächenirregularitäten der Hornhaut nach nichtmechanischer perforierender Keratoplastik mittels 2-dimensionaler Wavelet-Zerlegung auf der Basis von Hornhauttopographiedaten. Patienten und Methoden 15 Patienten mit Keratokonus und 10 mit Fuchs-Dystrophie nach perforierender Keratoplastik und vollständiger Entfernung der Nähte wurden in die Studie einbezogen. Für die Trepanation wurde der Excimer-Laser MEL60 der Fa. Aesculap-Meditec (Jena) verwendet (7,5/7,6 mm bei primären Dystrophien, 8,0/8,1 mm bei Keratokonus, doppelt fortlaufende 10-0-Nylon-Naht nach Hoffmann). Nach Fadenentfernung wurde neben einer vollständigen ophthalmologischen Untersuchung eine Hornhauttopographieanalyse (OrbScan, Orbtec, USA) durchgeführt. Die Brechkraftdaten wurden exportiert und mittels 2-dimensionaler Wavelet-Zerlegung (Daubechies-4-Wavelets) die Detailkoeffizienten bis zur Auflösungsstufe 5 ermittelt und ausgewertet. Somit ließen sich die Ausdehnung und Ausprägung fokaler Irregularitäten (Stufe 1=feine Details bis Stufe 5=grobe Details) erfassen. Ergebnisse Mit Ausnahme der Diagonalkoeffizienten bei der Fuchs-Dystrophie liegen die Wavelet-Koeffizienten der 1. Stufe über den Werten der höheren Auflösungsstufen, was einen hohen Anteil feiner und wenig ausgedehnter Irregularitäten belegt. In der 3. und 4. Auflösungsstufe wurde ein relatives Maximum aller Detailkoeffizienten beobachtet, während diese Koeffizienten in der 2. und 5. Auflösungsstufe signifikant niedriger lagen (p < 0,04). Die horizontalen (1,44 ± 0,22), vertikalen (1,42 ± 0,26) und diagonalen (0,69 ± 0,10) Detailkoeffizienten der ersten Auflösungsstufe korrelierten signifikant mit dem vom Topographiesystem angegebenen „Irregulären Astigmatismus” (1,40 ± 0,31 D)(p < 0,05). Die horizontalen und vertikalen Detailkoeffizienten der 3. und 4. Stufe korrelierten statistisch signifikant invers mit der Sehschärfe (p < 0,04). In der Gruppe mit Keratokonus lagen die Irregularitäten unter den Vergleichswerten bei Fuchs-Dystrophie. Schlussfolgerung Die Wavelet-Zerlegung von topographischen Brechkraftdaten ermöglicht die definierte Abtrennung und Quantifizierung von fokalen Irregularitäten unabhängig vom verwendeten Topographiesystem und bietet darüber hinaus die Möglichkeit der (auflösungsadaptierten) Glättung und Datenkompression. Background Corneal surface irregularities may limit the visual outcome after penetrating keratoplasty (PK). Corneal topographers mainly render empirically derived and system-specific statistical indices for characterization of superficial inhomogeneities which may lack clinical evidence and make inter-system comparisons difficult. The purpose of this study was to detect and quantify focal surface irregularities of the cornea after nonmechanical PK by 2-dimensional wavelet decomposition based on corneal topography data. Patients and methods Our study included 15 patients with keratoconus and 10 patients with Fuchs' dystrophy with all-sutures-out after penetrating keratoplasty. For trephination we used the excimer laser MEL60 (Aesculap-Meditec, Germany) (7.5/7.6 mm diameter in dystrophies, 8.0/8.1 mm in keratoconus, double-running 10-0 nylon suture). After suture removal a complete ophthalmological examination including OrbScan topography analysis (Orbtec, USA) was performed. The refraction data were extracted via „data recorder” and decomposed using 2-dimensional wavelet analysis methods (Daubechies-4-wavelets on five scales of resolution). Corneal irregularities were quantified (scale 1=fine details to scale 5=coarse details). Results All detail coefficients (horizontal, vertical and diagonal) correlated statistically significant with the „Irregular Astigmatism” provided by the OrbScan-system (p < 0.05). In scale 3 and 4 a relative maximum of the wavelet detail coefficients occurred, whereas the coefficients at scale 2 and 5 were significantly smaller. The horizontal and vertical detail coefficients correlated significantly inversely with the best-corrected visual acuity (p < 0.04). All detail coefficients were significantly lower in the patient group with keratoconus compared to Fuchs' dystrophy. Conclusions Wavelet decomposition of corneal topography refraction data allows an analytical isolation and quantification of focal corneal superficial irregularities. This algorithm is independent of the currently used topography system and allows a smoothing of the raw data set adapted to scale of resolution and data compression. 01 1 Manuskript erstmalig eingereicht am 8. 8. 00 und in der vorliegenden Form angenommen am 25. 9. 00. 02 2 Herrn Prof. Naumann zum 65. Geburtstag gewidmet. 03 3 Die Autoren haben kein finanzielles Interesse an der vorgelegten Studie.