Kintomo Takakura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kintomo Takakura has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Hiroshi Iseki
Tokyo Women's Medical University
14 shared publications Tatsuya Tanikawa
Department of Neurosurgery, Neurological Institute, Tokyo Women's Medical College, Tokyo,Japan
6 shared publicationsTakaomi Taira
4 shared publications- Yoshihiro Muragaki
Tokyo Women’s Medical University, Tokyo, Japan
4 shared publications Fumitaka Yamane
3 shared publicationsHideaki Onda
3 shared publications
Latest Publications
- 30 November 2012
- Published by Springer Nature
- Vol. 116, 63-69
Gamma Knife Treatment Strategy for Metastatic Brain Tumors
From 1993 to 2011, a total of 3,095 patients with brain metastases underwent Gamma Knife radiosurgery (GKS) at Tokyo Women’s Medical University. Follow-up information on 2,283 of these patients was available for retrospective analysis. The cases were separated into three groups according to the treatment period, the model of the Gamma Knife used, main goals of treatment, and technical nuances of radiosurgery. In the latest cohort of patients treated with the Leksell Gamma Knife model 4C with automatic positioning system, an optimized treatment strategy was applied. It was based on highly selective dose planning, with the use of multiple small isocenters located within the bulk of the mass, which was done for prevention of the excessive irradiation of the perilesional brain and avoidance of its posttreatment edema. In cases of large cystic tumors, selective coverage of the contrast-enhancing capsule with chain-like application of multiple small isocenters was done. Introduction of the new treatment strategy did not affect the 1-year tumor control rate, which was consistently >90 %. However, it did result in a statistically significant reduction of severe posttreatment peritumoral brain edema (from 15.5 % to 6.3 %; P < 0.0001). In conclusion, recent technical and methodological achievements of GKS seemingly do not affect its high efficacy in cases of brain metastasis with regard to tumor control. However, it may result in a prominent reduction of treatment-associated morbidity, which is particularly important in patients with large and/or critically located neoplasm.
- 30 November 2012
- Published by Springer Nature
- Vol. 116, 63-69
Gamma Knife Treatment Strategy for Metastatic Brain Tumors
From 1993 to 2011, a total of 3,095 patients with brain metastases underwent Gamma Knife radiosurgery (GKS) at Tokyo Women’s Medical University. Follow-up information on 2,283 of these patients was available for retrospective analysis. The cases were separated into three groups according to the treatment period, the model of the Gamma Knife used, main goals of treatment, and technical nuances of radiosurgery. In the latest cohort of patients treated with the Leksell Gamma Knife model 4C with automatic positioning system, an optimized treatment strategy was applied. It was based on highly selective dose planning, with the use of multiple small isocenters located within the bulk of the mass, which was done for prevention of the excessive irradiation of the perilesional brain and avoidance of its posttreatment edema. In cases of large cystic tumors, selective coverage of the contrast-enhancing capsule with chain-like application of multiple small isocenters was done. Introduction of the new treatment strategy did not affect the 1-year tumor control rate, which was consistently >90 %. However, it did result in a statistically significant reduction of severe posttreatment peritumoral brain edema (from 15.5 % to 6.3 %; P < 0.0001). In conclusion, recent technical and methodological achievements of GKS seemingly do not affect its high efficacy in cases of brain metastasis with regard to tumor control. However, it may result in a prominent reduction of treatment-associated morbidity, which is particularly important in patients with large and/or critically located neoplasm.
- Open Access
- 1 January 2012
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 3 (4) , 551-569
Information‐Guided Surgery of Intracranial Gliomas: Overview of an Advanced Intraoperative Technology
The objective of this paper is to provide an overview of advanced information‐guided surgical management technology of intracranial gliomas implemented in Japan, represented by the Intelligent Operating Theater at the Tokyo Women’s Medical University, established in 2000, where more than 1000 patients with various intracranial pathology have received neurosurgical treatment with application of the intraoperative MRI, updated neuronavigation, and advanced neurophysiological and histopathological monitoring. Additionally, a dedicated computer‐based system for accumulating, storing, integrating, and analyzing various surgical data was developed, which provided an opportunity for adequate risk management and prediction of the surgical results. Application of these modalities and tools led to significant improvements in both surgical outcome and long‐term patients’ prognosis. Further technological developments, such as new therapeutic robot, dedicated laser, and high intensity focused ultrasound are currently under investigation. The final goal is to integrate all these devices and systems into comprehensive neurosurgical framework.
- 1 January 2012
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 3 (4) , 551-569
Open AccessInformation‐Guided Surgery of Intracranial Gliomas: Overview of an Advanced Intraoperative Technology
The objective of this paper is to provide an overview of advanced information‐guided surgical management technology of intracranial gliomas implemented in Japan, represented by the Intelligent Operating Theater at the Tokyo Women’s Medical University, established in 2000, where more than 1000 patients with various intracranial pathology have received neurosurgical treatment with application of the intraoperative MRI, updated neuronavigation, and advanced neurophysiological and histopathological monitoring. Additionally, a dedicated computer‐based system for accumulating, storing, integrating, and analyzing various surgical data was developed, which provided an opportunity for adequate risk management and prediction of the surgical results. Application of these modalities and tools led to significant improvements in both surgical outcome and long‐term patients’ prognosis. Further technological developments, such as new therapeutic robot, dedicated laser, and high intensity focused ultrasound are currently under investigation. The final goal is to integrate all these devices and systems into comprehensive neurosurgical framework.
- 30 April 2011
- Published by Elsevier in World Neurosurgery
- Vol. 75 (3-4) , 361-363
Professor Keiji Sano: A Notable Figure in Japanese Neurosurgery
- 30 April 2011
- Published by Elsevier in World Neurosurgery
- Vol. 75 (3-4) , 361-363
Professor Keiji Sano: A Notable Figure in Japanese Neurosurgery
- 1 June 2009
- Vol. 36 (6) , 932-7
[Intelligent operating room for surgery of glioma].
- 1 December 2006
- Vol. 58 (12) , 1043-50
[Intraoperative monitoring].
- 1 April 2004
- Vol. 62 (4) , 697-706
[Intraoperative MRI and updated navigation].
Although advanced preoperative imaging has been developed recent years, intraoperative imaging and monitoring are limited. We have developed an operating system to obtain objective and visible information for advanced neurosurgery. Intraoperative MRI and updated navigation are powerful tools to navigate surgeons to the residual lesions. This system has contributed to the improvement of the resection rate and the safety in the cases of gliomas and pituitary tumors.
- 1 April 2004
- Vol. 62 (4) , 697-706
[Intraoperative MRI and updated navigation].
Although advanced preoperative imaging has been developed recent years, intraoperative imaging and monitoring are limited. We have developed an operating system to obtain objective and visible information for advanced neurosurgery. Intraoperative MRI and updated navigation are powerful tools to navigate surgeons to the residual lesions. This system has contributed to the improvement of the resection rate and the safety in the cases of gliomas and pituitary tumors.
- 1 January 2003
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 5 (2) , 75-80
Operating Assisted Imaging from Surgeon's Point of View
- 1 January 2003
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 5 (2) , 75-80
Operating Assisted Imaging from Surgeon's Point of View
- 1 January 2002
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 3 (4) , 267-272
Development of Hitchcock Stereotactic Device for Intraoperative Open MRI
- 1 January 2002
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 3 (4) , 267-272
Development of Hitchcock Stereotactic Device for Intraoperative Open MRI
- 1 January 2000
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 2 (1) , 16-21
A Supporting Device for Surgical Planning Using the Superimposition of Images
Several types of supporting systems for surgical planning have been reported. This paper describes a new surgical supporting device which features image superimposition using a half-mirror. By using the device, graphic image of internal organs can be superimposed on the patient's live image. In order that the device allows users to move around, the position of the user toward the patient was measured consecutively by a small CCD camera placed on the top of a head mounted display (HMD). The CCD camera imaged a patient model with pre-arranged markers on its surface and the position of the model was measured with the accuracy of around 0.5cm by an image processing software. Based on this positional data, three dimensional model data were processed on a workstation to produce graphic image for superimposition. The image was presented to the user through the HMD which features the “see-through” function. The error in navigation by the device was found to be as large as 1cm, particularly at the peripheral view field, and this problem must be solved in the future study.
- 1 January 2000
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 2 (1) , 16-21
A Supporting Device for Surgical Planning Using the Superimposition of Images
Several types of supporting systems for surgical planning have been reported. This paper describes a new surgical supporting device which features image superimposition using a half-mirror. By using the device, graphic image of internal organs can be superimposed on the patient's live image. In order that the device allows users to move around, the position of the user toward the patient was measured consecutively by a small CCD camera placed on the top of a head mounted display (HMD). The CCD camera imaged a patient model with pre-arranged markers on its surface and the position of the model was measured with the accuracy of around 0.5cm by an image processing software. Based on this positional data, three dimensional model data were processed on a workstation to produce graphic image for superimposition. The image was presented to the user through the HMD which features the “see-through” function. The error in navigation by the device was found to be as large as 1cm, particularly at the peripheral view field, and this problem must be solved in the future study.
- 1 January 1999
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 1 (1) , 24-29
Development of Sterilizable Manipulator for Neurosurgery with Separated Drive Mechanism
In recent years the numbers of clinical oriented robots for neurosurgery have been developed, however, up to date, these robots haven't been used in clinical even in experimental operation yet because of many reasons. To solve the mechanical and medical problems in clinical setting, a newly designed needle insertion manipulator for neurosurgery has been developed. This manipulator, a CT image guided manipulator, is designed with following features: detachable mechanical and electrical parts for the sterilization with all axes moving step by step. In this paper, a design concept that clinical manipulators should be and its one solution are described.
- 1 January 1999
- Published by The Japan Society of Computer Aided Surgery in Journal of Japan Society of Computer Aided Surgery
- Vol. 1 (1) , 24-29
Development of Sterilizable Manipulator for Neurosurgery with Separated Drive Mechanism
In recent years the numbers of clinical oriented robots for neurosurgery have been developed, however, up to date, these robots haven't been used in clinical even in experimental operation yet because of many reasons. To solve the mechanical and medical problems in clinical setting, a newly designed needle insertion manipulator for neurosurgery has been developed. This manipulator, a CT image guided manipulator, is designed with following features: detachable mechanical and electrical parts for the sterilization with all axes moving step by step. In this paper, a design concept that clinical manipulators should be and its one solution are described.