STSheng-Hao Tseng

Sheng-Hao Tseng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sheng-Hao Tseng has a total of 57 co-authors. Here are the top co-authors by number of shared publications:

  • Shih-Yu Tzeng

    Research Development and Innovation Center, Show Chwan Health Care System, Changhua City, Taiwan, ROC

    7 shared publications
  • Chao-Kai Hsu

    Department of Dermatology, National Cheng Kung University Hospital, College of Medicine National Cheng Kung University Tainan Taiwan

    6 shared publications
  • Nan-Yu Cheng

    Department of Health-Business Administration, Fooyin University, Kaohsiung, Taiwan, ROC

    6 shared publications
  • Yu-Wen Chen

    Department of Photonics, National Cheng-Kung University, Tainan, 701, Taiwan

    6 shared publications
  • Yun-Yo Yen

    Department of Photonics, National Cheng-Kung University, Tainan, Taiwan, ROC

    4 shared publications
  • Chao-Chun Yang

    Department of Dermatology, College of Medicine, National Cheng Kung University Hospital, National Cheng Kung University, Tainan, Taiwan, ROC

    3 shared publications

Latest Publications

  • Noninvasive hemoglobin quantification across different cohorts using a wearable diffuse reflectance spectroscopy system

    by Ying-Yu Chen, Guan-Hua Lai, Chia-Te Chen, Hsiu-Chi Cheng, Sheng-Hao Tseng

    Quantifying hemoglobin is vital yet invasive through blood draws. We developed a wearable diffuse reflectance spectroscopy device comprising control and sensor boards with photodiodes and light-emitting diodes to noninvasively determine hemoglobin. Neural networks enabled recovery of optical parameters for chromophore fitting to calculate hemoglobin. Testing healthy and elderly subjects revealed strong correlation (r=0.9) between our system and invasive methods after data conversion. Bland-Altman analysis demonstrated tight 95% limits of agreement from −1.98 to 1.98 g/dL between the DRS and invasive hemoglobin concentrations. By spectroscopically isolating hemoglobin absorption, interference from melanin was overcome. Our device has the potential for future integration into wearable technology, enabling hemoglobin level tracking.


  • Open Access

    Non-invasive assessment of skin hydration and sensation with diffuse reflectance spectroscopy

    by Ying-Yu Chen, Shih-Yu Tzeng, Yun-Yo Yen, Nan-Yu Cheng, Sheng-Hao Tseng

    The skin is a vital organ in the human body, providing essential functions such as protection, sensation, and metabolism. Skin hydration is one of the crucial factors in maintaining normal skin function. Insufficient skin hydration can lead to dryness, shedding of the stratum corneum, a decrease in skin barrier function, and may cause skin inflammation. Therefore, maintaining or improving skin hydration is critical in promoting healthy skin. Currently, the commonly used method for measuring skin hydration is bioelectrical capacitance analysis, which is often affected by environmental humidity and can only provide limited information. To overcome these limitations, this study used diffuse reflectance spectroscopy (DRS) in the wavelength range of 400-1000 nm to quantify skin absorption and scattering modulation caused by changes in skin hydration states. The advantages of this technique include rapid measurements, non-invasiveness, a straightforward optical setup, and suitability for prolonged skin monitoring. We found that DRS-derived skin absorption coefficients had a correlation coefficient of 0.93 with the skin capacitance at various skin hydration states. In addition, our findings reveal that absorption and scattering coefficients may be useful in discerning skin hydration enhancement induced by applying soaked cotton pads or cosmeceutical facial masks, as well as evaluating skin sensation. This study verifies that the DRS method could be a convenient and effective tool for evaluating skin hydration related information.


  • Open Access

    Investigating the clinical implication of corneometer and mexameter readings towards objective, efficient evaluation of psoriasis vulgaris severity

    by Chao-Kai Hsu, Nan-Yu Cheng, Chao-Chun Yang, Yun-Yo Yen, Sheng-Hao Tseng

    In clinical settings, although Psoriasis Area and Severity Index (PASI) scoring system can provide a quick visual assessment of the severity of psoriasis vulgaris, there is still a strong demand for higher efficiency and accuracy in quantifying the inflammation status of psoriatic lesions. Currently, there are already commercial systems, such as the Courage + Khazaka Corneometer and Mexameter that measure skin capacitance and optical reflectance, for conveniently quantifying the status of skin barrier function and erythema of skin. Despite numerous comparisons of the Courage + Khazaka system with the PASI scoring system, they are rarely compared on parity with diffuse reflectance spectroscopy (DRS) based systems. In this study, we employed a custom-built DRS system shown to be able to determine the skin water-protein binding status and the hemoglobin concentration, and we performed cross-validation of the DRS measurement results with the readings derived from the Corneometer and Mexameter as well as a portion of the PASI scores. Our results revealed that the erythema readings from the Mexameter were a good representation of skin oxygenated hemoglobin but not the deoxygenated hemoglobin. On the other hand, the dermatologists recruited in this study were inclined to rate higher scores on the “erythema” category as skin’s deoxygenated hemoglobin level was higher. Thus, the Mexameter derived erythema readings may not be coherent with the PASI erythema scores. Further, the Corneometer derived skin capacitance readings were well correlated to the PASI “desquamation” and “thickness” scores, while the PASI “desquamation” evaluation was a dominating factor contributing to the DRS deduced water-protein binding status. We conclude that the DRS method could be a valuable addition to existing skin capacitance/reflectance measurement systems and the PASI scoring system toward achieving a more efficient and objective clinical psoriasis vulgaris severity evaluation.


  • Open Access

    Investigation of water bonding status of normal and psoriatic skin in vivo using diffuse reflectance spectroscopy

    by Chao-Chun Yang, Yun-Yo Yen, Chao-Kai Hsu, Nan-Yu Cheng, Shih-Yu Tzeng, Shih-Jay Chou, Jun-Ming Chang, Sheng-Hao Tseng

    Psoriasis affects more than 125 million people worldwide, and the diagnosis and treatment efficacy evaluation of the disease mainly rely on clinical assessments that could be subjective. Our previous study showed that the skin erythema level could be quantified using diffuse reflectance spectroscopy (DRS), and the hemoglobin concentration of most psoriatic lesion was higher than that of its adjacent uninvolved skin. While the compromised epidermal barrier function has been taken as the major cause of clinical manifestation of skin dryness and inflammation of psoriasis, very few methods can be used to effectively evaluate this function. In this study, we investigate the near infrared spectroscopic features of psoriatic (n = 21) and normal (n = 21) skin that could link to the epidermal barrier function. From the DRS measurements, it was found that the water bonding status and light scattering properties of psoriasis are significantly different from those of uninvolved or normal skin. The connection between these parameters to the epidermal barrier function and morphology will be discussed. Our results suggest that objective evaluation of epidermal barrier function of psoriasis could be achieved using a simple DRS system.


  • Open Access

    Investigation of Water Bonding Status of Normal and Psoriatic Skin in Vivo Using Diffuse Reflectance Spectroscopy

    by Chao-Chun Yang, Yun-Yo Yen, Chao-Kai Hsu, Nan-Yu Cheng, Shih-Yu Tzeng, Shih-Jay Chou, Jun-Ming Chang, Sheng-Hao Tseng

    Psoriasis affects more than 125 million people worldwide, and the diagnosis and treatment efficacy evaluation of the disease mainly rely on clinical assessments that could be subjective. Our previous study showed that the skin erythema level could be quantified using diffuse reflectance spectroscopy (DRS), and the hemoglobin concentration of most psoriatic lesion was higher than that of its adjacent uninvolved skin. While the compromised epidermal barrier function has been taken as the major cause of clinical manifestation of skin dryness and inflammation of psoriasis, very few methods can be used to effectively evaluate this function. In this study, we investigate the near infrared spectroscopic features of psoriatic (n = 21) and normal (n = 21) skin that could link to the epidermal barrier function. From the DRS measurements, it was found that the water bonding status and light scattering properties of psoriasis are significantly different from those of uninvolved or normal skin. The connection between these parameters to the epidermal barrier function and morphology will be discussed. Our results suggest that objective evaluation of epidermal barrier function of psoriasis could be achieved using a simple DRS system.

  • Open Access

    Nondestructive Evaluation of Apple Fruit Quality by Frequency-Domain Diffuse Reflectance Spectroscopy: Variations in Apple Skin and Flesh

    by Nan-Yu Cheng, Chien-Chih Chen, Bo-Jian Liang, Sheng-Hao Tseng

    The optical properties of fruits, such as light absorption and scattering characteristics, change with biochemical activities during storage. Diffuse reflectance spectroscopy (DRS) systems have been widely applied for noninvasively observing biological tissues. In this study, we used a frequency-domain DRS system to measure the optical properties of apples. Results showed that variations in the chlorophyll, water, and flesh-texture of apples could be noninvasively monitored over time. We also observed substantial differences in the absorption and reduced scattering coefficients between injured and normal apples. The DRS techniques could be used for apple grading, and, by extension, for monitoring the quality of other fruits.


  • Noninvasive transcutaneous bilirubin assessment of neonates with hyperbilirubinemia using a photon diffusion theory-based method

    by Nan-Yu Cheng, Yi-Ling Lin, Ming-Chien Fang, Wen-Hsien Lu, Chin-Chieh Yang, Sheng-Hao Tseng

    Transcutaneous bilirubinometers are widely used to screen neonatal jaundice. However, it was reported that their accuracy is compromised at low and high bilirubin levels. We used a photon diffusion theory-based method valid in the 450–600 nm wavelength region to overcome this obstacle. Our clinical study results showed that our system could properly determine the transcutaneous bilirubin concentrations at total serum bilirubin levels higher than 14 mg/dL, where a commercial bilirubinometer failed to provide proper results in several cases. These findings suggested that photon diffusion theory could be employed to improve the core algorithm of modern bilirubinometers and enhance their applicability.


  • Signal Enhancement by Fiber-Dispersion in Sub-GHz Frequency Domain Biophotonic Diagnosis Systems

    by Sheng-Hao Tseng, Tzu-Feng Huang, Jun-Liang Yeh, Ming-Che Chan

    Pulsed lasers can be utilized to generate intensity-modulated light at the fundamental repetition rate and higher-order modulation (HOM) frequencies in our recent study. We also demonstrated the feasibility of using pulse lasers and fiber-wavelength-convertors as a light source in multi-color frequency-domain (FD) bio-photonic systems. In this paper, we present a novel approach to enhance the intensity of signals below 1 GHz in HOM-based FD systems simply by employing fiber dispersion effect. The energy spectrum of HOMs can be redistributed to enhance the intensity of HOMs within the bandwidth of the photo-detector without the need for an external (optical or electrical) amplifier. We also demonstrate that the length of dispersive fiber can be optimized via numerical calculations, the results of which are in good agreement with experimental measurements. Finally, we demonstrate a frequency-domain-photon-migration (FDPM) system employing the fiber dispersion effect to enhance sub-GHz signals at a wavelength of 1.03 μm in order to recover the optical properties of turbid samples. Our measurements results demonstrate the superiority of the proposed FD source over the conventional directly modulated FD light source. Furthermore, the simple configuration of the proposed scheme makes it applicable to a wide range of FD bio-photonic systems.

  • Skin collagen can be accurately quantified through noninvasive optical method: Validation on a swine study

    by S.‐Y. Tzeng, T.‐Y. Kuo, S.‐B. Hu, Y.‐W. Chen, Y.‐L. Lin, K.‐Y. Chu, S.‐H. Tseng

    Background/purpose: Diffuse reflectance spectroscopy (DRS) is a noninvasive optical technology characterized by relatively low system cost and high efficiency. In our previous study, we quantified the relative concentration of collagen for the individual keloid patient. However, no actual value of collagen concentration can prove the reliability of collagen detection by our DRS system.Methods: Skin‐mimicking phantoms were prepared using different collagen and coffee concentrations, and their chromophore concentrations were quantified using the DRS system to analyze the influence of collagen and other chromophores. Moreover, we used the animal study to compare the DRS system with the collagen evaluation of biopsy section by second‐harmonic generation (SHG) microscopy at four different skin parts.Results: In the phantom study, the result showed that coffee chromophore did not severely interfere with collagen concentration recovery. In the animal study, a positive correlation (r=.902) between the DRS system and collagen evaluation with SHG microscopy was found.Conclusions: We have demonstrated that the DRS system can quantify the actual values of collagen concentration and excluded the interference of other chromophores in skin‐mimicking phantoms. Furthermore, a high positive correlation was found in the animal study with SHG microscopy. We consider that the DRS is a potential technique and can evaluate skin condition objectively.


  • Open Access

    Light distribution modulated diffuse reflectance spectroscopy

    by Pin-Yuan Huang, Chun-Yu Chien, Chia-Rong Sheu, Yu-Wen Chen, Sheng-Hao Tseng

    Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation.