Pieter C. Vos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pieter C. Vos has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Henkjan Huisman
Radboud University Medical Center, Radboud Institute for Health Sciences, Nijmegen
5 shared publications - Thomas Hambrock
Division of Cancer Sciences, School of Medical Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester M20 4BX, UK
4 shared publications Jurgen J. Fütterer
2 shared publicationsC. A. Hulsbergen-Van de Kaa
Radboud Univ. Nijmegen Medical Ctr. (Netherlands)
1 shared publicationChristina A. Hulsbergen ‐ van de Kaa
1 shared publicationJ O Barentsz
1 shared publication
Latest Publications
- 6 March 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (6) , 1527-1542
Automatic computer-aided detection of prostate cancer based on multiparametric magnetic resonance image analysis
In this paper, a fully automatic computer-aided detection (CAD) method is proposed for the detection of prostate cancer. The CAD method consists of multiple sequential steps in order to detect locations that are suspicious for prostate cancer. In the initial stage, a voxel classification is performed using a Hessian-based blob detection algorithm at multiple scales on an apparent diffusion coefficient map. Next, a parametric multi-object segmentation method is applied and the resulting segmentation is used as a mask to restrict the candidate detection to the prostate. The remaining candidates are characterized by performing histogram analysis on multiparametric MR images. The resulting feature set is summarized into a malignancy likelihood by a supervised classifier in a two-stage classification approach. The detection performance for prostate cancer was tested on a screening population of 200 consecutive patients and evaluated using the free response operating characteristic methodology. The results show that the CAD method obtained sensitivities of 0.41, 0.65 and 0.74 at false positive (FP) levels of 1, 3 and 5 per patient, respectively. In conclusion, this study showed that it is feasible to automatically detect prostate cancer at a FP rate lower than systematic biopsy. The CAD method may assist the radiologist to detect prostate cancer locations and could potentially guide biopsy towards the most aggressive part of the tumour.
- 6 March 2012
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (6) , 1527-1542
Automatic computer-aided detection of prostate cancer based on multiparametric magnetic resonance image analysis
In this paper, a fully automatic computer-aided detection (CAD) method is proposed for the detection of prostate cancer. The CAD method consists of multiple sequential steps in order to detect locations that are suspicious for prostate cancer. In the initial stage, a voxel classification is performed using a Hessian-based blob detection algorithm at multiple scales on an apparent diffusion coefficient map. Next, a parametric multi-object segmentation method is applied and the resulting segmentation is used as a mask to restrict the candidate detection to the prostate. The remaining candidates are characterized by performing histogram analysis on multiparametric MR images. The resulting feature set is summarized into a malignancy likelihood by a supervised classifier in a two-stage classification approach. The detection performance for prostate cancer was tested on a screening population of 200 consecutive patients and evaluated using the free response operating characteristic methodology. The results show that the CAD method obtained sensitivities of 0.41, 0.65 and 0.74 at false positive (FP) levels of 1, 3 and 5 per patient, respectively. In conclusion, this study showed that it is feasible to automatically detect prostate cancer at a FP rate lower than systematic biopsy. The CAD method may assist the radiologist to detect prostate cancer locations and could potentially guide biopsy towards the most aggressive part of the tumour.
- 2 March 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (6) , 1719-1734
Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI
In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities: T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system: T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.
- 2 March 2010
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 55 (6) , 1719-1734
Computer-assisted analysis of peripheral zone prostate lesions using T2-weighted and dynamic contrast enhanced T1-weighted MRI
In this study, computer-assisted analysis of prostate lesions was researched by combining information from two different magnetic resonance (MR) modalities: T2-weighted (T2-w) and dynamic contrast-enhanced (DCE) T1-w images. Two issues arise when incorporating T2-w images in a computer-aided diagnosis (CADx) system: T2-w values are position as well as sequence dependent and images can be misaligned due to patient movement during the acquisition. A method was developed that computes T2 estimates from a T2-w and proton density value and a known sequence model. A mutual information registration strategy was implemented to correct for patient movement. Global motion is modelled by an affine transformation, while local motion is described by a volume preserving non-rigid deformation based on B-splines. The additional value to the discriminating performance of a DCE T1-w-based CADx system was evaluated using bootstrapped ROC analysis. T2 estimates were successfully computed in 29 patients. T2 values were extracted and added to the CADx system from 39 malignant, 19 benign and 29 normal annotated regions. T2 values alone achieved a diagnostic accuracy of 0.85 (0.77-0.92) and showed a significantly improved discriminating performance of 0.89 (0.81-0.95), when combined with DCE T1-w features. In conclusion, the study demonstrated a simple T2 estimation method that has a diagnostic performance such that it complements a DCE T1-w-based CADx system in discriminating malignant lesions from normal and benign regions. Additionally, the T2 estimate is beneficial to visual inspection due to the removed coil profile and fixed window and level settings.
- 1 January 2009
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 12, 836-843
Automated Calibration for Computerized Analysis of Prostate Lesions Using Pharmacokinetic Magnetic Resonance Images
The feasibility of an automated calibration method for estimating the arterial input function when calculating pharmacokinetic parameters from Dynamic Contrast Enhanced MRI is shown. In a previous study [1], it was demonstrated that the computer aided diagnoses (CADx) system performs optimal when per patient calibration was used, but required manual annotation of reference tissue. In this study we propose a fully automated segmentation method that tackles this limitation and tested the method with our CADx system when discriminating prostate cancer from benign areas in the peripheral zone. A method was developed to automatically segment normal peripheral zone tissue (PZ). Context based segmentation using the Otsu histogram based threshold selection method and by Hessian based blob detection, was developed to automatically select PZ as reference tissue for the per patient calibration. In 38 consecutive patients carcinoma, benign and normal tissue were annotated on MR images by a radiologist and a researcher using whole mount step-section histopathology as standard of reference. A feature set comprising pharmacokinetic parameters was computed for each ROI and used to train a support vector machine (SVM) as classifier. In total 42 malignant, 29 benign and 37 normal regions were annotated. The diagnostic accuracy obtained for differentiating malignant from benign lesions using a conventional general patient plasma profile showed an accuracy of 0.65 (0.54-0.76). Using the automated segmentation per patient calibration method the diagnostic value improved to 0.80 (0.71-0.88), whereas the manual segmentation per patient calibration showed a diagnostic performance of 0.80 (0.70-0.90). These results show that an automated per-patient calibration is feasible, a significant better discriminating performance compared to the conventional fixed calibration was obtained and the diagnostic accuracy is similar to using manual per-patient calibration.
- 1 January 2009
- Published by Springer Nature in Lecture Notes in Computer Science
- Vol. 12, 836-843
Automated Calibration for Computerized Analysis of Prostate Lesions Using Pharmacokinetic Magnetic Resonance Images
The feasibility of an automated calibration method for estimating the arterial input function when calculating pharmacokinetic parameters from Dynamic Contrast Enhanced MRI is shown. In a previous study [1], it was demonstrated that the computer aided diagnoses (CADx) system performs optimal when per patient calibration was used, but required manual annotation of reference tissue. In this study we propose a fully automated segmentation method that tackles this limitation and tested the method with our CADx system when discriminating prostate cancer from benign areas in the peripheral zone. A method was developed to automatically segment normal peripheral zone tissue (PZ). Context based segmentation using the Otsu histogram based threshold selection method and by Hessian based blob detection, was developed to automatically select PZ as reference tissue for the per patient calibration. In 38 consecutive patients carcinoma, benign and normal tissue were annotated on MR images by a radiologist and a researcher using whole mount step-section histopathology as standard of reference. A feature set comprising pharmacokinetic parameters was computed for each ROI and used to train a support vector machine (SVM) as classifier. In total 42 malignant, 29 benign and 37 normal regions were annotated. The diagnostic accuracy obtained for differentiating malignant from benign lesions using a conventional general patient plasma profile showed an accuracy of 0.65 (0.54-0.76). Using the automated segmentation per patient calibration method the diagnostic value improved to 0.80 (0.71-0.88), whereas the manual segmentation per patient calibration showed a diagnostic performance of 0.80 (0.70-0.90). These results show that an automated per-patient calibration is feasible, a significant better discriminating performance compared to the conventional fixed calibration was obtained and the diagnostic accuracy is similar to using manual per-patient calibration.
- 13 February 2008
- Published by Wiley in Medical Physics
- Vol. 35 (3) , 888-899
Computerized analysis of prostate lesions in the peripheral zone using dynamic contrast enhanced MRI
A novel automated computerized scheme has been developed for determining a likelihood measure of malignancy for cancer suspicious regions in the prostate based on dynamic contrast‐enhanced magnetic resonance imaging (MRI) (DCE‐MRI) images. Our database consisted of 34 consecutive patients with histologically proven adenocarcinoma in the peripheral zone of the prostate. Both carcinoma and non‐malignant tissue were annotated in consensus on MR images by a radiologist and a researcher using whole mount step‐section histopathology as standard of reference. The annotations were used as regions of interest (ROIs). A feature set comprising pharmacokinetic parameters and a T1 estimate was extracted from the ROIs to train a support vector machine as classifier. The output of the classifier was used as a measure of likelihood of malignancy. Diagnostic performance of the scheme was evaluated using the area under the ROC curve. The diagnostic accuracy obtained for differentiating prostate cancer from non‐malignant disorders in the peripheral zone was 0.83 (0.75–0.92). This suggests that it is feasible to develop a computer aided diagnosis system capable of characterizing prostate cancer in the peripheral zone based on DCE‐MRI.
- 13 February 2008
- Published by Wiley in Medical Physics
- Vol. 35 (3) , 888-899
Computerized analysis of prostate lesions in the peripheral zone using dynamic contrast enhanced MRI
A novel automated computerized scheme has been developed for determining a likelihood measure of malignancy for cancer suspicious regions in the prostate based on dynamic contrast‐enhanced magnetic resonance imaging (MRI) (DCE‐MRI) images. Our database consisted of 34 consecutive patients with histologically proven adenocarcinoma in the peripheral zone of the prostate. Both carcinoma and non‐malignant tissue were annotated in consensus on MR images by a radiologist and a researcher using whole mount step‐section histopathology as standard of reference. The annotations were used as regions of interest (ROIs). A feature set comprising pharmacokinetic parameters and a T1 estimate was extracted from the ROIs to train a support vector machine as classifier. The output of the classifier was used as a measure of likelihood of malignancy. Diagnostic performance of the scheme was evaluated using the area under the ROC curve. The diagnostic accuracy obtained for differentiating prostate cancer from non‐malignant disorders in the peripheral zone was 0.83 (0.75–0.92). This suggests that it is feasible to develop a computer aided diagnosis system capable of characterizing prostate cancer in the peripheral zone based on DCE‐MRI.
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6514
Effect of calibration on computerized analysis of prostate lesions using quantitative dynamic contrast-enhanced magnetic resonance imaging
In this study, we investigated the effect of different patient calibration methods on the performance of our CAD system when discriminating prostate cancer from non-malignant suspicious enhancing areas in the peripheral zone and the normal peripheral zone. Our database consisted of 34 consecutive patients with histologically proven adenocarcinoma of the prostate. Both carcinoma and normal tissue were annotated on MR images by a radiologist and a researcher using whole mount step-section histopathology as standard of reference. The annotated regions were used as regions of interest in the contrast enhanced MRI images. A feature set comprising pharmacokinetic parametes was extracted from the ROIs to train a support vector machine as classifier. The output of the classifier was used as a measure of likelihood of malignancy. General performance of the scheme was evaluated using the area under the ROC curve. The diagnostic accuracy obtained for differentiating normal peripheral zone and non-malignant suspicious enhancing areas from malignant lesions was 0.88 (0.81-0.95) when per patient calibration was performed, whereas fixed calibration resulted in a diagnostic accuracy of 0.77 (0.69-0.85). These preliminary results indicate that when per patient calibration is used, the performance is improved with statistical significance (p=0.026).
- 8 March 2007
- Published by SPIE-Intl Soc Optical Eng
- Vol. 6514
Effect of calibration on computerized analysis of prostate lesions using quantitative dynamic contrast-enhanced magnetic resonance imaging
In this study, we investigated the effect of different patient calibration methods on the performance of our CAD system when discriminating prostate cancer from non-malignant suspicious enhancing areas in the peripheral zone and the normal peripheral zone. Our database consisted of 34 consecutive patients with histologically proven adenocarcinoma of the prostate. Both carcinoma and normal tissue were annotated on MR images by a radiologist and a researcher using whole mount step-section histopathology as standard of reference. The annotated regions were used as regions of interest in the contrast enhanced MRI images. A feature set comprising pharmacokinetic parametes was extracted from the ROIs to train a support vector machine as classifier. The output of the classifier was used as a measure of likelihood of malignancy. General performance of the scheme was evaluated using the area under the ROC curve. The diagnostic accuracy obtained for differentiating normal peripheral zone and non-malignant suspicious enhancing areas from malignant lesions was 0.88 (0.81-0.95) when per patient calibration was performed, whereas fixed calibration resulted in a diagnostic accuracy of 0.77 (0.69-0.85). These preliminary results indicate that when per patient calibration is used, the performance is improved with statistical significance (p=0.026).