Shin Fujita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Shin Fujita has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Hiroshi Shimoyama
5 shared publicationsMasahiro Takebe
Production/Design Technology Center , Shimadzu Corporation , 1, Nishinokyo-Kuwabaracho, Nakagyo-ku, Kyoto 604-8511 , Japan
2 shared publicationsChuhei Oshima
1 shared publication- Eiji Rokuta
Department of Materials Science and Engineering, Faculty of Science and Engineering, Meijo University, Japan
1 shared publication H. Sato
Production/Design Technology Center, Shimadzu Corporation, Kyoto, Japan
1 shared publication- Hidekazu Murata
Faculty of Science and Technology,Meijo University,Tempaku-ku,Nagoya 468-8502,Japan
1 shared publication
Latest Publications
- 1 November 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (11) , 115001
Field Emission Microscopy Study of Au-Covered Nanopyramids with 211-Facet Sides Grown on Blunt W Tips via Assistive Remolding Treatment
- 1 November 2011
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 50 (11) , 115001
Field Emission Microscopy Study of Au-Covered Nanopyramids with 211-Facet Sides Grown on Blunt W Tips via Assistive Remolding Treatment
- 16 August 2010
- Published by Wiley in Journal of Microscopy
- Vol. 239 (3) , 215-222
Enhanced angular current intensity from Schottky emitters
Even though the Schottky emitter is a high-brightness source of choice for electron beam systems, its angular current intensity is substantially lower than that of thermionic cathodes, rendering the emitter impractical for applications that require high beam current. In this study, two strategies were attempted to enhance its angular intensity, and their experimental results are reported. The first scheme is to employ a higher extraction field for increasing the brightness. However, the tip shape transformation was found to induce undesirably elevated emission from the facet edges at high fields. The second scheme exploits the fact that the angular intensity is proportional to the square of the electron gun focal length [Fujita, S. & Shimoyama, H. (2005) Theory of cathode trajectory characterization by canonical mapping transformation. J. Electron Microsc. 54, 331-343], which can be increased by scaling-up the emitter tip radius. A high angular current intensity (J(Omega) approximately 1.5 mA sr(-1)) was obtained from a scaled-up emitter. Preliminary performance tests were conducted on an electron probe-forming column by substituting the new emitter for the original tungsten filament gun. The beam current up to a few microamperes was achieved with submicron spatial resolution.
- 16 August 2010
- Published by Wiley in Journal of Microscopy
- Vol. 239 (3) , 215-222
Enhanced angular current intensity from Schottky emitters
Even though the Schottky emitter is a high-brightness source of choice for electron beam systems, its angular current intensity is substantially lower than that of thermionic cathodes, rendering the emitter impractical for applications that require high beam current. In this study, two strategies were attempted to enhance its angular intensity, and their experimental results are reported. The first scheme is to employ a higher extraction field for increasing the brightness. However, the tip shape transformation was found to induce undesirably elevated emission from the facet edges at high fields. The second scheme exploits the fact that the angular intensity is proportional to the square of the electron gun focal length [Fujita, S. & Shimoyama, H. (2005) Theory of cathode trajectory characterization by canonical mapping transformation. J. Electron Microsc. 54, 331-343], which can be increased by scaling-up the emitter tip radius. A high angular current intensity (J(Omega) approximately 1.5 mA sr(-1)) was obtained from a scaled-up emitter. Preliminary performance tests were conducted on an electron probe-forming column by substituting the new emitter for the original tungsten filament gun. The beam current up to a few microamperes was achieved with submicron spatial resolution.
- 3 June 2010
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 59 (5) , 351-358
Characterization of curved cathode guns by the generalized trajectory method: upgrade of G-optk programme for applications to non-planar objects
A mathematical scheme has been proposed to extend the applicability of the generalized trajectory method to deal with curved cathodes such as cold field emitters and thermionic point cathodes. A connecting space is introduced between the cathode surface and the first reference plane, and the actual ray condition on the cathode is transformed into the trajectory condition at the reference plane: the generalized trajectory calculation is commenced from the reference plane. The electron acceleration due to the cathode surface field, which results in the increase of the transverse momentum px at the reference plane, has been found to significantly influence the estimate of the spherical aberration coefficient. The new mathematical formulation has been incorporated into the upgraded G-optk programme and enabled it to carry out precise characterization of curved cathode guns.
- 3 June 2010
- Published by Oxford University Press (OUP) in Journal of Electron Microscopy
- Vol. 59 (5) , 351-358
Characterization of curved cathode guns by the generalized trajectory method: upgrade of G-optk programme for applications to non-planar objects
A mathematical scheme has been proposed to extend the applicability of the generalized trajectory method to deal with curved cathodes such as cold field emitters and thermionic point cathodes. A connecting space is introduced between the cathode surface and the first reference plane, and the actual ray condition on the cathode is transformed into the trajectory condition at the reference plane: the generalized trajectory calculation is commenced from the reference plane. The electron acceleration due to the cathode surface field, which results in the increase of the transverse momentum px at the reference plane, has been found to significantly influence the estimate of the spherical aberration coefficient. The new mathematical formulation has been incorporated into the upgraded G-optk programme and enabled it to carry out precise characterization of curved cathode guns.
- 4 August 2009
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 59 (1) , 3-15
Generalization of the paraxial trajectory method for the analysis of non-paraxial rays: simulation program G-optk for electron gun characterization
The paraxial trajectory method has been generalized for the application to the cathode rays inside electron guns. The generalized method can handle rays that initially make a large angle with the optical axis with a satisfactory accuracy. The key to success of the generalization is the adoption of the trigonometric function sine for the trajectory slope specification, instead of the conventional use of the tangent. Formulas have been derived to relate the ray conditions (position and slope of the ray at reference planes) on the cathode to those at the crossover plane using third-order polynomial functions. Some of the polynomial coefficients can be used as the optical parameters in the characterization of electron sources; the electron gun focal length gives a quantitative estimate of both the crossover size and the angular current intensity. An electron gun simulation program G-optk has been developed based on the mathematical formulations presented in the article. The program calculates the principal paraxial trajectories and the relevant optical parameters from axial potentials and fields. It gives the electron-optical-column designers a clear physical picture of the electron gun in a much more faster way than the conventional ray-tracing methods.
- 4 August 2009
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 59 (1) , 3-15
Generalization of the paraxial trajectory method for the analysis of non-paraxial rays: simulation program G-optk for electron gun characterization
The paraxial trajectory method has been generalized for the application to the cathode rays inside electron guns. The generalized method can handle rays that initially make a large angle with the optical axis with a satisfactory accuracy. The key to success of the generalization is the adoption of the trigonometric function sine for the trajectory slope specification, instead of the conventional use of the tangent. Formulas have been derived to relate the ray conditions (position and slope of the ray at reference planes) on the cathode to those at the crossover plane using third-order polynomial functions. Some of the polynomial coefficients can be used as the optical parameters in the characterization of electron sources; the electron gun focal length gives a quantitative estimate of both the crossover size and the angular current intensity. An electron gun simulation program G-optk has been developed based on the mathematical formulations presented in the article. The program calculates the principal paraxial trajectories and the relevant optical parameters from axial potentials and fields. It gives the electron-optical-column designers a clear physical picture of the electron gun in a much more faster way than the conventional ray-tracing methods.
- 21 June 2007
- Published by American Physical Society (APS) in Physical Review B
- Vol. 75 (23) , 235431
Mechanism of surface-tension reduction by electric-field application: Shape changes in single-crystal field emitters under thermal-field treatment
The shape change of the ⟨100⟩-oriented tungsten single-crystal field emitter tip under thermal-field (TF) treatment was systematically studied with increasing remolding field (i.e., reversely polarized field opposite to field-emission polarity) at a constant temperature. The initially hemispherical emitter tip builds up to polyhedral shapes with increasing remolding voltage. These shapes are formed by certain low-index crystal planes. On further increase of the voltage, an overremolding state is reached in which the emitter takes a rugged surface structure. A thermodynamic model is proposed to explain the buildup mechanism utilizing the reduction of the surface tension under the influence of a strong electric field. The theory assumes the emitter-extractor system to comprise an electric capacitor and includes the electrostatic-field energy stored around the emitter into the system under consideration. It is shown that the electrostatic-field energy term in the Gibbs free energy could be interpreted as an effective reduction of the surface tension. The initially moderate anisotropy of the intrinsic surface tension is increasingly enhanced by the electrostatic-field energy through the reduction mechanism. The facets on the emitter surface consequently develop in accordance with the Wulff construction of the equilibrium crystal shape (ECS). By application of an electric field, the surface free-energy anisotropy can be made large enough to induce complete faceting of the crystal even at an elevated temperature where the crystal shape can immediately follow the ECS.
- 21 June 2007
- Published by American Physical Society (APS) in Physical Review B
- Vol. 75 (23) , 235431
Mechanism of surface-tension reduction by electric-field application: Shape changes in single-crystal field emitters under thermal-field treatment
The shape change of the ⟨100⟩-oriented tungsten single-crystal field emitter tip under thermal-field (TF) treatment was systematically studied with increasing remolding field (i.e., reversely polarized field opposite to field-emission polarity) at a constant temperature. The initially hemispherical emitter tip builds up to polyhedral shapes with increasing remolding voltage. These shapes are formed by certain low-index crystal planes. On further increase of the voltage, an overremolding state is reached in which the emitter takes a rugged surface structure. A thermodynamic model is proposed to explain the buildup mechanism utilizing the reduction of the surface tension under the influence of a strong electric field. The theory assumes the emitter-extractor system to comprise an electric capacitor and includes the electrostatic-field energy stored around the emitter into the system under consideration. It is shown that the electrostatic-field energy term in the Gibbs free energy could be interpreted as an effective reduction of the surface tension. The initially moderate anisotropy of the intrinsic surface tension is increasingly enhanced by the electrostatic-field energy through the reduction mechanism. The facets on the emitter surface consequently develop in accordance with the Wulff construction of the equilibrium crystal shape (ECS). By application of an electric field, the surface free-energy anisotropy can be made large enough to induce complete faceting of the crystal even at an elevated temperature where the crystal shape can immediately follow the ECS.
- 30 September 2005
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 54 (5) , 413-427
A new evaluation method of electron optical performance of high beam current probe forming systems
A new numerical simulation method is presented for the electron optical property analysis of probe forming systems with point cathode guns such as cold field emitters and the Schottky emitters. It has long been recognized that the gun aberrations are important parameters to be considered since the intrinsically high brightness of the point cathode gun is reduced due to its spherical aberration. The simulation method can evaluate the ‘threshold beam current Ith’ above which the apparent brightness starts to decrease from the intrinsic value. It is found that the threshold depends on the ‘electron gun focal length’ as well as on the spherical aberration of the gun. Formulas are presented to estimate the brightness reduction as a function of the beam current. The gun brightness reduction must be included when the probe property (the relation between the beam current lb and the probe size on the sample, d) of the entire electron optical column is evaluated. Formulas that explicitly consider the gun aberrations into account are presented. It is shown that the probe property curve consists of three segments in the order of increasing beam current: (i) the constant probe size region, (ii) the brightness limited region where the probe size increases as \(d\ {\sim}\ I_{\mathrm{b}}^{3/8}\) , and (iii) the angular current intensity limited region in which the beam size increases rapidly as \(d\ {\sim}\ I_{\mathrm{b}}^{3/2}\) . Some strategies are suggested to increase the threshold beam current and to extend the effective beam current range of the point cathode gun into micro ampere regime.- 30 September 2005
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 54 (5) , 413-427
A new evaluation method of electron optical performance of high beam current probe forming systems
A new numerical simulation method is presented for the electron optical property analysis of probe forming systems with point cathode guns such as cold field emitters and the Schottky emitters. It has long been recognized that the gun aberrations are important parameters to be considered since the intrinsically high brightness of the point cathode gun is reduced due to its spherical aberration. The simulation method can evaluate the ‘threshold beam current Ith’ above which the apparent brightness starts to decrease from the intrinsic value. It is found that the threshold depends on the ‘electron gun focal length’ as well as on the spherical aberration of the gun. Formulas are presented to estimate the brightness reduction as a function of the beam current. The gun brightness reduction must be included when the probe property (the relation between the beam current lb and the probe size on the sample, d) of the entire electron optical column is evaluated. Formulas that explicitly consider the gun aberrations into account are presented. It is shown that the probe property curve consists of three segments in the order of increasing beam current: (i) the constant probe size region, (ii) the brightness limited region where the probe size increases as \(d\ {\sim}\ I_{\mathrm{b}}^{3/8}\) , and (iii) the angular current intensity limited region in which the beam size increases rapidly as \(d\ {\sim}\ I_{\mathrm{b}}^{3/2}\) . Some strategies are suggested to increase the threshold beam current and to extend the effective beam current range of the point cathode gun into micro ampere regime.- Open Access
- 1 August 2005
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 54 (4) , 331-343
Theory of cathode trajectory characterization by canonical mapping transformation
The paraxial lens theory cannot directly be applied to the cathode trajectories inside the gun. This inconvenience makes the interpretation of cathode trajectories difficult since one cannot use the physical concepts familiar in the paraxial lens theory, such as focal length and magnification factor. We have proposed the canonical mapping transformation (CMT) to describe the electron trajectories inside the gun by relating the ray conditions on the cathode surface to those in the crossover plane. The method takes as variables the distance along the surface and the sine of the ray angle with respect to the surface normal to define ray conditions. It has been shown that the CMT can be characterized by a small number of optical parameters. One of the parameters is the ‘electron gun focal length’, an extension of the image side focal length in the paraxial lens theory. The crossover size of a triode gun can be calculated from the electron gun focal length and the initial transverse energy spread. The calculation predicts the dependence of the crossover size on the grid voltage due to the change in the electron gun focal length. The prediction is compared with the measurement and shows good agreement with it. Since the CMT optical parameters can be calculated from the representative trajectories only and as they predict practically all the necessary source properties of guns, the CMT can be used as a practical tool in the designing of various types of electron guns.
- 1 August 2005
- Published by Oxford University Press (OUP) in Microscopy
- Vol. 54 (4) , 331-343
Open AccessTheory of cathode trajectory characterization by canonical mapping transformation
The paraxial lens theory cannot directly be applied to the cathode trajectories inside the gun. This inconvenience makes the interpretation of cathode trajectories difficult since one cannot use the physical concepts familiar in the paraxial lens theory, such as focal length and magnification factor. We have proposed the canonical mapping transformation (CMT) to describe the electron trajectories inside the gun by relating the ray conditions on the cathode surface to those in the crossover plane. The method takes as variables the distance along the surface and the sine of the ray angle with respect to the surface normal to define ray conditions. It has been shown that the CMT can be characterized by a small number of optical parameters. One of the parameters is the ‘electron gun focal length’, an extension of the image side focal length in the paraxial lens theory. The crossover size of a triode gun can be calculated from the electron gun focal length and the initial transverse energy spread. The calculation predicts the dependence of the crossover size on the grid voltage due to the change in the electron gun focal length. The prediction is compared with the measurement and shows good agreement with it. Since the CMT optical parameters can be calculated from the representative trajectories only and as they predict practically all the necessary source properties of guns, the CMT can be used as a practical tool in the designing of various types of electron guns.