Colton H. F. Wong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Colton H. F. Wong has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Terence See Ming Wan
Racing Laboratory The Hong Kong Jockey Club, Sha Tin Racecourse Sha Tin New Territories Hong Kong, China
3 shared publications David K.K. Leung
Racing Laboratory, The Hong Kong Jockey Club, Sha Tin Racecourse, Sha Tin, N.T., Hong Kong, China
2 shared publicationsFrancis P.W. Tang
Racing Laboratory, The Hong Kong Jockey Club, Sha Tin Racecourse, Sha Tin, N.T., Hong Kong, China
2 shared publications- Gary Ngai‐Wa Leung
Drug Analysis Department Laboratory of Racing Chemistry Utsunomiya Japan
2 shared publications Nola H. Yu
Racing Laboratory, The Hong Kong Jockey Club Sha Tin Racecourse Sha Tin N.T. Hong Kong, China
2 shared publications- Wai Him Kwok
Racing Laboratory The Hong Kong Jockey Club, Sha Tin Racecourse Sha Tin, N. T Hong Kong China
2 shared publications
Latest Publications
- 26 June 2012
- Published by Wiley in Drug Testing and Analysis
- Vol. 4 (12) , 1028-1033
Interconversion of ephedrine and pseudoephedrine during chemical derivatization
Gas chromatography–mass spectrometry (GC‐MS) analysis after heptafluorobutyric anhydride (HFBA) derivatization was one of the published methods used for the quantification of ephedrine (EP) and pseudoephedrine (PE) in urine. This method allows the clear separation of the derivatized diastereoisomers on a methyl‐silicone‐based column. Recently the authors came across a human urine sample with apparently high levels (µg/ml) of EP and PE upon initial screening. However, duplicate analyses of this sample using the HFBA‐GC‐MS method revealed an unusual discrepancy in the estimated levels of EP and PE, with the area response ratios of EP/PE at around 29% on one occasion and around 57% on another. The same sample was re‐analyzed for EP and PE using other techniques, including GC‐MS after trimethylsilylation and ultra‐high‐performance liquid chromatography‐tandem mass spectrometry. Surprisingly, the concentration of EP in the sample was determined to be at least two orders of magnitude less than what was observed with the HFBA‐GC‐MS method. A thorough investigation was then conducted, and the results showed that both substances could interconvert during HFBA derivatization. Similar diastereoisomeric conversion was also observed using other fluorinated acylating agents (e.g. pentafluoropropionic anhydride and trifluoroacetic anhydride). The extent of interconversion was correlated with the degree of fluorination of the acylating agents, with HFBA giving the highest conversion. This conversion has never been reported before. A mechanism for the interconversion was proposed. These findings indicated that fluorinated acylating agents should not be used for the unequivocal identification or quantification of EP and PE as the results obtained can be erroneous. Copyright © 2012 John Wiley & Sons, Ltd.
- 26 June 2012
- Published by Wiley in Drug Testing and Analysis
- Vol. 4 (12) , 1028-1033
Interconversion of ephedrine and pseudoephedrine during chemical derivatization
Gas chromatography–mass spectrometry (GC‐MS) analysis after heptafluorobutyric anhydride (HFBA) derivatization was one of the published methods used for the quantification of ephedrine (EP) and pseudoephedrine (PE) in urine. This method allows the clear separation of the derivatized diastereoisomers on a methyl‐silicone‐based column. Recently the authors came across a human urine sample with apparently high levels (µg/ml) of EP and PE upon initial screening. However, duplicate analyses of this sample using the HFBA‐GC‐MS method revealed an unusual discrepancy in the estimated levels of EP and PE, with the area response ratios of EP/PE at around 29% on one occasion and around 57% on another. The same sample was re‐analyzed for EP and PE using other techniques, including GC‐MS after trimethylsilylation and ultra‐high‐performance liquid chromatography‐tandem mass spectrometry. Surprisingly, the concentration of EP in the sample was determined to be at least two orders of magnitude less than what was observed with the HFBA‐GC‐MS method. A thorough investigation was then conducted, and the results showed that both substances could interconvert during HFBA derivatization. Similar diastereoisomeric conversion was also observed using other fluorinated acylating agents (e.g. pentafluoropropionic anhydride and trifluoroacetic anhydride). The extent of interconversion was correlated with the degree of fluorination of the acylating agents, with HFBA giving the highest conversion. This conversion has never been reported before. A mechanism for the interconversion was proposed. These findings indicated that fluorinated acylating agents should not be used for the unequivocal identification or quantification of EP and PE as the results obtained can be erroneous. Copyright © 2012 John Wiley & Sons, Ltd.
- 1 April 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1232, 257-265
Rapid screening of anabolic steroids in horse urine with ultra-high-performance liquid chromatography/tandem mass spectrometry after chemical derivatisation
- 1 April 2012
- Published by Elsevier in Journal of Chromatography A
- Vol. 1232, 257-265
Rapid screening of anabolic steroids in horse urine with ultra-high-performance liquid chromatography/tandem mass spectrometry after chemical derivatisation
- 1 July 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 697 (1-2) , 48-60
A broad-spectrum equine urine screening method for free and enzyme-hydrolysed conjugated drugs with ultra performance liquid chromatography/tandem mass spectrometry
- 1 July 2011
- Published by Elsevier in Analytica Chimica Acta
- Vol. 697 (1-2) , 48-60
A broad-spectrum equine urine screening method for free and enzyme-hydrolysed conjugated drugs with ultra performance liquid chromatography/tandem mass spectrometry
- 7 May 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (19) , 3289-3296
Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography–tandem mass spectrometry
- 7 May 2010
- Published by Elsevier in Journal of Chromatography A
- Vol. 1217 (19) , 3289-3296
Screening of drugs in equine plasma using automated on-line solid-phase extraction coupled with liquid chromatography–tandem mass spectrometry