Alfonso A. Isola
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alfonso A. Isola has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Wiro J. Niessen
Erasmus MC
5 shared publications M. Grass
3 shared publicationsA. Ziegler
Philips Technologie GmbH Forschungslaboratorien, Roentgenstrasse 24-26, D-22335 Hamburg, Germany
2 shared publicationsD. Schäfer
Philips Technologie GmbH Forschungslaboratorien, Roentgenstrasse 24-26, D-22335 Hamburg, Germany
2 shared publicationsM Grass
Philips
2 shared publicationsT. Köhler
Philips Technologie GmbH Forschungslaboratorien, Roentgenstrasse 24-26, D-22335 Hamburg, Germany
2 shared publications
Latest Publications
- Open Access
- 2 December 2019
- Published by MDPI AG in Healthcare
- Vol. 7 (4) , 153
Comparison between Conventional IMRT Planning and a Novel Real-Time Adaptive Planning Strategy in Hypofractionated Regimes for Prostate Cancer: A Proof-of-Concept Planning Study
In prostate cancer external beam radiation therapy (EBRT), intra-fraction prostate drifts may compromise the treatment efficacy by underdosing the target and/or overdosing the organs at risk. In this study, a recently developed real-time adaptive planning strategy for intensity-modulated radiation therapy (IMRT) for prostate cancer was evaluated in hypofractionated regimes against traditional treatment planning based on a treatment volume margin expansion. The proposed workflow makes use of a “library of plans” corresponding to possible intra-fraction prostate positions. During delivery, at each beam end, the plan prepared for the position of the prostate closest to the current one is selected and the corresponding beam delivered. This adaptive planning strategy was compared with the traditional approach on a clinical prostate cancer case where different prostate shift magnitudes were considered. Five, six and fifteen fraction hypofractionated schemes were considered for each of these scenarios. When shifts larger than the treatment margin were present, using the traditional approach the seminal vesicles were underdosed by 3–4% of the prescribed dose. The adaptive approach instead allowed for correct target dose coverage and lowered the dose on the rectum for each dosimetric endpoint on average by 3–4% in all the fractionation schemes. Standard intensity-modulated radiation therapy planning did not always guarantee a correct dose distribution on the seminal vesicles and the rectum. The adaptive planning strategy proposed resulted insensitive to the intra-fraction prostate drifts, produced a dose distribution in agreement with the dosimetric requirements in every case analysed and significantly lowered the dose on the rectum.
- 2 December 2019
- Published by MDPI AG in Healthcare
- Vol. 7 (4) , 153
Open AccessComparison between Conventional IMRT Planning and a Novel Real-Time Adaptive Planning Strategy in Hypofractionated Regimes for Prostate Cancer: A Proof-of-Concept Planning Study
In prostate cancer external beam radiation therapy (EBRT), intra-fraction prostate drifts may compromise the treatment efficacy by underdosing the target and/or overdosing the organs at risk. In this study, a recently developed real-time adaptive planning strategy for intensity-modulated radiation therapy (IMRT) for prostate cancer was evaluated in hypofractionated regimes against traditional treatment planning based on a treatment volume margin expansion. The proposed workflow makes use of a “library of plans” corresponding to possible intra-fraction prostate positions. During delivery, at each beam end, the plan prepared for the position of the prostate closest to the current one is selected and the corresponding beam delivered. This adaptive planning strategy was compared with the traditional approach on a clinical prostate cancer case where different prostate shift magnitudes were considered. Five, six and fifteen fraction hypofractionated schemes were considered for each of these scenarios. When shifts larger than the treatment margin were present, using the traditional approach the seminal vesicles were underdosed by 3–4% of the prescribed dose. The adaptive approach instead allowed for correct target dose coverage and lowered the dose on the rectum for each dosimetric endpoint on average by 3–4% in all the fractionation schemes. Standard intensity-modulated radiation therapy planning did not always guarantee a correct dose distribution on the seminal vesicles and the rectum. The adaptive planning strategy proposed resulted insensitive to the intra-fraction prostate drifts, produced a dose distribution in agreement with the dosimetric requirements in every case analysed and significantly lowered the dose on the rectum.
- 1 April 2012
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 36 (3) , 215-226
Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction
- 1 April 2012
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 36 (3) , 215-226
Cardiac motion-corrected iterative cone-beam CT reconstruction using a semi-automatic minimum cost path-based coronary centerline extraction
- Open Access
- 22 August 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (18) , 5925-5947
Image registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT
Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.
- 22 August 2011
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 56 (18) , 5925-5947
Open AccessImage registration and analysis for quantitative myocardial perfusion: application to dynamic circular cardiac CT
Large area detector computed tomography systems with fast rotating gantries enable volumetric dynamic cardiac perfusion studies. Prospectively, ECG-triggered acquisitions limit the data acquisition to a predefined cardiac phase and thereby reduce x-ray dose and limit motion artefacts. Even in the case of highly accurate prospective triggering and stable heart rate, spatial misalignment of the cardiac volumes acquired and reconstructed per cardiac cycle may occur due to small motion pattern variations from cycle to cycle. These misalignments reduce the accuracy of the quantitative analysis of myocardial perfusion parameters on a per voxel basis. An image-based solution to this problem is elastic 3D image registration of dynamic volume sequences with variable contrast, as it is introduced in this contribution. After circular cone-beam CT reconstruction of cardiac volumes covering large areas of the myocardial tissue, the complete series is aligned with respect to a chosen reference volume. The results of the registration process and the perfusion analysis with and without registration are evaluated quantitatively in this paper. The spatial alignment leads to improved quantification of myocardial perfusion for three different pig data sets.
- 1 March 2010
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 34 (2) , 149-159
Motion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT
- 1 March 2010
- Published by Elsevier in Computerized Medical Imaging and Graphics
- Vol. 34 (2) , 149-159
Motion compensated iterative reconstruction of a region of interest in cardiac cone-beam CT
- 16 February 2010
- Published by Wiley in Medical Physics
- Vol. 37 (3) , 1093-1109
Fully automatic nonrigid registration‐based local motion estimation for motion‐corrected iterative cardiac CT reconstruction
Purpose: Cardiac computed tomography is a rapidly emerging technique for noninvasive diagnosis of cardiovascular diseases. Nevertheless, the cardiac motion continues to be a limiting factor. Electrocardiogram‐gated cardiac computed tomography reconstruction methods yield excellent results, but these are limited in their temporal resolution due to the mechanical movement of the gantry, and lead to residual motion blurring artifacts. If the motion of the cardiac region of interest is determined, motion compensated gated reconstructions can be applied to reduce motion artifacts. In this paper it is shown that elastic image registration methods can be an accurate solution to determine the cardiac motion. A method, which combines elastic registration and iterative computed tomography reconstruction methods delivering motion‐corrected images of a chosen cardiac region of interest, is introduced.Methods: Using a gated four‐dimensional region of interest image data set, a fully automatic elastic image registration is applied to recover a cardiac displacement field from a reference phase to a number of phases within the RR interval. Here, a stochastic optimizer and multiresolution approach are adopted to speed up the registration process. Subsequently, motion‐compensated iterative reconstruction using the determined motion field is carried out. For the image representation volume‐adapted spherical basis functions (blobs) are used to take the volume change caused by a divergent motion vector field into account.Results: The method is evaluated on phantom data and on four clinical data sets at a strong cardiac motion phase. Comparing the method to standard gated iterative reconstruction results shows that motion compensation strongly improves the image quality in these phases. A qualitative and quantitative accuracy study is presented for the estimated cardiac motion field. For the first time a blob‐volume adaptation is applied on clinical data, and in the case of divergent motion it yields improved image quality.Conclusions: A fully automatic local cardiac motion compensated gated iterative method with volume‐adapted blobs is proposed. The method leads to excellent motion‐corrected images which outperform nonmotion corrected results in phases of strong cardiac motion. In clinical cases, a volume‐dependent blob‐footprint adaptation proves to be a good solution to take care of the change in the blob volume caused by a divergent motion field.
- 16 February 2010
- Published by Wiley in Medical Physics
- Vol. 37 (3) , 1093-1109
Fully automatic nonrigid registration‐based local motion estimation for motion‐corrected iterative cardiac CT reconstruction
Purpose: Cardiac computed tomography is a rapidly emerging technique for noninvasive diagnosis of cardiovascular diseases. Nevertheless, the cardiac motion continues to be a limiting factor. Electrocardiogram‐gated cardiac computed tomography reconstruction methods yield excellent results, but these are limited in their temporal resolution due to the mechanical movement of the gantry, and lead to residual motion blurring artifacts. If the motion of the cardiac region of interest is determined, motion compensated gated reconstructions can be applied to reduce motion artifacts. In this paper it is shown that elastic image registration methods can be an accurate solution to determine the cardiac motion. A method, which combines elastic registration and iterative computed tomography reconstruction methods delivering motion‐corrected images of a chosen cardiac region of interest, is introduced.Methods: Using a gated four‐dimensional region of interest image data set, a fully automatic elastic image registration is applied to recover a cardiac displacement field from a reference phase to a number of phases within the RR interval. Here, a stochastic optimizer and multiresolution approach are adopted to speed up the registration process. Subsequently, motion‐compensated iterative reconstruction using the determined motion field is carried out. For the image representation volume‐adapted spherical basis functions (blobs) are used to take the volume change caused by a divergent motion vector field into account.Results: The method is evaluated on phantom data and on four clinical data sets at a strong cardiac motion phase. Comparing the method to standard gated iterative reconstruction results shows that motion compensation strongly improves the image quality in these phases. A qualitative and quantitative accuracy study is presented for the estimated cardiac motion field. For the first time a blob‐volume adaptation is applied on clinical data, and in the case of divergent motion it yields improved image quality.Conclusions: A fully automatic local cardiac motion compensated gated iterative method with volume‐adapted blobs is proposed. The method leads to excellent motion‐corrected images which outperform nonmotion corrected results in phases of strong cardiac motion. In clinical cases, a volume‐dependent blob‐footprint adaptation proves to be a good solution to take care of the change in the blob volume caused by a divergent motion field.
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 646-650
Motion compensated iterative reconstruction of a cardiac region of interest for CT
- 1 January 2009
- Published by Springer Nature in IFMBE Proceedings
- p. 646-650
Motion compensated iterative reconstruction of a cardiac region of interest for CT
- 7 November 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (23) , 6777-6797
Motion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions
This paper presents a three-dimensional method to reconstruct moving objects from cone-beam X-ray projections using an iterative reconstruction algorithm and a given motion vector field. For the image representation, adapted blobs are used, which can be implemented efficiently as basis functions. Iterative reconstruction requires the calculation of line integrals (forward projections) through the image volume, which are compared with the actual measurements to update the image volume. In the existence of a divergent motion vector field, a change in the volumes of the blobs has to be taken into account in the forward and backprojections. An efficient method to calculate the line integral through the adapted blobs is proposed. It solves the problem, how to compensate for the divergence in the motion vector field on a grid of basis functions. The method is evaluated on two phantoms, which are subject to three different known motions. Moreover, a motion-compensated filtered back-projection reconstruction method is used, and the reconstructed images are compared. Using the correct motion vector field with the iterative motion-compensated reconstruction, sharp images are obtained, with a quality that is significantly better than gated reconstructions.
- 7 November 2008
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (23) , 6777-6797
Motion-compensated iterative cone-beam CT image reconstruction with adapted blobs as basis functions
This paper presents a three-dimensional method to reconstruct moving objects from cone-beam X-ray projections using an iterative reconstruction algorithm and a given motion vector field. For the image representation, adapted blobs are used, which can be implemented efficiently as basis functions. Iterative reconstruction requires the calculation of line integrals (forward projections) through the image volume, which are compared with the actual measurements to update the image volume. In the existence of a divergent motion vector field, a change in the volumes of the blobs has to be taken into account in the forward and backprojections. An efficient method to calculate the line integral through the adapted blobs is proposed. It solves the problem, how to compensate for the divergence in the motion vector field on a grid of basis functions. The method is evaluated on two phantoms, which are subject to three different known motions. Moreover, a motion-compensated filtered back-projection reconstruction method is used, and the reconstructed images are compared. Using the correct motion vector field with the iterative motion-compensated reconstruction, sharp images are obtained, with a quality that is significantly better than gated reconstructions.