Charles-Hilaire Rivard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charles-Hilaire Rivard has a total of 218 co-authors. Here are the top co-authors by number of shared publications:
Christine Coillard
Paediatric Research Center
5 shared publications- Christine Coillard
Sainte Justine Hospital, Montreal, Canada
3 shared publications - Michel Assad
Orthopedics and Biomaterials Laboratory, AccelLAB Inc., Boisbriand, Quebec, Canada
3 shared publications Alexandr Chernyshov
2 shared publicationsFidèle Likibi
Paediatric Research Center
2 shared publicationsGary L. Lowery
2 shared publications
Latest Publications
- Open Access
- 15 January 2009
- Published by Springer Nature in Scoliosis and Spinal Disorders
- Vol. 4 (S1) , O34
SpineCore treatment for early scoliosis: 15° to 24°
- 15 January 2009
- Published by Springer Nature in Scoliosis and Spinal Disorders
- Vol. 4 (S1) , O34
Open AccessSpineCore treatment for early scoliosis: 15° to 24°
- 1 January 2008
- Published by Elsevier
Contributors
- 17 November 2005
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 15 (4) , 257-263
Influence of biomaterial structure and hardness on its osseo-integration: histomorphometric evaluation of porous nitinol and titanium implants
- 17 November 2005
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 15 (4) , 257-263
Influence of biomaterial structure and hardness on its osseo-integration: histomorphometric evaluation of porous nitinol and titanium implants
- Open Access
- 14 March 2005
- Published by Association of Spine Surgeons in Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika)
- No. 1,p. 105-111
THE EFFECT OF SEGMENTAL PEDICLE SCREW INSTRUMENTATION ON ACTIVELY GROWING SPINE: A LONG-TERM EXPERIMENTAL STUDY*
Objectives. To determine the biological response of growing spine to rigid segmental fixation. Summary of background data. Pedicle screw is gaining popularity in pediatric deformities. Yet, biological response of actively growing spine to rigid pedicle screw fixation remains unclear. Methods. Twelve mini pigs in actively growing period were subjected to posterior segmental screw-rod instrumentation spanning 9 levels and creation of experimental scoliosis. There was no attempt of posterior arthrodesis. The pigs were subjected to periodic radiological examinations and were euthanized at 18 months for analysis. Results. There was no significant fixation failure despite conspicuous growth of the animals. Initial scoliosis of 31 ± 5° was reduced to 27 ± 8° at 18months, but there was no statistical significance (p=0.37). Though there was no change in length of the implant construct, the vertebrae within the instrumented section showed mean longitudinal growth of 6 ± 3 mm (p = 0.000). The growth occurred at expense of the disc spaces that progressively narrowed with time. On necropsy, the instrumented region was completely fused posteriorly with crossing of the osseous traberculae across the former facet joints. Intervertebral discs were severely atrophic in all the discs with occasional spontaneous fusion. Conclusions. Even in the actively growing spine, the force of growth does not overcome the fixation offered by segmental pedicle screws. Longitudinal growth occurs at the expense of the joint spaces and leads to spontaneous intervertebral fusion. Our results may explain the favorable outcomes in pedicle fixations in pediatric population, showing little implant failure or nonunion.
- 14 March 2005
- Published by Association of Spine Surgeons in Russian Journal of Spine Surgery (Khirurgiya Pozvonochnika)
- No. 1,p. 105-111
Open AccessTHE EFFECT OF SEGMENTAL PEDICLE SCREW INSTRUMENTATION ON ACTIVELY GROWING SPINE: A LONG-TERM EXPERIMENTAL STUDY*
Objectives. To determine the biological response of growing spine to rigid segmental fixation. Summary of background data. Pedicle screw is gaining popularity in pediatric deformities. Yet, biological response of actively growing spine to rigid pedicle screw fixation remains unclear. Methods. Twelve mini pigs in actively growing period were subjected to posterior segmental screw-rod instrumentation spanning 9 levels and creation of experimental scoliosis. There was no attempt of posterior arthrodesis. The pigs were subjected to periodic radiological examinations and were euthanized at 18 months for analysis. Results. There was no significant fixation failure despite conspicuous growth of the animals. Initial scoliosis of 31 ± 5° was reduced to 27 ± 8° at 18months, but there was no statistical significance (p=0.37). Though there was no change in length of the implant construct, the vertebrae within the instrumented section showed mean longitudinal growth of 6 ± 3 mm (p = 0.000). The growth occurred at expense of the disc spaces that progressively narrowed with time. On necropsy, the instrumented region was completely fused posteriorly with crossing of the osseous traberculae across the former facet joints. Intervertebral discs were severely atrophic in all the discs with occasional spontaneous fusion. Conclusions. Even in the actively growing spine, the force of growth does not overcome the fixation offered by segmental pedicle screws. Longitudinal growth occurs at the expense of the joint spaces and leads to spontaneous intervertebral fusion. Our results may explain the favorable outcomes in pedicle fixations in pediatric population, showing little implant failure or nonunion.
- Open Access
- 10 March 2005
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 6 (1) , 14
Assessment of the paraspinal muscles of subjects presenting an idiopathic scoliosis: an EMG pilot study
Background: It is known that the back muscles of scoliotic subjects present abnormalities in their fiber type composition. Some researchers have hypothesized that abnormal fiber composition can lead to paraspinal muscle dysfunction such as poor neuromuscular efficiency and muscle fatigue. EMG parameters were used to evaluate these impairments. The purpose of the present study was to examine the clinical potential of different EMG parameters such as amplitude (RMS) and median frequency (MF) of the power spectrum in order to assess the back muscles of patients presenting idiopathic scoliosis in terms of their neuromuscular efficiency and their muscular fatigue. Methods: L5/S1 moments during isometric efforts in extension were measured in six subjects with idiopathic scoliosis and ten healthy controls. The subjects performed three 7 s ramp contractions ranging from 0 to 100% maximum voluntary contraction (MVC) and one 30 s sustained contraction at 75% MVC. Surface EMG activity was recorded bilaterally from the paraspinal muscles at L5, L3, L1 and T10. The slope of the EMG RMS/force (neuromuscular efficiency) and MF/force (muscle composition) relationships were computed during the ramp contractions while the slope of the EMG RMS/time and MF/time relationships (muscle fatigue) were computed during the sustained contraction. Comparisons were performed between the two groups and between the left and right sides for the EMG parameters. Results: No significant group or side differences between the slopes of the different measures used were found at the level of the apex (around T10) of the major curve of the spine. However, a significant side difference was seen at a lower level (L3, p = 0.01) for the MF/time parameter. Conclusion: The EMG parameters used in this study could not discriminate between the back muscles of scoliotic subjects and those of control subject regarding fiber type composition, neuromuscular efficiency and muscle fatigue at the level of the apex. The results of this pilot study indicate that compensatory strategies are potentially seen at lower level of the spine with these EMG parameters.
- 10 March 2005
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 6 (1) , 14
Open AccessAssessment of the paraspinal muscles of subjects presenting an idiopathic scoliosis: an EMG pilot study
Background: It is known that the back muscles of scoliotic subjects present abnormalities in their fiber type composition. Some researchers have hypothesized that abnormal fiber composition can lead to paraspinal muscle dysfunction such as poor neuromuscular efficiency and muscle fatigue. EMG parameters were used to evaluate these impairments. The purpose of the present study was to examine the clinical potential of different EMG parameters such as amplitude (RMS) and median frequency (MF) of the power spectrum in order to assess the back muscles of patients presenting idiopathic scoliosis in terms of their neuromuscular efficiency and their muscular fatigue. Methods: L5/S1 moments during isometric efforts in extension were measured in six subjects with idiopathic scoliosis and ten healthy controls. The subjects performed three 7 s ramp contractions ranging from 0 to 100% maximum voluntary contraction (MVC) and one 30 s sustained contraction at 75% MVC. Surface EMG activity was recorded bilaterally from the paraspinal muscles at L5, L3, L1 and T10. The slope of the EMG RMS/force (neuromuscular efficiency) and MF/force (muscle composition) relationships were computed during the ramp contractions while the slope of the EMG RMS/time and MF/time relationships (muscle fatigue) were computed during the sustained contraction. Comparisons were performed between the two groups and between the left and right sides for the EMG parameters. Results: No significant group or side differences between the slopes of the different measures used were found at the level of the apex (around T10) of the major curve of the spine. However, a significant side difference was seen at a lower level (L3, p = 0.01) for the MF/time parameter. Conclusion: The EMG parameters used in this study could not discriminate between the back muscles of scoliotic subjects and those of control subject regarding fiber type composition, neuromuscular efficiency and muscle fatigue at the level of the apex. The results of this pilot study indicate that compensatory strategies are potentially seen at lower level of the spine with these EMG parameters.
- 19 November 2004
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 14 (4) , 209-213
Osseointegration study of porous nitinol versus titanium orthopaedic implants
- 19 November 2004
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 14 (4) , 209-213
Osseointegration study of porous nitinol versus titanium orthopaedic implants
- 1 April 2003
- Published by Springer Nature in European Spine Journal
- Vol. 12 (2) , 141-148
SpineCor – a non-rigid brace for the treatment of idiopathic scoliosis: post-treatment results
The objective of this study was to assess the success of treatment during the follow-up of a group of 195 idiopathic scoliosis (IS) patients consecutively treated with the SpineCor system. A survival analysis was performed to estimate the cumulative probability of success during treatment, at follow-up and for the combined treatment and follow-up period. Success was defined as either a correction or stabilization of ±5° or more, and failure as a worsening of more than 5°. The patient cohort was categorized before treatment into curves less than 30° (group 1), and curves greater than 30° (group 2). The survival analysis indicated a cumulative probability of success that increased during treatment with the patient wearing the brace (Year 1: 0.30, 0.39; Year 2: 0.62, 0.79; Year 3: 0.92, 0.89, for groups 1 and 2 respectively). During the post-treatment follow-up period, there was a stabilization (Year 1 post-treatment: 0.94, 0.89; Year 2 post-treatment: 0.85, 0.81), with an overall probability of success of 0.92 and 0.88 after 4 years of combined treatment and post-treatment follow-up. For the 29 patients who had a minimum follow-up of 2 years (initial Cobb angle: 30°±9°), the trend during treatment was a decrease in spinal curvature at 3 months, with a mean difference of 10° (SD 5°); at termination of treatment a mean difference of 7° (SD 7°); and at the time of the 1- and 2-year follow-ups there was a difference of 4° (SD 7°) and 5° (SD 7°) respectively, with reference to the initial out of brace condition. At 2 years follow-up there was an overall correction of greater than 5° for 55% of the patients, 38% had a stabilisation and 7% had worsened by more than 5°. This initial cohort of patients demonstrated a general trend of initial decrease in spinal curvature in brace, followed by a correction and/or stabilisation at the end of treatment, which was maintained through 1, and 2 years’ follow-up.
- 1 April 2003
- Published by Springer Nature in European Spine Journal
- Vol. 12 (2) , 141-148
SpineCor – a non-rigid brace for the treatment of idiopathic scoliosis: post-treatment results
The objective of this study was to assess the success of treatment during the follow-up of a group of 195 idiopathic scoliosis (IS) patients consecutively treated with the SpineCor system. A survival analysis was performed to estimate the cumulative probability of success during treatment, at follow-up and for the combined treatment and follow-up period. Success was defined as either a correction or stabilization of ±5° or more, and failure as a worsening of more than 5°. The patient cohort was categorized before treatment into curves less than 30° (group 1), and curves greater than 30° (group 2). The survival analysis indicated a cumulative probability of success that increased during treatment with the patient wearing the brace (Year 1: 0.30, 0.39; Year 2: 0.62, 0.79; Year 3: 0.92, 0.89, for groups 1 and 2 respectively). During the post-treatment follow-up period, there was a stabilization (Year 1 post-treatment: 0.94, 0.89; Year 2 post-treatment: 0.85, 0.81), with an overall probability of success of 0.92 and 0.88 after 4 years of combined treatment and post-treatment follow-up. For the 29 patients who had a minimum follow-up of 2 years (initial Cobb angle: 30°±9°), the trend during treatment was a decrease in spinal curvature at 3 months, with a mean difference of 10° (SD 5°); at termination of treatment a mean difference of 7° (SD 7°); and at the time of the 1- and 2-year follow-ups there was a difference of 4° (SD 7°) and 5° (SD 7°) respectively, with reference to the initial out of brace condition. At 2 years follow-up there was an overall correction of greater than 5° for 55% of the patients, 38% had a stabilisation and 7% had worsened by more than 5°. This initial cohort of patients demonstrated a general trend of initial decrease in spinal curvature in brace, followed by a correction and/or stabilisation at the end of treatment, which was maintained through 1, and 2 years’ follow-up.
- 30 August 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 62 (4) , 488-498
In vivo biocompatibility testing of peek polymer for a spinal implant system: A study in rabbits
We are developing a new spinal implant system (SIS) without fusion (bone graft). This SIS is made from two materials, metal and polyetheretherketone (PEEK) polymer. The Food and Drug Administration recommended testing in vivo, in an animal model, whether the PEEK polymer could be used in a SIS without any harm of wear debris to the nervous tissue (spinal cord and nerve roots). The objective was to evaluate the biological response of the spinal cord and nerve roots (dura mater) to PEEK polymer particles. Twenty‐four female New Zealand white rabbits were used. The rabbits were divided into three groups: test (n = 12), control (n = 9), and sham (n = 3). During the surgery, the test group received the PEEK particle injections (5 × 107 particles per site, lumbar and thoracic), while the control group received only the vehicle (0.9% saline solution). The sham group had the same surgical approach without injection. In each group, the rabbits were euthanized at 1, 4, and 12 weeks postsurgery. The macroscopic and semiquantitative histologic analyses of the spinal cords (dura mater) showed normal vascularization and particle adherence to the connective tissue especially at the injection sites. Neither necrosis nor swelling of the dura mater and nerve roots was observed. The PEEK polymer is harmless to the spinal cord; thus it might be used as component in the spinal implant system. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 62: 488–498, 2002
- 30 August 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 62 (4) , 488-498
In vivo biocompatibility testing of peek polymer for a spinal implant system: A study in rabbits
We are developing a new spinal implant system (SIS) without fusion (bone graft). This SIS is made from two materials, metal and polyetheretherketone (PEEK) polymer. The Food and Drug Administration recommended testing in vivo, in an animal model, whether the PEEK polymer could be used in a SIS without any harm of wear debris to the nervous tissue (spinal cord and nerve roots). The objective was to evaluate the biological response of the spinal cord and nerve roots (dura mater) to PEEK polymer particles. Twenty‐four female New Zealand white rabbits were used. The rabbits were divided into three groups: test (n = 12), control (n = 9), and sham (n = 3). During the surgery, the test group received the PEEK particle injections (5 × 107 particles per site, lumbar and thoracic), while the control group received only the vehicle (0.9% saline solution). The sham group had the same surgical approach without injection. In each group, the rabbits were euthanized at 1, 4, and 12 weeks postsurgery. The macroscopic and semiquantitative histologic analyses of the spinal cords (dura mater) showed normal vascularization and particle adherence to the connective tissue especially at the injection sites. Neither necrosis nor swelling of the dura mater and nerve roots was observed. The PEEK polymer is harmless to the spinal cord; thus it might be used as component in the spinal implant system. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 62: 488–498, 2002
- 1 January 2002
- Vol. 12 (3) , 225-37
A new porous titanium-nickel alloy: Part 1. Cytotoxicity and genotoxicity evaluation.
Porous titanium-nickel (PTN) alloys represent new biomaterials for long-term implantation. Their porosity properties might confer them the capacity to trigger fluid capillarity, tissue ingrowth, as well as good tissue-implant apposition and fixation. Before PTN materials are used as long-term implants, their biocompatibility level must be assessed. In this study, porous titanium-nickel was therefore extracted in a saline semi-physiological solution and materials were evaluated for potential cytotoxicity and genotoxicity reactions. The cytocompatibility elution test was performed in order to determine PTN toxic potential at the in vitro cellular level: no reactivity was detected in cell layers exposed to PTN extracts or the negative controls. In parallel, the genocompatibility of porous titanium-nickel was evaluated using three different assays in order to assess potential damage at the DNA level: the test for chemical induction of chromosome aberrations, the Salmonella typhimurium and Escherichia coli reverse mutation assay, and the mouse micronucleus test. No significant increase in the number of chromosomal aberrations, bacterian revertant colonies, or micronuclei was observed in presence of PTN extracts when compared to negative control exposition. Based on the above results, porous titanium-nickel can be considered completely cytocompatible and genocompatible, and therefore represents a good candidate for long-term implantation.
- 1 January 2002
- Vol. 12 (3) , 225-37
A new porous titanium-nickel alloy: Part 1. Cytotoxicity and genotoxicity evaluation.
Porous titanium-nickel (PTN) alloys represent new biomaterials for long-term implantation. Their porosity properties might confer them the capacity to trigger fluid capillarity, tissue ingrowth, as well as good tissue-implant apposition and fixation. Before PTN materials are used as long-term implants, their biocompatibility level must be assessed. In this study, porous titanium-nickel was therefore extracted in a saline semi-physiological solution and materials were evaluated for potential cytotoxicity and genotoxicity reactions. The cytocompatibility elution test was performed in order to determine PTN toxic potential at the in vitro cellular level: no reactivity was detected in cell layers exposed to PTN extracts or the negative controls. In parallel, the genocompatibility of porous titanium-nickel was evaluated using three different assays in order to assess potential damage at the DNA level: the test for chemical induction of chromosome aberrations, the Salmonella typhimurium and Escherichia coli reverse mutation assay, and the mouse micronucleus test. No significant increase in the number of chromosomal aberrations, bacterian revertant colonies, or micronuclei was observed in presence of PTN extracts when compared to negative control exposition. Based on the above results, porous titanium-nickel can be considered completely cytocompatible and genocompatible, and therefore represents a good candidate for long-term implantation.