Juan Rodríguez-Carvajal
Juan Rodríguez-Carvajal has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Maria Rosa Palacin
Institut de Ciència de Materials de Barcelona, ICMAB-CSIC, Campus UAB, 08193 Bellaterra, Catalonia, Spain
1 shared publication - Montse Casas-Cabanas
CIC Energigune
1 shared publication
Latest Publications
- 1 December 2005
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 20 (4) , 334-344
Microstructural analysis of nickel hydroxide: Anisotropic size versus stacking faults
Two different approaches for studying sample’s contributions to diffraction-line broadening are analyzed by applying them to several nickel hydroxide samples. Both are based in the refinement of powder diffraction data but differ in the microstructural model used. The first one consists in the refinement of the powder diffraction pattern using the FAULTS program, a modification of DIFFaX , which assigns peak broadening mainly to the presence of stacking faults and treats finite size effects by convolution with a Voigt function. The second method makes use of the program FULLPROF , which allows the use of linear combinations of spherical harmonics to model peak broadening coming from anisotropic size effects. The complementary use of transmission electron microscopy has allowed us to evaluate the best approach for the Ni(OH) 2 case. In addition, peak shifts, corresponding to reflections 10 l ( l ≠0) were observed in defective nickel hydroxide samples that can be directly correlated with the degree of faulting.
- 1 December 2005
- Published by Cambridge University Press (CUP) in Powder Diffraction
- Vol. 20 (4) , 334-344
Microstructural analysis of nickel hydroxide: Anisotropic size versus stacking faults
Two different approaches for studying sample’s contributions to diffraction-line broadening are analyzed by applying them to several nickel hydroxide samples. Both are based in the refinement of powder diffraction data but differ in the microstructural model used. The first one consists in the refinement of the powder diffraction pattern using the FAULTS program, a modification of DIFFaX , which assigns peak broadening mainly to the presence of stacking faults and treats finite size effects by convolution with a Voigt function. The second method makes use of the program FULLPROF , which allows the use of linear combinations of spherical harmonics to model peak broadening coming from anisotropic size effects. The complementary use of transmission electron microscopy has allowed us to evaluate the best approach for the Ni(OH) 2 case. In addition, peak shifts, corresponding to reflections 10 l ( l ≠0) were observed in defective nickel hydroxide samples that can be directly correlated with the degree of faulting.