Jacobus F Van Staden
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jacobus F Van Staden has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Raluca-Ioana Stefan
Department of Chemistry, University of Pretoria, Pretoria 0002, South Africa
6 shared publicationsHassan Y. Aboul-Enein
Bioanalytical and Drug Development Laboratory, Biological and Medical Research Department (MBC-03), King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211, Saudi Arabia
3 shared publicationsH. Y. Aboul-Enein
Bioanalytical and Drug Development Laboratory, Biological and Medical Research Department (MBC-03), King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211, Saudi Arabia SA
2 shared publicationsHassan Y Aboul-Enein
Bioanalytical and Drug Development Laboratory, Biological and Medical Research Department (MBC-03), King Faisal Specialist Hospital and Research Centre, P.O. Box 3354, Riyadh 11211, Saudi Arabia
2 shared publications- Negussie Beyene
Anti-Persoonsmijnen Ontmijnende Product Ontwikkeling, Sokoine University of Agriculture, Morogoro, Tanzania
2 shared publications R. I. Stefan
University of Pretoria
2 shared publications
Latest Publications
- 26 June 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (5-6) , 750-753
3rd International Conference on Instrumental Methods of Analysis: Modern Trends and Applications, 23–27 September 2003, Thessaloniki, Greece
- 26 June 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (5-6) , 750-753
3rd International Conference on Instrumental Methods of Analysis: Modern Trends and Applications, 23–27 September 2003, Thessaloniki, Greece
- 3 April 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 375 (8) , 1074-1082
On-line speciation of bromine and bromide using sequential injection analysis with spectrophotometric detection
An on-line procedure for the simultaneous determination of bromine and total bromine (bromine+bromide oxidised to bromine) is proposed, which lead to the determination of bromide by subtraction. Phenol red was used as chromogenic reagent for bromine and total bromine after bromide was oxidised to bromine by Chloramine T. The linear range found is 1–10 mg L−1 with a detection limit of 0.6 mg L−1 for bromine, and a linear range of 0.8–15 mg L−1 with a detection limit of 0.4 mg L−1 for total bromine. The calculated RSD for bromine is less than 0.8% and for total bromine less than 0.7%. The system is fully computerised and able to run 30 samples per hour with an automated rinsing step that eliminates sample carry-over. The results for both bromine and bromide from the proposed sequential injection analysis (SIA) system compare favourably with standard manual methods and statistical evaluation proves no significant difference between the results of the proposed SIA system and the standard method at the 95% confidence level. The presence of other halides was found not to interfere.
- 3 April 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 375 (8) , 1074-1082
On-line speciation of bromine and bromide using sequential injection analysis with spectrophotometric detection
An on-line procedure for the simultaneous determination of bromine and total bromine (bromine+bromide oxidised to bromine) is proposed, which lead to the determination of bromide by subtraction. Phenol red was used as chromogenic reagent for bromine and total bromine after bromide was oxidised to bromine by Chloramine T. The linear range found is 1–10 mg L−1 with a detection limit of 0.6 mg L−1 for bromine, and a linear range of 0.8–15 mg L−1 with a detection limit of 0.4 mg L−1 for total bromine. The calculated RSD for bromine is less than 0.8% and for total bromine less than 0.7%. The system is fully computerised and able to run 30 samples per hour with an automated rinsing step that eliminates sample carry-over. The results for both bromine and bromide from the proposed sequential injection analysis (SIA) system compare favourably with standard manual methods and statistical evaluation proves no significant difference between the results of the proposed SIA system and the standard method at the 95% confidence level. The presence of other halides was found not to interfere.
- 1 September 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (1) , 3-12
New horizons in sequential injection kinetic analysis
The need to measure several quantities rapidly in the same sample has prompted the development of automated methods of analysis that in both the continuous and discontinuous modes offer the possibility of simultaneous determinations. The application of pH gradients and differential kinetic determinations dominate the simultaneous determination of two or more closely related species in mixtures without prior separation. Various options enable use of kinetic-based measurements for the simultaneous determination of different analytes in flow systems. Some possible general reactions are given and discussed. The scope of sequential injection kinetic analysis is illustrated with examples.
- 1 September 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (1) , 3-12
New horizons in sequential injection kinetic analysis
The need to measure several quantities rapidly in the same sample has prompted the development of automated methods of analysis that in both the continuous and discontinuous modes offer the possibility of simultaneous determinations. The application of pH gradients and differential kinetic determinations dominate the simultaneous determination of two or more closely related species in mixtures without prior separation. Various options enable use of kinetic-based measurements for the simultaneous determination of different analytes in flow systems. Some possible general reactions are given and discussed. The scope of sequential injection kinetic analysis is illustrated with examples.
- 1 October 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 371 (3) , 376-379
Determination of zinc in pharmaceutical products by use of a sequential injection analysis system
A sequential injection analysis (SIA) system is proposed for the determination of zinc in pharmaceutical samples. The method is based on the spectrophotometric detection of zinc using xylenol orange as a colour reagent at 568 nm. The system can be used to monitor zinc at a frequency of 30 samples h–1 with an average recovery of ±98.5% and a relative standard deviation of less than 1%. A linear relationship between peak height and zinc concentration is obtained between 10 and 60 mg L–1. The results obtained are in good agreement with those obtained by use of a standard method.
- 1 October 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 371 (3) , 376-379
Determination of zinc in pharmaceutical products by use of a sequential injection analysis system
A sequential injection analysis (SIA) system is proposed for the determination of zinc in pharmaceutical samples. The method is based on the spectrophotometric detection of zinc using xylenol orange as a colour reagent at 568 nm. The system can be used to monitor zinc at a frequency of 30 samples h–1 with an average recovery of ±98.5% and a relative standard deviation of less than 1%. A linear relationship between peak height and zinc concentration is obtained between 10 and 60 mg L–1. The results obtained are in good agreement with those obtained by use of a standard method.