Zahid Amin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zahid Amin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Kiran Mallula
Rush Center for Congenital and Structural Heart Disease, Rush University Medical Center, 1653 West Congress Parkway, Jones 770, Chicago, IL, 60612, USA
2 shared publicationsZiyad M. Hijazi
Rush Center for Congenital and Structural Heart Disease, Rush University Medical Center, Chicago, Illinois
2 shared publicationsCharles S. Kleinman
1 shared publication- Damien Kenny
Rush Center for Congenital and Structural Heart Disease, Rush University Medical Center, Chicago, Illinois
1 shared publication Darren Berman
Division of Pediatric Cardiology, Miami Children's Hospital, Miami, Florida
1 shared publicationEvan Zahn
Division of Pediatric Cardiology, Miami Children's Hospital, Miami, Florida
1 shared publication
Latest Publications
- 9 August 2013
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 82 (5) , 824-827
Perventricular melody valve implantation in a 12 kg child
Transcatheter pulmonic valve implantation has emerged as a safe and effective alternative to valve surgery in patients with surgically corrected congenital heart disease. In cases where the transcatheter approach has failed, or was thought to be technically challenging, a hybrid approach to pulmonic valve implantation has been described. This approach involves a small subxyphoid incision made by the cardiac surgeon and implantation of the pulmonic valve through the appropriate delivery sheath through this incision. Here we describe a case of a successful implantation of a Melody valve in a 12 kg child with tetralogy of Fallot. To our knowledge this is the smallest child to have undergone this procedure reported.
- 9 August 2013
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 82 (5) , 824-827
Perventricular melody valve implantation in a 12 kg child
Transcatheter pulmonic valve implantation has emerged as a safe and effective alternative to valve surgery in patients with surgically corrected congenital heart disease. In cases where the transcatheter approach has failed, or was thought to be technically challenging, a hybrid approach to pulmonic valve implantation has been described. This approach involves a small subxyphoid incision made by the cardiac surgeon and implantation of the pulmonic valve through the appropriate delivery sheath through this incision. Here we describe a case of a successful implantation of a Melody valve in a 12 kg child with tetralogy of Fallot. To our knowledge this is the smallest child to have undergone this procedure reported.
- 2 February 2013
- Published by Springer Nature in Pediatric Cardiology
- Vol. 34 (8) , 2068-2072
New Design of the Amplatzer Membranous VSD Occluder: A Step Forward?
Closure of perimembranous ventricular septal defects (PmVSDs) [4] with the original Amplatzer membranous VSD occluder (mVSD1) has been associated with an increased risk of complications, the most notable of which has been complete heart block. This has led to the introduction of a new device to close PmVSDs. The authors describe their experience with the new Amplatzer membranous VSD occluder (mVSD2) in two patients and critique the new device design and delivery system, comparing it with the mVSD1 occluder. Two patients underwent attempted closure of PmVSDs with the new mVSD2 device. One patient had successful closure of the defect with no residual shunt and no evidence of heart block at follow-up evaluation. Trace to mild aortic insufficiency was observed at the time of closure and at the last follow-up visit. The rhythm remained sinus. In the second patient, the device was placed but removed before release because of inability to orient the device in optimal position. Percutaneous closure of PmVSD is feasible with the new mVSD2 occluder. The change in the design may reduce the incidence of complete heart block. It remains to be seen whether the device will be suitable for smaller patients.
- 2 February 2013
- Published by Springer Nature in Pediatric Cardiology
- Vol. 34 (8) , 2068-2072
New Design of the Amplatzer Membranous VSD Occluder: A Step Forward?
Closure of perimembranous ventricular septal defects (PmVSDs) [4] with the original Amplatzer membranous VSD occluder (mVSD1) has been associated with an increased risk of complications, the most notable of which has been complete heart block. This has led to the introduction of a new device to close PmVSDs. The authors describe their experience with the new Amplatzer membranous VSD occluder (mVSD2) in two patients and critique the new device design and delivery system, comparing it with the mVSD1 occluder. Two patients underwent attempted closure of PmVSDs with the new mVSD2 device. One patient had successful closure of the defect with no residual shunt and no evidence of heart block at follow-up evaluation. Trace to mild aortic insufficiency was observed at the time of closure and at the last follow-up visit. The rhythm remained sinus. In the second patient, the device was placed but removed before release because of inability to orient the device in optimal position. Percutaneous closure of PmVSD is feasible with the new mVSD2 occluder. The change in the design may reduce the incidence of complete heart block. It remains to be seen whether the device will be suitable for smaller patients.
- 11 May 2012
- Published by Springer Nature in Pediatric Cardiology
- Vol. 33 (7) , 995-1000
Recent Changes in Instructions for Use for the Amplatzer Atrial Septal Defect Occluder: How to Incorporate These Changes While Using Transesophageal Echocardiography or Intracardiac Echocardiography?
The Amplatzer septal occluder is commonly used to close secundum atrial septal defects (ASDs). Recently, the manufacturer’s recommendations have been modified with regard to contraindications for its use. These changes primarily focus on evaluation of the aortic rim (anterio–superior rim) with transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE). In this editorial, we will review systematically all of the sequential views in TEE and ICE that are required for thorough assessment of the aortic rim and provide explanation of what constitutes deficiency of the aortic rim as seen on ICE.
- 11 May 2012
- Published by Springer Nature in Pediatric Cardiology
- Vol. 33 (7) , 995-1000
Recent Changes in Instructions for Use for the Amplatzer Atrial Septal Defect Occluder: How to Incorporate These Changes While Using Transesophageal Echocardiography or Intracardiac Echocardiography?
The Amplatzer septal occluder is commonly used to close secundum atrial septal defects (ASDs). Recently, the manufacturer’s recommendations have been modified with regard to contraindications for its use. These changes primarily focus on evaluation of the aortic rim (anterio–superior rim) with transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE). In this editorial, we will review systematically all of the sequential views in TEE and ICE that are required for thorough assessment of the aortic rim and provide explanation of what constitutes deficiency of the aortic rim as seen on ICE.
- 1 January 2012
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 79 (1) , 125-130
Variable approaches to arterial ductal stenting in infants with complex congenital heart disease
Stenting of the arterial duct to maintain postnatal communication between the pulmonary and systemic arterial circulations in infants with complex congenital heart disease is an acceptable alternative to a surgically created systemic to pulmonary artery shunt. The procedure, however, can be demanding given the variable anatomy of the patent ductus arteriosus. We report a series of cases of ductal stenting via a range of varying approaches in neonates with complex congenital heart disease, and display the variety of situations in which these approaches may be used. © 2011 Wiley Periodicals, Inc
- 1 January 2012
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 79 (1) , 125-130
Variable approaches to arterial ductal stenting in infants with complex congenital heart disease
Stenting of the arterial duct to maintain postnatal communication between the pulmonary and systemic arterial circulations in infants with complex congenital heart disease is an acceptable alternative to a surgically created systemic to pulmonary artery shunt. The procedure, however, can be demanding given the variable anatomy of the patent ductus arteriosus. We report a series of cases of ductal stenting via a range of varying approaches in neonates with complex congenital heart disease, and display the variety of situations in which these approaches may be used. © 2011 Wiley Periodicals, Inc
- Open Access
- 1 January 2010
- Published by Medknow in Annals of Pediatric Cardiology
- Vol. 3 (1) , 35-9
Patent foramen ovale closure
Ann Pediatr Card, Annals of Pediatric Cardiology is the official publication of The Pediatric Cardiology Society of India .
- 1 January 2010
- Published by Medknow in Annals of Pediatric Cardiology
- Vol. 3 (1) , 35-9
Open AccessPatent foramen ovale closure
Ann Pediatr Card, Annals of Pediatric Cardiology is the official publication of The Pediatric Cardiology Society of India .
- 10 June 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 72 (1) , 74-79
PFO closure complications from the AGA registry
Objectives: To evaluate all complications that occurred during or after cardiac catheterizations for Amplatzer PFO device closure of patent foramen ovale (PFO), determine the cause of the complications and recommend techniques to minimize complications in the future. Background: Rare complications were reported to the manufacturer of the Amplatzer PFO occluder since the introduction of the device. Methods: A panel of independent physicians reviewed all complications reported to the manufacturer to determine whether the complication was related to the device or related to the cardiac catheterization procedure. Demographic data, echocardiograms, operative reports, and time to occurrence of complications were reviewed. Results: A total of 11 events were reported. Only two patients had device related complications (erosion), an incidence of 0.018%. Two patients were found to have additional atrial septal defect after PFO closure. Two patients were thought to have an inflammatory reaction without any serious sequelae. Five complications were related to the cardiac catheterization procedure (atrial appendage perforation). Conclusions: Device related complications after Amplatzer PFO occluder placement are extremely rare. Cardiac catheterization related complications appear to be the most common cause of the hemodynamic compromise. Careful manipulation of catheters and wires, recognition of the location of the catheter by fluoroscopy and echocardiography will decrease the risk of such complications.
- 10 June 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 72 (1) , 74-79
PFO closure complications from the AGA registry
Objectives: To evaluate all complications that occurred during or after cardiac catheterizations for Amplatzer PFO device closure of patent foramen ovale (PFO), determine the cause of the complications and recommend techniques to minimize complications in the future. Background: Rare complications were reported to the manufacturer of the Amplatzer PFO occluder since the introduction of the device. Methods: A panel of independent physicians reviewed all complications reported to the manufacturer to determine whether the complication was related to the device or related to the cardiac catheterization procedure. Demographic data, echocardiograms, operative reports, and time to occurrence of complications were reviewed. Results: A total of 11 events were reported. Only two patients had device related complications (erosion), an incidence of 0.018%. Two patients were found to have additional atrial septal defect after PFO closure. Two patients were thought to have an inflammatory reaction without any serious sequelae. Five complications were related to the cardiac catheterization procedure (atrial appendage perforation). Conclusions: Device related complications after Amplatzer PFO occluder placement are extremely rare. Cardiac catheterization related complications appear to be the most common cause of the hemodynamic compromise. Careful manipulation of catheters and wires, recognition of the location of the catheter by fluoroscopy and echocardiography will decrease the risk of such complications.
- 10 June 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 72 (1) , 102-111
Closure of muscular ventricular septal defects: Transcatheter and hybrid techniques
- 10 June 2008
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 72 (1) , 102-111
Closure of muscular ventricular septal defects: Transcatheter and hybrid techniques