Stefano Muzzarelli
Stefano Muzzarelli has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Juerg Schwitter
Service of Cardiology Lausanne University Hospital (CHUV) and University of Lausanne (UNIL) Lausanne Switzerland
3 shared publications Alison Knauth Meadows
Department of Radiology, University Hospital of California, San Francisco, CA
2 shared publications- Anja Wagner
Comprehensive Cardiology of Stamford and Greenwich, Stamford, CT, USA
2 shared publications - Detlev Nothnagel
Department of Cardiology, Klinikum Ludwigsburg, Ludwigsburg, Germany
2 shared publications - Didier Locca
Department of Cardiology, Center of Cardiac Magnetic Resonance (CRMC), University Hospital Lausanne, Lausanne, Switzerland
2 shared publications - Heiko Mahrholdt
Department of Cardiology and Angiology, Robert Bosch Medical Center, Stuttgart, Germany
2 shared publications
Latest Publications
- 1 June 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (6) , 1138-1146
Predictors of disagreement between prospectively ECG-triggered dual-source coronary computed tomography angiography and conventional coronary angiography
- 1 June 2016
- Published by Elsevier in European Journal of Radiology
- Vol. 85 (6) , 1138-1146
Predictors of disagreement between prospectively ECG-triggered dual-source coronary computed tomography angiography and conventional coronary angiography
- 14 July 2013
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 15 (1) , 77-84
Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valve
Aims Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. Methods and results Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. Conclusion Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
- 14 July 2013
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 15 (1) , 77-84
Quantification of aortic flow by phase-contrast magnetic resonance in patients with bicuspid aortic valve
Aims Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. Methods and results Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. Conclusion Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.
- Open Access
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 55
Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteria
- 1 January 2013
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 15 (1) , 55
Open AccessQuality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteria
- 30 May 2012
- Vol. 8 (343) , 1177-83
[Cardiac magnetic resonance in acute myocarditis: a new non-invasive diagnostic gold standard?].
Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.
- 30 May 2012
- Vol. 8 (343) , 1177-83
[Cardiac magnetic resonance in acute myocarditis: a new non-invasive diagnostic gold standard?].
Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.
- 1 May 2012
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 27 (3) , 175-178
Collateral Flow Measurement by Phase-contrast Magnetic Resonance Imaging for the Assessment of Systemic Venous Baffle Patency After Atrial Switch Repair for Transposition of the Great Arteries
Purpose: We aimed to describe and compare azygos vein flow patterns of patients with obstructed and unobstructed systemic venous baffle after atrial switch repair for d-transposition of the great arteries (TGA). We hypothesized that phase-contrast magnetic resonance imaging would enable characterization of retrograde collateral flow across the azygos vein in cases of systemic venous baffle obstruction. Materials and Methods: This is a retrospective, cross-sectional study. Twelve patients with atrial switch repair for TGA were examined. Azygos flow index was measured with phase-contrast magnetic resonance imaging; comparison was made between patients with documented systemic venous baffle obstruction (n=3) and a control group of patients without baffle obstruction (n=9). Results: Patients with systemic venous baffle obstruction had a distinctive azygos flow pattern that was retrograde and an increased amount of azygos flow compared with patients without obstruction [median (range), −436 (−455/−399) vs. 103 (51/125) mL/min/m2; P=0.01]. Conclusions: Patients with systemic venous baffle obstruction have a characteristic collateral flow across the azygos vein. Azygos vein flow measurement may be used for the assessment of baffle patency in patients after atrial switch repair for TGA. However, diagnostic accuracy needs to be tested in a larger population.
- 1 May 2012
- Published by Wolters Kluwer Health in Journal of Thoracic Imaging
- Vol. 27 (3) , 175-178
Collateral Flow Measurement by Phase-contrast Magnetic Resonance Imaging for the Assessment of Systemic Venous Baffle Patency After Atrial Switch Repair for Transposition of the Great Arteries
Purpose: We aimed to describe and compare azygos vein flow patterns of patients with obstructed and unobstructed systemic venous baffle after atrial switch repair for d-transposition of the great arteries (TGA). We hypothesized that phase-contrast magnetic resonance imaging would enable characterization of retrograde collateral flow across the azygos vein in cases of systemic venous baffle obstruction. Materials and Methods: This is a retrospective, cross-sectional study. Twelve patients with atrial switch repair for TGA were examined. Azygos flow index was measured with phase-contrast magnetic resonance imaging; comparison was made between patients with documented systemic venous baffle obstruction (n=3) and a control group of patients without baffle obstruction (n=9). Results: Patients with systemic venous baffle obstruction had a distinctive azygos flow pattern that was retrograde and an increased amount of azygos flow compared with patients without obstruction [median (range), −436 (−455/−399) vs. 103 (51/125) mL/min/m2; P=0.01]. Conclusions: Patients with systemic venous baffle obstruction have a characteristic collateral flow across the azygos vein. Azygos vein flow measurement may be used for the assessment of baffle patency in patients after atrial switch repair for TGA. However, diagnostic accuracy needs to be tested in a larger population.
- 1 March 2012
- Published by Elsevier in The American Journal of Cardiology
- Vol. 109 (6) , 861-865
Usefulness of Cardiovascular Magnetic Resonance Imaging to Predict the Need for Intervention in Patients With Coarctation of the Aorta
- 1 March 2012
- Published by Elsevier in The American Journal of Cardiology
- Vol. 109 (6) , 861-865
Usefulness of Cardiovascular Magnetic Resonance Imaging to Predict the Need for Intervention in Patients With Coarctation of the Aorta
- Open Access
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 44-35
Cost evaluation of cardiovascular magnetic resonance versus coronary angiography for the diagnostic work-up of coronary artery disease: Application of the European Cardiovascular Magnetic Resonance registry data to the German, United Kingdom, Swiss, and United States health care systems
- 1 January 2012
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 14 (1) , 44-35
Open AccessCost evaluation of cardiovascular magnetic resonance versus coronary angiography for the diagnostic work-up of coronary artery disease: Application of the European Cardiovascular Magnetic Resonance registry data to the German, United Kingdom, Swiss, and United States health care systems