Sai K. Banala
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Sai K. Banala has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Sunil K. Agrawal.
University of Delaware
5 shared publications - Abhishek Agrawal
Mechanical Engineering Department, University of Delaware, Newark, Delaware 19716
1 shared publication - Alexander Kulpe
Graduate Student, Mechanical Systems Laboratory, Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, U.S.A.
1 shared publication - John Peter Scholz
University of Delaware
1 shared publication Sean McIntosh
University of Delaware, Newark, DE
1 shared publication- Stuart A. Binder-Macleod
Department of Physical Therapy, University of Delaware, DE 19716, United States
1 shared publication
Latest Publications
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457898,p. 401-407
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
This paper describes the design and human machine interface of an Active Leg EXoskeleton (ALEX) for gait rehabilitation of patients with walking disabilities. The paper proposes force-field controller which can apply suitable forces on the leg to help it move on a desired trajectory. The interaction forces between the subject and the orthosis are designed to be 'assist-as-needed' for safe and effective gait training. Simulations and experimental results with the force-field controller are presented. Experiments have been performed with healthy subjects walking on a treadmill. It was shown that a healthy subject could be retrained in about 45 minutes with ALEX to walk on a treadmill with a significantly altered gait. In the coming months, this powered orthosis will be used for gait training of stroke patients.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19457898,p. 401-407
Active Leg Exoskeleton (ALEX) for Gait Rehabilitation of Motor-Impaired Patients
This paper describes the design and human machine interface of an Active Leg EXoskeleton (ALEX) for gait rehabilitation of patients with walking disabilities. The paper proposes force-field controller which can apply suitable forces on the leg to help it move on a desired trajectory. The interaction forces between the subject and the orthosis are designed to be 'assist-as-needed' for safe and effective gait training. Simulations and experimental results with the force-field controller are presented. Experiments have been performed with healthy subjects walking on a treadmill. It was shown that a healthy subject could be retrained in about 45 minutes with ALEX to walk on a treadmill with a significantly altered gait. In the coming months, this powered orthosis will be used for gait training of stroke patients.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 4140-4145
A Powered Leg Orthosis for Gait Rehabilitation of Motor-Impaired Patients
This paper describes a powered leg orthosis for gait rehabilitation of patients with walking disabilities. The paper proposes controllers which can apply suitable forces on the leg so that it moves on a desired trajectory. The description of the controllers, simulations and experimental results with the powered orthosis are presented in the paper. Currently, experiments have been performed with a dummy leg in the orthosis. In the coming months, this powered orthosis will be used on healthy subjects and stroke patients.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 4140-4145
A Powered Leg Orthosis for Gait Rehabilitation of Motor-Impaired Patients
This paper describes a powered leg orthosis for gait rehabilitation of patients with walking disabilities. The paper proposes controllers which can apply suitable forces on the leg so that it moves on a desired trajectory. The description of the controllers, simulations and experimental results with the powered orthosis are presented in the paper. Currently, experiments have been performed with a dummy leg in the orthosis. In the coming months, this powered orthosis will be used on healthy subjects and stroke patients.
- 4 December 2006
- Published by Wiley in Journal of Mechanical Design
- Vol. 129 (11) , 1137-1143
Design of a Novel Two Degree-of-Freedom Ankle-Foot Orthosis
An ankle-foot orthosis (AFO) is commonly used to help subjects with weakness of ankle dorsiflexor muscles due to peripheral or central nervous system disorders. Both these disorders are due to the weakness of the tibialis anterior muscle, which results in the lack of dorsiflexion assist moment. The deformity and muscle, weakness of one joint in the lower extremity influences the stability of the adjacent joints, thereby requiring compensatory adaptations. We present an innovative ankle-foot orthosis (AFO). The prototype AFO would introduce greater functionality over currently marketed devices by means of its pronation-supination degree of freedom in addition to flexion/extension. This orthosis can be used to measure joint forces and moments applied by the human at both joints. In the future, by incorporation of actuators in the device, it will be used as a training device to restore a normal walking pattern.
- 4 December 2006
- Published by Wiley in Journal of Mechanical Design
- Vol. 129 (11) , 1137-1143
Design of a Novel Two Degree-of-Freedom Ankle-Foot Orthosis
An ankle-foot orthosis (AFO) is commonly used to help subjects with weakness of ankle dorsiflexor muscles due to peripheral or central nervous system disorders. Both these disorders are due to the weakness of the tibialis anterior muscle, which results in the lack of dorsiflexion assist moment. The deformity and muscle, weakness of one joint in the lower extremity influences the stability of the adjacent joints, thereby requiring compensatory adaptations. We present an innovative ankle-foot orthosis (AFO). The prototype AFO would introduce greater functionality over currently marketed devices by means of its pronation-supination degree of freedom in addition to flexion/extension. This orthosis can be used to measure joint forces and moments applied by the human at both joints. In the future, by incorporation of actuators in the device, it will be used as a training device to restore a normal walking pattern.
- 1 January 2005
- Published by ASME International
- p. 459-465
Gait Rehabilitation With an Active Leg Orthosis
In this paper, we discuss the design and control strategies for an active gait rehabilitation device for the lower extrmity. This device uses gravity balancing to reduce the net torque required by the actuators during motion. Two controllers are proposed in this paper. The first uses a robust controller and the second uses a torque assisting control law. Simulations of these controllers are presented in this paper. Experiments are currently being conducted with this orthosis on healthy and stroke subjects.
- 1 January 2005
- Published by ASME International
- p. 459-465
Gait Rehabilitation With an Active Leg Orthosis
In this paper, we discuss the design and control strategies for an active gait rehabilitation device for the lower extrmity. This device uses gravity balancing to reduce the net torque required by the actuators during motion. Two controllers are proposed in this paper. The first uses a robust controller and the second uses a torque assisting control law. Simulations of these controllers are presented in this paper. Experiments are currently being conducted with this orthosis on healthy and stroke subjects.
- 1 January 2004
- Published by ASME International
- p. 1055-1061
Design and Optimization of a Mechanism for Out of Plane Insect Wing Like Motion With Twist
A mechanism is presented that can generate insect wing like motion. This motion includes both flapping out of the stroke plane in addition to twist of the wing. The mechanism has a single degree-of-freedom and employs a five bar mechanism in addition to an auxiliary four bar mechanism. The parameters in the mechanism were optimized to generate a prescribed motion of the wing taken from a hawk moth kinematic flight data. A scaled model of the mechanism was fabricated to verify practical feasibility of the design. In future we will miniaturize this mechanism on our flying bird prototypes.
- 1 January 2004
- Published by ASME International
- p. 1055-1061
Design and Optimization of a Mechanism for Out of Plane Insect Wing Like Motion With Twist
A mechanism is presented that can generate insect wing like motion. This motion includes both flapping out of the stroke plane in addition to twist of the wing. The mechanism has a single degree-of-freedom and employs a five bar mechanism in addition to an auxiliary four bar mechanism. The parameters in the mechanism were optimized to generate a prescribed motion of the wing taken from a hawk moth kinematic flight data. A scaled model of the mechanism was fabricated to verify practical feasibility of the design. In future we will miniaturize this mechanism on our flying bird prototypes.