Eli Eikefjord
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eli Eikefjord has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Jarle Rørvik
Department of Radiology, Haukeland University Hospital, PO Box 1400, 5021 Bergen, Norway
2 shared publicationsArvid Lundervold
Department of Radiology, Haukeland University Hospital, PO Box 1400, 5021 Bergen, Norway
1 shared publicationEinar Svarstad
Department of Clinical Medicine, University of Bergen, Bergen, Norway
1 shared publicationErlend Hodneland
MedViz, Research Cluster, University of Bergen, Bergen, Norway
1 shared publicationErling Andersen
Department of Radiology, Haukeland University Hospital, PO Box 1400, 5021 Bergen, Norway
1 shared publication- Frits Thorsen
Department of Biomedicine, University of Bergen, Bergen, Norway
1 shared publication
Latest Publications
- 1 November 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (5) , 1022-1030
Quantification of Single-Kidney Function and Volume in Living Kidney Donors Using Dynamic Contrast-Enhanced MRI
OBJECTIVE. The objective of our study was to investigate whether dynamic contrast-enhanced MRI (DCE-MRI) can detect differences and potential adaption in single-kidney parenchymal volume, blood flow, glomerular filtration rate (GFR), and filtration fraction in the remaining kidney of healthy donors compared with nondonors. Further, we evaluated the agreement in donor GFRs measured using DCE-MRI versus serum clearance of iohexol. SUBJECTS AND METHODS. Twenty living kidney donors and 20 healthy control subjects underwent DCE-MRI and iohexol GFR. Renal parenchymal volume was assessed from maximum-signal-intensity maps. Single-kidney MRI measurements of blood flow and GFR were derived from parenchymal signal intensity–time curves fitted to a two-compartment filtration model. The Student t test, Pearson correlation coefficient, mean differences, and limits of agreement were applied to analyze MRI measurements between groups and agreement with iohexol GFR. RESULTS. MRI findings showed significantly higher blood...
- 1 November 2016
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 207 (5) , 1022-1030
Quantification of Single-Kidney Function and Volume in Living Kidney Donors Using Dynamic Contrast-Enhanced MRI
OBJECTIVE. The objective of our study was to investigate whether dynamic contrast-enhanced MRI (DCE-MRI) can detect differences and potential adaption in single-kidney parenchymal volume, blood flow, glomerular filtration rate (GFR), and filtration fraction in the remaining kidney of healthy donors compared with nondonors. Further, we evaluated the agreement in donor GFRs measured using DCE-MRI versus serum clearance of iohexol. SUBJECTS AND METHODS. Twenty living kidney donors and 20 healthy control subjects underwent DCE-MRI and iohexol GFR. Renal parenchymal volume was assessed from maximum-signal-intensity maps. Single-kidney MRI measurements of blood flow and GFR were derived from parenchymal signal intensity–time curves fitted to a two-compartment filtration model. The Student t test, Pearson correlation coefficient, mean differences, and limits of agreement were applied to analyze MRI measurements between groups and agreement with iohexol GFR. RESULTS. MRI findings showed significantly higher blood...
- 1 March 2008
- Published by SAGE Publications in Acta Radiologica
- Vol. 49 (2) , 222-229
Cost-effectiveness analysis (cea) of intravenous urography (ivu) and unenhanced multidetector computed tomography (mdct) for initial investigation of suspected acute ureterolithiasis
Background: It is important to compare the cost and effectiveness of multidetector computed tomography (MDCT) and intravenous urography (IVU) to determine the most cost-effective alternative for the initial investigation of acute ureterolithiasis. Purpose: To analyze the task-specific variable costs combined with the diagnostic effect of MDCT and IVU for patients with acute flank pain, and to determine which is most cost effective. Material and Methods: 119 patients with acute flank pain suggestive of stone disease (ureterolithiasis) were examined by both MDCT and IVU. Variable costs related to medical equipment, consumption material, equipment control, and personnel were calculated. The diagnostic effect was assessed. Results: The variable costs of MDCT versus IVU were EUR 32 and EUR 117, respectively. This significant difference was mainly due to savings in examination time, higher annual examination frequency, lower material costs, and no use of contrast media. As for diagnostic effect, MDCT proved considerably more accurate in the diagnosis of stone disease than IVU and markedly more accurate concerning differential diagnoses. Conclusion: MDCT had lower differential costs and a higher capacity to determine correctly stone disease and differential diagnoses, as compared to IVU, in patients with acute flank pain. Consequently, MDCT is a dominant alternative to IVU when evaluated exclusively from a cost-effective perspective.
- 1 March 2008
- Published by SAGE Publications in Acta Radiologica
- Vol. 49 (2) , 222-229
Cost-effectiveness analysis (cea) of intravenous urography (ivu) and unenhanced multidetector computed tomography (mdct) for initial investigation of suspected acute ureterolithiasis
Background: It is important to compare the cost and effectiveness of multidetector computed tomography (MDCT) and intravenous urography (IVU) to determine the most cost-effective alternative for the initial investigation of acute ureterolithiasis. Purpose: To analyze the task-specific variable costs combined with the diagnostic effect of MDCT and IVU for patients with acute flank pain, and to determine which is most cost effective. Material and Methods: 119 patients with acute flank pain suggestive of stone disease (ureterolithiasis) were examined by both MDCT and IVU. Variable costs related to medical equipment, consumption material, equipment control, and personnel were calculated. The diagnostic effect was assessed. Results: The variable costs of MDCT versus IVU were EUR 32 and EUR 117, respectively. This significant difference was mainly due to savings in examination time, higher annual examination frequency, lower material costs, and no use of contrast media. As for diagnostic effect, MDCT proved considerably more accurate in the diagnosis of stone disease than IVU and markedly more accurate concerning differential diagnoses. Conclusion: MDCT had lower differential costs and a higher capacity to determine correctly stone disease and differential diagnoses, as compared to IVU, in patients with acute flank pain. Consequently, MDCT is a dominant alternative to IVU when evaluated exclusively from a cost-effective perspective.
- 1 April 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 188 (4) , 934-939
Comparison of Effective Radiation Doses in Patients Undergoing Unenhanced MDCT and Excretory Urography for Acute Flank Pain
OBJECTIVE. The purpose of this study was to measure and compare the effective radiation dose in patients undergoing unenhanced MDCT and excretory urography for acute flank pain, and to explore technical and practical factors affecting the effective dose. SUBJECTS AND METHODS. One hundred nineteen patients with acute flank pain were included. All patients were examined using both MDCT and excretory urography. CT involved one acquisition from the upper kidney margin to the symphysis pubis. The only protocol variation was in the tube current (mAs), which was made according to patient body mass. The excretory urography protocol consisted of three images, with more when supplementary images were needed. Effective radiation doses were computer-simulated using dosimetry programs for CT and conventional radiography, based on Norwegian Radiological Protection Board dose data sets. Mean and SDs of measured patient doses were calculated and compared. Further analyses of dose variations in body mass categories (body mass index) were conducted, as were analyses concerning the number of images taken. RESULTS. The mean effective doses were 7.7 mSv with MDCT and 3.63 mSv with excretory urography. The effective dose varied both in and between techniques but could be predicted. Radiation risk decreased significantly with increased patient weight. CONCLUSION. The average effective dose with MDCT was more than double that with excretory urography. However, the appropriate dose could be strongly predicted by the patient's body mass index and by procedure. An optimum low-dose protocol should be considered before initiating unenhanced MDCT for ureteral colic in order to minimize the radiation-induced cancer risk and to secure adequate image quality.
- 1 April 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 188 (4) , 934-939
Comparison of Effective Radiation Doses in Patients Undergoing Unenhanced MDCT and Excretory Urography for Acute Flank Pain
OBJECTIVE. The purpose of this study was to measure and compare the effective radiation dose in patients undergoing unenhanced MDCT and excretory urography for acute flank pain, and to explore technical and practical factors affecting the effective dose. SUBJECTS AND METHODS. One hundred nineteen patients with acute flank pain were included. All patients were examined using both MDCT and excretory urography. CT involved one acquisition from the upper kidney margin to the symphysis pubis. The only protocol variation was in the tube current (mAs), which was made according to patient body mass. The excretory urography protocol consisted of three images, with more when supplementary images were needed. Effective radiation doses were computer-simulated using dosimetry programs for CT and conventional radiography, based on Norwegian Radiological Protection Board dose data sets. Mean and SDs of measured patient doses were calculated and compared. Further analyses of dose variations in body mass categories (body mass index) were conducted, as were analyses concerning the number of images taken. RESULTS. The mean effective doses were 7.7 mSv with MDCT and 3.63 mSv with excretory urography. The effective dose varied both in and between techniques but could be predicted. Radiation risk decreased significantly with increased patient weight. CONCLUSION. The average effective dose with MDCT was more than double that with excretory urography. However, the appropriate dose could be strongly predicted by the patient's body mass index and by procedure. An optimum low-dose protocol should be considered before initiating unenhanced MDCT for ureteral colic in order to minimize the radiation-induced cancer risk and to secure adequate image quality.