Sankar Arumugam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sankar Arumugam has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
Aitang Xing
Department of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, New South Wales, Australia; South Western Clinical School, University of New South Wales, Sydney, New South Wales, Australia
7 shared publications- Lois Holloway
South Western Sydney Clinical School, Faculty of Medicine, UNSW, Sydney, Australia
5 shared publications Lois Holloway
Department of Medical Physics, Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, New South Wales, Australia; South Western Clinical School, University of New South Wales, Sydney, New South Wales, Australia; Centre for Medical Radiation Physics, University of Wollongong, Wollongong, New South Wales, Australia; Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales, Australia
3 shared publicationsMark Sidhom
Department of Radiation Oncology, Liverpool and Macarthur Cancer Therapy Centres, New South Wales, Australia
2 shared publicationsTony Young
Liverpool and Macarthur Cancer Therapy Centres and Ingham Institute, Liverpool, New South Wales, Australia; Institute of Medical Physics, School of Physics, University of Sydney, Sydney, New South Wales, Australia
2 shared publicationsCesar Ochoa
Department of Radiation Oncology, Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW, 2170, Australia
1 shared publication
Latest Publications
- Open Access
- 24 May 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1-8
PROstate Multicentre External beam radioTHErapy Using a Stereotactic boost: the PROMETHEUS study protocol
High Dose Rate Brachytherapy (HDRB) boost is a well-established treatment for prostate cancer (PC). We describe the PROstate Multicentre External beam radioTHErapy Using Stereotactic boost (PROMETHEUS) study. Non-surgical stereotactic techniques are used to deliver similar doses to HDRB boost regimens with a dose escalation sub-study. Eligible patients have intermediate or high risk PC. PROMETHEUS explores the safety, efficacy and feasibility of multiple Australian centres cooperating in the delivery of Prostate Stereotactic Body Radiotherapy (SBRT) technology. A SBRT boost component Target Dose (TD) of 19Gy in two fractions is to be delivered, followed by a subsequent EBRT component of 46Gy in 23 fractions. Once accrual triggers have been met, SBRT doses can be escalated in 1 Gy increments to a maximum of 22Gy in two fractions. Patient safety will also be measured with the rate of both acute and late moderate to severe Gastro-Intestinal (GI) and Genito-Urinary (GU) Common Terminology Criteria for Adverse Events (CTCAE) toxicities as well as patient reported quality of life. Efficacy will be assessed via biochemical control after 3 years. PROMETHEUS aims to generate evidence for a non-surgical possible future alternative to HDRB boost regimens, and introduce advanced radiotherapy techniques across multiple Australian cancer centres. The study was retrospectively registered on the ANZCTR (Australian New Zealand Clinical Trials Registry) with trial ID: ACTRN12615000223538 .
- 24 May 2018
- Published by Springer Nature in BMC Cancer
- Vol. 18 (1) , 1-8
Open AccessPROstate Multicentre External beam radioTHErapy Using a Stereotactic boost: the PROMETHEUS study protocol
High Dose Rate Brachytherapy (HDRB) boost is a well-established treatment for prostate cancer (PC). We describe the PROstate Multicentre External beam radioTHErapy Using Stereotactic boost (PROMETHEUS) study. Non-surgical stereotactic techniques are used to deliver similar doses to HDRB boost regimens with a dose escalation sub-study. Eligible patients have intermediate or high risk PC. PROMETHEUS explores the safety, efficacy and feasibility of multiple Australian centres cooperating in the delivery of Prostate Stereotactic Body Radiotherapy (SBRT) technology. A SBRT boost component Target Dose (TD) of 19Gy in two fractions is to be delivered, followed by a subsequent EBRT component of 46Gy in 23 fractions. Once accrual triggers have been met, SBRT doses can be escalated in 1 Gy increments to a maximum of 22Gy in two fractions. Patient safety will also be measured with the rate of both acute and late moderate to severe Gastro-Intestinal (GI) and Genito-Urinary (GU) Common Terminology Criteria for Adverse Events (CTCAE) toxicities as well as patient reported quality of life. Efficacy will be assessed via biochemical control after 3 years. PROMETHEUS aims to generate evidence for a non-surgical possible future alternative to HDRB boost regimens, and introduce advanced radiotherapy techniques across multiple Australian cancer centres. The study was retrospectively registered on the ANZCTR (Australian New Zealand Clinical Trials Registry) with trial ID: ACTRN12615000223538 .
- 30 October 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40 (4) , 823-829
Investigating the impact of treatment delivery uncertainties on treatment effectiveness for lung SABR
To quantify the impact of treatment delivery uncertainties on lung stereotactic ablative body radiotherapy (SABR) plans for step-and-shoot intensity-modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT). Baseline ssIMRT and VMAT treatment plans were generated for a cohort of 18 lung SABR patients. Modified plans were generated for each baseline plan by systematically varying gantry and collimator angles between − 5 and + 5 degrees, as well as multi-leaf collimator (MLC) leaf position errors of magnitude between 1 and 5 mm in both directions (i.e. leaf banks shifted either in the same (Type 1) or opposite (Type 2) directions). Planning target volume (PTV), spinal cord and healthy lung dose-volume histogram (DVH) metrics were compared between the modified and baseline plans. Collimator and gantry angle uncertainties did not significantly impact any of the PTV DVH metrics considered. MLC shifts of 5 mm resulted in average V95% changes of \(-\,10\%\) (Type 1) and \(-\,33\%\) (Type 2) and average \(\text{V}_{100\%}\) changes of \(-\,17\%\) (Type 1) and \(-\,44\%\) (Type 2) for ssIMRT and VMAT plans. Comparatively, MLC shifts of − 2 mm resulted in average \(\text{V}_{95\%}\) changes of \(-\,1\%\) (Type 1) and \(-\,3.5\%\) (Type 2) and average \(\text{V}_{100\%}\) changes of \(-\,3\%\) (Type 1) and \(-\,12\%\) (Type 2) for ssIMRT and VMAT plans. ssIMRT gantry angle uncertainties impacted spinal cord DVH metrics the most, with increases in \(\text{D} 0.1 \text{cc}\) of \(9\%\) occurring for a 1 degree shift. Type 2 MLC modifications impacted all OAR DVH metrics substantially with differences in spinal cord \(\text{D}_{\text{max}}\) (ssIMRT) and healthy lung \(\text{V} 20 \text{Gy}\) (VMAT) exceeding \(40\%\) for 5 mm shifts. Uncertainties in MLC leaf positions affected target and OAR DVH metrics more than collimator or gantry angle uncertainties for lung SABR plans. Less patient-to-patient variation occurred from delivery uncertainties in VMAT than ssIMRT.- 30 October 2017
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 40 (4) , 823-829
Investigating the impact of treatment delivery uncertainties on treatment effectiveness for lung SABR
To quantify the impact of treatment delivery uncertainties on lung stereotactic ablative body radiotherapy (SABR) plans for step-and-shoot intensity-modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT). Baseline ssIMRT and VMAT treatment plans were generated for a cohort of 18 lung SABR patients. Modified plans were generated for each baseline plan by systematically varying gantry and collimator angles between − 5 and + 5 degrees, as well as multi-leaf collimator (MLC) leaf position errors of magnitude between 1 and 5 mm in both directions (i.e. leaf banks shifted either in the same (Type 1) or opposite (Type 2) directions). Planning target volume (PTV), spinal cord and healthy lung dose-volume histogram (DVH) metrics were compared between the modified and baseline plans. Collimator and gantry angle uncertainties did not significantly impact any of the PTV DVH metrics considered. MLC shifts of 5 mm resulted in average V95% changes of \(-\,10\%\) (Type 1) and \(-\,33\%\) (Type 2) and average \(\text{V}_{100\%}\) changes of \(-\,17\%\) (Type 1) and \(-\,44\%\) (Type 2) for ssIMRT and VMAT plans. Comparatively, MLC shifts of − 2 mm resulted in average \(\text{V}_{95\%}\) changes of \(-\,1\%\) (Type 1) and \(-\,3.5\%\) (Type 2) and average \(\text{V}_{100\%}\) changes of \(-\,3\%\) (Type 1) and \(-\,12\%\) (Type 2) for ssIMRT and VMAT plans. ssIMRT gantry angle uncertainties impacted spinal cord DVH metrics the most, with increases in \(\text{D} 0.1 \text{cc}\) of \(9\%\) occurring for a 1 degree shift. Type 2 MLC modifications impacted all OAR DVH metrics substantially with differences in spinal cord \(\text{D}_{\text{max}}\) (ssIMRT) and healthy lung \(\text{V} 20 \text{Gy}\) (VMAT) exceeding \(40\%\) for 5 mm shifts. Uncertainties in MLC leaf positions affected target and OAR DVH metrics more than collimator or gantry angle uncertainties for lung SABR plans. Less patient-to-patient variation occurred from delivery uncertainties in VMAT than ssIMRT.- 7 January 2017
- Published by Elsevier in Physica Medica
- Vol. 33, 170-178
Variable angle stereo imaging for rapid patient position correction in an in-house real-time position monitoring system
- 7 January 2017
- Published by Elsevier in Physica Medica
- Vol. 33, 170-178
Variable angle stereo imaging for rapid patient position correction in an in-house real-time position monitoring system
- Open Access
- 31 October 2016
- Published by ClinMed International Library in International Journal of Cancer and Clinical Research
- Vol. 3 (5)
Validation of Measurement Based Dose Volume Metrics for the Quality Assurance of VMAT Plans
Ten each of prostate and head and neck (H&N) VMAT plans were considered for this study. Three types of errors were introduced into the original plans: gantry angle independent and dependent MLC errors, and gantry angle dependent dose error. The percentage difference in PTV-D95 between TPS and 3DVH was compared for no-error and error introduced plans.
- 31 October 2016
- Published by ClinMed International Library in International Journal of Cancer and Clinical Research
- Vol. 3 (5)
Open AccessValidation of Measurement Based Dose Volume Metrics for the Quality Assurance of VMAT Plans
Ten each of prostate and head and neck (H&N) VMAT plans were considered for this study. Three types of errors were introduced into the original plans: gantry angle independent and dependent MLC errors, and gantry angle dependent dose error. The percentage difference in PTV-D95 between TPS and 3DVH was compared for no-error and error introduced plans.
- 1 October 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (10) , 1238-1244
Comparison of three commercial dosimetric systems in detecting clinically significant VMAT delivery errors
- 1 October 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (10) , 1238-1244
Comparison of three commercial dosimetric systems in detecting clinically significant VMAT delivery errors
- 28 January 2016
- Published by Wiley in Medical Physics
- Vol. 43 (2) , 961-974
An online x‐ray based position validation system for prostate hypofractionated radiotherapy
Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in‐house software tool to verify target position with an Elekta‐Synergy linear accelerator using kV planar images acquired during treatment delivery.Methods: In‐house software, SeedTracker, was developed in matlab to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co‐ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPRseg) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPRtrig) were studied. Two‐dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system.Results: SeedTracker showed a TPRseg of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPRtrig of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPRtrig of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and 310°–350° (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images.Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20° arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT.
- 28 January 2016
- Published by Wiley in Medical Physics
- Vol. 43 (2) , 961-974
An online x‐ray based position validation system for prostate hypofractionated radiotherapy
Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in‐house software tool to verify target position with an Elekta‐Synergy linear accelerator using kV planar images acquired during treatment delivery.Methods: In‐house software, SeedTracker, was developed in matlab to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co‐ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPRseg) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPRtrig) were studied. Two‐dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system.Results: SeedTracker showed a TPRseg of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80°–100° and 260°–280° where seeds are obscured by anatomy. This resulted in a TPRtrig of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior–posterior and lateral directions, the TPRtrig of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130°–170° and 310°–350° (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images.Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20° arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT.
- 1 December 2015
- Published by Elsevier in Physica Medica
- Vol. 31 (8) , 1043-1054
Sensitivity of a helical diode array dosimeter to Volumetric Modulated Arc Therapy delivery errors
- 1 December 2015
- Published by Elsevier in Physica Medica
- Vol. 31 (8) , 1043-1054
Sensitivity of a helical diode array dosimeter to Volumetric Modulated Arc Therapy delivery errors
- 1 December 2013
- Published by Elsevier in Medical Dosimetry
- Vol. 38 (4) , 376-384
Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine
- 1 December 2013
- Published by Elsevier in Medical Dosimetry
- Vol. 38 (4) , 376-384
Independent calculation-based verification of IMRT plans using a 3D dose-calculation engine
- 20 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (7) , 071724
An algorithm to calculate a collapsed arc dose matrix in volumetric modulated arc therapy
Purpose:: The delivery of volumetric modulated arc therapy (VMAT) is more complex than other conformal radiotherapy techniques. In this work, the authors present the feasibility of performing routine verification of VMAT delivery using a dose matrix measured by a gantry mounted 2D ion chamber array and corresponding dose matrix calculated by an inhouse developed algorithm.Methods:: Pinnacle, v9.0, treatment planning system (TPS) was used in this study to generate VMAT plans for a 6 MV photon beam from an Elekta‐Synergy linear accelerator. An algorithm was developed and implemented with inhouse computer code to calculate the dose matrix resulting from a VMAT arc in a plane perpendicular to the beam at isocenter. The algorithm was validated using measurement of standard patterns and clinical VMAT plans with a 2D ion chamber array. The clinical VMAT plans were also validated using ArcCHECK measurements. The measured and calculated dose matrices were compared using gamma (γ) analysis with 3%/3 mm criteria and γ tolerance of 1.Results:: The dose matrix comparison of standard patterns has shown excellent agreement with the meanγ pass rate 97.7 (σ = 0.4)%. The validation of clinical VMAT plans using the dose matrix predicted by the algorithm and the corresponding measured dose matrices also showed good agreement with the mean γ pass rate of 97.6 (σ = 1.6)%. The validation of clinical VMAT plans using ArcCHECK measurements showed a mean pass rate of 95.6 (σ = 1.8)%.Conclusions:: The developed algorithm was shown to accurately predict the dose matrix, in a plane perpendicular to the beam, by considering all possible leaf trajectories in a VMAT delivery. This enables the verification of VMAT delivery using a 2D array detector mounted on a treatment head.
- 20 June 2013
- Published by Wiley in Medical Physics
- Vol. 40 (7) , 071724
An algorithm to calculate a collapsed arc dose matrix in volumetric modulated arc therapy
Purpose:: The delivery of volumetric modulated arc therapy (VMAT) is more complex than other conformal radiotherapy techniques. In this work, the authors present the feasibility of performing routine verification of VMAT delivery using a dose matrix measured by a gantry mounted 2D ion chamber array and corresponding dose matrix calculated by an inhouse developed algorithm.Methods:: Pinnacle, v9.0, treatment planning system (TPS) was used in this study to generate VMAT plans for a 6 MV photon beam from an Elekta‐Synergy linear accelerator. An algorithm was developed and implemented with inhouse computer code to calculate the dose matrix resulting from a VMAT arc in a plane perpendicular to the beam at isocenter. The algorithm was validated using measurement of standard patterns and clinical VMAT plans with a 2D ion chamber array. The clinical VMAT plans were also validated using ArcCHECK measurements. The measured and calculated dose matrices were compared using gamma (γ) analysis with 3%/3 mm criteria and γ tolerance of 1.Results:: The dose matrix comparison of standard patterns has shown excellent agreement with the meanγ pass rate 97.7 (σ = 0.4)%. The validation of clinical VMAT plans using the dose matrix predicted by the algorithm and the corresponding measured dose matrices also showed good agreement with the mean γ pass rate of 97.6 (σ = 1.6)%. The validation of clinical VMAT plans using ArcCHECK measurements showed a mean pass rate of 95.6 (σ = 1.8)%.Conclusions:: The developed algorithm was shown to accurately predict the dose matrix, in a plane perpendicular to the beam, by considering all possible leaf trajectories in a VMAT delivery. This enables the verification of VMAT delivery using a 2D array detector mounted on a treatment head.
- 8 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 031701
An accuracy assessment of different rigid body image registration methods and robotic couch positional corrections using a novel phantom
Purpose:: Image guided radiotherapy (IGRT) using cone beam computed tomography (CBCT) images greatly reduces interfractional patient positional uncertainties. An understanding of uncertainties in the IGRT process itself is essential to ensure appropriate use of this technology. The purpose of this study was to develop a phantom capable of assessing the accuracy of IGRT hardware and software including a 6 degrees of freedom patient positioning system and to investigate the accuracy of the Elekta XVI system in combination with the HexaPOD robotic treatment couch top.Methods:: The constructed phantom enabled verification of the three automatic rigid body registrations (gray value, bone, seed) available in the Elekta XVI software and includes an adjustable mount that introduces known rotational offsets to the phantom from its reference position. Repeated positioning of the phantom was undertaken to assess phantom rotational accuracy. Using this phantom the accuracy of the XVI registration algorithms was assessed considering CBCT hardware factors and image resolution together with the residual error in the overall image guidance process when positional corrections were performed through the HexaPOD couch system.Results:: The phantom positioning was found to be within 0.04 (σ = 0.12)°, 0.02 (σ = 0.13)°, and −0.03 (σ = 0.06)° in X, Y, and Z directions, respectively, enabling assessment of IGRT with a 6 degrees of freedom patient positioning system. The gray value registration algorithm showed the least error in calculated offsets with maximum mean difference of −0.2(σ = 0.4) mm in translational and −0.1(σ = 0.1)° in rotational directions for all image resolutions. Bone and seed registration were found to be sensitive to CBCT image resolution. Seed registration was found to be most sensitive demonstrating a maximum mean error of −0.3(σ = 0.9) mm and −1.4(σ = 1.7)° in translational and rotational directions over low resolution images, and this is reduced to −0.1(σ = 0.2) mm and −0.1(σ = 0.79)° using high resolution images.Conclusions:: The phantom, capable of rotating independently about three orthogonal axes was successfully used to assess the accuracy of an IGRT system considering 6 degrees of freedom. The overall residual error in the image guidance process of XVI in combination with the HexaPOD couch was demonstrated to be less than 0.3 mm and 0.3° in translational and rotational directions when using the gray value registration with high resolution CBCT images. However, the residual error, especially in rotational directions, may increase when the seed registration is used with low resolution images.
- 8 February 2013
- Published by Wiley in Medical Physics
- Vol. 40 (3) , 031701
An accuracy assessment of different rigid body image registration methods and robotic couch positional corrections using a novel phantom
Purpose:: Image guided radiotherapy (IGRT) using cone beam computed tomography (CBCT) images greatly reduces interfractional patient positional uncertainties. An understanding of uncertainties in the IGRT process itself is essential to ensure appropriate use of this technology. The purpose of this study was to develop a phantom capable of assessing the accuracy of IGRT hardware and software including a 6 degrees of freedom patient positioning system and to investigate the accuracy of the Elekta XVI system in combination with the HexaPOD robotic treatment couch top.Methods:: The constructed phantom enabled verification of the three automatic rigid body registrations (gray value, bone, seed) available in the Elekta XVI software and includes an adjustable mount that introduces known rotational offsets to the phantom from its reference position. Repeated positioning of the phantom was undertaken to assess phantom rotational accuracy. Using this phantom the accuracy of the XVI registration algorithms was assessed considering CBCT hardware factors and image resolution together with the residual error in the overall image guidance process when positional corrections were performed through the HexaPOD couch system.Results:: The phantom positioning was found to be within 0.04 (σ = 0.12)°, 0.02 (σ = 0.13)°, and −0.03 (σ = 0.06)° in X, Y, and Z directions, respectively, enabling assessment of IGRT with a 6 degrees of freedom patient positioning system. The gray value registration algorithm showed the least error in calculated offsets with maximum mean difference of −0.2(σ = 0.4) mm in translational and −0.1(σ = 0.1)° in rotational directions for all image resolutions. Bone and seed registration were found to be sensitive to CBCT image resolution. Seed registration was found to be most sensitive demonstrating a maximum mean error of −0.3(σ = 0.9) mm and −1.4(σ = 1.7)° in translational and rotational directions over low resolution images, and this is reduced to −0.1(σ = 0.2) mm and −0.1(σ = 0.79)° using high resolution images.Conclusions:: The phantom, capable of rotating independently about three orthogonal axes was successfully used to assess the accuracy of an IGRT system considering 6 degrees of freedom. The overall residual error in the image guidance process of XVI in combination with the HexaPOD couch was demonstrated to be less than 0.3 mm and 0.3° in translational and rotational directions when using the gray value registration with high resolution CBCT images. However, the residual error, especially in rotational directions, may increase when the seed registration is used with low resolution images.