Charles J. Coté
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Charles J. Coté has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Melissa Wheeler
Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
5 shared publications - Santhanam Suresh
Department of Pediatric Anesthesiology, Ann & Robert H. Lurie Children's Hospital of Chicago, Feinberg School of Medicine, Northwestern University, 225 East Chicago Avenue, Box 19, Chicago, IL 60611, USA
4 shared publications Andrew G. Roth
2 shared publicationsArti S. Patel
2 shared publicationsHelen W. Karl
2 shared publicationsSteven C. Hall
2 shared publications
Latest Publications
- 1 February 2004
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 100 (2) , 207-208
Discharge Criteria for Children Sedated by Nonanesthesiologists: Is “Safe” Really Safe Enough?
- 1 February 2004
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 100 (2) , 207-208
Discharge Criteria for Children Sedated by Nonanesthesiologists: Is “Safe” Really Safe Enough?
- 1 January 2004
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 51 (1) , 6-12
Obstructive sleep apnea and tonsillectomy: do we have a new indication for extended postoperative observation?
- 1 January 2004
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 51 (1) , 6-12
Obstructive sleep apnea and tonsillectomy: do we have a new indication for extended postoperative observation?
- 1 February 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (2) , 387-391
Traditional Versus New Needle Retractable IV Catheters in Children: Are They Really Safer, and Whom Are They Protecting?
Retractable needle IV catheters are designed to reduce needle-stick injuries; their use is mandated by federal regulations. We undertook a prospective data collection with the "traditional" IV catheters (JELCO) versus the "new" (Angiocath Autoguard). Assignment of catheter type was randomized by week. Data collected included assessment of the difficulty of i.v. access; number of catheters used; and splatters or spills of blood on skin, linen, floor, clothing, and operating room table. There were 473 attempted insertions in 330 patients over 20 days. No needle-stick injuries occurred. Seventy-seven blood spills or splatters occurred in 42 patients. The number of splatters or spills was four times more with the new compared with the traditional catheters. There were significantly more total splatters or spills and patients who experienced splatters or spills with new catheters when they were placed by attendings but not when placed by trainees. Our study suggests that use of this technology by more experienced anesthesiologists may increase the risk of exposure of health care providers to blood-borne pathogens. Practitioners should choose the i.v. system that allows the most efficient venous access with the least potential for blood contamination. Hospitals should allow the choice to be made by the individuals using the devices.
- 1 February 2003
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 96 (2) , 387-391
Traditional Versus New Needle Retractable IV Catheters in Children: Are They Really Safer, and Whom Are They Protecting?
Retractable needle IV catheters are designed to reduce needle-stick injuries; their use is mandated by federal regulations. We undertook a prospective data collection with the "traditional" IV catheters (JELCO) versus the "new" (Angiocath Autoguard). Assignment of catheter type was randomized by week. Data collected included assessment of the difficulty of i.v. access; number of catheters used; and splatters or spills of blood on skin, linen, floor, clothing, and operating room table. There were 473 attempted insertions in 330 patients over 20 days. No needle-stick injuries occurred. Seventy-seven blood spills or splatters occurred in 42 patients. The number of splatters or spills was four times more with the new compared with the traditional catheters. There were significantly more total splatters or spills and patients who experienced splatters or spills with new catheters when they were placed by attendings but not when placed by trainees. Our study suggests that use of this technology by more experienced anesthesiologists may increase the risk of exposure of health care providers to blood-borne pathogens. Practitioners should choose the i.v. system that allows the most efficient venous access with the least potential for blood contamination. Hospitals should allow the choice to be made by the individuals using the devices.
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1280
Comparison of Four Pulse Oximeters on Pediatric Patients during Anesthesia and the Initial Phases of Recovery: Does the New Generation Offer an Advantage?
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1280
Comparison of Four Pulse Oximeters on Pediatric Patients during Anesthesia and the Initial Phases of Recovery: Does the New Generation Offer an Advantage?
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1215
Parent/Nurse Controlled Epidural Analgesia in Children: Can They Do It?
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1215
Parent/Nurse Controlled Epidural Analgesia in Children: Can They Do It?
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1207
A Pharmacokinetic Study of a Needle-Free Transdermal Patient-Controlled Analgesia (PCA) System in Pediatric Patients
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1207
A Pharmacokinetic Study of a Needle-Free Transdermal Patient-Controlled Analgesia (PCA) System in Pediatric Patients
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1206
Persistent Frontal Headaches in Children, Adolescents, and Young Adults: Is There a Role for Serial Supraorbital and Supratrochlear Nerve Blocks?
- 1 September 2002
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 96 (Sup 2) , A1206
Persistent Frontal Headaches in Children, Adolescents, and Young Adults: Is There a Role for Serial Supraorbital and Supratrochlear Nerve Blocks?
- 1 June 2002
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 49 (S1) , R41-R44
Sedation disasters in pediatrics and concerns for office based practice
- 1 June 2002
- Published by Springer Nature in Canadian Journal of Anesthesia/Journal canadien d'anesthésie
- Vol. 49 (S1) , R41-R44
Sedation disasters in pediatrics and concerns for office based practice
- 1 January 2002
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 94 (1) , 37-43
A Comparison of Three Doses of a Commercially Prepared Oral Midazolam Syrup in Children
Midazolam is widely used as a preanesthetic medication for children. Prior studies have used extemporaneous formulations to disguise the bitter taste of IV midazolam and to improve patient acceptance, but with unknown bioavailability. In this prospective, randomized, double-blinded study we examined the efficacy, safety, and taste acceptability of three doses (0.25, 0.5, and 1.0 mg/kg, up to a maximum of 20 mg) of commercially prepared Versed((R)) syrup (midazolam HCl) in children stratified by age (6 mo to <2 yr, 2 to <6 yr, and 6 to <16 yr). All children were ASA class I-III scheduled for elective surgery. Subjects were continuously observed and monitored with pulse oximetry. Ninety-five percent of patients accepted the syrup, and 97% demonstrated satisfactory sedation before induction. There was an apparent relationship between dose and onset of sedation and anxiolysis (P < 0.01). Eight-eight percent had satisfactory anxiety ratings at the time of attempted separation from parents, and 86% had satisfactory anxiety ratings at face mask application. The youngest age group recovered earlier than the two older age groups (P < 0.001). There was no relationship between midazolam dose and duration of postanesthesia care unit stay. Before induction, there were no episodes of desaturation, but there were two episodes of nausea and three episodes of emesis. At the time of induction, during anesthesia, and in the postanesthesia care unit, there were several adverse respiratory events. Oral midazolam syrup is effective for producing sedation and anxiolysis at a dose of 0.25 mg/kg, with minimal effects on respiration and oxygen saturation even when administered at doses as large as 1.0 mg/kg (maximum, 20 mg) as the sole sedating medication to healthy children in a supervised clinical setting. Commercially prepared oral midazolam syrup is effective in producing sedation and anxiolysis in doses as small as 0.25 mg/kg; there is a slightly faster onset with increasing the dose to 1.0 mg/kg. At all doses, 97% of patients demonstrated satisfactory sedation, whereas 86% demonstrated satisfactory anxiolysis when the face mask was applied.
- 1 January 2002
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 94 (1) , 37-43
A Comparison of Three Doses of a Commercially Prepared Oral Midazolam Syrup in Children
Midazolam is widely used as a preanesthetic medication for children. Prior studies have used extemporaneous formulations to disguise the bitter taste of IV midazolam and to improve patient acceptance, but with unknown bioavailability. In this prospective, randomized, double-blinded study we examined the efficacy, safety, and taste acceptability of three doses (0.25, 0.5, and 1.0 mg/kg, up to a maximum of 20 mg) of commercially prepared Versed((R)) syrup (midazolam HCl) in children stratified by age (6 mo to <2 yr, 2 to <6 yr, and 6 to <16 yr). All children were ASA class I-III scheduled for elective surgery. Subjects were continuously observed and monitored with pulse oximetry. Ninety-five percent of patients accepted the syrup, and 97% demonstrated satisfactory sedation before induction. There was an apparent relationship between dose and onset of sedation and anxiolysis (P < 0.01). Eight-eight percent had satisfactory anxiety ratings at the time of attempted separation from parents, and 86% had satisfactory anxiety ratings at face mask application. The youngest age group recovered earlier than the two older age groups (P < 0.001). There was no relationship between midazolam dose and duration of postanesthesia care unit stay. Before induction, there were no episodes of desaturation, but there were two episodes of nausea and three episodes of emesis. At the time of induction, during anesthesia, and in the postanesthesia care unit, there were several adverse respiratory events. Oral midazolam syrup is effective for producing sedation and anxiolysis at a dose of 0.25 mg/kg, with minimal effects on respiration and oxygen saturation even when administered at doses as large as 1.0 mg/kg (maximum, 20 mg) as the sole sedating medication to healthy children in a supervised clinical setting. Commercially prepared oral midazolam syrup is effective in producing sedation and anxiolysis in doses as small as 0.25 mg/kg; there is a slightly faster onset with increasing the dose to 1.0 mg/kg. At all doses, 97% of patients demonstrated satisfactory sedation, whereas 86% demonstrated satisfactory anxiolysis when the face mask was applied.