Litong Jin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Litong Jin has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Wen Zhang
Department of Chemistry, East China Normal University, Shanghai 200062, China
4 shared publications- Guoyue Shi
East China Normal University
3 shared publications Hui Li
East China Normal University
3 shared publicationsYuezhong Xian
East China Normal University
3 shared publicationsChun Xu
Department of Chemistry, East China Normal University, Shanghai, China
2 shared publicationsHiroki Haraguchi
Department of Applied Chemistry, School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya, Japan
2 shared publications
Latest Publications
- 15 July 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 45, 292-299
Visible-light-activated photoelectrochemical biosensor for the study of acetylcholinesterase inhibition induced by endogenous neurotoxins
- 15 July 2013
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 45, 292-299
Visible-light-activated photoelectrochemical biosensor for the study of acetylcholinesterase inhibition induced by endogenous neurotoxins
- 15 June 2012
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 92 (7) , 832-843
FDU-15-Pt composites with different Pt loading and their electrocatalytic reduction to ultratrace nitroaromatic compounds
FDU-15 is a hexagonal mesoporous material with nanometer-sized, highly ordered arrays and large special surface area. In this work, FDU-15-Pt with 2.0%, 5.0% and 8.0% Pt loading were synthesised and used for electrochemical detection of trace nitroaromatic compounds (NACs). The FDU-15-Pt samples were characterised by CO Chemisorption, transmission electron microscopy (TEM) and X-ray diffraction (XRD). It has been demonstrated that FDU-15-Pt with 2.0% Pt loading has the smallest Pt particle size of 2.9 nm, highest Pt metal dispersion of 37.7% and largest Pt metal surface area of 21.36 m2 g−1. The FDU-15-Pt/PDDA modified electrode were assembled by electrostatic adsorption of Poly (diallyldimethylammonium chloride) (PDDA) and FDU-15-Pt. The 2.0% FDU-15-Pt modified sensor showed higher selectivity for NACs than those of 5.0% and 8.0% FDU-15-Pt, which were verified by electrochemical experiments. A linear response over TNT concentration ranging from 8.8 × 10−9 M to 1.2 × 10−5 M was exhibited with a low detection limit of 2.9 × 10−9 M (S/N = 3). Moreover, the proposed 2.0% FDU-15-Pt/PDDA modified sensor has been applied to the detection of NACs in spiked environmental water samples and shows promise for fast and accurate determination of trace NACs in real samples.
- 15 June 2012
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 92 (7) , 832-843
FDU-15-Pt composites with different Pt loading and their electrocatalytic reduction to ultratrace nitroaromatic compounds
FDU-15 is a hexagonal mesoporous material with nanometer-sized, highly ordered arrays and large special surface area. In this work, FDU-15-Pt with 2.0%, 5.0% and 8.0% Pt loading were synthesised and used for electrochemical detection of trace nitroaromatic compounds (NACs). The FDU-15-Pt samples were characterised by CO Chemisorption, transmission electron microscopy (TEM) and X-ray diffraction (XRD). It has been demonstrated that FDU-15-Pt with 2.0% Pt loading has the smallest Pt particle size of 2.9 nm, highest Pt metal dispersion of 37.7% and largest Pt metal surface area of 21.36 m2 g−1. The FDU-15-Pt/PDDA modified electrode were assembled by electrostatic adsorption of Poly (diallyldimethylammonium chloride) (PDDA) and FDU-15-Pt. The 2.0% FDU-15-Pt modified sensor showed higher selectivity for NACs than those of 5.0% and 8.0% FDU-15-Pt, which were verified by electrochemical experiments. A linear response over TNT concentration ranging from 8.8 × 10−9 M to 1.2 × 10−5 M was exhibited with a low detection limit of 2.9 × 10−9 M (S/N = 3). Moreover, the proposed 2.0% FDU-15-Pt/PDDA modified sensor has been applied to the detection of NACs in spiked environmental water samples and shows promise for fast and accurate determination of trace NACs in real samples.
- 1 December 2010
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 28 (12) , 2489-2493
Glucose Biosensor Based on the Fabrication of Glucose Oxidase in the Bio-Inspired Polydopamine-Gold Nanoparticle Composite Film
- 1 December 2010
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 28 (12) , 2489-2493
Glucose Biosensor Based on the Fabrication of Glucose Oxidase in the Bio-Inspired Polydopamine-Gold Nanoparticle Composite Film
- 14 May 2008
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 131 (2) , 432-438
Trace detection of nitroaromatic compounds with layer-by-layer assembled {SBA/PSS}n/PDDA modified electrode
- 14 May 2008
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 131 (2) , 432-438
Trace detection of nitroaromatic compounds with layer-by-layer assembled {SBA/PSS}n/PDDA modified electrode
- 1 October 2002
- Published by Springer Nature in Chromatographia
- Vol. 56 (7-8) , 449-453
Simultaneous determination of oxalate, thiosulfate, and thiocyanate in urine by ion-exclusion chromatography with electrochemical detection
- 1 October 2002
- Published by Springer Nature in Chromatographia
- Vol. 56 (7-8) , 449-453
Simultaneous determination of oxalate, thiosulfate, and thiocyanate in urine by ion-exclusion chromatography with electrochemical detection
- 26 August 2002
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 20 (8) , 771-776
Application of Nafion/ Cobalt Hexacyanoferrate Chemically Modified Electrodes for the Determination of Electroinactive Cations by Ion Chromatography
An amperometric detector based on the chemical modification of Nafion and cobalt (II) hexacyanoferrate (II, III) thin film (Nafion/Co‐CN‐Fe) onto a glassy carbon (GC) electrode was firstly developed for the determination of electroinactive cations (Li+, Na+, K+, Rb+, Cs+ and NH4+) in single column ion chromatography. A set of well‐defined peaks of electroinactive cation was obtained. The relative standard deviations (RSDs) of chromatographic peak height (nA) for these cations were all below 3.8%. The cations were detected conveniently in the linear concentration range of 6.0 × 10−6‐5.0 × 10−3 mol/L and their correlation coefficients were all above 0.99. The detection limits of the cations were 9.2 × 10−6 mol/L for Li+, 3.4 × 10−6 mol/L for Na+, 6.3 × 10−7 mol/L for K+, 7.8 × 10−7 mol/L for Rb+, 6.2 × 10−7 mol/L for Cs+ and 6.2 × 10−6 mol/L for NH4+, at a signal‐noise ratio of 3. The method was quick, sensitive, simple and was successfully applied to the analysis of rainwater samples. The electrode was stable for a 2 week period of operation with no evidence of chemical or mechanical deterioration.
- 26 August 2002
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 20 (8) , 771-776
Application of Nafion/ Cobalt Hexacyanoferrate Chemically Modified Electrodes for the Determination of Electroinactive Cations by Ion Chromatography
An amperometric detector based on the chemical modification of Nafion and cobalt (II) hexacyanoferrate (II, III) thin film (Nafion/Co‐CN‐Fe) onto a glassy carbon (GC) electrode was firstly developed for the determination of electroinactive cations (Li+, Na+, K+, Rb+, Cs+ and NH4+) in single column ion chromatography. A set of well‐defined peaks of electroinactive cation was obtained. The relative standard deviations (RSDs) of chromatographic peak height (nA) for these cations were all below 3.8%. The cations were detected conveniently in the linear concentration range of 6.0 × 10−6‐5.0 × 10−3 mol/L and their correlation coefficients were all above 0.99. The detection limits of the cations were 9.2 × 10−6 mol/L for Li+, 3.4 × 10−6 mol/L for Na+, 6.3 × 10−7 mol/L for K+, 7.8 × 10−7 mol/L for Rb+, 6.2 × 10−7 mol/L for Cs+ and 6.2 × 10−6 mol/L for NH4+, at a signal‐noise ratio of 3. The method was quick, sensitive, simple and was successfully applied to the analysis of rainwater samples. The electrode was stable for a 2 week period of operation with no evidence of chemical or mechanical deterioration.
- 21 March 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (4) , 485-489
Determination of drug–protein interactions by microdialysis coupled with liquid chromatography and electrochemical detection based on a nickel hexacyanoferrate modified electrode
Microdialysis sampling coupled with liquid chromatography–electrochemical detection (LC-ED) was developed and applied to determine the interaction of thiopurine (TP) with bovine serum albumin (BSA). A nickel hexacyanoferrate (NiHCNFe) modified electrode was fabricated and used as the working electrode in LC-ED for the determination of TP. Cyclic voltammetric experiments demonstrate that this chemically modified electrode (CME) can effectively catalyze the electrooxidation of TP. The mechanism of the catalytic oxidation of TP at the CME involves an ‘EC’ process. In the LC-ED, the CME also shows good stability and reproducibility for the determination of TP. The limit of detection is 5.0 × 10−7 mol l−1 for 6-TP with a signal-to-noise ratio of 3. The utility of microdialysis as a quantitative sampling technique for in vitro studies of drug–protein interactions was studied. The microdialysis experiments were performed in phosphate buffer solution (pH 7.4) containing different molar ratios of the drug and protein at 37 °C. The collected microdialysis sample with unbound TP was analyzed at the NiHCNFe CME in the LC-ED. The relative recovery of TP determined in vitro is 18.3% at a perfusion rate of 1.0 μl min−1 and the RSD is about 2.1%. The association constant and the number of binding sites on a BSA molecule calculated with the Scatchard equation are 3.72 × 10−3 (l mol−1) and 1.51, respectively. This method provides a fast, sensitive and simple technique for the study of drug–protein interactions.
- 21 March 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (4) , 485-489
Determination of drug–protein interactions by microdialysis coupled with liquid chromatography and electrochemical detection based on a nickel hexacyanoferrate modified electrode
Microdialysis sampling coupled with liquid chromatography–electrochemical detection (LC-ED) was developed and applied to determine the interaction of thiopurine (TP) with bovine serum albumin (BSA). A nickel hexacyanoferrate (NiHCNFe) modified electrode was fabricated and used as the working electrode in LC-ED for the determination of TP. Cyclic voltammetric experiments demonstrate that this chemically modified electrode (CME) can effectively catalyze the electrooxidation of TP. The mechanism of the catalytic oxidation of TP at the CME involves an ‘EC’ process. In the LC-ED, the CME also shows good stability and reproducibility for the determination of TP. The limit of detection is 5.0 × 10−7 mol l−1 for 6-TP with a signal-to-noise ratio of 3. The utility of microdialysis as a quantitative sampling technique for in vitro studies of drug–protein interactions was studied. The microdialysis experiments were performed in phosphate buffer solution (pH 7.4) containing different molar ratios of the drug and protein at 37 °C. The collected microdialysis sample with unbound TP was analyzed at the NiHCNFe CME in the LC-ED. The relative recovery of TP determined in vitro is 18.3% at a perfusion rate of 1.0 μl min−1 and the RSD is about 2.1%. The association constant and the number of binding sites on a BSA molecule calculated with the Scatchard equation are 3.72 × 10−3 (l mol−1) and 1.51, respectively. This method provides a fast, sensitive and simple technique for the study of drug–protein interactions.
- 20 September 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (10) , 1747-1750
A novel nano-Au-assembled gas sensor for atmospheric oxygen determination
A novel nano-Au-assembled gas sensor was fabricated and first used to determine atmospheric oxygen. The special characteristics of nano-Au resulted in a high catalytic activity for the reduction of oxygen. On determining 20.9% oxygen by cyclic voltammetry, on a nano-Au-assembled Pt disk electrode the overpotential decreased greatly and the reduction current of oxygen increased to about 4.4 times that on a bare gas sensor. For the determination of atmospheric oxygen by using this novel nano-Au-assembled gas sensor with the amperometric i–t curve method, the linear range was from 0.4 to 30.0%, the linear equation was y = 1.11x − 0.63 with a correlation coefficient of 0.9931, the sensitivity was 1.11 × 10−7 A cm−2 per 1% v/v, the detection limit was 0.2%, the response time was about 12 s and the relative standard deviation was 2.9% on determining the background value of atmospheric oxygen. It was also found that the nano-Au-assembled gas sensor had good reproducibility and stability. These results demonstrated that this sensor for the determination of atmospheric oxygen was fast, sensitive, accurate and convenient.
- 20 September 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (10) , 1747-1750
A novel nano-Au-assembled gas sensor for atmospheric oxygen determination
A novel nano-Au-assembled gas sensor was fabricated and first used to determine atmospheric oxygen. The special characteristics of nano-Au resulted in a high catalytic activity for the reduction of oxygen. On determining 20.9% oxygen by cyclic voltammetry, on a nano-Au-assembled Pt disk electrode the overpotential decreased greatly and the reduction current of oxygen increased to about 4.4 times that on a bare gas sensor. For the determination of atmospheric oxygen by using this novel nano-Au-assembled gas sensor with the amperometric i–t curve method, the linear range was from 0.4 to 30.0%, the linear equation was y = 1.11x − 0.63 with a correlation coefficient of 0.9931, the sensitivity was 1.11 × 10−7 A cm−2 per 1% v/v, the detection limit was 0.2%, the response time was about 12 s and the relative standard deviation was 2.9% on determining the background value of atmospheric oxygen. It was also found that the nano-Au-assembled gas sensor had good reproducibility and stability. These results demonstrated that this sensor for the determination of atmospheric oxygen was fast, sensitive, accurate and convenient.
- 20 April 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (5) , 669-672
Determination of sulfur dioxide in vitriol plant wastewater by using a polyNiMe4TAA electrochemically modified Pt microelectrode
A Pt microelectrode modified with nickel(II) polytetramethyldibenzo[b,i]tetraaza[14]annulene was prepared by electropolymerization of nickel(II) tetramethyldibenzo[b,i]tetraaza[14]annulene monomers and applied to determine sulfur dioxide in vitriol plant wastewater. For determination of SO2 with this electrochemically modified Pt microelectrode, the linear range was from 9.6 × 10−6 to 2.4 × 10−4 mol L−1, the sensitivity was 1.8 × 10−4 A L mol−1, the detection limit was calculated to be 4.8 × 10−6 mol L−1 (S/N = 3), the response time was less than 20 s and the relative standard deviation was found to be 2.1% on analyzing 4.8 × 10−5 mol L−1 SO2 solution repeatedly (n = 7). These results demonstrated good accuracy compared with those obtained by the conventional iodimetric method.
- 20 April 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (5) , 669-672
Determination of sulfur dioxide in vitriol plant wastewater by using a polyNiMe4TAA electrochemically modified Pt microelectrode
A Pt microelectrode modified with nickel(II) polytetramethyldibenzo[b,i]tetraaza[14]annulene was prepared by electropolymerization of nickel(II) tetramethyldibenzo[b,i]tetraaza[14]annulene monomers and applied to determine sulfur dioxide in vitriol plant wastewater. For determination of SO2 with this electrochemically modified Pt microelectrode, the linear range was from 9.6 × 10−6 to 2.4 × 10−4 mol L−1, the sensitivity was 1.8 × 10−4 A L mol−1, the detection limit was calculated to be 4.8 × 10−6 mol L−1 (S/N = 3), the response time was less than 20 s and the relative standard deviation was found to be 2.1% on analyzing 4.8 × 10−5 mol L−1 SO2 solution repeatedly (n = 7). These results demonstrated good accuracy compared with those obtained by the conventional iodimetric method.
- 29 August 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (10) , 1799-1804
Simultaneous amperometric detection of electroinactive anions and cations in ion chromatography
An amperometric detector with two working electrodes modified with polydiphenylamine (PDPA) and polydiphenylamine dodecyl sulfate (PDPA-DS) was successfully used for the simultaneous determination of electroinactive anions (SO4 2−, Cl−, NO3 −) and cations (Na+, NH4 + and K+) in single-column ion-exclusion chromatography–cation-exchange chromatography (IEC-CEC). The PDPA-DS chemically modified electrode (CME) was based on the incorporation of dodecyl sulfate (DS) into PDPA by electropolymerization of diphenylamine (DPA) in the presence of surfactant. The electrochemical responses against the anions and cations in differential pulse voltammetry were studied. A set of well-defined peaks of electroinactive anions and cations were obtained. The relative standard deviations (RSDs) of chromatographic peak height (nA) for anions were all −6–5.0 × 10−3 mol L−1 and their correlation coefficients were all >0.990. Their detection limits were investigated using 3s (where s represents the standard deviation of a blank solution, n = 11). They were 9.86 × 10−7 mol L−1 for SO4 2−, 6.92 × 10−7 mol L−1 for Cl−, 7.86 × 10−7 mol L−1 for NO3 −, 7.86 × 10−7 mol L−1 for Na+, 9.79 × 10−7 mol L−1 for NH4 + and 8.94 × 10−7 mol L−1 for K+. The recoveries of the anions and cations by this method were in the range 97.8–103%. The proposed method was rapid, sensitive and simple and was successfully applied to the analysis of rainwater samples. Both electrodes were stable during a 1 week period of operation with no evidence of chemical or mechanical deterioration.
- 29 August 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (10) , 1799-1804
Simultaneous amperometric detection of electroinactive anions and cations in ion chromatography
An amperometric detector with two working electrodes modified with polydiphenylamine (PDPA) and polydiphenylamine dodecyl sulfate (PDPA-DS) was successfully used for the simultaneous determination of electroinactive anions (SO4 2−, Cl−, NO3 −) and cations (Na+, NH4 + and K+) in single-column ion-exclusion chromatography–cation-exchange chromatography (IEC-CEC). The PDPA-DS chemically modified electrode (CME) was based on the incorporation of dodecyl sulfate (DS) into PDPA by electropolymerization of diphenylamine (DPA) in the presence of surfactant. The electrochemical responses against the anions and cations in differential pulse voltammetry were studied. A set of well-defined peaks of electroinactive anions and cations were obtained. The relative standard deviations (RSDs) of chromatographic peak height (nA) for anions were all −6–5.0 × 10−3 mol L−1 and their correlation coefficients were all >0.990. Their detection limits were investigated using 3s (where s represents the standard deviation of a blank solution, n = 11). They were 9.86 × 10−7 mol L−1 for SO4 2−, 6.92 × 10−7 mol L−1 for Cl−, 7.86 × 10−7 mol L−1 for NO3 −, 7.86 × 10−7 mol L−1 for Na+, 9.79 × 10−7 mol L−1 for NH4 + and 8.94 × 10−7 mol L−1 for K+. The recoveries of the anions and cations by this method were in the range 97.8–103%. The proposed method was rapid, sensitive and simple and was successfully applied to the analysis of rainwater samples. Both electrodes were stable during a 1 week period of operation with no evidence of chemical or mechanical deterioration.