Zhihua Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhihua Zhou has a total of 108 co-authors. Here are the top co-authors by number of shared publications:
Tianlong Huang
Department of Orthopedics, Second Xiangya Hospital, Central South University, Changsha, P. R. China
23 shared publications- Jianjun Fang
School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, P. R. China
19 shared publications Wenjuan Liu
Hunan Provincial Key Laboratory of Controllable Preparation and Functional Application of Fine Polymers, Hunan University of Science and Technology, Xiangtan, P. R. China
19 shared publicationsYanmin Zhao
School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, P.R. China
16 shared publicationsLihua Liu
School of Chemistry and Chemical Engineering, Hunan University of Science and Technology, Xiangtan, P. R. China
11 shared publicationsWei Wu
Daqing Petrochemical Research Institute of CNPC, Daqing, P. R. China
9 shared publications
Latest Publications
- 1 March 2025
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 31 (5-6) , 255-266
Silk Fibroin-Laponite Porous Microspheres as Cell Microcarriers for Osteogenic Differentiation
Silk fibroin (SF) has garnered significant attention as a natural polymer for fabricating porous scaffolds in various engineering applications. However, the limited osteoinductive property of SF ha...
- 1 March 2025
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 31 (5-6) , 255-266
Silk Fibroin-Laponite Porous Microspheres as Cell Microcarriers for Osteogenic Differentiation
Silk fibroin (SF) has garnered significant attention as a natural polymer for fabricating porous scaffolds in various engineering applications. However, the limited osteoinductive property of SF ha...
- 13 March 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1253, 341092
The composite of bismuth oxyiodide-bismuth/nitrogen-doped carbon for photoreduction and electrochemical/photoelectrochemical dual-model sensing of Cr(VI)
- 13 March 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1253, 341092
The composite of bismuth oxyiodide-bismuth/nitrogen-doped carbon for photoreduction and electrochemical/photoelectrochemical dual-model sensing of Cr(VI)
- 2 November 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (10-11) , 1270-1281
In-Vitro Degradation and Biological Properties of Poly(Lactide-co-Glycolide-co-ε-Caprolactone)/Ethanediamine Modified Poly(Lactide-co-Glycolide) Blend Scaffolds
A degradable blend scaffold composed of poly(D,L-lactide-co-glycolide-co-ε-caprolactone) (PLLGC) and ethanediamine modified poly(lactide-co-glycolide) (EMPLGA) was prepared by using a thermally induced phase separation technique. The morphologies of the PLLGC/EMPLGA blend scaffolds were characterized by using scanning electron microscopy (SEM). The in-vitro degradation behaviors and biocompatibility of the individual components and the blend were investigated by using rat L929 cells. The blend scaffolds showed a porous and well interconnected pore structure. The degradation rate sequence of the three scaffolds, the individual components and the blend, was EMPLGA > PLLGC/EMPLGA > PLLGC. The PLLGC/EMPLGA blend scaffold was non-cytotoxic and showed high cell proliferation.
- 2 November 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (10-11) , 1270-1281
In-Vitro Degradation and Biological Properties of Poly(Lactide-co-Glycolide-co-ε-Caprolactone)/Ethanediamine Modified Poly(Lactide-co-Glycolide) Blend Scaffolds
A degradable blend scaffold composed of poly(D,L-lactide-co-glycolide-co-ε-caprolactone) (PLLGC) and ethanediamine modified poly(lactide-co-glycolide) (EMPLGA) was prepared by using a thermally induced phase separation technique. The morphologies of the PLLGC/EMPLGA blend scaffolds were characterized by using scanning electron microscopy (SEM). The in-vitro degradation behaviors and biocompatibility of the individual components and the blend were investigated by using rat L929 cells. The blend scaffolds showed a porous and well interconnected pore structure. The degradation rate sequence of the three scaffolds, the individual components and the blend, was EMPLGA > PLLGC/EMPLGA > PLLGC. The PLLGC/EMPLGA blend scaffold was non-cytotoxic and showed high cell proliferation.
- 3 June 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (6) , 776-787
In-Vitro Degradation Behaviors of Composite Scaffolds Based on Poly(Lactide-co-Glycolide-co-ε-Caprolactone), 1,4-Butanediamine Modified Poly(Lactide-co-Glycolide) and Bioceramics
In this work a novel type of composite scaffolds based on poly(lactide-co-glycolide-co-ε-caprolactone) (PLLGC), 1,4-butanediamine modified poly(lactide-co-glycolide) (BMPLGA), nanobioactive glass (NBAG) and β-tricalcium phosphate (β-TCP) were fabricated by using a thermally induced phase separation (TIPS) method. The in-vitro degradation behaviors were investigated by immersing the scaffolds in phosphate buffered saline (PBS, pH = 7.27) solution at 37 °C for 40 days. The properties, including the PBS pH value change and the water uptake, mass loss and morphology changes of the composite scaffolds, were investigated by comparing with pure PLLGC/BMPLGA scaffolds. The introduction of NBAG and β-TCP nanoparticles decreased the degradation rate of the PLLGC/BMPLGA matrix and improved the wetting behavior. The decrease in the degradation rate of the composite scaffolds correlated well with the results obtained from mass loss, water uptake and pH measurements. The degradation rate of the PLLGC/BMPLGA polymer in the composite scaffolds decreased as a result of the alkaline effect of the NBAG and β-TCP particles, with the OH- ions formed neutralizing acidic polymeric degradation products and binding the H+ ions from the tissue fluids.
- 3 June 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (6) , 776-787
In-Vitro Degradation Behaviors of Composite Scaffolds Based on Poly(Lactide-co-Glycolide-co-ε-Caprolactone), 1,4-Butanediamine Modified Poly(Lactide-co-Glycolide) and Bioceramics
In this work a novel type of composite scaffolds based on poly(lactide-co-glycolide-co-ε-caprolactone) (PLLGC), 1,4-butanediamine modified poly(lactide-co-glycolide) (BMPLGA), nanobioactive glass (NBAG) and β-tricalcium phosphate (β-TCP) were fabricated by using a thermally induced phase separation (TIPS) method. The in-vitro degradation behaviors were investigated by immersing the scaffolds in phosphate buffered saline (PBS, pH = 7.27) solution at 37 °C for 40 days. The properties, including the PBS pH value change and the water uptake, mass loss and morphology changes of the composite scaffolds, were investigated by comparing with pure PLLGC/BMPLGA scaffolds. The introduction of NBAG and β-TCP nanoparticles decreased the degradation rate of the PLLGC/BMPLGA matrix and improved the wetting behavior. The decrease in the degradation rate of the composite scaffolds correlated well with the results obtained from mass loss, water uptake and pH measurements. The degradation rate of the PLLGC/BMPLGA polymer in the composite scaffolds decreased as a result of the alkaline effect of the NBAG and β-TCP particles, with the OH- ions formed neutralizing acidic polymeric degradation products and binding the H+ ions from the tissue fluids.
- 4 May 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (4-5) , 636-648
Preparation and Properties of Sodium Alginate/Silk Fibroin Microcarriers
Injectable porous microcarriers, with excellent biocompatibility, biodegradability, high cell seeding density and simple implantable procedures in the body, have been widely used in bone tissue engineering. In this work sodium alginate/silk fibroin (SA/SF) porous microcarriers were prepared cross-linked by SrCl2 or CaCl2 using emulsion method combined with freeze-drying method. The morphology and structure of the microcarriers were characterized by scanning electron microscopy (SEM). The cell proliferation ability and osteogenic activity of the microcarriers were investigated by culturing rat bone marrow mesenchymal stem cells (rBMSCs). The SA/SF microcarriers showed an interconnective porous structure with an average particle size of 254.3 ± 50.0 μm and an average pore size of 42.0 ± 5.3 μm. The SA/SF microcarriers cross-linked with SrCl2 showed higher cell proliferation ability and osteoinductive ability than those cross-linked with CaCl2. These features indicated that the designed SA/SF microcarriers are ideal for tissue engineering.
- 4 May 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (4-5) , 636-648
Preparation and Properties of Sodium Alginate/Silk Fibroin Microcarriers
Injectable porous microcarriers, with excellent biocompatibility, biodegradability, high cell seeding density and simple implantable procedures in the body, have been widely used in bone tissue engineering. In this work sodium alginate/silk fibroin (SA/SF) porous microcarriers were prepared cross-linked by SrCl2 or CaCl2 using emulsion method combined with freeze-drying method. The morphology and structure of the microcarriers were characterized by scanning electron microscopy (SEM). The cell proliferation ability and osteogenic activity of the microcarriers were investigated by culturing rat bone marrow mesenchymal stem cells (rBMSCs). The SA/SF microcarriers showed an interconnective porous structure with an average particle size of 254.3 ± 50.0 μm and an average pore size of 42.0 ± 5.3 μm. The SA/SF microcarriers cross-linked with SrCl2 showed higher cell proliferation ability and osteoinductive ability than those cross-linked with CaCl2. These features indicated that the designed SA/SF microcarriers are ideal for tissue engineering.
- 4 May 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (4-5) , 622-635
Preparation and Characterization of Poly(lactide-co-glycolide-co-ε-caprolactone)- 1,4-Butanediamine-Modified Poly(lactide-co-glycolide)/Nano-Biaoactive Glass-β-Tricalcium Phosphate Composite Scaffolds
Polymer/bioceramic composite scaffolds have gained importance in treating bone defects. In this paper we described a novel degradable scaffold material for bone tissue repairing prepared by combining poly(lactide-co-glycolide-co-ε-caprolactone) (PLLGC) and 1,4-butanediamine-modified poly(lactide-co-glycolide) (BMPLGA) with nano-biaoactive glass (NBAG) and nano β-tricalcium phosphate (β-TCP). The composite scaffolds were characterized by using Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) techniques. The FTIR results indicated that the inorganic fillers of NBAG and β-TCP were successfully incorporated into the PLLGC/BMPLGA matrix. The influences of the inorganic filler content and freezing temperature on the porosity and compressive strength of the composite scaffolds were studied. The composite scaffolds showed an interconnected pore structure with the pore size ranging from 20 to 100 μm depending on the freezing temperature and the inorganic fillers. The compressive strength was enhanced with increasing content of the inorganic fillers and the freezing temperature; however, the porosity decreased. We suggest the PLLGC-BMPLGA/NBAG-β-TCP composite scaffolds have great potential for application in bone tissue regeneration.
- 4 May 2022
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (4-5) , 622-635
Preparation and Characterization of Poly(lactide-co-glycolide-co-ε-caprolactone)- 1,4-Butanediamine-Modified Poly(lactide-co-glycolide)/Nano-Biaoactive Glass-β-Tricalcium Phosphate Composite Scaffolds
Polymer/bioceramic composite scaffolds have gained importance in treating bone defects. In this paper we described a novel degradable scaffold material for bone tissue repairing prepared by combining poly(lactide-co-glycolide-co-ε-caprolactone) (PLLGC) and 1,4-butanediamine-modified poly(lactide-co-glycolide) (BMPLGA) with nano-biaoactive glass (NBAG) and nano β-tricalcium phosphate (β-TCP). The composite scaffolds were characterized by using Fourier transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) techniques. The FTIR results indicated that the inorganic fillers of NBAG and β-TCP were successfully incorporated into the PLLGC/BMPLGA matrix. The influences of the inorganic filler content and freezing temperature on the porosity and compressive strength of the composite scaffolds were studied. The composite scaffolds showed an interconnected pore structure with the pore size ranging from 20 to 100 μm depending on the freezing temperature and the inorganic fillers. The compressive strength was enhanced with increasing content of the inorganic fillers and the freezing temperature; however, the porosity decreased. We suggest the PLLGC-BMPLGA/NBAG-β-TCP composite scaffolds have great potential for application in bone tissue regeneration.
- 12 November 2021
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (2) , 270-280
Preparation and Properties of Poly(D,L-lactide-co-glycolide-co-ε-caprolactone)/1,4-Butanediamine Modified Poly(lactide-co-glycolide) Blend Porous Microspheres
Composite porous microspheres based on blends of poly(D,L-lactide-co-glycolide-co-ε-caprolactone) (PLGCL) and 1,4-butanediamine modified poly(D,L-lactide-co-glycolide) (BMPLGA) were prepared by using a combined solvent evaporation and particle leaching technique. The morphologies and porous structure of the PLGCL/BMPLGA microspheres were observed by using scanning electron microscopy (SEM). The in-vitro degradation behaviors and cytocompatibility were studied. The resultant microspheres showed a porous surface and a three-dimensional network structure with interconnecting pores. The changes of morphologies, pH value and mass loss during in-vitro degradation in phosphate buffered solution (PBS) at 37°C indicated that the degradation rate of the BMPLGA was faster than that of the PLGCL in the PLGCL/BMPLGA blends. We suggest the PLGCL/BMPLGA porous microspheres were non-cytotoxic and showed excellent cytocompatibility. We suggest the PLGCL/BMPLGA porous polymeric microspheres have great potential for application for drugs delivery and tissue regeneration.
- 12 November 2021
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 61 (2) , 270-280
Preparation and Properties of Poly(D,L-lactide-co-glycolide-co-ε-caprolactone)/1,4-Butanediamine Modified Poly(lactide-co-glycolide) Blend Porous Microspheres
Composite porous microspheres based on blends of poly(D,L-lactide-co-glycolide-co-ε-caprolactone) (PLGCL) and 1,4-butanediamine modified poly(D,L-lactide-co-glycolide) (BMPLGA) were prepared by using a combined solvent evaporation and particle leaching technique. The morphologies and porous structure of the PLGCL/BMPLGA microspheres were observed by using scanning electron microscopy (SEM). The in-vitro degradation behaviors and cytocompatibility were studied. The resultant microspheres showed a porous surface and a three-dimensional network structure with interconnecting pores. The changes of morphologies, pH value and mass loss during in-vitro degradation in phosphate buffered solution (PBS) at 37°C indicated that the degradation rate of the BMPLGA was faster than that of the PLGCL in the PLGCL/BMPLGA blends. We suggest the PLGCL/BMPLGA porous microspheres were non-cytotoxic and showed excellent cytocompatibility. We suggest the PLGCL/BMPLGA porous polymeric microspheres have great potential for application for drugs delivery and tissue regeneration.
- 1 September 2021
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 128, 112354
Strontium mineralized silk fibroin porous microcarriers with enhanced osteogenesis as injectable bone tissue engineering vehicles
- 1 September 2021
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 128, 112354
Strontium mineralized silk fibroin porous microcarriers with enhanced osteogenesis as injectable bone tissue engineering vehicles
- 2 February 2021
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 60 (7) , 521-529
In-vitro Degradation Behaviors of Poly(L-lactide-co-glycolide-co-ε-caprolactone) Microspheres
Among drug delivery systems, polymer microspheres have been proved to be the most promising carriers during the past several years. In this paper we describe the preparation of poly(L-lactide-co-glycolide-co-ε-caprolactone) (PLLGC) random terpolymer microspheres; their in-vitro degradation behaviors, including the changes of pH value, mass loss, molecular mass and surface morphology, were investigated during various degradation periods and compared with poly(lactic-co-glycolic acid) (PLGA) microspheres. The results showed that the introduction of the ε-caprolactone (ε-CL) unit reduced the degradation rate of the PLGA polymers. Therefore, we suggest the PLLGC microspheres with controllable degradation rate could supply a wider application future in drug delivery field than pure PLGA microspheres.
- 2 February 2021
- Published by Taylor & Francis in Journal of Macromolecular Science, Part B
- Vol. 60 (7) , 521-529
In-vitro Degradation Behaviors of Poly(L-lactide-co-glycolide-co-ε-caprolactone) Microspheres
Among drug delivery systems, polymer microspheres have been proved to be the most promising carriers during the past several years. In this paper we describe the preparation of poly(L-lactide-co-glycolide-co-ε-caprolactone) (PLLGC) random terpolymer microspheres; their in-vitro degradation behaviors, including the changes of pH value, mass loss, molecular mass and surface morphology, were investigated during various degradation periods and compared with poly(lactic-co-glycolic acid) (PLGA) microspheres. The results showed that the introduction of the ε-caprolactone (ε-CL) unit reduced the degradation rate of the PLGA polymers. Therefore, we suggest the PLLGC microspheres with controllable degradation rate could supply a wider application future in drug delivery field than pure PLGA microspheres.
- Open Access
Onsite Tests and Numerical Simulation of Broken Rock Zones in Surrounding Rocks of Seepage Roadways under Blasting
To study the influence of blasting vibration on the broken rock zone around a seepage roadway and provide guidance for design of the roadway support, the broken rock zones around rock of seepage roadways under production blasting vibration are determined by onsite tests in a mining area, Daye iron mine. During the testing process, it is found that blasting vibration causes internal cracks of surrounding rocks to initiate and develop, the fracture density increases, the acoustic wave velocity of rock mass decreases, and the broken rock zones expand. At the same time, through onsite observation, it is found that blasting vibration results in crack development and formation of a water pathway to lead to surface water into the ground. The mechanical response around rock of the seepage roadway under blasting vibration is simulated by the two-dimensional realistic fracture progress analysis calculation software (RFPA2D). It is found that internal cracks of roadway surrounding rock initiate, propagate, and join up gradually, and the fracture range is expanding under the seepage water pressure, ground stress, and cyclic loads, and the broken rock zones also expand. The results from numerical simulation are consistent with the results of onsite tests. It is also found that the tensile stress appears around some cracks, leading to part of the cracks more likely to generate shear failure under the seepage water pressure during simulation.
Open AccessOnsite Tests and Numerical Simulation of Broken Rock Zones in Surrounding Rocks of Seepage Roadways under Blasting
To study the influence of blasting vibration on the broken rock zone around a seepage roadway and provide guidance for design of the roadway support, the broken rock zones around rock of seepage roadways under production blasting vibration are determined by onsite tests in a mining area, Daye iron mine. During the testing process, it is found that blasting vibration causes internal cracks of surrounding rocks to initiate and develop, the fracture density increases, the acoustic wave velocity of rock mass decreases, and the broken rock zones expand. At the same time, through onsite observation, it is found that blasting vibration results in crack development and formation of a water pathway to lead to surface water into the ground. The mechanical response around rock of the seepage roadway under blasting vibration is simulated by the two-dimensional realistic fracture progress analysis calculation software (RFPA2D). It is found that internal cracks of roadway surrounding rock initiate, propagate, and join up gradually, and the fracture range is expanding under the seepage water pressure, ground stress, and cyclic loads, and the broken rock zones also expand. The results from numerical simulation are consistent with the results of onsite tests. It is also found that the tensile stress appears around some cracks, leading to part of the cracks more likely to generate shear failure under the seepage water pressure during simulation.