Hiroyuki Kishimoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hiroyuki Kishimoto has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Akihisa Takeuchi
Research and Utilization Division, Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan
3 shared publicationsYoshio Suzuki
Research and Utilization Division, Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan
3 shared publications- Yuya Shinohara
Materials Science and Technology Division, Oak Ridge National Laboratory 3 , Oak Ridge, Tennessee 37831
3 shared publications Naoto Yagi
Research and Utilization Division, Japan Synchrotron Radiation Research Institute, 1-1-1 Kouto, Sayo, Hyogo 679-5198, Japan
2 shared publications- Ryo Mashita
Sumitomo Rubber Industries, Ltd., Japan
2 shared publications - Satoshi Koizumi
Institute of Quantum Beam Science, Ibaraki University, Ibaraki, 316-8511, Japan
2 shared publications
Latest Publications
- Open Access
- 20 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (2) , 492-512
Spin-contrast-variation small-angle neutron scattering study of fully and partially swollen silica-filled rubber
We have elucidated the polymer adsorption layer structure in filler–rubber systems by conducting spin-contrast-variation small-angle neutron scattering (SANS) on partially and fully swollen filler–rubber samples with and without a silane coupling agent. In spin-contrast-variation SANS, dynamic nuclear polarization (DNP) was used to polarize protons and change their scattering length with respect to polarized neutron beams significantly. SANS measurements were performed in dynamically polarized states using a DNP cryostat (1.2 K and 3.35 T). From SANS profiles obtained at various proton spin polarizations, partial scattering functions (PSFs) for each component were separated by regarding each sample as a three-component system composed of silica, polymer and deuterated toluene. To analyze the obtained PSFs in detail, we built a structure model for the silica aggregates and the surrounding polymer adsorption layer. Numerical calculation based on this model successfully reproduced the experimentally obtained PSFs, providing the structural parameters of the silica aggregates and polymer adsorption layer. The results showed a considerable difference in structural parameters between the partially and fully swollen states. For the sample with the silane coupling agent, the thickness of the polymer adsorption layer decreased as the solvent fraction increased. The difference in polymer volume fraction between the polymer adsorption layer and the outside matrix was very small in less swollen states but significant in the fully swollen state. Furthermore, the scattering contribution of the polymer chains in the solvent was accurately separated via contrast variation. In the swollen silica-filled rubber without the silane coupling agent, the size of the polymer-dense regions was almost constant, regardless of the swelling ratio. By contrast, in the swollen silica-filled rubber with the silane coupling agent, the size of the polymer-dense regions significantly increased by a factor of 2 with an increase in the swelling ratio.
- 20 March 2026
- Published by International Union of Crystallography (IUCr) in Journal of Applied Crystallography
- Vol. 59 (2) , 492-512
Open AccessSpin-contrast-variation small-angle neutron scattering study of fully and partially swollen silica-filled rubber
We have elucidated the polymer adsorption layer structure in filler–rubber systems by conducting spin-contrast-variation small-angle neutron scattering (SANS) on partially and fully swollen filler–rubber samples with and without a silane coupling agent. In spin-contrast-variation SANS, dynamic nuclear polarization (DNP) was used to polarize protons and change their scattering length with respect to polarized neutron beams significantly. SANS measurements were performed in dynamically polarized states using a DNP cryostat (1.2 K and 3.35 T). From SANS profiles obtained at various proton spin polarizations, partial scattering functions (PSFs) for each component were separated by regarding each sample as a three-component system composed of silica, polymer and deuterated toluene. To analyze the obtained PSFs in detail, we built a structure model for the silica aggregates and the surrounding polymer adsorption layer. Numerical calculation based on this model successfully reproduced the experimentally obtained PSFs, providing the structural parameters of the silica aggregates and polymer adsorption layer. The results showed a considerable difference in structural parameters between the partially and fully swollen states. For the sample with the silane coupling agent, the thickness of the polymer adsorption layer decreased as the solvent fraction increased. The difference in polymer volume fraction between the polymer adsorption layer and the outside matrix was very small in less swollen states but significant in the fully swollen state. Furthermore, the scattering contribution of the polymer chains in the solvent was accurately separated via contrast variation. In the swollen silica-filled rubber without the silane coupling agent, the size of the polymer-dense regions was almost constant, regardless of the swelling ratio. By contrast, in the swollen silica-filled rubber with the silane coupling agent, the size of the polymer-dense regions significantly increased by a factor of 2 with an increase in the swelling ratio.
- Open Access
- 23 August 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (5) , 1180-1186
Microscopic observation of the effects of elongation on the polymer chain dynamics of crosslinked polybutadiene using quasi-elastic γ-ray scattering
A synchrotron-radiation-based quasi-elastic γ-ray scattering system has been developed that uses time-domain interferometry to observe microscopic polymer dynamics under uniaxial deformation. The stress-producing mechanism of crosslinked polybutadiene has been studied from a microscopic viewpoint. It was found that the mean relaxation time 〈τ〉 of the microscopic polymer motion observed over a relatively high temperature (T) range (i.e. T −1 < 0.0045 K−1) increased with elongation on both the intra- and intermolecular scales. Following an extensive strain dependence study, it was found that the strain dependences of both the intra- and intermolecular 〈τ〉 changed with the stress dependence. It was therefore suggested that 〈τ〉 increased due to the constraint of the local polymer chain motion caused by elongation. The local molecular dynamics of polymer chains under uniaxial deformation could be evaluated at intra- and intermolecular scales separately for the first time using our method.
- 23 August 2022
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 29 (5) , 1180-1186
Open AccessMicroscopic observation of the effects of elongation on the polymer chain dynamics of crosslinked polybutadiene using quasi-elastic γ-ray scattering
A synchrotron-radiation-based quasi-elastic γ-ray scattering system has been developed that uses time-domain interferometry to observe microscopic polymer dynamics under uniaxial deformation. The stress-producing mechanism of crosslinked polybutadiene has been studied from a microscopic viewpoint. It was found that the mean relaxation time 〈τ〉 of the microscopic polymer motion observed over a relatively high temperature (T) range (i.e. T −1 < 0.0045 K−1) increased with elongation on both the intra- and intermolecular scales. Following an extensive strain dependence study, it was found that the strain dependences of both the intra- and intermolecular 〈τ〉 changed with the stress dependence. It was therefore suggested that 〈τ〉 increased due to the constraint of the local polymer chain motion caused by elongation. The local molecular dynamics of polymer chains under uniaxial deformation could be evaluated at intra- and intermolecular scales separately for the first time using our method.
- 19 July 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (5) , 1610-1615
Development and application of a tender X-ray ptychographic coherent diffraction imaging system on BL27SU at SPring-8
Ptychographic coherent diffraction imaging (CDI) allows the visualization of both the structure and chemical state of materials on the nanoscale, and has been developed for use in the soft and hard X-ray regions. In this study, a ptychographic CDI system with pinhole or Fresnel zone-plate optics for use in the tender X-ray region (2–5 keV) was developed on beamline BL27SU at SPring-8, in which high-precision pinholes optimized for the tender energy range were used to obtain diffraction intensity patterns with a low background, and a temperature stabilization system was developed to reduce the drift of the sample position. A ptychography measurement of a 200 nm thick tantalum test chart was performed at an incident X-ray energy of 2.500 keV, and the phase image of the test chart was successfully reconstructed with approximately 50 nm resolution. As an application to practical materials, a sulfur polymer material was measured in the range of 2.465 to 2.500 keV including the sulfur K absorption edge, and the phase and absorption images were successfully reconstructed and the nanoscale absorption/phase spectra were derived from images at multiple energies. In 3 GeV synchrotron radiation facilities with a low-emittance storage ring, the use of the present system will allow the visualization on the nanoscale of the chemical states of various light elements that play important roles in materials science, biology and environmental science.
- 19 July 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (5) , 1610-1615
Development and application of a tender X-ray ptychographic coherent diffraction imaging system on BL27SU at SPring-8
Ptychographic coherent diffraction imaging (CDI) allows the visualization of both the structure and chemical state of materials on the nanoscale, and has been developed for use in the soft and hard X-ray regions. In this study, a ptychographic CDI system with pinhole or Fresnel zone-plate optics for use in the tender X-ray region (2–5 keV) was developed on beamline BL27SU at SPring-8, in which high-precision pinholes optimized for the tender energy range were used to obtain diffraction intensity patterns with a low background, and a temperature stabilization system was developed to reduce the drift of the sample position. A ptychography measurement of a 200 nm thick tantalum test chart was performed at an incident X-ray energy of 2.500 keV, and the phase image of the test chart was successfully reconstructed with approximately 50 nm resolution. As an application to practical materials, a sulfur polymer material was measured in the range of 2.465 to 2.500 keV including the sulfur K absorption edge, and the phase and absorption images were successfully reconstructed and the nanoscale absorption/phase spectra were derived from images at multiple energies. In 3 GeV synchrotron radiation facilities with a low-emittance storage ring, the use of the present system will allow the visualization on the nanoscale of the chemical states of various light elements that play important roles in materials science, biology and environmental science.
- 1 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (1) , 322-326
High-speed rotating device for X-ray tomography with 10 ms temporal resolution
The temporal resolution of X-ray tomography, using a synchrotron radiation X-ray source, has been improved to millisecond order in recent years. However, the sample must be rotated at a speed of more than a few thousand revolutions per minute, which makes it difficult to control the environment around the sample. In this study, a high-speed rotation device has been developed, comprising two synchronized coaxial motors movable along the direction of the axis, which can stretch or compress the rotating sample. Using this device, tomograms of breaking rubber were successfully obtained at a temporal resolution of 10 ms.
- 1 January 2021
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 28 (1) , 322-326
High-speed rotating device for X-ray tomography with 10 ms temporal resolution
The temporal resolution of X-ray tomography, using a synchrotron radiation X-ray source, has been improved to millisecond order in recent years. However, the sample must be rotated at a speed of more than a few thousand revolutions per minute, which makes it difficult to control the environment around the sample. In this study, a high-speed rotation device has been developed, comprising two synchronized coaxial motors movable along the direction of the axis, which can stretch or compress the rotating sample. Using this device, tomograms of breaking rubber were successfully obtained at a temporal resolution of 10 ms.
- Open Access
- 25 September 2020
- Published by MDPI AG in Quantum Beam Science
- Vol. 4 (4) , 33
First Experiment of Spin Contrast Variation Small-Angle Neutron Scattering on the iMATERIA Instrument at J-PARC
Recently, we have developed a novel dynamic nuclear polarization (DNP) apparatus with a magnetic field of 7 T and a sample temperature of 1 K. High proton spin polarizations from −84% to 76%, for TEMPO doped polystyrene samples, have been demonstrated. This DNP apparatus satisfies the simultaneous requirement for quick and easy sample exchange and high DNP performance. On the iMATERIA (BL20) instrument at J-PARC, the first beam experiment using this DNP apparatus has been performed. For this experiment, the beamline was equipped with a supermirror polarizer. The stray magnetic field due to the superconducting magnet for DNP was also evaluated. The stray magnetic field plays an important role for in maintaining the neutron polarization during the transportation from the polarizer to the sample. The small-angle neutron scattering (SANS) profiles of silica-filled rubber under dynamically polarized conditions are presented. By applying our new analytical approach for SANS coherent scattering intensity, neutron polarization (PN) as a function of neutron wavelength was determined. Consequently, for the neutron wavelength, range from 4 Å to 10 Å, |PN| was sufficient for DNP-SANS studies.
- 25 September 2020
- Published by MDPI AG in Quantum Beam Science
- Vol. 4 (4) , 33
Open AccessFirst Experiment of Spin Contrast Variation Small-Angle Neutron Scattering on the iMATERIA Instrument at J-PARC
Recently, we have developed a novel dynamic nuclear polarization (DNP) apparatus with a magnetic field of 7 T and a sample temperature of 1 K. High proton spin polarizations from −84% to 76%, for TEMPO doped polystyrene samples, have been demonstrated. This DNP apparatus satisfies the simultaneous requirement for quick and easy sample exchange and high DNP performance. On the iMATERIA (BL20) instrument at J-PARC, the first beam experiment using this DNP apparatus has been performed. For this experiment, the beamline was equipped with a supermirror polarizer. The stray magnetic field due to the superconducting magnet for DNP was also evaluated. The stray magnetic field plays an important role for in maintaining the neutron polarization during the transportation from the polarizer to the sample. The small-angle neutron scattering (SANS) profiles of silica-filled rubber under dynamically polarized conditions are presented. By applying our new analytical approach for SANS coherent scattering intensity, neutron polarization (PN) as a function of neutron wavelength was determined. Consequently, for the neutron wavelength, range from 4 Å to 10 Å, |PN| was sufficient for DNP-SANS studies.
- Open Access
- 2 November 2013
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 21 (1) , 1-4
Pinhole-type two-dimensional ultra-small-angle X-ray scattering on the micrometer scale
A pinhole-type two-dimensional ultra-small-angle X-ray scattering set-up at a so-called medium-length beamline at SPring-8 is reported. A long sample-to-detector distance, 160.5 m, can be used at this beamline and a small-angle resolution of 0.25 µm−1was thereby achieved at an X-ray energy of 8 keV.
- 2 November 2013
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 21 (1) , 1-4
Open AccessPinhole-type two-dimensional ultra-small-angle X-ray scattering on the micrometer scale
A pinhole-type two-dimensional ultra-small-angle X-ray scattering set-up at a so-called medium-length beamline at SPring-8 is reported. A long sample-to-detector distance, 160.5 m, can be used at this beamline and a small-angle resolution of 0.25 µm−1was thereby achieved at an X-ray energy of 8 keV.
- 14 November 2012
- Published by Springer Nature in Polymer Journal
- Vol. 45 (1) , 64-69
Visualization of nanoscale deformation in polymer composites with zernike-type phase-contrast X-ray microscopy and the finite element method
- 14 November 2012
- Published by Springer Nature in Polymer Journal
- Vol. 45 (1) , 64-69
Visualization of nanoscale deformation in polymer composites with zernike-type phase-contrast X-ray microscopy and the finite element method
- 1 September 2008
- Published by Rubber Division, ACS in Rubber Chemistry and Technology
- Vol. 81 (4) , 541-551
Structural Analysis of Filler in Rubber Composite under Stretch with Time-Resolved Two-Dimensional Ultra-Small-Angle X-Ray Scattering
We investigated the hierarchical structure of silica, especially agglomerate structure, in stretched rubber by time-resolved two-dimensional ultra-small-angle X-ray scattering (2D-USAXS). Time-resolved 2D-USAXS measurements give us the in-situ structural information up to 5 μm during sample deformation. The results are summarized as follows: at first, the agglomerate is turned so that the long axis of the agglomerate is parallel to the stretching direction, and the “weakly-bonded agglomerates” weakly bonding between agglomerates is broken down. Second, the distance between agglomerates increases with the small deformation of agglomerate. Finally, the “tightly-bonded agglomerates” strongly bonding between agglomerates start to deform. Existence of silane-coupling agents causes the differences in the manner of agglomerate deformation. These kinds of structural information will be a key to understanding the origin of rubber reinforcement by filler such as carbon black and silica.
- 1 September 2008
- Published by Rubber Division, ACS in Rubber Chemistry and Technology
- Vol. 81 (4) , 541-551
Structural Analysis of Filler in Rubber Composite under Stretch with Time-Resolved Two-Dimensional Ultra-Small-Angle X-Ray Scattering
We investigated the hierarchical structure of silica, especially agglomerate structure, in stretched rubber by time-resolved two-dimensional ultra-small-angle X-ray scattering (2D-USAXS). Time-resolved 2D-USAXS measurements give us the in-situ structural information up to 5 μm during sample deformation. The results are summarized as follows: at first, the agglomerate is turned so that the long axis of the agglomerate is parallel to the stretching direction, and the “weakly-bonded agglomerates” weakly bonding between agglomerates is broken down. Second, the distance between agglomerates increases with the small deformation of agglomerate. Finally, the “tightly-bonded agglomerates” strongly bonding between agglomerates start to deform. Existence of silane-coupling agents causes the differences in the manner of agglomerate deformation. These kinds of structural information will be a key to understanding the origin of rubber reinforcement by filler such as carbon black and silica.