Gloria Tamborini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gloria Tamborini has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
Mauro Pepi
6 shared publications- Francesco Maffessanti
Department of Medicine, Section of Cardiology, University of Chicago, Chicago, Illinois
5 shared publications - Mauro Pepi
Centro Cardiologico Monzino, IRCCS , Milano
5 shared publications Anna Maltagliati
4 shared publicationsManuela Muratori
4 shared publications- Manuela Muratori
Department of Perioperative Cardiology and Cardiovascular Imaging, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy
4 shared publications
Latest Publications
- Open Access
- 10 August 2009
- Published by Touch Medical Media, Ltd. in Heart International
- Vol. 3 (1) , 35
Three-dimensional echocardiography in valve disease
This review covers the role of three-dimensional (3D) echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic) and quantitative advantages of this technique. (Heart International 2007; 3: 35-41)
- 10 August 2009
- Published by Touch Medical Media, Ltd. in Heart International
- Vol. 3 (1) , 35
Open AccessThree-dimensional echocardiography in valve disease
This review covers the role of three-dimensional (3D) echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic) and quantitative advantages of this technique. (Heart International 2007; 3: 35-41)
- Open Access
- 27 February 2009
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 10 (5) , 630-634
Is right ventricular systolic function reduced after cardiac surgery? A two- and three-dimensional echocardiographic study
A reduction in tricuspid annular plane systolic excursion (TAPSE) and peak systolic velocity (PSV) of tricuspid annulus after cardiac surgery is a well-known phenomenon, even though its origin is not well established. Recently, a new three-dimensional (3D) echocardiographic software adapted for right ventricular (RV) analysis has been validated. Aims of this study were to evaluate RV function in patients with mitral valve prolapse undergoing surgical valvular repair and to compare and correlate 3D RV ejection fraction (RVEF) with TAPSE and PSV before and after surgery. Forty patients were studied by transthoracic 2D and 3D echocardiography pre- and 3, 6, and 12 months post-surgery. TAPSE (15.5 ± 3, 16.5 ± 3, and 18.5 ± 4 mm at 3, 6, and 12 months, respectively) and PSV (11.9 ± 2, 12 ± 2, and 12.8 ± 3 cm/s at 3, 6, and 12 months, respectively) were significantly ( P < 0.001) lower after surgery in comparison with pre-surgical values (TAPSE: 25.3 ± 4 mm; PSV: 17.8 ± 4 cm/s). On the contrary, pre-operative RVEF (58.4 ± 4%) did not change after surgery (56.9 ± 5, 59.5 ± 5, and 58.5 ± 5% at each step). Despite the post-operative reduction of RV performance along the long axis suggested by TAPSE and PSV, the absence of a decrease in 3D RVEF leads to caution in the interpretation of these 2D and Doppler parameters after cardiac surgery, supporting the hypothesis of geometrical rather than functional changes in the right ventricle.
- 27 February 2009
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 10 (5) , 630-634
Open AccessIs right ventricular systolic function reduced after cardiac surgery? A two- and three-dimensional echocardiographic study
A reduction in tricuspid annular plane systolic excursion (TAPSE) and peak systolic velocity (PSV) of tricuspid annulus after cardiac surgery is a well-known phenomenon, even though its origin is not well established. Recently, a new three-dimensional (3D) echocardiographic software adapted for right ventricular (RV) analysis has been validated. Aims of this study were to evaluate RV function in patients with mitral valve prolapse undergoing surgical valvular repair and to compare and correlate 3D RV ejection fraction (RVEF) with TAPSE and PSV before and after surgery. Forty patients were studied by transthoracic 2D and 3D echocardiography pre- and 3, 6, and 12 months post-surgery. TAPSE (15.5 ± 3, 16.5 ± 3, and 18.5 ± 4 mm at 3, 6, and 12 months, respectively) and PSV (11.9 ± 2, 12 ± 2, and 12.8 ± 3 cm/s at 3, 6, and 12 months, respectively) were significantly ( P < 0.001) lower after surgery in comparison with pre-surgical values (TAPSE: 25.3 ± 4 mm; PSV: 17.8 ± 4 cm/s). On the contrary, pre-operative RVEF (58.4 ± 4%) did not change after surgery (56.9 ± 5, 59.5 ± 5, and 58.5 ± 5% at each step). Despite the post-operative reduction of RV performance along the long axis suggested by TAPSE and PSV, the absence of a decrease in 3D RVEF leads to caution in the interpretation of these 2D and Doppler parameters after cardiac surgery, supporting the hypothesis of geometrical rather than functional changes in the right ventricle.
- 1 August 2008
- Published by Elsevier in The American Journal of Cardiology
- Vol. 102 (4) , 499-505
Feasibility of a New Generation Three-Dimensional Echocardiography for Right Ventricular Volumetric and Functional Measurements
- 1 August 2008
- Published by Elsevier in The American Journal of Cardiology
- Vol. 102 (4) , 499-505
Feasibility of a New Generation Three-Dimensional Echocardiography for Right Ventricular Volumetric and Functional Measurements
- 1 October 2006
- Published by Elsevier in The American Journal of Cardiology
- Vol. 98 (7) , 966-969
Comparison of Feasibility and Accuracy of Transthoracic Echocardiography Versus Computed Tomography in Patients With Known Ascending Aortic Aneurysm
- 1 October 2006
- Published by Elsevier in The American Journal of Cardiology
- Vol. 98 (7) , 966-969
Comparison of Feasibility and Accuracy of Transthoracic Echocardiography Versus Computed Tomography in Patients With Known Ascending Aortic Aneurysm
- 1 November 2003
- Vol. 4 (11) , 797-802
Usefulness of multiplane transesophageal echocardiography in the recognition of artifacts and normal anatomical variants that may mimic left atrial thrombi in patients with atrial fibrillation.
Transesophageal echocardiography (TEE) is the method of choice for the evaluation of the left atrium and of left atrial appendage (LAA) thrombosis. However, the anatomy of the left appendage is complex and reverberations from anatomical structures may create images and ghosting which mimic left atrial thrombosis. The purpose of this study was to investigate whether a systematic approach through TEE may facilitate the recognition of LAA anatomical variants and artifacts. One hundred and sixty-four consecutive patients scheduled for cardioversion of atrial fibrillation (study population) and 30 patients (control group) undergoing mitral valve surgery were submitted to TEE using a multiplane probe in order to obtain a systematic evaluation of the LAA. The number of LAA lobes and the presence of thrombi and artifacts were evaluated. The majority of the study patients had a bilobed (53.1%) or single-lobed (34.1%) LAA. Thrombi were identified in 6%. Artifacts were found in 38 cases (23.2%) and their position was localized precisely at a distance from the transducer which was twice that from the partition-bend between the left upper pulmonary vein and left appendage, suggesting a reverberation. No differences in echocardiographic parameters were found in patients with (group 1) or without (group 2) artifacts. Cardioversion was successful in a similar percentage of cases in the two groups (group 1 68%, group 2 76%) without complications. In controls, the percentages of a single-(33%) and bilobed (40%) left appendage were similar to those found in the study population. Artifacts were identified in 11 controls (37%); no thrombi were detected during surgical left appendage inspection in these cases. A systematic approach with multiplane TEE facilitates the evaluation of the LAA anatomy and the recognition of artifacts, thus reducing the likelihood of false positive or negative diagnoses of left appendage thrombi.
- 1 November 2003
- Vol. 4 (11) , 797-802
Usefulness of multiplane transesophageal echocardiography in the recognition of artifacts and normal anatomical variants that may mimic left atrial thrombi in patients with atrial fibrillation.
Transesophageal echocardiography (TEE) is the method of choice for the evaluation of the left atrium and of left atrial appendage (LAA) thrombosis. However, the anatomy of the left appendage is complex and reverberations from anatomical structures may create images and ghosting which mimic left atrial thrombosis. The purpose of this study was to investigate whether a systematic approach through TEE may facilitate the recognition of LAA anatomical variants and artifacts. One hundred and sixty-four consecutive patients scheduled for cardioversion of atrial fibrillation (study population) and 30 patients (control group) undergoing mitral valve surgery were submitted to TEE using a multiplane probe in order to obtain a systematic evaluation of the LAA. The number of LAA lobes and the presence of thrombi and artifacts were evaluated. The majority of the study patients had a bilobed (53.1%) or single-lobed (34.1%) LAA. Thrombi were identified in 6%. Artifacts were found in 38 cases (23.2%) and their position was localized precisely at a distance from the transducer which was twice that from the partition-bend between the left upper pulmonary vein and left appendage, suggesting a reverberation. No differences in echocardiographic parameters were found in patients with (group 1) or without (group 2) artifacts. Cardioversion was successful in a similar percentage of cases in the two groups (group 1 68%, group 2 76%) without complications. In controls, the percentages of a single-(33%) and bilobed (40%) left appendage were similar to those found in the study population. Artifacts were identified in 11 controls (37%); no thrombi were detected during surgical left appendage inspection in these cases. A systematic approach with multiplane TEE facilitates the evaluation of the LAA anatomy and the recognition of artifacts, thus reducing the likelihood of false positive or negative diagnoses of left appendage thrombi.