APArthur Prochazka

Arthur Prochazka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arthur Prochazka has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Passive Devices for Upper Limb Training

    by Marika Demers, Justin Rowe, Arthur Prochazka


  • Proprioceptor Models

    by Arthur Prochazka

  • Motor Neuroprostheses

    by Arthur Prochazka

    Neuroprostheses (NPs) are electrical stimulators that activate nerves, either to provide sensory input to the central nervous system (sensory NPs), or to activate muscles (motor NPs: MNPs). The first MNPs were belts with inbuilt batteries and electrodes developed in the 1850s to exercise the abdominal muscles. They became enormously popular among the general public, but as a result of exaggerated therapeutic claims they were soon discredited by the medical community. In the 1950s, MNPs reemerged for the serious purpose of activating paralyzed muscles. Neuromuscular electrical stimulation (NMES), when applied in a preset sequence, is called therapeutic electrical stimulation (TES). NMES timed so that it enhances muscle contraction in intended voluntary movements is called functional electrical stimulation (FES) or functional neuromuscular stimulation (FNS). It has been 50 years since the first FES device, a foot‐drop stimulator, was described and 40 years since the first implantable version was tested in humans. A commercial foot‐drop stimulator became available in the 1970s, but for various reasons, it failed to achieve widespread use. With advances in technology, such devices are now more convenient and reliable. Enhancing upper limb function is a more difficult task, but grasp‐release stimulators have been shown to provide significant benefits. This chapter deals with the technical aspects of NMES, the therapeutic and functional benefits of TES and FES, delayed‐onset and carryover effects attributable to “neuromodulation” and the barriers and opportunities in this rapidly developing field. © 2019 American Physiological Society. Compr Physiol 9:127‐148, 2019.


  • Neurophysiology and neural engineering: a review

    by Arthur Prochazka

    Neurophysiology is the branch of physiology concerned with understanding the function of neural systems. Neural engineering (also known as neuroengineering) is a discipline within biomedical engineering that uses engineering techniques to understand, repair, replace, enhance, or otherwise exploit the properties and functions of neural systems. In most cases neural engineering involves the development of an interface between electronic devices and living neural tissue. This review describes the origins of neural engineering, the explosive development of methods and devices commencing in the late 1950s, and the present-day devices that have resulted. The barriers to interfacing electronic devices with living neural tissues are many and varied, and consequently there have been numerous stops and starts along the way. Representative examples are discussed. None of this could have happened without a basic understanding of the relevant neurophysiology. I also consider examples of how neural engineering is repaying the debt to basic neurophysiology with new knowledge and insight.


  • Sensory control of normal movement and of movement aided by neural prostheses

    by Arthur Prochazka

    Signals from sensory receptors in muscles and skin enter the central nervous system (CNS), where they contribute to kinaesthesia and the generation of motor commands. Many lines of evidence indicate that sensory input from skin receptors, muscle spindles and Golgi tendon organs play the predominant role in this regard. Yet in spite of over 100 years of research on this topic, some quite fundamental questions remain unresolved. How does the CNS choose to use the ability to control muscle spindle sensitivity during voluntary movements? Do spinal reflexes contribute usefully to load compensation, given that the feedback gain must be quite low to avoid instability? To what extent do signals from skin stretch receptors contribute? This article provides a brief review of various theories, past and present, that address these questions. To what extent has the knowledge gained resulted in clinical applications? Muscles paralyzed as a result of spinal cord injury or stroke can be activated by electrical stimulation delivered by neuroprostheses. In practice, at most two or three sensors can be deployed on the human body, providing only a small fraction of the information supplied by the tens of thousands of sensory receptors in animals. Most of the neuroprostheses developed so far do not provide continuous feedback control. Instead, they switch from one state to another when signals from their one or two sensors meet pre‐set thresholds (finite state control). The inherent springiness of electrically activated muscle provides a crucial form of feedback control that helps smooth the resulting movements. In spite of the dissimilarities, parallels can be found between feedback control in neuroprostheses and in animals and this can provide surprising insights in both directions.


  • A Fully Automated, Quantitative Test of Upper Limb Function

    by Arthur Prochazka, Jan Kowalczewski

    The Rehabilitation Joystick for Computerized Exercise (ReJoyce, Rehabtronics Inc., Edmonton, Alberta, Canada), is a workstation on which participants exercise dexterous movement tasks in the guise of computer games. The system incorporates the ReJoyce Arm and Hand Function Test (RAHFT). Here the authors evaluate the RAHFT against the Action Research Arm Test (ARAT) and the Fugl-Meyer Assessment (FMA). All 3 tests were performed in 36 separate sessions in 13 tetraplegic individuals. Concurrent and criterion validities of the RAHFT were supported by a high level of correlation with the ARAT (r2 = .88). Regarding responsiveness, the effect size of the RAHFT at week 6 of 1 hr/day exercise training was 1.8. Regarding reliability, the mean test–retest difference in RAHFT baseline scores was 0.67% ± 3.6%, which was not statistically significant. The RAHFT showed less ceiling effect than either ARAT or FMA. These data help validate the RAHFT as a quantitative, automated alternative to the ARAT and FMA. The RAHFT is the first comprehensive test of arm and dexterous hand function that does not depend on human judgment. It offers a standardized, quantitative outcome evaluation, which can be performed not only in the clinic, but also in the participant's home, administered by a remote therapist over the Internet.