Ru-Qin Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ru-Qin Yu has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
G L Shen
6 shared publicationsGuo-Li Shen
State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemisty and Chemical Engineering, Institute for Chemometrics and Chemical Technology, Hunan University, Changsha 410082, PR China
6 shared publicationsZeng-Ping Chen
State Key Laboratory of Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, China
4 shared publicationsGuo-Dong Liu
College of Chemistry and Chemical Engineering, Institute for Chemometrics and Sensing Technology, Hunan University, Changsha 410082, PR China
3 shared publicationsJian-Hui Jiang
College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082, People's Republic of China
3 shared publications- Yang Li
Department of Internal Medicine and Radboud Center for Infectious Diseases, Radboud university medical center, Nijmegen, The Netherlands
3 shared publications
Latest Publications
- 1 November 2002
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 87 (1) , 190-195
Fluoroimmunosensing system using antigens immobilized on cellulose–paraffin matrix for Brucella melitensis antibody assay
- 1 November 2002
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 87 (1) , 190-195
Fluoroimmunosensing system using antigens immobilized on cellulose–paraffin matrix for Brucella melitensis antibody assay
- 3 September 2002
- Published by Wiley in Journal of Computational Chemistry
- Vol. 23 (14) , 1357-1365
Genetic training of network using chaos concept: Application to QSAR studies of vibration modes of tetrahedral halides
The chaotic dynamical system is introduced ingenetic algorithm to train ANN to formulate the CGANN algorithm. Logistic mapping as one of the most important chaotic dynamic mappings provides each new generation a high chance to hold GA's population diversity. This enhances the ability to overcome overfitting in training an ANN. The proposed CGANN has been used for QSAR studies to predict the tetrahedral modes (ν1(A1) and ν2(E)) of halides [MX4]ε. The frequencies predicted by QSAR were compared with those calculated by quantum chemistry methods including PM3, AM1, and MNDO/d. The possibility of improving the predictive ability of QSAR by including quantum chemistry parameters as feature variables has been investigated using tetrahedral tetrahalide examples. © 2002 Wiley Periodicals, Inc. J Comput Chem 14: 1357–1365, 2002
- 3 September 2002
- Published by Wiley in Journal of Computational Chemistry
- Vol. 23 (14) , 1357-1365
Genetic training of network using chaos concept: Application to QSAR studies of vibration modes of tetrahedral halides
The chaotic dynamical system is introduced ingenetic algorithm to train ANN to formulate the CGANN algorithm. Logistic mapping as one of the most important chaotic dynamic mappings provides each new generation a high chance to hold GA's population diversity. This enhances the ability to overcome overfitting in training an ANN. The proposed CGANN has been used for QSAR studies to predict the tetrahedral modes (ν1(A1) and ν2(E)) of halides [MX4]ε. The frequencies predicted by QSAR were compared with those calculated by quantum chemistry methods including PM3, AM1, and MNDO/d. The possibility of improving the predictive ability of QSAR by including quantum chemistry parameters as feature variables has been investigated using tetrahedral tetrahalide examples. © 2002 Wiley Periodicals, Inc. J Comput Chem 14: 1357–1365, 2002
- 2 April 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (5) , 623-628
Inner chromatogram projection (ICP) for resolution of GC-MS data with embedded chromatographic peaks
The chromatographic peak located inside another peak in the time direction is called an embedded or inner peak in contradistinction with the embedding peak, which is called an outer peak. The chemical components corresponding to inner and outer peaks are called inner and outer components, respectively. This special case of co-eluting chromatograms was investigated using chemometric approaches taking GC-MS as an example. A novel method, named inner chromatogram projection (ICP), for resolution of GC-MS data with embedded chromatographic peaks is derived. Orthogonal projection resolution is first utilized to obtain the chromatographic profile of the inner component. Projection of the two-way data matrix columnwise-normalized along the time direction to the normalized profile of the inner component found is subsequently performed to find the selective m/z points, if they exist, which represent the chromatogram of the outer component by itself. With the profiles obtained, the mass spectra can easily be found by means of a least-squares procedure. The results for both simulated data and real samples demonstrate that the proposed method is capable of achieving satisfactory resolution performance not affected by the shapes of chromatograms and the relative positions of the components involved.
- 2 April 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (5) , 623-628
Inner chromatogram projection (ICP) for resolution of GC-MS data with embedded chromatographic peaks
The chromatographic peak located inside another peak in the time direction is called an embedded or inner peak in contradistinction with the embedding peak, which is called an outer peak. The chemical components corresponding to inner and outer peaks are called inner and outer components, respectively. This special case of co-eluting chromatograms was investigated using chemometric approaches taking GC-MS as an example. A novel method, named inner chromatogram projection (ICP), for resolution of GC-MS data with embedded chromatographic peaks is derived. Orthogonal projection resolution is first utilized to obtain the chromatographic profile of the inner component. Projection of the two-way data matrix columnwise-normalized along the time direction to the normalized profile of the inner component found is subsequently performed to find the selective m/z points, if they exist, which represent the chromatogram of the outer component by itself. With the profiles obtained, the mass spectra can easily be found by means of a least-squares procedure. The results for both simulated data and real samples demonstrate that the proposed method is capable of achieving satisfactory resolution performance not affected by the shapes of chromatograms and the relative positions of the components involved.
- 25 February 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (4) , 512-517
N-Allyl-4-(N-2′-hydroxyethyl)amino-1,8-naphthalimide as a fluorophore for optical chemosensing of nitrofurantoin
N-Allyl-4-(N-2′-hydroxyethyl)amino-1,8-naphthalimide (AHEAN), a naphthalimide derivative, was synthesized as a new fluorophore for optical chemical sensor preparation. To prevent leakage of the fluorophore, AHEAN was photo-copolymerized with 2-hydroxypropyl methacrylate on a glass surface treated with a silanizing agent. An optical chemical sensor based on AHEAN can be utilized for nitrofurantoin assay based on fluorescence quenching. The sensor shows sufficient repeatability, selectivity and a fast response of less than 30 s. Nitrofurantoin can be determined in the range between 1.00 × 10−6 and 1.00 × 10−3 mol l−1 with a detection limit of 4.8 × 10−7 mol l−1. Most commonly co-existing drug substances and ions do not interfere with the nitrofurantoin assay. The sensor was applied to the analysis of pharmaceutical and urine samples.
- 25 February 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (4) , 512-517
N-Allyl-4-(N-2′-hydroxyethyl)amino-1,8-naphthalimide as a fluorophore for optical chemosensing of nitrofurantoin
N-Allyl-4-(N-2′-hydroxyethyl)amino-1,8-naphthalimide (AHEAN), a naphthalimide derivative, was synthesized as a new fluorophore for optical chemical sensor preparation. To prevent leakage of the fluorophore, AHEAN was photo-copolymerized with 2-hydroxypropyl methacrylate on a glass surface treated with a silanizing agent. An optical chemical sensor based on AHEAN can be utilized for nitrofurantoin assay based on fluorescence quenching. The sensor shows sufficient repeatability, selectivity and a fast response of less than 30 s. Nitrofurantoin can be determined in the range between 1.00 × 10−6 and 1.00 × 10−3 mol l−1 with a detection limit of 4.8 × 10−7 mol l−1. Most commonly co-existing drug substances and ions do not interfere with the nitrofurantoin assay. The sensor was applied to the analysis of pharmaceutical and urine samples.
- 1 November 2001
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 80 (2) , 95-100
Renewable amperometric immunosensor for complement 3 (C3) assay in human serum
- 1 November 2001
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 80 (2) , 95-100
Renewable amperometric immunosensor for complement 3 (C3) assay in human serum
- 1 August 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 370 (8) , 1029-1034
Renewable amperometric immunosensor for complement 3 assay based on the sol-gel technique.
- 1 August 2001
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 370 (8) , 1029-1034
Renewable amperometric immunosensor for complement 3 assay based on the sol-gel technique.
- 22 May 2001
- Published by Wiley in Journal of Chemometrics
- Vol. 15 (5) , 439-453
On the self‐weighted alternating trilinear decomposition algorithm—the property of being insensitive to excess factors used in calculation
PARAFAC is well known as an iterative trilinear decomposition method. In practice, an accurate estimation of the number of underlying factors is required; otherwise it is difficult to guarantee the chemical meaning of the results obtained. The absence of a versatile chemometric method for factor estimation has often caused problems for analysts. With the advent of ATLD followed by SWATLD, the above relatively strict constraint can be relaxed. Experiments have shown that the profiles of the underlying factors can be extracted by ATLD (Wu et al., J. Chemometrics 1998; 12: 1) and SWATLD (Chen et al., Chemometrics Intell. Lab. Syst. 2000; 52: 75) as long as the number of factors used in calculation is no less than the number of actual factors. In other words, an overestimation of the number of factors will not affect the obtainment of chemically meaningful results by SWATLD and ATLD. In this paper the authors provide some simple mathematical explanations of this valuable property of SWATLD. Along with these explanations, some other properties of SWATLD as well as some guidelines for designing new trilinear decomposition methods are also discussed. Copyright © 2001 John Wiley & Sons, Ltd.
- 22 May 2001
- Published by Wiley in Journal of Chemometrics
- Vol. 15 (5) , 439-453
On the self‐weighted alternating trilinear decomposition algorithm—the property of being insensitive to excess factors used in calculation
PARAFAC is well known as an iterative trilinear decomposition method. In practice, an accurate estimation of the number of underlying factors is required; otherwise it is difficult to guarantee the chemical meaning of the results obtained. The absence of a versatile chemometric method for factor estimation has often caused problems for analysts. With the advent of ATLD followed by SWATLD, the above relatively strict constraint can be relaxed. Experiments have shown that the profiles of the underlying factors can be extracted by ATLD (Wu et al., J. Chemometrics 1998; 12: 1) and SWATLD (Chen et al., Chemometrics Intell. Lab. Syst. 2000; 52: 75) as long as the number of factors used in calculation is no less than the number of actual factors. In other words, an overestimation of the number of factors will not affect the obtainment of chemically meaningful results by SWATLD and ATLD. In this paper the authors provide some simple mathematical explanations of this valuable property of SWATLD. Along with these explanations, some other properties of SWATLD as well as some guidelines for designing new trilinear decomposition methods are also discussed. Copyright © 2001 John Wiley & Sons, Ltd.
- 1 March 2001
- Published by Wiley in Journal of Chemometrics
- Vol. 15 (3) , 149-167
Pseudo alternating least squares algorithm for trilinear decomposition
- 1 March 2001
- Published by Wiley in Journal of Chemometrics
- Vol. 15 (3) , 149-167
Pseudo alternating least squares algorithm for trilinear decomposition
- 15 February 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (3) , 349-352
Picric acid sensitive optode based on a fluorescence carrier covalently bound to membrane
An acryloyl group was attached to fluorescein through the phenol hydroxyl group to make it photopolymerizable with 2-hydroxypropyl methacrylate and covalently immobilized on an optode glass surface modified with γ-(methacryloxy)propyltrimethoxysilane. The optode system with a plastic-clad fused silica bifurcated fiber optic bundle shows satisfactory analytical performance characteristics for determining picric acid in terms of selectivity and reproducibility with a linear range from 8.0 × 10−7 to 4.0 × 10−3 mol L−1. The quenching mechanism was investigated. The optode membrane can be applied to the indirect determination of cinchonine drug and the results obtained were satisfactory.
- 15 February 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (3) , 349-352
Picric acid sensitive optode based on a fluorescence carrier covalently bound to membrane
An acryloyl group was attached to fluorescein through the phenol hydroxyl group to make it photopolymerizable with 2-hydroxypropyl methacrylate and covalently immobilized on an optode glass surface modified with γ-(methacryloxy)propyltrimethoxysilane. The optode system with a plastic-clad fused silica bifurcated fiber optic bundle shows satisfactory analytical performance characteristics for determining picric acid in terms of selectivity and reproducibility with a linear range from 8.0 × 10−7 to 4.0 × 10−3 mol L−1. The quenching mechanism was investigated. The optode membrane can be applied to the indirect determination of cinchonine drug and the results obtained were satisfactory.
- 1 September 2000
- Published by Elsevier in Analytica Chimica Acta
- Vol. 419 (2) , 227-233
Fluoroborate ion sensitive PVC membrane electrode based on chloro[tetra(m-amino-phenyl)porphinato]-manganese as neutral carrier
- 1 September 2000
- Published by Elsevier in Analytica Chimica Acta
- Vol. 419 (2) , 227-233
Fluoroborate ion sensitive PVC membrane electrode based on chloro[tetra(m-amino-phenyl)porphinato]-manganese as neutral carrier