Elsa Lundanes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Elsa Lundanes has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
Tyge Greibrokk
Department of Chemistry, University of Oslo, Blindern, Oslo, Norway. Fax: +47‐22855441
7 shared publications- Steven Ray Wilson
University of Oslo
5 shared publications Steven Ray Wilson
4 shared publications- Ole Kristian Brandtzaeg
Department of Chemistry, University of Oslo, Oslo, Norway
3 shared publications Paal Molander
University of Oslo
3 shared publications- Line Roed
Department of Chemistry, University of Oslo, Norway
2 shared publications
Latest Publications
- Open Access
- 13 August 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (8) , 539
Tailored Polymer-Based Selective Extraction of Lipid Mediators from Biological Samples
Lipid mediators, small molecules involved in regulating inflammation and its resolution, are a class of lipids of wide interest as their levels in blood and tissues may be used to monitor health and disease states or the effect of new treatments. These molecules are present at low levels in biological samples, and an enrichment step is often needed for their detection. We describe a rapid and selective method that uses new low-cost molecularly imprinted (MIP) and non-imprinted (NIP) polymeric sorbents for the extraction of lipid mediators from plasma and tissue samples. The extraction process was carried out in solid-phase extraction (SPE) cartridges, manually packed with the sorbents. After extraction, lipid mediators were quantified by liquid chromatography–tandem mass spectrometry (LC–MSMS). Various parameters affecting the extraction efficiency were evaluated to achieve optimal recovery and to reduce non-specific interactions. Preliminary tests showed that MIPs, designed using the prostaglandin biosynthetic precursor arachidonic acid, could effectively enrich prostaglandins and structurally related molecules. However, for other lipid mediators, MIP and NIP displayed comparable recoveries. Under optimized conditions, the recoveries of synthetic standards ranged from 62% to 100%. This new extraction method was applied to the determination of the lipid mediators concentration in human plasma and mouse tissues and compared to other methods based on commercially available cartridges. In general, the methods showed comparable performances. In terms of structural specificity, our newly synthesized materials accomplished better retention of prostaglandins (PGs), hydroxydocosahexaenoic acid (HDoHE), HEPE, hydroxyeicosatetraenoic acids (HETE), hydroxyeicosatrienoic acid (HETrE), and polyunsaturated fatty acid (PUFA) compounds, while the commercially available Strata-X showed a higher recovery for dihydroxyeicosatetraenoic acid (diHETrEs). In summary, our results suggest that this new material can be successfully implemented for the extraction of lipid mediators from biological samples.
- 13 August 2021
- Published by MDPI AG in Metabolites
- Vol. 11 (8) , 539
Open AccessTailored Polymer-Based Selective Extraction of Lipid Mediators from Biological Samples
Lipid mediators, small molecules involved in regulating inflammation and its resolution, are a class of lipids of wide interest as their levels in blood and tissues may be used to monitor health and disease states or the effect of new treatments. These molecules are present at low levels in biological samples, and an enrichment step is often needed for their detection. We describe a rapid and selective method that uses new low-cost molecularly imprinted (MIP) and non-imprinted (NIP) polymeric sorbents for the extraction of lipid mediators from plasma and tissue samples. The extraction process was carried out in solid-phase extraction (SPE) cartridges, manually packed with the sorbents. After extraction, lipid mediators were quantified by liquid chromatography–tandem mass spectrometry (LC–MSMS). Various parameters affecting the extraction efficiency were evaluated to achieve optimal recovery and to reduce non-specific interactions. Preliminary tests showed that MIPs, designed using the prostaglandin biosynthetic precursor arachidonic acid, could effectively enrich prostaglandins and structurally related molecules. However, for other lipid mediators, MIP and NIP displayed comparable recoveries. Under optimized conditions, the recoveries of synthetic standards ranged from 62% to 100%. This new extraction method was applied to the determination of the lipid mediators concentration in human plasma and mouse tissues and compared to other methods based on commercially available cartridges. In general, the methods showed comparable performances. In terms of structural specificity, our newly synthesized materials accomplished better retention of prostaglandins (PGs), hydroxydocosahexaenoic acid (HDoHE), HEPE, hydroxyeicosatetraenoic acids (HETE), hydroxyeicosatrienoic acid (HETrE), and polyunsaturated fatty acid (PUFA) compounds, while the commercially available Strata-X showed a higher recovery for dihydroxyeicosatetraenoic acid (diHETrEs). In summary, our results suggest that this new material can be successfully implemented for the extraction of lipid mediators from biological samples.
- Open Access
- 1 March 2021
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 136
Recent advances in on-line upfront devices for sensitive bioanalytical nano LC methods
- 1 March 2021
- Published by Elsevier in TrAC Trends in Analytical Chemistry
- Vol. 136
Open AccessRecent advances in on-line upfront devices for sensitive bioanalytical nano LC methods
- Open Access
“Organ-in-a-column” coupled on-line with liquid chromatography-mass spectrometry
Organoids, i.e. laboratory-grown organ models developed from stem cells, are emerging tools for studying organ physiology, disease modeling and drug development. On-line analysis of organoids with mass spectrometry would provide analytical versatility and automation. To achieve these features with robust hardware, we have loaded liquid chromatography column housings with induced pluripotent stem cell (iPSC) derived liver organoids and coupled the “organ-in-a-column” units on-line with liquid chromatography-mass spectrometry (LC-MS). Liver organoids were co-loaded with glass beads to achieve an even distribution of organoids throughout the column while preventing clogging. The liver organoids were interrogated “on column” with heroin, followed by on-line monitoring of the drug’s phase 1 metabolism. Enzymatic metabolism of heroin produced in the “organ-in-a-column” units was detected and monitored using a triple quadrupole MS instrument, serving as a proof-of-concept for on-line coupling of liver organoids and mass spectrometry. Taken together, the technology allows direct integration of liver organoids with LC-MS, allowing selective and automated tracking of drug metabolism over time.
Open Access“Organ-in-a-column” coupled on-line with liquid chromatography-mass spectrometry
Organoids, i.e. laboratory-grown organ models developed from stem cells, are emerging tools for studying organ physiology, disease modeling and drug development. On-line analysis of organoids with mass spectrometry would provide analytical versatility and automation. To achieve these features with robust hardware, we have loaded liquid chromatography column housings with induced pluripotent stem cell (iPSC) derived liver organoids and coupled the “organ-in-a-column” units on-line with liquid chromatography-mass spectrometry (LC-MS). Liver organoids were co-loaded with glass beads to achieve an even distribution of organoids throughout the column while preventing clogging. The liver organoids were interrogated “on column” with heroin, followed by on-line monitoring of the drug’s phase 1 metabolism. Enzymatic metabolism of heroin produced in the “organ-in-a-column” units was detected and monitored using a triple quadrupole MS instrument, serving as a proof-of-concept for on-line coupling of liver organoids and mass spectrometry. Taken together, the technology allows direct integration of liver organoids with LC-MS, allowing selective and automated tracking of drug metabolism over time.
- 7 November 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (24) , 7090-7104
Nano liquid chromatography columns
Nano liquid chromatography (nanoLC), with columns having an inner diameter (ID) of ≤100 μm, can provide enhanced sensitivity and enable analysis of limited samples. NanoLC has become an established tool in omics research, and is gaining ground in other applications as well. There are several variants and formats of nanoLC columns, including packed columns, monoliths, open tubular columns, and the pillar array format. Most applications are done with packed columns, while e.g. the monolith and open tubular columns are still less established as routine tools. The pillar array format is a new variant with excellent resolution and low backpressure, and has recently been commercialized and used for bio-applications. In this minireview, we summarize and discuss recent research on nanoLC column development and uses, focusing on literature between 2016 and medio 2019.
- 7 November 2019
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 144 (24) , 7090-7104
Nano liquid chromatography columns
Nano liquid chromatography (nanoLC), with columns having an inner diameter (ID) of ≤100 μm, can provide enhanced sensitivity and enable analysis of limited samples. NanoLC has become an established tool in omics research, and is gaining ground in other applications as well. There are several variants and formats of nanoLC columns, including packed columns, monoliths, open tubular columns, and the pillar array format. Most applications are done with packed columns, while e.g. the monolith and open tubular columns are still less established as routine tools. The pillar array format is a new variant with excellent resolution and low backpressure, and has recently been commercialized and used for bio-applications. In this minireview, we summarize and discuss recent research on nanoLC column development and uses, focusing on literature between 2016 and medio 2019.
- 1 January 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1534, 195-200
Exploring bioimpendance instrumentation for the characterization of open tubular liquid chromatography columns
- 1 January 2018
- Published by Elsevier in Journal of Chromatography A
- Vol. 1534, 195-200
Exploring bioimpendance instrumentation for the characterization of open tubular liquid chromatography columns
- Open Access
- 1 May 2017
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 1 (6) , 637-648
Routine Supercritical Fluid Chromatography Tandem Mass Spectrometry Method for Determination of Vitamin K1 Extracted from Serum with a 96-Well Solid-Phase Extraction Method
Background: The concentration of vitamin K1 in serum or plasma is the most common index for assessing vitamin K status. The aim of this study was to develop and validate a rapid and reliable routine method for quantifying vitamin K1 above 0.1 ng/mL. Semi-automation of a simple sample preparation with fast analysis by supercritical fluid chromatography–tandem mass spectrometry (SFC-MS/MS) was exploited. Methods: Vitamin K1 was extracted from 250-μL serum samples by the use of protein precipitation and reversed-phase solid-phase extraction (SPE) in 96-well plates and quantified by SFC on a 2.1 × 100 mm Torus 1-Aminoanthracene (1-AA) column in 3.8 min with electrospray ionization—tandem mass spectrometry (MS/MS) detection. Results: This method shows good linearity in the concentration range of 0.1–50 ng/mL with a correlation coefficient of R2 >0.999. Imprecision was satisfactory, with repeatability and reproducibility 7 as internal standard. Recovery of vitamin K1 in external quality controls was satisfactory compared to other laboratories participating in the external quality assurance scheme. The method is currently in routine use for analysis of serum samples. Conclusions: The method allows high-throughput reliable determination of vitamin K1 in serum in the range 0.1–50 ng/mL.
- 1 May 2017
- Published by Oxford University Press (OUP) in The Journal of Applied Laboratory Medicine
- Vol. 1 (6) , 637-648
Open AccessRoutine Supercritical Fluid Chromatography Tandem Mass Spectrometry Method for Determination of Vitamin K1 Extracted from Serum with a 96-Well Solid-Phase Extraction Method
Background: The concentration of vitamin K1 in serum or plasma is the most common index for assessing vitamin K status. The aim of this study was to develop and validate a rapid and reliable routine method for quantifying vitamin K1 above 0.1 ng/mL. Semi-automation of a simple sample preparation with fast analysis by supercritical fluid chromatography–tandem mass spectrometry (SFC-MS/MS) was exploited. Methods: Vitamin K1 was extracted from 250-μL serum samples by the use of protein precipitation and reversed-phase solid-phase extraction (SPE) in 96-well plates and quantified by SFC on a 2.1 × 100 mm Torus 1-Aminoanthracene (1-AA) column in 3.8 min with electrospray ionization—tandem mass spectrometry (MS/MS) detection. Results: This method shows good linearity in the concentration range of 0.1–50 ng/mL with a correlation coefficient of R2 >0.999. Imprecision was satisfactory, with repeatability and reproducibility 7 as internal standard. Recovery of vitamin K1 in external quality controls was satisfactory compared to other laboratories participating in the external quality assurance scheme. The method is currently in routine use for analysis of serum samples. Conclusions: The method allows high-throughput reliable determination of vitamin K1 in serum in the range 0.1–50 ng/mL.
- Open Access
- 23 January 2017
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 127 (2) , 709-719
Kisspeptin modulates sexual and emotional brain processing in humans
BACKGROUND. Sex, emotion, and reproduction are fundamental and tightly entwined aspects of human behavior. At a population level in humans, both the desire for sexual stimulation and the desire to bond with a partner are important precursors to reproduction. However, the relationships between these processes are incompletely understood. The limbic brain system has key roles in sexual and emotional behaviors, and is a likely candidate system for the integration of behavior with the hormonal reproductive axis. We investigated the effects of kisspeptin, a recently identified key reproductive hormone, on limbic brain activity and behavior. METHODS. Using a combination of functional neuroimaging and hormonal and psychometric analyses, we compared the effects of kisspeptin versus vehicle administration in 29 healthy heterosexual young men. RESULTS. We demonstrated that kisspeptin administration enhanced limbic brain activity specifically in response to sexual and couple-bonding stimuli. Furthermore, kisspeptin’s enhancement of limbic brain structures correlated with psychometric measures of reward, drive, mood, and sexual aversion, providing functional significance. In addition, kisspeptin administration attenuated negative mood. CONCLUSIONS. Collectively, our data provide evidence of an undescribed role for kisspeptin in integrating sexual and emotional brain processing with reproduction in humans. These results have important implications for our understanding of reproductive biology and are highly relevant to the current pharmacological development of kisspeptin as a potential therapeutic agent for patients with common disorders of reproductive function. FUNDING. National Institute for Health Research (NIHR), Wellcome Trust (Ref 080268), and the Medical Research Council (MRC).
- 23 January 2017
- Published by American Society for Clinical Investigation in Journal of Clinical Investigation
- Vol. 127 (2) , 709-719
Open AccessKisspeptin modulates sexual and emotional brain processing in humans
BACKGROUND. Sex, emotion, and reproduction are fundamental and tightly entwined aspects of human behavior. At a population level in humans, both the desire for sexual stimulation and the desire to bond with a partner are important precursors to reproduction. However, the relationships between these processes are incompletely understood. The limbic brain system has key roles in sexual and emotional behaviors, and is a likely candidate system for the integration of behavior with the hormonal reproductive axis. We investigated the effects of kisspeptin, a recently identified key reproductive hormone, on limbic brain activity and behavior. METHODS. Using a combination of functional neuroimaging and hormonal and psychometric analyses, we compared the effects of kisspeptin versus vehicle administration in 29 healthy heterosexual young men. RESULTS. We demonstrated that kisspeptin administration enhanced limbic brain activity specifically in response to sexual and couple-bonding stimuli. Furthermore, kisspeptin’s enhancement of limbic brain structures correlated with psychometric measures of reward, drive, mood, and sexual aversion, providing functional significance. In addition, kisspeptin administration attenuated negative mood. CONCLUSIONS. Collectively, our data provide evidence of an undescribed role for kisspeptin in integrating sexual and emotional brain processing with reproduction in humans. These results have important implications for our understanding of reproductive biology and are highly relevant to the current pharmacological development of kisspeptin as a potential therapeutic agent for patients with common disorders of reproductive function. FUNDING. National Institute for Health Research (NIHR), Wellcome Trust (Ref 080268), and the Medical Research Council (MRC).
- Open Access
- 1 April 2015
- Published by PeerJ in PeerJ Preprints
Blood targeted proteomics: centrifugal filter sample preparation vs dilute-and-shoot
Blood has a complex proteome with a huge span of protein abundances, and we are currently exploring sample preparation strategies addressing this potential challenge. We first evaluated the possibility to simply reduce complexity by fractionating blood samples (prior to targeted proteomics), using combinations of centrifugal filters that are promoted as having differing molar mass (M M ) selectivity. However, systematic fractionation was not possible, as the units had surprisingly unpredictable M M filtration profiles. Hence, labeling implying M M selectivity of centrifugal filters shouldn’t be taken literally. One filter combination (100+50K) however appeared to reduce human serum albumin (HSA) compared with much of the proteome (assessed using gel electrophoresis and staining). However, for our target protein beta-catenin, a “dilute-and-shoot” approach (without any attempt to remove high abundant proteins) was what enabled identification of beta-catenin in blood with nano liquid chromatography mass spectrometry (nano-LC-MS). Thus, minimal sample preparation can be an option in targeted blood proteomics. All blood samples prepared and analyzed (using ultrafast nano-LC-MS) were of considerable complexity, and we document the importance of using external standard spiking and minimum three MS/MS transitions to confirm the presence of target proteins.
- 1 April 2015
- Published by PeerJ in PeerJ Preprints
Open AccessBlood targeted proteomics: centrifugal filter sample preparation vs dilute-and-shoot
Blood has a complex proteome with a huge span of protein abundances, and we are currently exploring sample preparation strategies addressing this potential challenge. We first evaluated the possibility to simply reduce complexity by fractionating blood samples (prior to targeted proteomics), using combinations of centrifugal filters that are promoted as having differing molar mass (M M ) selectivity. However, systematic fractionation was not possible, as the units had surprisingly unpredictable M M filtration profiles. Hence, labeling implying M M selectivity of centrifugal filters shouldn’t be taken literally. One filter combination (100+50K) however appeared to reduce human serum albumin (HSA) compared with much of the proteome (assessed using gel electrophoresis and staining). However, for our target protein beta-catenin, a “dilute-and-shoot” approach (without any attempt to remove high abundant proteins) was what enabled identification of beta-catenin in blood with nano liquid chromatography mass spectrometry (nano-LC-MS). Thus, minimal sample preparation can be an option in targeted blood proteomics. All blood samples prepared and analyzed (using ultrafast nano-LC-MS) were of considerable complexity, and we document the importance of using external standard spiking and minimum three MS/MS transitions to confirm the presence of target proteins.
- Open Access
- 1 April 2015
- Published by PeerJ in PeerJ Preprints
Blood targeted proteomics: centrifugal filter sample preparation vs dilute-and-shoot
Blood has a complex proteome with a huge span of protein abundances, and we are currently exploring sample preparation strategies addressing this potential challenge. We first evaluated the possibility to simply reduce complexity by fractionating blood samples (prior to targeted proteomics), using combinations of centrifugal filters that are promoted as having differing molar mass (M M ) selectivity. However, systematic fractionation was not possible, as the units had surprisingly unpredictable M M filtration profiles. Hence, labeling implying M M selectivity of centrifugal filters shouldn’t be taken literally. One filter combination (100+50K) however appeared to reduce human serum albumin (HSA) compared with much of the proteome (assessed using gel electrophoresis and staining). However, for our target protein beta-catenin, a “dilute-and-shoot” approach (without any attempt to remove high abundant proteins) was what enabled identification of beta-catenin in blood with nano liquid chromatography mass spectrometry (nano-LC-MS). Thus, minimal sample preparation can be an option in targeted blood proteomics. All blood samples prepared and analyzed (using ultrafast nano-LC-MS) were of considerable complexity, and we document the importance of using external standard spiking and minimum three MS/MS transitions to confirm the presence of target proteins.
- 1 April 2015
- Published by PeerJ in PeerJ Preprints
Open AccessBlood targeted proteomics: centrifugal filter sample preparation vs dilute-and-shoot
Blood has a complex proteome with a huge span of protein abundances, and we are currently exploring sample preparation strategies addressing this potential challenge. We first evaluated the possibility to simply reduce complexity by fractionating blood samples (prior to targeted proteomics), using combinations of centrifugal filters that are promoted as having differing molar mass (M M ) selectivity. However, systematic fractionation was not possible, as the units had surprisingly unpredictable M M filtration profiles. Hence, labeling implying M M selectivity of centrifugal filters shouldn’t be taken literally. One filter combination (100+50K) however appeared to reduce human serum albumin (HSA) compared with much of the proteome (assessed using gel electrophoresis and staining). However, for our target protein beta-catenin, a “dilute-and-shoot” approach (without any attempt to remove high abundant proteins) was what enabled identification of beta-catenin in blood with nano liquid chromatography mass spectrometry (nano-LC-MS). Thus, minimal sample preparation can be an option in targeted blood proteomics. All blood samples prepared and analyzed (using ultrafast nano-LC-MS) were of considerable complexity, and we document the importance of using external standard spiking and minimum three MS/MS transitions to confirm the presence of target proteins.
- 2 September 2011
- Published by Elsevier in Journal of Chromatography A
- Vol. 1218 (35) , 5981-5986
Hydrophilic interaction chromatography of nucleoside triphosphates with temperature as a separation parameter
- 2 September 2011
- Published by Elsevier in Journal of Chromatography A
- Vol. 1218 (35) , 5981-5986
Hydrophilic interaction chromatography of nucleoside triphosphates with temperature as a separation parameter