Jin-Gou Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jin-Gou Xu has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
Hong Zheng
Department of Chemistry, Key Laboratory of Analytical Science of MOE, Xiamen University, Xiamen 361005, China
19 shared publicationsDong-Hui Li
Cancer Research Center of School of Life Science, Xiamen University
18 shared publicationsQing-Zhi Zhu
The Key Laboratory of Analytical Science of MOE, Department of Chemistry, Xiamen University, Xiamen 361005, People's Republic of China
13 shared publicationsHuang-Hao Yang
Department of Chemistry, Key Laboratory of Analytical Science of MOE, Xiamen University, Xiamen 361005, China
11 shared publicationsXiao-Lan Chen
The Key Laboratory of Analytical Science of MOE, Department of Chemistry, Xiamen University, Xiamen 361005, People's Republic of China
6 shared publicationsChang-Qing Zhu
The Key Laboratory of Analytical Science of MOE and Department of Chemistry, Xiamen University, Xiamen 361005, People's Republic of China
5 shared publications
Latest Publications
- 19 May 2009
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 28,p. 4179-4181
Enhanced fluorescence sensing of hydroxylated organotins by a boronic acid-linked Schiff base
A simple Schiff base, 2-(2′,4′-dihydroxybenzylidene)aminobenzeneboronic acid, was found to show a fluorescence enhancement in the presence of hydroxylated organotins in aqueous solution.
- 19 May 2009
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 28,p. 4179-4181
Enhanced fluorescence sensing of hydroxylated organotins by a boronic acid-linked Schiff base
A simple Schiff base, 2-(2′,4′-dihydroxybenzylidene)aminobenzeneboronic acid, was found to show a fluorescence enhancement in the presence of hydroxylated organotins in aqueous solution.
- 23 January 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 134 (3) , 443-446
Pb4Br113− cluster as a fluorescent indicator for micro water content in aprotic organic solvents
Micro water content in aprotic solvents can be conveniently determined from the Stokes' shift value of the fluorescent anionic Pb4Br11 3 −clusterin situ formed in the test solvents.
- 23 January 2009
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 134 (3) , 443-446
Pb4Br113− cluster as a fluorescent indicator for micro water content in aprotic organic solvents
Micro water content in aprotic solvents can be conveniently determined from the Stokes' shift value of the fluorescent anionic Pb4Br11 3 −clusterin situ formed in the test solvents.
- 10 March 2008
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 16,p. 1859-1861
Rhodamine thiospirolactone. Highly selective and sensitive reversible sensing of Hg(ii)
A novel rhodamine thiospirolactone chemosensor 1 was found to develop prominent absorbance and fluorescence enhancements in the presence of Hg2+ in aqueous solution and this was suggested to result from the thiospiro ring opening induced by Hg2+ binding.
- 10 March 2008
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 16,p. 1859-1861
Rhodamine thiospirolactone. Highly selective and sensitive reversible sensing of Hg(ii)
A novel rhodamine thiospirolactone chemosensor 1 was found to develop prominent absorbance and fluorescence enhancements in the presence of Hg2+ in aqueous solution and this was suggested to result from the thiospiro ring opening induced by Hg2+ binding.
- 1 August 2006
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 50 (7) , 894-895
Dose-dependent hypotension mainly results from epinephrine rather than lidocaine: lidocaine is only a pre-condition under some circumstances
- 1 August 2006
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 50 (7) , 894-895
Dose-dependent hypotension mainly results from epinephrine rather than lidocaine: lidocaine is only a pre-condition under some circumstances
- 1 March 2005
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 23 (3) , 285-290
A Novel Fluorescence Immunoassay System Based on pH-Sensitive Phase Separating Technique
- 1 March 2005
- Published by Wiley in Chinese Journal of Chemistry
- Vol. 23 (3) , 285-290
A Novel Fluorescence Immunoassay System Based on pH-Sensitive Phase Separating Technique
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (9) , 1793-1809
A Novel Flow‐Injection Analysis Method of Glucose Based on Template‐Synthesized Sol–Gel Nanotube Array Enzyme Membrane Reactor
A synthetic enzyme‐loading nanotube membrane was developed and used in flow‐injection analysis (FIA) for the first time. The membrane was based on an anodic alumina oxide (AAO) film that has cylindrical pores with monodisperse nanoscopic diameters, and silica nanotubes (SNTs) were chemically synthesized within the pores of this film through sol–gel chemistry. Horseradish peroxidase (HRP) was immobilized on the inner walls of the SNTs. The fabrication and initial testing of a flow‐through membrane reactor design for heterogeneous enzyme reactions were presented and applied to the determination of glucose in real samples. This novel immobilized enzyme membrane reactor possesses some advantages over both open‐tubular and packed‐bed reactors often used in FIA. The present work shows that the membrane containing SNTs offers considerable potential and new perspectives for the use of such nanomaterials.
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (9) , 1793-1809
A Novel Flow‐Injection Analysis Method of Glucose Based on Template‐Synthesized Sol–Gel Nanotube Array Enzyme Membrane Reactor
A synthetic enzyme‐loading nanotube membrane was developed and used in flow‐injection analysis (FIA) for the first time. The membrane was based on an anodic alumina oxide (AAO) film that has cylindrical pores with monodisperse nanoscopic diameters, and silica nanotubes (SNTs) were chemically synthesized within the pores of this film through sol–gel chemistry. Horseradish peroxidase (HRP) was immobilized on the inner walls of the SNTs. The fabrication and initial testing of a flow‐through membrane reactor design for heterogeneous enzyme reactions were presented and applied to the determination of glucose in real samples. This novel immobilized enzyme membrane reactor possesses some advantages over both open‐tubular and packed‐bed reactors often used in FIA. The present work shows that the membrane containing SNTs offers considerable potential and new perspectives for the use of such nanomaterials.
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (6) , 1115-1127
Near‐Infrared Fluorometric Determination of Protein by Shifting the Ion‐Association Equilibrium Between Cationic Heptamethylene Cyanine and Poly‐glutamate
A new method based on near‐infrared (near‐IR) fluorescence recovery, employing a two‐reagent system, which is composed of a cationic heptamethylene cyanine and poly‐glutamate, is presented for the determination of protein. The fluorescence of cationic heptamethylene cyanine, with the maximum excitation and emission wavelengths at 800 and 815 nm, respectively, was quenched by poly‐glutamate with a proper concentration, but recovered by adding proteins at pH 3.5. Under optimum conditions, the recovered fluorescence was in proportional to the concentration of proteins. The linear ranges of the calibration curves were 50–1000, 100–1500 and 100–1000 ng/mL with the detection limit of 37, 40, 43 ng/mL for BSA, HSA, and γ‐IgG, respectively. The relative standard deviation (n = 8) was 1.7% for 400 ng/mL bovine serum albumin (BSA). The proposed method was applied to the determination of proteins in real serum samples with satisfactory results.
- 28 December 2004
- Published by Taylor & Francis in Analytical Letters
- Vol. 37 (6) , 1115-1127
Near‐Infrared Fluorometric Determination of Protein by Shifting the Ion‐Association Equilibrium Between Cationic Heptamethylene Cyanine and Poly‐glutamate
A new method based on near‐infrared (near‐IR) fluorescence recovery, employing a two‐reagent system, which is composed of a cationic heptamethylene cyanine and poly‐glutamate, is presented for the determination of protein. The fluorescence of cationic heptamethylene cyanine, with the maximum excitation and emission wavelengths at 800 and 815 nm, respectively, was quenched by poly‐glutamate with a proper concentration, but recovered by adding proteins at pH 3.5. Under optimum conditions, the recovered fluorescence was in proportional to the concentration of proteins. The linear ranges of the calibration curves were 50–1000, 100–1500 and 100–1000 ng/mL with the detection limit of 37, 40, 43 ng/mL for BSA, HSA, and γ‐IgG, respectively. The relative standard deviation (n = 8) was 1.7% for 400 ng/mL bovine serum albumin (BSA). The proposed method was applied to the determination of proteins in real serum samples with satisfactory results.
- 2 December 2004
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 4,p. 450-452
A cyclometalated palladium–azo complex as a differential chromogenic probe for amino acids in aqueous solution
Solutions of a cyclometalated palladium–azo complex exhibited differential UV-Vis absorption spectra in the presence of α-amino acids with different side chain groups.
- 2 December 2004
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- No. 4,p. 450-452
A cyclometalated palladium–azo complex as a differential chromogenic probe for amino acids in aqueous solution
Solutions of a cyclometalated palladium–azo complex exhibited differential UV-Vis absorption spectra in the presence of α-amino acids with different side chain groups.
- 26 November 2004
- Published by Springer Nature in Microchimica Acta
- Vol. 148 (3-4) , 251-257
Determination of Nucleic Acids Based on Shifting the Association Equilibrium between a Heptamethine Cyanine Dye and Poly-Lysine
- 26 November 2004
- Published by Springer Nature in Microchimica Acta
- Vol. 148 (3-4) , 251-257
Determination of Nucleic Acids Based on Shifting the Association Equilibrium between a Heptamethine Cyanine Dye and Poly-Lysine