Mitsuko Oshima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mitsuko Oshima has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Shoji Motomizu
Department of Chemistry, Faculty of Science, Okayama University, 3-1-1 Tsushimanaka, Okayama 700-8530, Japan
18 shared publications - Toshio Takayanagi
Graduate School of Technology, Industrial and Social Sciences, Tokushima University
8 shared publications Shoji Motomizu
Department of Chemistry, Faculty of Science, Okayama University, 3-1-1 Tsushimanaka, Okayama 700-8530, Japan
6 shared publications- Akhmad Sabarudin
Department of Chemistry, Faculty of Science, Brawijaya University, Malang, Indonesia
4 shared publications Kyoji Tôei
3 shared publicationsKoji Oshita
Department of Chemistry, Faculty of Science, Okayama University, 3-1-1 Tsushimanaka, Okayama 700-8530, Japan
2 shared publications
Latest Publications
- 1 January 2006
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 55 (9) , 707-713
Development of Computer-Controlled Flow Injection Instruments and Its Application to Determination of Nitrate, Nitrite, and Ammonium Ions in Environmental Samples
Flow injection analysis (FIA) systems with low power consumption and personal-computer control were developed by using solenoid pumps and an LED detector. Both programs for controlling the system and acquiring measurement data were written using LabVIEW. The FIA system was applied to the determination of nitrite ion in river-water samples based on diazotization and coupling reactions. Linear calibration graphs were obtained with the combination of pump(s) and photometric detector in the concentration range of nitrite ion at 0.5∼3.0 × 10−6 M. Nitrate and nitrite ions were also determined simultaneously by the system by using a Cd/Cu reduction column and a by-pass flow. Determination of ammonia in river-water samples was also realized by the system with a modified indophenol reaction
- 1 January 2006
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 55 (9) , 707-713
Development of Computer-Controlled Flow Injection Instruments and Its Application to Determination of Nitrate, Nitrite, and Ammonium Ions in Environmental Samples
Flow injection analysis (FIA) systems with low power consumption and personal-computer control were developed by using solenoid pumps and an LED detector. Both programs for controlling the system and acquiring measurement data were written using LabVIEW. The FIA system was applied to the determination of nitrite ion in river-water samples based on diazotization and coupling reactions. Linear calibration graphs were obtained with the combination of pump(s) and photometric detector in the concentration range of nitrite ion at 0.5∼3.0 × 10−6 M. Nitrate and nitrite ions were also determined simultaneously by the system by using a Cd/Cu reduction column and a by-pass flow. Determination of ammonia in river-water samples was also realized by the system with a modified indophenol reaction
- 1 January 2006
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 55 (9) , 715-720
Highly Efficient and Automatic Collection/Concentration with Chelating Resin for Inductively Coupled Plasma Atomic Emission Spectroscopy
An automatically controlled collection/concentration system for ICP-AES was developed. Elements were collected with small chelating disks and chelating resin with the iminodiacetate moiety packed in a line filter. This column was installed in a 6-way valve on the pretreatment system, which could be connected on line to ICP-AES. The flow rate was 1 ml min−1 and conditioning of the chelating disk was carried out by flowing 0.5 M ammonium acetate (pH 5.5) for 2 min, sampling for 5 min and washing for 1 min. Elution was done by passing through 2 M HNO3 at 1.3 ml min−1 for 1 min. Bi, Cd, Co, Cr, Cu, Mn, Ni, Pb and V could be determined with 5.0 ml of the sample solution. The enrichment factors were 3∼15 times and the collection efficiencies were better than 80%. The detection limits (LOD) were from 0.003 for Mn to 0.311 for Bi, which were several 10 to 100-times lower than that of normal LOD of ICP-AES. This method was successfully applied to the determination of these metals in tap and river-water samples
- 1 January 2006
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 55 (9) , 715-720
Highly Efficient and Automatic Collection/Concentration with Chelating Resin for Inductively Coupled Plasma Atomic Emission Spectroscopy
An automatically controlled collection/concentration system for ICP-AES was developed. Elements were collected with small chelating disks and chelating resin with the iminodiacetate moiety packed in a line filter. This column was installed in a 6-way valve on the pretreatment system, which could be connected on line to ICP-AES. The flow rate was 1 ml min−1 and conditioning of the chelating disk was carried out by flowing 0.5 M ammonium acetate (pH 5.5) for 2 min, sampling for 5 min and washing for 1 min. Elution was done by passing through 2 M HNO3 at 1.3 ml min−1 for 1 min. Bi, Cd, Co, Cr, Cu, Mn, Ni, Pb and V could be determined with 5.0 ml of the sample solution. The enrichment factors were 3∼15 times and the collection efficiencies were better than 80%. The detection limits (LOD) were from 0.003 for Mn to 0.311 for Bi, which were several 10 to 100-times lower than that of normal LOD of ICP-AES. This method was successfully applied to the determination of these metals in tap and river-water samples
- 7 March 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 532 (1) , 27-35
Slope comparison method (SCM) for the determination of trace amounts of silicate in ultrapurified water
- 7 March 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 532 (1) , 27-35
Slope comparison method (SCM) for the determination of trace amounts of silicate in ultrapurified water
- Open Access
- 1 January 2004
- Published by Springer Nature in Analytical Sciences
- Vol. 20 (1) , 113-118
On-Line Collection/Concentration and Detection of Sulfur Dioxide in Air by Flow-Injection Spectrophotometry Coupled with a Chromatomembrane Cell
A simple and rapid procedure for SO2 determination in air was developed by using a flow injection analysis (FIA) system coupled with a 3-hole chromatomembrane cell (CMC). The CMC was applied for the on-line collection/concentration of SO2 from air into a solution of 2 g l-1 triethanolamine (TEA) solution as an absorbing solution: SO2 was converted to SO32- in the alkaline absorbing solution. The solution containing absorbed SO2 was introduced into the carrier stream of the FIA system. The amount of SO32- in the absorbing solution was measured by spectrophotometry with a mixed reagent of pararosaniline and formaldehyde, and was converted to the concentration of SO2 in the air sample. A calibration graph prepared by using standard sodium sulfite aqueous solutions was adopted for the determination of SO3-2 in the absorbing solution. The SO2 concentration in indoor air examined was found to be 22.7 ± 0.2 ppbv using 20 ml of air sample with the air flow rate of 5 ml min-1, where the relative standard deviation was 1.7%. The detection limit for aqueous solutions and air samples were 6.9 × 10-8 M and 0.48 ppbv, respectively. The measuring time for one sample was about 10 min when a 20 ml air sample was used. The interferences from common anionic species, formaldehyde and acetaldehyde, were also examined.
- 1 January 2004
- Published by Springer Nature in Analytical Sciences
- Vol. 20 (1) , 113-118
Open AccessOn-Line Collection/Concentration and Detection of Sulfur Dioxide in Air by Flow-Injection Spectrophotometry Coupled with a Chromatomembrane Cell
A simple and rapid procedure for SO2 determination in air was developed by using a flow injection analysis (FIA) system coupled with a 3-hole chromatomembrane cell (CMC). The CMC was applied for the on-line collection/concentration of SO2 from air into a solution of 2 g l-1 triethanolamine (TEA) solution as an absorbing solution: SO2 was converted to SO32- in the alkaline absorbing solution. The solution containing absorbed SO2 was introduced into the carrier stream of the FIA system. The amount of SO32- in the absorbing solution was measured by spectrophotometry with a mixed reagent of pararosaniline and formaldehyde, and was converted to the concentration of SO2 in the air sample. A calibration graph prepared by using standard sodium sulfite aqueous solutions was adopted for the determination of SO3-2 in the absorbing solution. The SO2 concentration in indoor air examined was found to be 22.7 ± 0.2 ppbv using 20 ml of air sample with the air flow rate of 5 ml min-1, where the relative standard deviation was 1.7%. The detection limit for aqueous solutions and air samples were 6.9 × 10-8 M and 0.48 ppbv, respectively. The measuring time for one sample was about 10 min when a 20 ml air sample was used. The interferences from common anionic species, formaldehyde and acetaldehyde, were also examined.
- 7 November 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (12) , 1713-1719
Development of column-pretreatment chelating resins for matrix elimination/multi-element determination by inductively coupled plasma-mass spectrometry
Chelating resins, two kinds of iminodiacetate derivatives (IDA) of cross-linked chitosan (CCS) were synthesized and investigated for adsorption capacity, matrix elimination and collection/concentration of analytes by a column pretreatment in a multi-element ICP-MS determination method. The adsorption behavior of 54 elements at the 10 ng ml−1 level on chitosan derivatives in a packed mini-column was systematically examined. Almost 30 kinds of metal ions were recovered quantitatively at pH 5 with CCS–HP/IDA (cross-linked chitosan possessing N-2-hydroxypropyl iminodiacetic acid groups) column. Compared with available chitosan–iminodiacetate resin, CHITOPEARL CI-03, the recovery of the metal ions such as Cu, Pb and La is satisfactory with CCS–IDA (cross-linked chitosan possessing N,N-iminodiacetic acid groups) and CCS–HP/IDA using 2 M nitric acid as an eluent, which may be attributed to the difference of cross-linking and macroporous structure. Compared with Chelex-100, the adsorption efficiency is in the order: Chelex-100 > CCS–IDA > CCS–HP/IDA, especially in the chelating ability for alkaline earth metals. The resin with a longer spacer (CCS–HP/IDA) showed higher adsorption selectivity between heavy metal ions and alkaline earth metals at pH < 7. The separation efficiency of the major matrix cations in seawater (Na, K, Mg, Ca) has also been investigated, and matrix interference was negligible even in a seawater sample at pH 5 with CCS–HP/IDA. The recoveries of Mn at pH 5 with CCS–HP/IDA or Chelex-100 were almost 100%. However, those of Mg with each resin were 4 or 98%, respectively. The adsorption capacities of synthesized CCS–HP/IDA for Cu(II), Pb(II) and La(III) were 0.90, 0.65 and 0.34 mmol g−1, respectively. Therefore, the chelating chitosan resins developed are applicable to the pretreatment of trace amounts of elements in various kinds of water samples.
- 7 November 2002
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 127 (12) , 1713-1719
Development of column-pretreatment chelating resins for matrix elimination/multi-element determination by inductively coupled plasma-mass spectrometry
Chelating resins, two kinds of iminodiacetate derivatives (IDA) of cross-linked chitosan (CCS) were synthesized and investigated for adsorption capacity, matrix elimination and collection/concentration of analytes by a column pretreatment in a multi-element ICP-MS determination method. The adsorption behavior of 54 elements at the 10 ng ml−1 level on chitosan derivatives in a packed mini-column was systematically examined. Almost 30 kinds of metal ions were recovered quantitatively at pH 5 with CCS–HP/IDA (cross-linked chitosan possessing N-2-hydroxypropyl iminodiacetic acid groups) column. Compared with available chitosan–iminodiacetate resin, CHITOPEARL CI-03, the recovery of the metal ions such as Cu, Pb and La is satisfactory with CCS–IDA (cross-linked chitosan possessing N,N-iminodiacetic acid groups) and CCS–HP/IDA using 2 M nitric acid as an eluent, which may be attributed to the difference of cross-linking and macroporous structure. Compared with Chelex-100, the adsorption efficiency is in the order: Chelex-100 > CCS–IDA > CCS–HP/IDA, especially in the chelating ability for alkaline earth metals. The resin with a longer spacer (CCS–HP/IDA) showed higher adsorption selectivity between heavy metal ions and alkaline earth metals at pH < 7. The separation efficiency of the major matrix cations in seawater (Na, K, Mg, Ca) has also been investigated, and matrix interference was negligible even in a seawater sample at pH 5 with CCS–HP/IDA. The recoveries of Mn at pH 5 with CCS–HP/IDA or Chelex-100 were almost 100%. However, those of Mg with each resin were 4 or 98%, respectively. The adsorption capacities of synthesized CCS–HP/IDA for Cu(II), Pb(II) and La(III) were 0.90, 0.65 and 0.34 mmol g−1, respectively. Therefore, the chelating chitosan resins developed are applicable to the pretreatment of trace amounts of elements in various kinds of water samples.
- 1 January 2002
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 51 (9) , 791-795
Determination of trace metal impurities in nickel and iron salts using 2-(5-Nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropyl-amino) phenol by capillary zone electrophoresis.
2-(5-Nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol (Nitro-PAPS) was used for a quantitative determination of ultratrace-level metal ions in commercially available metal salts by capillary zone electrophoresis. At pH 7, Nitro-PAPS reacts with various metal ions to form chelate compounds having large molar absorptivities. Although chelate formation is useful for the highly sensitive detection of metal ions, the resolution of the metal complexes is poor at pH 7. Cetyltrimethylammonium bromide was added to suppress any electroosmotic flow. The hydration of nitro groups of a chelating agent and chelates was controlled by the addition of urea. Sodium sulfate was also utilized to sharpen the signals of metal chelates by a field-enhanced stacking effect. As a result, the resolution was improved and the determination of 10-7 M level metal ions was possible. The proposed method was applied to the analysis of metal impurity at ultratrace levels in commercially available nickel and iron salts.市販金属塩中の極微量金属不純物の定量法として, 2-(5-ニトロ-2-ピリジルアゾ)-5-(N-プロピル-N-スルホプロピルアミノ)フェノール (Nitro-PAPS) とのキレートを分離, 検出するキャピラリー電気泳動法について検討した. 各種金属イオンと定量的に反応するpH7の条件では, 高感度検出が可能であるが, 多くの金属錯体の分離は十分でない. そこで, 電気浸透流やキレートの電気泳動移動度を変化させる効果のある第四級アンモニウム塩等の添加を検討し, 種々な相互作用試薬を用いて分離の改善を図った. その結果, 臭化セチルトリメチルアンモニウムの添加で電気浸透流が抑制され, 硫酸ナトリウムの添加によるスタッキング効果の活用によりシグナルが鋭敏化され, 尿素の添加でニトロ基周りの水和を抑制したところ, 金属キレートの分離性能が向上した. 本法により10(-7)MレベルのFe, Co, Ni, Cuの分離定量が可能になり, 市販特級金属塩中の極微量金属の分析に適用したところ, ppm (=10(-6)g/g) レベルの金属不純物を定量することができた
- 1 January 2002
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 51 (9) , 791-795
Determination of trace metal impurities in nickel and iron salts using 2-(5-Nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropyl-amino) phenol by capillary zone electrophoresis.
2-(5-Nitro-2-pyridylazo)-5-(N-propyl-N-sulfopropylamino)phenol (Nitro-PAPS) was used for a quantitative determination of ultratrace-level metal ions in commercially available metal salts by capillary zone electrophoresis. At pH 7, Nitro-PAPS reacts with various metal ions to form chelate compounds having large molar absorptivities. Although chelate formation is useful for the highly sensitive detection of metal ions, the resolution of the metal complexes is poor at pH 7. Cetyltrimethylammonium bromide was added to suppress any electroosmotic flow. The hydration of nitro groups of a chelating agent and chelates was controlled by the addition of urea. Sodium sulfate was also utilized to sharpen the signals of metal chelates by a field-enhanced stacking effect. As a result, the resolution was improved and the determination of 10-7 M level metal ions was possible. The proposed method was applied to the analysis of metal impurity at ultratrace levels in commercially available nickel and iron salts.市販金属塩中の極微量金属不純物の定量法として, 2-(5-ニトロ-2-ピリジルアゾ)-5-(N-プロピル-N-スルホプロピルアミノ)フェノール (Nitro-PAPS) とのキレートを分離, 検出するキャピラリー電気泳動法について検討した. 各種金属イオンと定量的に反応するpH7の条件では, 高感度検出が可能であるが, 多くの金属錯体の分離は十分でない. そこで, 電気浸透流やキレートの電気泳動移動度を変化させる効果のある第四級アンモニウム塩等の添加を検討し, 種々な相互作用試薬を用いて分離の改善を図った. その結果, 臭化セチルトリメチルアンモニウムの添加で電気浸透流が抑制され, 硫酸ナトリウムの添加によるスタッキング効果の活用によりシグナルが鋭敏化され, 尿素の添加でニトロ基周りの水和を抑制したところ, 金属キレートの分離性能が向上した. 本法により10(-7)MレベルのFe, Co, Ni, Cuの分離定量が可能になり, 市販特級金属塩中の極微量金属の分析に適用したところ, ppm (=10(-6)g/g) レベルの金属不純物を定量することができた
- Open Access
- 9 November 2001
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (11) , 1285-1290
Highly Sensitive Determination Method for Total Carbonate in Water Samples by Flow Injection Analysis Coupled with Gas-Diffusion Separation
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 9 November 2001
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (11) , 1285-1290
Open AccessHighly Sensitive Determination Method for Total Carbonate in Water Samples by Flow Injection Analysis Coupled with Gas-Diffusion Separation
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies