Cheng-Huang Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Cheng-Huang Lin has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
Ju-Tsung Liu
9 shared publicationsAn-Kai Su
Department of Chemistry, National Taiwan Normal University, 88 Sec. 4 Tingchow Road, Taipei, Taiwan
4 shared publicationsChing Fang
4 shared publicationsChun-Min Shih
Department of Chemistry, National Taiwan Normal University
4 shared publicationsJu‐Tsung Liu
Forensic Science Center, Command of the Army Force of Military Police, Department of Defense, Taipei, Taiwan
4 shared publicationsShiu-Huey Chou
Department of Life Science, Fu-Jen University, 510 Chung Cheng Road, Hsinchuang, Taipei Hsien 24205, Taiwan
4 shared publications
Latest Publications
- 1 January 2015
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 375, 14-17
Comparison of gampi paper and nanofibers to chromatography paper used in paper spray-mass spectrometry
- 1 January 2015
- Published by Elsevier in International Journal of Mass Spectrometry
- Vol. 375, 14-17
Comparison of gampi paper and nanofibers to chromatography paper used in paper spray-mass spectrometry
- 1 May 2013
- Published by Elsevier in Forensic Science International
- Vol. 228 (1-3) , 95-99
A microwave-assisted fluorescent labeling method for the separation and detection of amphetamine-like designer drugs by capillary electrophoresis
- 1 May 2013
- Published by Elsevier in Forensic Science International
- Vol. 228 (1-3) , 95-99
A microwave-assisted fluorescent labeling method for the separation and detection of amphetamine-like designer drugs by capillary electrophoresis
- 15 February 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1181 (1-2) , 131-136
Comparison of the separation of nine tryptamine standards based on gas chromatography, high performance liquid chromatography and capillary electrophoresis methods
- 15 February 2008
- Published by Elsevier in Journal of Chromatography A
- Vol. 1181 (1-2) , 131-136
Comparison of the separation of nine tryptamine standards based on gas chromatography, high performance liquid chromatography and capillary electrophoresis methods
- Open Access
- 14 April 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (4) , 557-561
Large-Volume Sample Sweeping with a High Theoretical Plate Number Using a Coupled-Capillary in Capillary Electrophoresis
A large-volume sample injection (> 5 µL) with an extremely high theoretical plate number (N > 107) was achieved when the sweeping-MEKC mode and a coupled-capillary (100 - 50 µm i.d.) were simultaneously used in a capillary electrophoresis (CE) separation. A low-cost and compact violet-LED (∼2 mW) was used as the fluorescence excitation source. As a result, the theoretical plate numbers of the detected peaks (two model compounds: naphthalene-2,3-dicarboxaldehyde derivatized-dopamine and -norepinephrine) were 1.0 × 107 and 7.4 × 106, respectively. The limits of detection (at S/N = 3) of these were determined to be 2.8 × 10-10 M (92 ppt) and 2.3 × 10-10 M (83 ppt), respectively.
- 14 April 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (4) , 557-561
Open AccessLarge-Volume Sample Sweeping with a High Theoretical Plate Number Using a Coupled-Capillary in Capillary Electrophoresis
A large-volume sample injection (> 5 µL) with an extremely high theoretical plate number (N > 107) was achieved when the sweeping-MEKC mode and a coupled-capillary (100 - 50 µm i.d.) were simultaneously used in a capillary electrophoresis (CE) separation. A low-cost and compact violet-LED (∼2 mW) was used as the fluorescence excitation source. As a result, the theoretical plate numbers of the detected peaks (two model compounds: naphthalene-2,3-dicarboxaldehyde derivatized-dopamine and -norepinephrine) were 1.0 × 107 and 7.4 × 106, respectively. The limits of detection (at S/N = 3) of these were determined to be 2.8 × 10-10 M (92 ppt) and 2.3 × 10-10 M (83 ppt), respectively.
- 7 March 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (5-6) , 1255-1262
Comparison of the use of anionic and cationic surfactants for the separation of steroids based on MEKC and sweeping‐MEKC modes
In attempts to improve the selectivity and sensitivity of steroid separation and to determine their migration order, a comparison of the use of anionic and cationic surfactants based on the MEKC and sweeping‐MEKC modes was made. A mixture of six steroids (progesterone, 17‐hydroxy progesterone, 11‐deoxycortisol, corticosterone, cortisone, and cortisol) could be separated and detected by means of the CE/UV‐absorption method. The order of migration time for these steroids was compared under various conditions, including acidic/alkaline buffers, anionic/cationic surfactants, and positive/negative applied voltage, causing the direction of the EOF and the migration of micelles to change. The major rules for generally predicting the migration order of steroids are summarized. The detection limits were significantly improved when the sweeping‐MEKC mode was applied.
- 7 March 2006
- Published by Wiley in Electrophoresis
- Vol. 27 (5-6) , 1255-1262
Comparison of the use of anionic and cationic surfactants for the separation of steroids based on MEKC and sweeping‐MEKC modes
In attempts to improve the selectivity and sensitivity of steroid separation and to determine their migration order, a comparison of the use of anionic and cationic surfactants based on the MEKC and sweeping‐MEKC modes was made. A mixture of six steroids (progesterone, 17‐hydroxy progesterone, 11‐deoxycortisol, corticosterone, cortisone, and cortisol) could be separated and detected by means of the CE/UV‐absorption method. The order of migration time for these steroids was compared under various conditions, including acidic/alkaline buffers, anionic/cationic surfactants, and positive/negative applied voltage, causing the direction of the EOF and the migration of micelles to change. The major rules for generally predicting the migration order of steroids are summarized. The detection limits were significantly improved when the sweeping‐MEKC mode was applied.
- Open Access
- 12 February 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (2) , 235-240
UV Light-Emitting Diode-Induced Fluorescence Detection Combined with Online Sample Concentration Techniques for Capillary Electrophoresis
The application of an ultraviolet (UV) light-emitting diode (LED) to on-line sample concentration/fluorescence detection in capillary electrophoresis (CE) is described. The utility of a UV-LED (peak emission wavelength at 380 nm, ∼2 mW) for fluorescence detection was demonstrated by examining both a naturally fluorescent (riboflavin) compound and a non-fluorescent compound (tryptophan), respectively. The detection limit for riboflavin was determined to be 0.2 ppm by the normal MEKC mode, which was improved to 3 - 7 ppb when dynamic pH-junction technique was applied. On the other hand, the detection limit of the tryptophan derivative was determined to be 1.5 ppm using the MEKC mode, which was improved to 3 ppb when the sweeping-MEKC mode was applied. In an analysis of an actual sample, the concentrations of riboflavin in beer, and tryptophan in urine and milk samples were determined, respectively.
- 12 February 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (2) , 235-240
Open AccessUV Light-Emitting Diode-Induced Fluorescence Detection Combined with Online Sample Concentration Techniques for Capillary Electrophoresis
The application of an ultraviolet (UV) light-emitting diode (LED) to on-line sample concentration/fluorescence detection in capillary electrophoresis (CE) is described. The utility of a UV-LED (peak emission wavelength at 380 nm, ∼2 mW) for fluorescence detection was demonstrated by examining both a naturally fluorescent (riboflavin) compound and a non-fluorescent compound (tryptophan), respectively. The detection limit for riboflavin was determined to be 0.2 ppm by the normal MEKC mode, which was improved to 3 - 7 ppb when dynamic pH-junction technique was applied. On the other hand, the detection limit of the tryptophan derivative was determined to be 1.5 ppm using the MEKC mode, which was improved to 3 ppb when the sweeping-MEKC mode was applied. In an analysis of an actual sample, the concentrations of riboflavin in beer, and tryptophan in urine and milk samples were determined, respectively.
- 15 November 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (22) , 4355-4359
Online identification of the fluorescent whitening agent 4,4-bis(2-sulfostyrol)biphenyl using a sweeping technique combined with capillary electrophoresis/77 K fluorescence spectroscopy
The feasibility of combining the techniques of online concentration and CE/low-temperature fluorescence spectroscopy in the detection and identification of E,E-4,4'-bis(2-sulfostyryl)biphenyl (DSBP) in synthetic detergents at 77 K is demonstrated. The technique involves the use of sweeping-MEKC, and was used for the initial online concentration and separation, after which a cryogenic molecular fluorescence experiment was performed at 77 K. The proposed method not only permits the separation and detection of E,E-DSBP in a synthetic detergent sample, but also ensures that the online spectrum is readily distinguishable and can be unambiguously assigned at 77 K. The photoconversion and isomer separation of DSBP are also described.
- 15 November 2005
- Published by Wiley in Electrophoresis
- Vol. 26 (22) , 4355-4359
Online identification of the fluorescent whitening agent 4,4-bis(2-sulfostyrol)biphenyl using a sweeping technique combined with capillary electrophoresis/77 K fluorescence spectroscopy
The feasibility of combining the techniques of online concentration and CE/low-temperature fluorescence spectroscopy in the detection and identification of E,E-4,4'-bis(2-sulfostyryl)biphenyl (DSBP) in synthetic detergents at 77 K is demonstrated. The technique involves the use of sweeping-MEKC, and was used for the initial online concentration and separation, after which a cryogenic molecular fluorescence experiment was performed at 77 K. The proposed method not only permits the separation and detection of E,E-DSBP in a synthetic detergent sample, but also ensures that the online spectrum is readily distinguishable and can be unambiguously assigned at 77 K. The photoconversion and isomer separation of DSBP are also described.