José Bento Borba da Silva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
José Bento Borba da Silva has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Daniel Andrada
Department of Chemistry , Federal University of Minas Gerais , Belo Horizonte, MG, Brazil
3 shared publications- Frederico Garcia Pinto
Universidade Federal de Viçosa
3 shared publications Cristina Gonçalves Magalhães
Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
2 shared publicationsJosianne Nicácio Silveira
Laboratório de Toxicologia Ocupacional, Faculdade de Farmácia, Universidade Federal de Minas Gerais
2 shared publicationsUlisses Vilela Rey
Department of Chemistry , Federal University of Minas Gerais , Belo Horizonte, MG, Brazil
2 shared publicationsBerta R. Nunes
Universidade Federal de Minas Gerais, Belo Horizonte, Brazil
1 shared publication
Latest Publications
- 11 March 2010
- Published by Taylor & Francis in Analytical Letters
- Vol. 43 (6) , 960-971
Quantification of Inorganic Constituents in Brazilian Human Milk by ICP OES
A fast procedure to determine essential and toxic metals in Brazilian human milk by ICP OES is proposed. Mature and colostrum human milk samples were mineralized using closed-pressurized and high-performance microwave digestion oven. Aqueous calibration was performed for all analytes investigated. A reference material, Infant Formula, was analyzed to test the accuracy of the proposed methodology. Recovery rates ranged between 83 and 117%. The precision of the method was better than 3.3% (R.S.D.) for all analytes investigated. Higher concentrations, on average, of the metals studied in the colostrum human milk could be found in relation to the mature human milk.
- 11 March 2010
- Published by Taylor & Francis in Analytical Letters
- Vol. 43 (6) , 960-971
Quantification of Inorganic Constituents in Brazilian Human Milk by ICP OES
A fast procedure to determine essential and toxic metals in Brazilian human milk by ICP OES is proposed. Mature and colostrum human milk samples were mineralized using closed-pressurized and high-performance microwave digestion oven. Aqueous calibration was performed for all analytes investigated. A reference material, Infant Formula, was analyzed to test the accuracy of the proposed methodology. Recovery rates ranged between 83 and 117%. The precision of the method was better than 3.3% (R.S.D.) for all analytes investigated. Higher concentrations, on average, of the metals studied in the colostrum human milk could be found in relation to the mature human milk.
- 29 April 2009
- Published by Taylor & Francis in Analytical Letters
- Vol. 42 (7) , 923-934
Direct Determination of Mn in Breast Milk by GF AAS After Multivariate Optimization
The procedure proposed in this work includes a 50% v/v dilution of breast milk with TRIS (hidroximetilaminometano 80% v/v) or MEA (monoetanolamina 20% v/v) solutions and the introduction of 20 µL samples or analytical solutions in a graphite furnace. The optimization of the instrumental conditions was made using multivariate tools (fractional factorial and central composite design planning). The accuracy was tested with certified reference material (Infant Formulat NIST® 1846) using the optimized conditions for each diluent. The accuracy has only been acceptable when TRIS was used. The method used to determine Mn in breast milk with a limit of detection of 0.28 µg L−1 and a characteristic mass of 1.9 pg.
- 29 April 2009
- Published by Taylor & Francis in Analytical Letters
- Vol. 42 (7) , 923-934
Direct Determination of Mn in Breast Milk by GF AAS After Multivariate Optimization
The procedure proposed in this work includes a 50% v/v dilution of breast milk with TRIS (hidroximetilaminometano 80% v/v) or MEA (monoetanolamina 20% v/v) solutions and the introduction of 20 µL samples or analytical solutions in a graphite furnace. The optimization of the instrumental conditions was made using multivariate tools (fractional factorial and central composite design planning). The accuracy was tested with certified reference material (Infant Formulat NIST® 1846) using the optimized conditions for each diluent. The accuracy has only been acceptable when TRIS was used. The method used to determine Mn in breast milk with a limit of detection of 0.28 µg L−1 and a characteristic mass of 1.9 pg.
- Open Access
- 10 December 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (12) , 1605-1609
Determination of Manganese in Urine and Whole Blood Samples by Electrothermal Atomic Absorption Spectrometry: Comparison of Chemical Modifiers
In this work, methodologies to determine manganese (Mn) in urine and whole blood by electrothermal atomic absorption spectrometry were developed. The use of Ru, Rh, and Zr as permanent modifiers, Pd as a modifier in solution, and the condition without modifier were investigated for the direct determination of Mn in urine and whole blood samples. The best results for Mn in urine and in whole blood were obtained without modifier use. The analytical characteristic, such as accuracy, precision and limit of detection of the proposed methodology were adequate.
- 10 December 2006
- Published by Springer Nature in Analytical Sciences
- Vol. 22 (12) , 1605-1609
Open AccessDetermination of Manganese in Urine and Whole Blood Samples by Electrothermal Atomic Absorption Spectrometry: Comparison of Chemical Modifiers
In this work, methodologies to determine manganese (Mn) in urine and whole blood by electrothermal atomic absorption spectrometry were developed. The use of Ru, Rh, and Zr as permanent modifiers, Pd as a modifier in solution, and the condition without modifier were investigated for the direct determination of Mn in urine and whole blood samples. The best results for Mn in urine and in whole blood were obtained without modifier use. The analytical characteristic, such as accuracy, precision and limit of detection of the proposed methodology were adequate.
- 1 September 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (12) , 2441-2451
Employment of Ruthenium as Permanent Modifier for the Determination of Copper in Serum Samples by Electrothermal Atomic Absorption Spectrometry
In the present study, the determination of copper in human serum by electrothermal atomic absorption spectrometry was investigated with susceptible substances to act as chemical modifiers. The optimization of the method involved studies of pyrolysis and atomization temperature curves in the diluted human serum. Ruthenium was the best modifier. With this modifier, recoveries of spiked serum samples on different days ranged from 92% to 105% with a relative standard deviation (RSD) lower than 10% and a tube lifetime higher than 2000 cycles.
- 1 September 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (12) , 2441-2451
Employment of Ruthenium as Permanent Modifier for the Determination of Copper in Serum Samples by Electrothermal Atomic Absorption Spectrometry
In the present study, the determination of copper in human serum by electrothermal atomic absorption spectrometry was investigated with susceptible substances to act as chemical modifiers. The optimization of the method involved studies of pyrolysis and atomization temperature curves in the diluted human serum. Ruthenium was the best modifier. With this modifier, recoveries of spiked serum samples on different days ranged from 92% to 105% with a relative standard deviation (RSD) lower than 10% and a tube lifetime higher than 2000 cycles.
- Open Access
- 1 April 2006
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 17 (2) , 328-332
Direct determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers
- 1 April 2006
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 17 (2) , 328-332
Open AccessDirect determination of lead in human urine and serum samples by electrothermal atomic absorption spectrometry and permanent modifiers
- Open Access
- 28 December 2005
- Published by Ecletica Quimica in Ecletica Quimica
- Vol. 30 (4) , 59-65
Determinação de cádmio em amostras de urina e soro humano por espectrometria de absorção atômica em forno de grafite usando irídio como modificador permanente
No presente estudo, foram investigadas diferentes substâncias para atuarem como modificadores químicos na determinação direta de cádmio em soro e urina humanos sem digestão prévia das amostras. A preparação da amostra foi feita diretamente nos copos do amostrador automático por diluição 1+4 de soro e 1+1 de urina com ácido nítrico 1% v/v contendo 0.02% v/v de cloreto de tricetil metil amônio (CTAC). Foram investigadas as melhores condições de determinação por meio de curvas de temperatura de pirólise e atomização na presença da matriz e do analito levando-se em conta a forma do pulso de absorção, baixas temperaturas na atomização, fundo corrigido e sensibilidade. Foram efetuados estudos na ausência de modificador e com a mistura universal em solução de Pd e Mg (10 e 15 μg, respectivamente) e com rutênio (500 μg) e irídio (500 μg) como modificadores permanentes. Para Ir permanente, as massas características foram 0.8 pg para soro e 0.7 pg para urina (recomendado de 2 pg). Na investigação do uso de Ir permanente, foi observado que o pico foi simétrico, retornando à linha de base em 3s e com fundo corrigido completamente com valores ótimos por pirólises e atomização de 300 e 1000°C para soro e 300 e 1100 o C para urina.
- 28 December 2005
- Published by Ecletica Quimica in Ecletica Quimica
- Vol. 30 (4) , 59-65
Open AccessDeterminação de cádmio em amostras de urina e soro humano por espectrometria de absorção atômica em forno de grafite usando irídio como modificador permanente
No presente estudo, foram investigadas diferentes substâncias para atuarem como modificadores químicos na determinação direta de cádmio em soro e urina humanos sem digestão prévia das amostras. A preparação da amostra foi feita diretamente nos copos do amostrador automático por diluição 1+4 de soro e 1+1 de urina com ácido nítrico 1% v/v contendo 0.02% v/v de cloreto de tricetil metil amônio (CTAC). Foram investigadas as melhores condições de determinação por meio de curvas de temperatura de pirólise e atomização na presença da matriz e do analito levando-se em conta a forma do pulso de absorção, baixas temperaturas na atomização, fundo corrigido e sensibilidade. Foram efetuados estudos na ausência de modificador e com a mistura universal em solução de Pd e Mg (10 e 15 μg, respectivamente) e com rutênio (500 μg) e irídio (500 μg) como modificadores permanentes. Para Ir permanente, as massas características foram 0.8 pg para soro e 0.7 pg para urina (recomendado de 2 pg). Na investigação do uso de Ir permanente, foi observado que o pico foi simétrico, retornando à linha de base em 3s e com fundo corrigido completamente com valores ótimos por pirólises e atomização de 300 e 1000°C para soro e 300 e 1100 o C para urina.
- 7 October 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (11) , 1404-1406
Antimony and chromium determination in Brazilian sugar cane spirit, cachaça, by electrothermal atomic absorption spectrometry using matrix matching calibration and ruthenium as permanent modifier
This work reports a method for the determination of antimony and chromium in Brazilian sugar cane spirit, cachaça, by electrothermal atomic absorption spectrometry (ET-AAS) employing matrix matching calibration and ruthenium, thermally deposited (500 µg), as permanent modifier. The best pyrolysis and atomisation temperatures were 600 °C and 1400 °C for antimony while for chromium it was 700 °C and 2500 °C, respectively. For chromium, the peak returned to the baseline after 15 s in the absence of any modifier, whilst using Ru as permanent modifier, the peak returned to the baseline in 5 s, showing high symmetry. The characteristic mass (mo) obtained for chromium was 2.4 pg without modifier and 2.5 pg with Ru permanent (recommended 8.0 pg). For antimony it was 43.4 pg and 24.6 pg without modifier and with Ru permanent, respectively (recommended 200 pg). Matrix matching calibration curves (aqueous solutions 40% v/v in ethanol) gave a value of r (linear regression coefficient) higher than 0.999 for the two analytes. For antimony, two samples of cachaça spiked with 30.0, 60.0 and 90.0 µg l−1 showed a range of recovery from 98.8% to 110.0%, while for chromium it was from 101.7% to 107.9%. The detection limits (k = 3, n = 10) were 43 pg for antimony and 2 pg for chromium. The results obtained from analysis of fifty-two samples of cachaça, from Alto Vale do Jequitinhonha, Minas Gerais State, Brazil, varied from non-detectable to 39.1 µg l−1 for antimony and the RSDs, (n = 3), from 2.87% to 11.10%. For chromium, the same samples showed results from 0.64 to 1.53 µg l−1 (RSDs from 0.04% to 11.76%).
- 7 October 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (11) , 1404-1406
Antimony and chromium determination in Brazilian sugar cane spirit, cachaça, by electrothermal atomic absorption spectrometry using matrix matching calibration and ruthenium as permanent modifier
This work reports a method for the determination of antimony and chromium in Brazilian sugar cane spirit, cachaça, by electrothermal atomic absorption spectrometry (ET-AAS) employing matrix matching calibration and ruthenium, thermally deposited (500 µg), as permanent modifier. The best pyrolysis and atomisation temperatures were 600 °C and 1400 °C for antimony while for chromium it was 700 °C and 2500 °C, respectively. For chromium, the peak returned to the baseline after 15 s in the absence of any modifier, whilst using Ru as permanent modifier, the peak returned to the baseline in 5 s, showing high symmetry. The characteristic mass (mo) obtained for chromium was 2.4 pg without modifier and 2.5 pg with Ru permanent (recommended 8.0 pg). For antimony it was 43.4 pg and 24.6 pg without modifier and with Ru permanent, respectively (recommended 200 pg). Matrix matching calibration curves (aqueous solutions 40% v/v in ethanol) gave a value of r (linear regression coefficient) higher than 0.999 for the two analytes. For antimony, two samples of cachaça spiked with 30.0, 60.0 and 90.0 µg l−1 showed a range of recovery from 98.8% to 110.0%, while for chromium it was from 101.7% to 107.9%. The detection limits (k = 3, n = 10) were 43 pg for antimony and 2 pg for chromium. The results obtained from analysis of fifty-two samples of cachaça, from Alto Vale do Jequitinhonha, Minas Gerais State, Brazil, varied from non-detectable to 39.1 µg l−1 for antimony and the RSDs, (n = 3), from 2.87% to 11.10%. For chromium, the same samples showed results from 0.64 to 1.53 µg l−1 (RSDs from 0.04% to 11.76%).
- 18 June 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (7) , 787-789
Direct determination of bismuth in urine samples by electrothermal atomic absorption spectrometry: study of chemical modifiers
In this work the performance of some chemical modifiers (no modifier, Pd + Mg, Ir in solution, Ru, Ir or Zr independently as permanent modifier and Ir + Rh permanent) was investigated for the direct determination of Bi in human urine by electrothermal atomic absorption spectrometry (ETAAS). The urine samples were diluted directly in the autosampler cups with one-fold dilution with nitric acid 1% v/v. The obtaining of the permanent modifiers (500 µg of iridium, ruthenium and zirconium independently and 250 µg of Ir plus 250 µg of rhodium) was described elsewhere. Without modifier at all temperatures the signal was negative with a high background. Using Pd + Mg the best temperatures were of 1000 and 2500 °C, respectively, for pyrolysis and atomization, but the sensitivity was half that when using Ir + Rh. Using ruthenium, iridium or zirconium independently no peak was obtained but a plateau that did not return to baseline even in 15 s of atomization. With iridium applied in solution together with the sample the best pyrolysis and atomization temperatures were of 900 and 2500 °C, respectively, but the sensitivity was analogous with that obtained using Pd + Mg. Using Ir + Rh, the optimum pyrolysis and atomization temperatures were lower (900 and 1400 °C), but in this case the best sensitivity was obtained with a characteristic mass of 29.2 pg (recommended of 30 pg for the manufacturer for the metal in aqueous solutions). With this modifier, the obtained peak was very symmetrical, returning to the baseline in 3 s with very low background. The use of low temperatures and a low time of atomization coupled to the use of permanent modifer will certainly extend the lifetime of the graphite tube. Aqueous calibration curves and standard addition were parallel with slopes of 0.042 and 0.044 for aqueous and standard addition, respectively. For this reason, the calibration was carried out with aqueous solutions. The r values of calibration curves were higher than 0.99. Spiked urine samples with 5.0, 10.0, 15.0, 20.0, 25.0 and 30.0 µg l−1, analysed on different days, presented a recovery between 80.0 and 100.0%. The limit of detection was 50 pg. The lifetime of the tube was more than 500 cycles of atomization.
- 18 June 2003
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 18 (7) , 787-789
Direct determination of bismuth in urine samples by electrothermal atomic absorption spectrometry: study of chemical modifiers
In this work the performance of some chemical modifiers (no modifier, Pd + Mg, Ir in solution, Ru, Ir or Zr independently as permanent modifier and Ir + Rh permanent) was investigated for the direct determination of Bi in human urine by electrothermal atomic absorption spectrometry (ETAAS). The urine samples were diluted directly in the autosampler cups with one-fold dilution with nitric acid 1% v/v. The obtaining of the permanent modifiers (500 µg of iridium, ruthenium and zirconium independently and 250 µg of Ir plus 250 µg of rhodium) was described elsewhere. Without modifier at all temperatures the signal was negative with a high background. Using Pd + Mg the best temperatures were of 1000 and 2500 °C, respectively, for pyrolysis and atomization, but the sensitivity was half that when using Ir + Rh. Using ruthenium, iridium or zirconium independently no peak was obtained but a plateau that did not return to baseline even in 15 s of atomization. With iridium applied in solution together with the sample the best pyrolysis and atomization temperatures were of 900 and 2500 °C, respectively, but the sensitivity was analogous with that obtained using Pd + Mg. Using Ir + Rh, the optimum pyrolysis and atomization temperatures were lower (900 and 1400 °C), but in this case the best sensitivity was obtained with a characteristic mass of 29.2 pg (recommended of 30 pg for the manufacturer for the metal in aqueous solutions). With this modifier, the obtained peak was very symmetrical, returning to the baseline in 3 s with very low background. The use of low temperatures and a low time of atomization coupled to the use of permanent modifer will certainly extend the lifetime of the graphite tube. Aqueous calibration curves and standard addition were parallel with slopes of 0.042 and 0.044 for aqueous and standard addition, respectively. For this reason, the calibration was carried out with aqueous solutions. The r values of calibration curves were higher than 0.99. Spiked urine samples with 5.0, 10.0, 15.0, 20.0, 25.0 and 30.0 µg l−1, analysed on different days, presented a recovery between 80.0 and 100.0%. The limit of detection was 50 pg. The lifetime of the tube was more than 500 cycles of atomization.
- 1 December 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (7-8) , 1301-1305
Direct determination of Cr and Cu in urine samples by electrothermal atomic absorption spectrometry using ruthenium as permanent modifier (R1)
In this study Ru, deposited thermally on an integrated platform pyrolytic graphite tube, is proposed as a permanent modifier for the determination of Cu and Cr in urine samples by electrothermal atomic absorption spectrometry. The samples were diluted 1:1 with nitric acid (1% v/v). Pyrolysis and atomization temperatures for spiked urine samples were 1,100 °C and 1,900 °C respectively for Cu, and 1,400 °C and 2,500 °C respectively for Cr. For comparison purposes, the conventional modification with Pd+Mg was also studied. The sensitivity for Ru as permanent modifier was higher for the two analytes. The characteristic masses were 7.3 and 17.7 for Cr and Cu. The detection limits (3σ) were 0.22 and 0.32 µg/L, for Cr and Cu, respectively. Good agreement was obtained with certified urine samples for the two elements.
- 1 December 2002
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 374 (7-8) , 1301-1305
Direct determination of Cr and Cu in urine samples by electrothermal atomic absorption spectrometry using ruthenium as permanent modifier (R1)
In this study Ru, deposited thermally on an integrated platform pyrolytic graphite tube, is proposed as a permanent modifier for the determination of Cu and Cr in urine samples by electrothermal atomic absorption spectrometry. The samples were diluted 1:1 with nitric acid (1% v/v). Pyrolysis and atomization temperatures for spiked urine samples were 1,100 °C and 1,900 °C respectively for Cu, and 1,400 °C and 2,500 °C respectively for Cr. For comparison purposes, the conventional modification with Pd+Mg was also studied. The sensitivity for Ru as permanent modifier was higher for the two analytes. The characteristic masses were 7.3 and 17.7 for Cr and Cu. The detection limits (3σ) were 0.22 and 0.32 µg/L, for Cr and Cu, respectively. Good agreement was obtained with certified urine samples for the two elements.