Go Sakai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Go Sakai has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Noboru Yamazoe
Department of Material Sciences, Faculty of Engineering Sciences, Kyushu University, 6–1 Kasuga Koen, Kasuga-shi, Fukuoka 816–8580, Japan
5 shared publications- Kengo Shimanoe
Department of Advanced Materials Science and Engineering Faculty of Engineering Sciences Kyushu University Kasuga Fukuoka Japan
3 shared publications - Norio Miura
Kyushu University
2 shared publications Hajime Kusaba
Department of Molecular and Material Sciences, Interdisciplinary Graduate School of Engineering Sciences, Kyushu UniversityFukuoka, Japan
1 shared publicationKazuya Kinoshita
Department of Molecular and Material Sciences, Interdisciplinary Graduate School of Engineering Sciences, Kyushu UniversityFukuoka, Japan
1 shared publication- Kenji Obata
Department of Materials Science and Chemical Engineering, Kitakyushu National College of Technology
1 shared publication
Latest Publications
- Open Access
- 1 January 2015
- Published by Ceramic Society of Japan in Journal of the Ceramic Society of Japan
- Vol. 123 (1442) , 995-998
Formation of CaFe2O4 porous structure by addition of Zr in malic acid complex
The effect of Zr addition into malic acid complex was examined for the purpose of the improvement of microstructure and specific surface area of CaFe2O4. The CaFe2O4 phase could be obtained for both unadded and Zr-added (5 and 10 mol % with respect to Fe) system by calcination of precursor derived from malic acid complex at 700°C which is almost 200°C lower than that of conventional solid-state reaction method. Among the examined products, only the 5 mol % Zr-added product revealed characteristic smaller grains connected three dimensional porous structures resulting in higher specific surface area compared with unadded and 10 mol % Zr-added products. XPS measurements revealed that there are no notable changes in valence state for all constituent elements. The obtained final product of 5 mol % Zr-added CaFe2O4 is worth further investigate for various application from a view point of improved higher specific surface area and characteristic microstructure as well as the functionality of the material itself.
- 1 January 2015
- Published by Ceramic Society of Japan in Journal of the Ceramic Society of Japan
- Vol. 123 (1442) , 995-998
Open AccessFormation of CaFe2O4 porous structure by addition of Zr in malic acid complex
The effect of Zr addition into malic acid complex was examined for the purpose of the improvement of microstructure and specific surface area of CaFe2O4. The CaFe2O4 phase could be obtained for both unadded and Zr-added (5 and 10 mol % with respect to Fe) system by calcination of precursor derived from malic acid complex at 700°C which is almost 200°C lower than that of conventional solid-state reaction method. Among the examined products, only the 5 mol % Zr-added product revealed characteristic smaller grains connected three dimensional porous structures resulting in higher specific surface area compared with unadded and 10 mol % Zr-added products. XPS measurements revealed that there are no notable changes in valence state for all constituent elements. The obtained final product of 5 mol % Zr-added CaFe2O4 is worth further investigate for various application from a view point of improved higher specific surface area and characteristic microstructure as well as the functionality of the material itself.
- 1 January 2004
- Published by Wiley
- p. 471-476
Stabilization of Counter Electrode for Nasicon Based Potentiometric Co2 Sensor
- 1 January 2004
- Published by Wiley
- p. 471-476
Stabilization of Counter Electrode for Nasicon Based Potentiometric Co2 Sensor
- 1 March 2002
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 31 (3) , 344-345
Influences of A-site Partial Substitution for BaCo0.7Fe0.3O3 Oxide on Perovskite Structure and Oxygen Permeability
Oxygen permeation property of A-site partially substituted barium cobaltites, A′xBa1-xCo0.7Fe0.3O3-δ (A′=Ba, Pr, Gd, Dy, Y and Yb), were examined. Substitution of Ba by Dy, Y or Yb was found to stabilize cubic perovskite structure even when x remained as small as 0.05. As a result, oxygen permeation through the disks made of these oxides appeared at temperature lower than 500 °C, and reached fairly high levels at elevated temperature.
- 1 March 2002
- Published by Oxford University Press (OUP) in Chemistry Letters
- Vol. 31 (3) , 344-345
Influences of A-site Partial Substitution for BaCo0.7Fe0.3O3 Oxide on Perovskite Structure and Oxygen Permeability
Oxygen permeation property of A-site partially substituted barium cobaltites, A′xBa1-xCo0.7Fe0.3O3-δ (A′=Ba, Pr, Gd, Dy, Y and Yb), were examined. Substitution of Ba by Dy, Y or Yb was found to stabilize cubic perovskite structure even when x remained as small as 0.05. As a result, oxygen permeation through the disks made of these oxides appeared at temperature lower than 500 °C, and reached fairly high levels at elevated temperature.
- 1 January 2000
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 120 (10) , 476-481
Thin-film-type oxide semiconductor sensor for detecting acetone in human expiration aiming at diagnosis of diabetes
Thin-film-type oxide semiconductor gas sensors sensitive to acetone were explored for the diagnosis of diabetes. SnO2 and ZnO were tested as a base sensor material. When fabricated into a thick-film-type sensor, SnO2 was inferior to ZnO in the acetone sensitivity. However, on changing to a thin-film-type sensor, SnO2 proved to be more sensitive to acetone than ZnO. The acetone sensitivity of the SnO2-based thin film sensor could be improved by the addition (0.1wt%) of noble metals, such as Rh and Ru. The resulting sensor using Rh-SnO2 could detect as dilute as 0.2ppm acetone in human expiration at 300°C without being disturbed by changes in O2 and CO2 concentrations.
- 1 January 2000
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 120 (10) , 476-481
Thin-film-type oxide semiconductor sensor for detecting acetone in human expiration aiming at diagnosis of diabetes
Thin-film-type oxide semiconductor gas sensors sensitive to acetone were explored for the diagnosis of diabetes. SnO2 and ZnO were tested as a base sensor material. When fabricated into a thick-film-type sensor, SnO2 was inferior to ZnO in the acetone sensitivity. However, on changing to a thin-film-type sensor, SnO2 proved to be more sensitive to acetone than ZnO. The acetone sensitivity of the SnO2-based thin film sensor could be improved by the addition (0.1wt%) of noble metals, such as Rh and Ru. The resulting sensor using Rh-SnO2 could detect as dilute as 0.2ppm acetone in human expiration at 300°C without being disturbed by changes in O2 and CO2 concentrations.
- 1 January 1998
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 118 (2) , 60-63
Recent Trends in Research for Environmental Gas Sensors
- 1 January 1998
- Published by Institute of Electrical Engineers of Japan (IEE Japan) in IEEJ Transactions on Sensors and Micromachines
- Vol. 118 (2) , 60-63
Recent Trends in Research for Environmental Gas Sensors