Thomas A. Horbett
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Thomas A. Horbett has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
Buddy D. Ratner
Department of Chemical Engineering, University of Washington, Seattle, Washington 98195
3 shared publicationsYuguang Wu
Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA
3 shared publicationsJohn M. Grunkemeier
Department of Bioengineering, Box 351750, University of Washington, Seattle, Washington 98195
2 shared publicationsLan Cao
Department of Chemical Engineering, University of Washington, Seattle, Washington 98195, USA
2 shared publicationsMingchao Shen
Department of Bioengineering, University of Washington, Seattle, Washington 98195, USA
2 shared publicationsSivaprasad Sukavaneshvar
Utah Artificial Heart Institute, Salt Lake City, Utah 84103
2 shared publications
Latest Publications
- 29 October 2007
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 85A (3) , 829-839
Effect of adsorbed von Willebrand factor and fibrinogen on platelet interactions with synthetic materials under flow conditions
The effect of adsorbed fibrinogen (Fg) and von Willebrand factor (vWf) on platelet adhesion at low or high shear rate to several materials was studied. The materials studied were polyethylene terephthalate (PET), polystyrene (PS), glass, and tetraglyme‐coated PET. The materials were preadsorbed with normal plasma, serum, and Fg‐deficient plasma replenished with various amounts of Fg, and vWf‐deficient plasma with or without added vWf. Platelet adhesion to PET preadsorbed with Fg‐deficient plasma or serum was low at either low or high shear rate, but increased as Fg was added to the preadsorption media. However, the effect of added Fg on adhesion at the higher shear rate was much greater on surfaces preadsorbed with plasma than for serum, probably due to the much lower vWf concentration in serum in comparison to plasma. Platelet adhesion to either polystyrene or glass preadsorbed with normal plasma was much higher at high shear than low shear, but when vWf‐deficient plasma was used to preadsorb these surfaces, adhesion was much less at the higher shear rate than at low shear rate. Platelet adhesion to polystyrene preadsorbed with vWf‐deficient plasma to which vWf was added was higher at high shear rate than low shear rate. These results show that under high shear rate, both Fg and vWf are required for platelet adhesion on synthetic biomaterials. The results suggest that developing surfaces that adsorb low amounts of vWf is a good approach to improving the blood compatibility of biomaterials. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
- 29 October 2007
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 85A (3) , 829-839
Effect of adsorbed von Willebrand factor and fibrinogen on platelet interactions with synthetic materials under flow conditions
The effect of adsorbed fibrinogen (Fg) and von Willebrand factor (vWf) on platelet adhesion at low or high shear rate to several materials was studied. The materials studied were polyethylene terephthalate (PET), polystyrene (PS), glass, and tetraglyme‐coated PET. The materials were preadsorbed with normal plasma, serum, and Fg‐deficient plasma replenished with various amounts of Fg, and vWf‐deficient plasma with or without added vWf. Platelet adhesion to PET preadsorbed with Fg‐deficient plasma or serum was low at either low or high shear rate, but increased as Fg was added to the preadsorption media. However, the effect of added Fg on adhesion at the higher shear rate was much greater on surfaces preadsorbed with plasma than for serum, probably due to the much lower vWf concentration in serum in comparison to plasma. Platelet adhesion to either polystyrene or glass preadsorbed with normal plasma was much higher at high shear than low shear, but when vWf‐deficient plasma was used to preadsorb these surfaces, adhesion was much less at the higher shear rate than at low shear rate. Platelet adhesion to polystyrene preadsorbed with vWf‐deficient plasma to which vWf was added was higher at high shear rate than low shear rate. These results show that under high shear rate, both Fg and vWf are required for platelet adhesion on synthetic biomaterials. The results suggest that developing surfaces that adsorb low amounts of vWf is a good approach to improving the blood compatibility of biomaterials. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
- 18 January 2007
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 81A (4) , 827-837
Plasma‐deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition
The ability of tetraethylene glycol dimethyl ether (tetraglyme) plasma deposited coatings exhibiting ultralow fibrinogen adsorption to reduce blood activation was studied with six in vitro methods, namely fibrinogen and von Willebrand's factor adsorption, total protein adsorption, clotting time in recalcified plasma, platelet adhesion and procoagulant activity, and whole blood thrombosis in a disturbed flow catheter model. Surface plasmon resonance results showed that tetraglyme surfaces strongly resisted the adsorption of all proteins from human plasma. The clotting time in the presence of tetraglyme surfaces was lengthened compared with controls, indicating a lower activation of the intrinsic coagulation cascade. Platelet adhesion and thrombin generation by adherent platelets were greatly reduced on tetraglyme‐coated materials, compared with uncoated and Biospan®‐coated glass slides. In the in vitro disturbed blood flow model, tetraglyme plasma coated catheters had 50% less thrombus than did the uncoated catheters. Tetraglyme‐coated materials thus had greatly reduced blood interactions as measured with all six methods. The improved blood compatibility of plasma‐deposited tetraglyme is thus not only due to their reduced platelet adhesion and activation, but also to a generalized reduction in blood interactions. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
- 18 January 2007
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 81A (4) , 827-837
Plasma‐deposited tetraglyme surfaces greatly reduce total blood protein adsorption, contact activation, platelet adhesion, platelet procoagulant activity, and in vitro thrombus deposition
The ability of tetraethylene glycol dimethyl ether (tetraglyme) plasma deposited coatings exhibiting ultralow fibrinogen adsorption to reduce blood activation was studied with six in vitro methods, namely fibrinogen and von Willebrand's factor adsorption, total protein adsorption, clotting time in recalcified plasma, platelet adhesion and procoagulant activity, and whole blood thrombosis in a disturbed flow catheter model. Surface plasmon resonance results showed that tetraglyme surfaces strongly resisted the adsorption of all proteins from human plasma. The clotting time in the presence of tetraglyme surfaces was lengthened compared with controls, indicating a lower activation of the intrinsic coagulation cascade. Platelet adhesion and thrombin generation by adherent platelets were greatly reduced on tetraglyme‐coated materials, compared with uncoated and Biospan®‐coated glass slides. In the in vitro disturbed blood flow model, tetraglyme plasma coated catheters had 50% less thrombus than did the uncoated catheters. Tetraglyme‐coated materials thus had greatly reduced blood interactions as measured with all six methods. The improved blood compatibility of plasma‐deposited tetraglyme is thus not only due to their reduced platelet adhesion and activation, but also to a generalized reduction in blood interactions. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res 2007
- 1 August 2006
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 79A (4) , 788-803
Glow discharge plasma treatment of polyethylene tubing with tetraglyme results in ultralow fibrinogen adsorption and greatly reduced platelet adhesion
Previous studies from our lab have shown that fibrinogen adsorption (ΓFg) must be reduced below 10 ng/cm2 to significantly reduce platelet adhesion, and that radio frequency glow discharge (RFGD) treatment of polymeric films in the presence of tetraethylene glycol dimethyl ether (tetraglyme) can reduce ΓFg to the desired ultralow value. In this report, the effects of RFGD coatings of tetraglyme on the lumenal surface of PE tubing on ΓFg and on blood interactions both in vitro and ex vivo are described. ΓFg on the tetraglyme‐coated PE tubing was reduced to the desired ultralow level (2), and we also observed a significant decrease in adsorption of von Willebrand's factor. In vitro platelet adhesion from washed platelet suspensions, platelet rich plasma, or whole blood to tetraglyme‐coated PE tubing was decreased compared to PE, polyurethane, or silicone rubber tubes. In addition, thrombin generation by platelets adherent to tetraglyme‐coated PE was also much less than by platelets adherent to PE. When inserted in an ex vivo carotid artery‐carotid artery shunt in sheep, the RFGD tetraglyme‐coated PE exhibited a very low number of adherent platelets compared to heparin‐coated, chromic acid‐etched, or plain PE. The RFGD tetraglyme‐coated PE tubes exhibited high protein and platelet resistance in vitro, and high platelet resistance ex vivo. The improved hemocompatibility is attributed to the unique chemical structure of RFGD tetraglyme that makes it highly protein resistant. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
- 1 August 2006
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 79A (4) , 788-803
Glow discharge plasma treatment of polyethylene tubing with tetraglyme results in ultralow fibrinogen adsorption and greatly reduced platelet adhesion
Previous studies from our lab have shown that fibrinogen adsorption (ΓFg) must be reduced below 10 ng/cm2 to significantly reduce platelet adhesion, and that radio frequency glow discharge (RFGD) treatment of polymeric films in the presence of tetraethylene glycol dimethyl ether (tetraglyme) can reduce ΓFg to the desired ultralow value. In this report, the effects of RFGD coatings of tetraglyme on the lumenal surface of PE tubing on ΓFg and on blood interactions both in vitro and ex vivo are described. ΓFg on the tetraglyme‐coated PE tubing was reduced to the desired ultralow level (2), and we also observed a significant decrease in adsorption of von Willebrand's factor. In vitro platelet adhesion from washed platelet suspensions, platelet rich plasma, or whole blood to tetraglyme‐coated PE tubing was decreased compared to PE, polyurethane, or silicone rubber tubes. In addition, thrombin generation by platelets adherent to tetraglyme‐coated PE was also much less than by platelets adherent to PE. When inserted in an ex vivo carotid artery‐carotid artery shunt in sheep, the RFGD tetraglyme‐coated PE exhibited a very low number of adherent platelets compared to heparin‐coated, chromic acid‐etched, or plain PE. The RFGD tetraglyme‐coated PE tubes exhibited high protein and platelet resistance in vitro, and high platelet resistance ex vivo. The improved hemocompatibility is attributed to the unique chemical structure of RFGD tetraglyme that makes it highly protein resistant. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
- 21 July 2005
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 74A (4) , 722-738
The role of adsorbed fibrinogen in platelet adhesion to polyurethane surfaces: A comparison of surface hydrophobicity, protein adsorption, monoclonal antibody binding, and platelet adhesion
Ten specially synthesized polyurethanes (PUs) were used to investigate the effects of surface properties on platelet adhesion. Surface composition and hydrophilicity, fibrinogen (Fg) and von Willebrand's factor (vWf) adsorption, monoclonal anti‐Fg binding, and platelet adhesion were measured. PUs preadsorbed with afibrinogenemic plasma or serum exhibited very low platelet adhesion, while adhesion after preadsorption with vWf deficient plasma was not reduced, showing that Fg is the key plasma protein mediating platelet adhesion under static conditions. Platelet adhesion to the ten PUs after plasma preadsorption varied greatly, but was only partially consistent with Fg adsorption. Thus, while very hydrophilic PU copolymers containing PEG that had ultralow Fg adsorption also had very low platelet adhesion, some of the more hydrophobic PUs had relatively high Fg adsorption but still exhibited lower platelet adhesion. To examine why some PUs with high Fg adsorption had lower platelet adhesion, three monoclonal antibodies (mAbs) that bind to sites in Fg thought to mediate platelet adhesion were used. The antibodies were: M1, specific to γ‐chain C‐terminal; and R1 and R2, specific to RGD containing regions in the α‐chain N‐ and C‐terminal, respectively. Platelet adhesion was well correlated with M1 binding, but not with R1 or R2 binding. When these mAbs were incubated with plasma preadsorbed surfaces, they blocked adhesion to variable degrees. The ability of the R1 and R2 mAbs to partially block adhesion to adsorbed Fg suggests that RGD sites in the alpha chain may also be involved in mediating platelet adhesion and act synergistically with the C‐terminal of the γ‐chain. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
- 21 July 2005
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 74A (4) , 722-738
The role of adsorbed fibrinogen in platelet adhesion to polyurethane surfaces: A comparison of surface hydrophobicity, protein adsorption, monoclonal antibody binding, and platelet adhesion
Ten specially synthesized polyurethanes (PUs) were used to investigate the effects of surface properties on platelet adhesion. Surface composition and hydrophilicity, fibrinogen (Fg) and von Willebrand's factor (vWf) adsorption, monoclonal anti‐Fg binding, and platelet adhesion were measured. PUs preadsorbed with afibrinogenemic plasma or serum exhibited very low platelet adhesion, while adhesion after preadsorption with vWf deficient plasma was not reduced, showing that Fg is the key plasma protein mediating platelet adhesion under static conditions. Platelet adhesion to the ten PUs after plasma preadsorption varied greatly, but was only partially consistent with Fg adsorption. Thus, while very hydrophilic PU copolymers containing PEG that had ultralow Fg adsorption also had very low platelet adhesion, some of the more hydrophobic PUs had relatively high Fg adsorption but still exhibited lower platelet adhesion. To examine why some PUs with high Fg adsorption had lower platelet adhesion, three monoclonal antibodies (mAbs) that bind to sites in Fg thought to mediate platelet adhesion were used. The antibodies were: M1, specific to γ‐chain C‐terminal; and R1 and R2, specific to RGD containing regions in the α‐chain N‐ and C‐terminal, respectively. Platelet adhesion was well correlated with M1 binding, but not with R1 or R2 binding. When these mAbs were incubated with plasma preadsorbed surfaces, they blocked adhesion to variable degrees. The ability of the R1 and R2 mAbs to partially block adhesion to adsorbed Fg suggests that RGD sites in the alpha chain may also be involved in mediating platelet adhesion and act synergistically with the C‐terminal of the γ‐chain. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
- 20 May 2005
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 74A (1) , 69-83
Fibrinogen and von Willebrand's factor adsorption are both required for platelet adhesion from sheared suspensions to polyethylene preadsorbed with blood plasma
Previous studies showed that platelet adhesion to biomaterials from static suspensions was greatly increased by the adsorption of even very small amounts (2) of fibrinogen (Fg). In this study, the sensitivity of platelet adhesion to Fg was reexamined by measuring platelet adhesion under flow conditions. The role of adsorbed von Willebrand's factor (vWf) was also studied. Polyethylene (PE) tubing was preadsorbed with Fg, vWf, vWf‐deficient plasma, and Fg‐deficient plasma or serum with added Fg, and Fg adsorption measured with 125I Fg. Platelets in a red blood cell suspension were passed through the tubes at either low (50 s−1) or high (500 or 1000 s−1) shear rates and adhesion measured with an improved LDH assay. Adhesion from flowing suspensions measured after preadsorption with afibrinogenemic plasma or serum was very low, but increased greatly with addition of Fg. Less than 10 ng/cm2 of adsorbed Fg was enough to greatly enhance platelet adhesion. Adhesion at high shear was also strongly affected by vWf, as platelet adhesion at 500 s−1 to PE preadsorbed with vWf‐deficient plasma decreased by more than tenfold compared to adhesion at 50 s−1, but platelet adhesion to PE preadsorbed with normal plasma increased about eightfold when shear rate was increased. The results show that very low amounts of adsorbed Fg are able to support platelet adhesion under shear flow. However, adsorbed vWf also appears to play an important cofactor role in platelet adhesion to biomaterials, as its presence greatly augments platelet adhesion under high shear. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
- 20 May 2005
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 74A (1) , 69-83
Fibrinogen and von Willebrand's factor adsorption are both required for platelet adhesion from sheared suspensions to polyethylene preadsorbed with blood plasma
Previous studies showed that platelet adhesion to biomaterials from static suspensions was greatly increased by the adsorption of even very small amounts (2) of fibrinogen (Fg). In this study, the sensitivity of platelet adhesion to Fg was reexamined by measuring platelet adhesion under flow conditions. The role of adsorbed von Willebrand's factor (vWf) was also studied. Polyethylene (PE) tubing was preadsorbed with Fg, vWf, vWf‐deficient plasma, and Fg‐deficient plasma or serum with added Fg, and Fg adsorption measured with 125I Fg. Platelets in a red blood cell suspension were passed through the tubes at either low (50 s−1) or high (500 or 1000 s−1) shear rates and adhesion measured with an improved LDH assay. Adhesion from flowing suspensions measured after preadsorption with afibrinogenemic plasma or serum was very low, but increased greatly with addition of Fg. Less than 10 ng/cm2 of adsorbed Fg was enough to greatly enhance platelet adhesion. Adhesion at high shear was also strongly affected by vWf, as platelet adhesion at 500 s−1 to PE preadsorbed with vWf‐deficient plasma decreased by more than tenfold compared to adhesion at 50 s−1, but platelet adhesion to PE preadsorbed with normal plasma increased about eightfold when shear rate was increased. The results show that very low amounts of adsorbed Fg are able to support platelet adhesion under shear flow. However, adsorbed vWf also appears to play an important cofactor role in platelet adhesion to biomaterials, as its presence greatly augments platelet adhesion under high shear. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005
- 27 July 2004
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 70A (4) , 533-541
Effects of adsorbed proteins and surface chemistry on foreign body giant cell formation, tumor necrosis factor alpha release and procoagulant activity of monocytes
The adhesion and activation of monocytes and macrophages are thought to affect the foreign body response to implanted medical devices. However, these cells interact with devices indirectly, because of the prior adsorption of proteins. Therefore, we preadsorbed several “model” biomaterial surfaces with proteins and then measured foreign body giant cell (FBGC) formation, tumor necrosis factor alpha (TNFα) release, and procoagulant activity. The model surfaces were tissue culture polystyrene (TCPS), untreated polystyrene (PS), and Primaria, whereas the proteins used were albumin, fibronectin, fibrinogen, and immunoglobulin. FBGC formation, TNFα release, and procoagulant activity of monocytes were the highest for surfaces preadsorbed with IgG. FBGC formation was lower on surfaces with adsorbed fibrinogen and fibronectin than on uncoated surfaces. TNFα release and procoagulant activity of monocytes were similar on surface adsorbed with fibrinogen, fibronectin, or albumin. Monocyte activation was also affected by the surface chemistry of the substrates, because FBGC formation was the highest on PS and the lowest on TCPS. Monocyte procoagulant activity was the highest on Primaria. Adsorbed proteins and surface chemistry were found to have strong effects on FBGC formation, monocyte TNFα release, and procoagulant activityin vitro, providing support for the idea that these same variables could affect macrophage‐mediated foreign body response to biomaterialsin vivo. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 70A: 533–541, 2004
- 27 July 2004
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 70A (4) , 533-541
Effects of adsorbed proteins and surface chemistry on foreign body giant cell formation, tumor necrosis factor alpha release and procoagulant activity of monocytes
The adhesion and activation of monocytes and macrophages are thought to affect the foreign body response to implanted medical devices. However, these cells interact with devices indirectly, because of the prior adsorption of proteins. Therefore, we preadsorbed several “model” biomaterial surfaces with proteins and then measured foreign body giant cell (FBGC) formation, tumor necrosis factor alpha (TNFα) release, and procoagulant activity. The model surfaces were tissue culture polystyrene (TCPS), untreated polystyrene (PS), and Primaria, whereas the proteins used were albumin, fibronectin, fibrinogen, and immunoglobulin. FBGC formation, TNFα release, and procoagulant activity of monocytes were the highest for surfaces preadsorbed with IgG. FBGC formation was lower on surfaces with adsorbed fibrinogen and fibronectin than on uncoated surfaces. TNFα release and procoagulant activity of monocytes were similar on surface adsorbed with fibrinogen, fibronectin, or albumin. Monocyte activation was also affected by the surface chemistry of the substrates, because FBGC formation was the highest on PS and the lowest on TCPS. Monocyte procoagulant activity was the highest on Primaria. Adsorbed proteins and surface chemistry were found to have strong effects on FBGC formation, monocyte TNFα release, and procoagulant activityin vitro, providing support for the idea that these same variables could affect macrophage‐mediated foreign body response to biomaterialsin vivo. © 2004 Wiley Periodicals, Inc. J Biomed Mater Res 70A: 533–541, 2004
- 5 November 2003
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 67A (4) , 1255-1268
Variations in the ability of adsorbed fibrinogen to mediate platelet adhesion to polystyrene‐based materials: A multivariate statistical analysis of antibody binding to the platelet binding sites of fibrinogen
Platelet adhesion to the surfaces of biomaterials preadsorbed with plasma previously has been shown to be mediated exclusively by surface‐bound fibrinogen and does not seem to involve the other adhesion proteins in plasma (Tsai et al., J Biomed Mater Res 2002;60:348–359). In this study, the influence of surface‐bound fibrinogen on platelet adhesion to five different types of polystyrene‐based microtiter plates preadsorbed with plasma was analyzed relative to the amount of adsorbed fibrinogen and monoclonal antibody binding to the adsorbed fibrinogen. There was no significant correlation between platelet adhesion and the absolute amount of adsorbed fibrinogen. However, platelet adhesion was positively correlated to the ability of the adsorbed fibrinogen to bind three types of monoclonal antibodies. The antibodies used bound to the sites on fibrinogen thought to be involved in platelet binding (the two γ chain C‐terminal dodecapeptides and the RGDF and RGDS sequences in each of the Aα chains). A partial least‐squares calibration model was used to analyze the relative importance of these binding sites in fibrinogen to platelet adhesion. The γ chain C‐terminal dodecapeptide was shown to be the most important site in adsorbed fibrinogen in mediating platelet adhesion. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1255–1268, 2003
- 5 November 2003
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 67A (4) , 1255-1268
Variations in the ability of adsorbed fibrinogen to mediate platelet adhesion to polystyrene‐based materials: A multivariate statistical analysis of antibody binding to the platelet binding sites of fibrinogen
Platelet adhesion to the surfaces of biomaterials preadsorbed with plasma previously has been shown to be mediated exclusively by surface‐bound fibrinogen and does not seem to involve the other adhesion proteins in plasma (Tsai et al., J Biomed Mater Res 2002;60:348–359). In this study, the influence of surface‐bound fibrinogen on platelet adhesion to five different types of polystyrene‐based microtiter plates preadsorbed with plasma was analyzed relative to the amount of adsorbed fibrinogen and monoclonal antibody binding to the adsorbed fibrinogen. There was no significant correlation between platelet adhesion and the absolute amount of adsorbed fibrinogen. However, platelet adhesion was positively correlated to the ability of the adsorbed fibrinogen to bind three types of monoclonal antibodies. The antibodies used bound to the sites on fibrinogen thought to be involved in platelet binding (the two γ chain C‐terminal dodecapeptides and the RGDF and RGDS sequences in each of the Aα chains). A partial least‐squares calibration model was used to analyze the relative importance of these binding sites in fibrinogen to platelet adhesion. The γ chain C‐terminal dodecapeptide was shown to be the most important site in adsorbed fibrinogen in mediating platelet adhesion. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res 67A: 1255–1268, 2003
- 6 February 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 60 (3) , 348-359
Platelet adhesion to polystyrene‐based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand's factor
Four plasma proteins have been shown to be able to mediate platelet adhesion to synthetic materials when they are adsorbed as purified proteins: fibrinogen (Fg), fibronectin (Fn), vitronectin (Vn), and von Willebrand factor (vWF). Among them, Fg is thought to play a leading role in mediating platelet adhesion to plasma‐preadsorbed biomaterials, but this has been established for only three types of materials so far in our laboratory. Furthermore, the role of Fn, Vn, and vWF in mediating platelet adhesion to plasma‐preadsorbed surfaces is still unclear. The aim of the current study was to assess the importance of Fg, Fn, Vn, and vWF in mediating platelet adhesion to a series of polystyrene‐based surfaces. The strategy applied in the present investigation was to compare platelet adhesion to surfaces preadsorbed with normal plasma, plasma selectively depleted in Fn or Vn or both Fn and Vn, plasma from donors who were genetically deficient in vWF, and serum. Few platelets adhered to the surfaces preadsorbed with serum, whereas depletion of Fn, Vn, or vWF from plasma did not decrease platelet adhesion significantly. Replenishment of exogenous Fg to serum before protein adsorption restored platelet adhesion to the surfaces, suggesting that Fg was the major plasma protein that mediated platelet adhesion. Also, we found that a surface density of adsorbed Fg far below the amount that usually adsorbs to synthetic surfaces was sufficient to support full‐scale platelet adhesion. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 348–359, 2002; DOI 10.1002/jbm.10048
- 6 February 2002
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 60 (3) , 348-359
Platelet adhesion to polystyrene‐based surfaces preadsorbed with plasmas selectively depleted in fibrinogen, fibronectin, vitronectin, or von Willebrand's factor
Four plasma proteins have been shown to be able to mediate platelet adhesion to synthetic materials when they are adsorbed as purified proteins: fibrinogen (Fg), fibronectin (Fn), vitronectin (Vn), and von Willebrand factor (vWF). Among them, Fg is thought to play a leading role in mediating platelet adhesion to plasma‐preadsorbed biomaterials, but this has been established for only three types of materials so far in our laboratory. Furthermore, the role of Fn, Vn, and vWF in mediating platelet adhesion to plasma‐preadsorbed surfaces is still unclear. The aim of the current study was to assess the importance of Fg, Fn, Vn, and vWF in mediating platelet adhesion to a series of polystyrene‐based surfaces. The strategy applied in the present investigation was to compare platelet adhesion to surfaces preadsorbed with normal plasma, plasma selectively depleted in Fn or Vn or both Fn and Vn, plasma from donors who were genetically deficient in vWF, and serum. Few platelets adhered to the surfaces preadsorbed with serum, whereas depletion of Fn, Vn, or vWF from plasma did not decrease platelet adhesion significantly. Replenishment of exogenous Fg to serum before protein adsorption restored platelet adhesion to the surfaces, suggesting that Fg was the major plasma protein that mediated platelet adhesion. Also, we found that a surface density of adsorbed Fg far below the amount that usually adsorbs to synthetic surfaces was sufficient to support full‐scale platelet adhesion. © 2002 Wiley Periodicals, Inc. J Biomed Mater Res 60: 348–359, 2002; DOI 10.1002/jbm.10048
- 26 July 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 57 (3) , 336-345
The effects of surface chemistry and adsorbed proteins on monocyte/macrophage adhesion to chemically modified polystyrene surfaces
Monocytes and macrophages play critical roles in inflammatory responses to implanted biomaterials. Monocyte adhesion may lead to macrophage activation and the foreign body response. We report that surface chemistry, preadsorbed proteins, and adhesion time all play important roles during monocyte adhesion in vitro. The surface chemistry of tissue culture polystyrene (TCPS), polystyrene, Primaria®, and ultra low attachment (ULA) used for adhesion studies was characterized by electron spectroscopy for chemical analysis. Fibrinogen adsorption measured by 125I-labeled fibrinogen was the lowest on ULA, higher on TCPS, and the highest on polystyrene or Primaria. Monocyte adhesion on protein preadsorbed surfaces for 2 h or 1 day was measured with a lactate-dehydrogenase method. Monocyte adhesion decreased over time. The ability of preadsorbed proteins to modulate monocyte adhesion was surface dependent. Adhesion was the lowest on ULA, higher and similar on TCPS or polystyrene, and the highest on Primaria. Monocyte adhesion on plasma or fibrinogen adsorbed surfaces correlated positively and linearly to the amount of adsorbed fibrinogen. Preadsorbed fibronectin, immunoglobulin G, plasma, or serum also promoted adhesion compared with albumin preadsorbed or uncoated surfaces. Overall, biomaterial surface chemistry, the type and amount of adsorbed proteins, and adhesion time all affected monocyte adhesion in vitro. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 57: 336–345, 2001
- 26 July 2001
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 57 (3) , 336-345
The effects of surface chemistry and adsorbed proteins on monocyte/macrophage adhesion to chemically modified polystyrene surfaces
Monocytes and macrophages play critical roles in inflammatory responses to implanted biomaterials. Monocyte adhesion may lead to macrophage activation and the foreign body response. We report that surface chemistry, preadsorbed proteins, and adhesion time all play important roles during monocyte adhesion in vitro. The surface chemistry of tissue culture polystyrene (TCPS), polystyrene, Primaria®, and ultra low attachment (ULA) used for adhesion studies was characterized by electron spectroscopy for chemical analysis. Fibrinogen adsorption measured by 125I-labeled fibrinogen was the lowest on ULA, higher on TCPS, and the highest on polystyrene or Primaria. Monocyte adhesion on protein preadsorbed surfaces for 2 h or 1 day was measured with a lactate-dehydrogenase method. Monocyte adhesion decreased over time. The ability of preadsorbed proteins to modulate monocyte adhesion was surface dependent. Adhesion was the lowest on ULA, higher and similar on TCPS or polystyrene, and the highest on Primaria. Monocyte adhesion on plasma or fibrinogen adsorbed surfaces correlated positively and linearly to the amount of adsorbed fibrinogen. Preadsorbed fibronectin, immunoglobulin G, plasma, or serum also promoted adhesion compared with albumin preadsorbed or uncoated surfaces. Overall, biomaterial surface chemistry, the type and amount of adsorbed proteins, and adhesion time all affected monocyte adhesion in vitro. © 2001 John Wiley & Sons, Inc. J Biomed Mater Res 57: 336–345, 2001