YLYaxiong Liu

Yaxiong Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yaxiong Liu has a total of 48 co-authors. Here are the top co-authors by number of shared publications:

  • Dichen Li

    School of Mechanical Engineering, Xi'an Jiaotong University

    7 shared publications
  • Zhongmin Jin

    State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710054, PR China; Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, LS29JT, UK

    7 shared publications
  • Jiankang He

    State Key Laboratory for Manufacturing Systems Engineering, Xi’an Jiaotong University, Xi’an 710049, People’s Republic of China

    6 shared publications
  • Dichen Li

    State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710054, PR China

    2 shared publications
  • Feng Ma

    2 shared publications
  • Jiankang He

    State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an 710054, PR China

    2 shared publications

Latest Publications

  • Open Access

    The Emerging Frontiers and Applications of High-Resolution 3D Printing

    by Mao Mao, Jiankang He, Xiao Li, Bing Zhang, Qi Lei, Yaxiong Liu, Dichen Li

    Over the past few decades, there has been an increasing interest in the fabrication of complex high-resolution three-dimensional (3D) architectures at micro/nanoscale. These architectures can be obtained through conventional microfabrication methods including photolithography, electron-beam lithography, femtosecond laser lithography, nanoimprint lithography, etc. However, the applications of these fabrication methods are limited by their high costs, the generation of various chemical wastes, and their insufficient ability to create high-aspect-ratio 3D structures. High-resolution 3D printing has recently emerged as a promising solution, as it is capable of building multifunctional 3D constructs with optimal properties. Here we present a review on the principles and the recent advances of high-resolution 3D printing techniques, including two-photon polymerization (TPP), projection microstereoLithography (PµSL), direct ink writing (DIW) and electrohydrodynamic printing (EHDP). We also highlight their typical applications in various fields such as metamaterials, energy storage, flexible electronics, microscale tissue engineering scaffolds and organ-on-chips. Finally, we discuss the challenge and perspective of these high-resolution 3D printing techniques in technical and application aspects. We believe that high-resolution 3D printing will eventually revolutionize the microfabrication processes of 3D architectures with high product quality and diversified materials. It will also find applications in a wide scope.


  • Design and optimization of the fixing plate for customized mandible implants

    by Mian Qin, Yaxiong Liu, Ling Wang, Jiankang He, Ming Xuan, Chengge Hua, Dichen Li, Zhongmin Jin, Xiaoyi Wang


    • 1 December 2014
      • Vol. 28  (12) , 1551-4

    [research status and application of magnetic compression anastomosis in surgery].

    by Hongchang Guo, Guangbin Zhao, Yaxiong Liu, Guangshen Xu, Xiaopeng Yan, Fei Xue, Feng Ma, Yi Lü, Dichen Li

    To summarize the recent development of the magnetic compression anastomosis in surgery. The abroad and domestic relevant literature about magnetic compression anastomosis was extensively reviewed, and comprehensive analyzed. Magnetic compression anastomosis in the reconstruction of the body lumen is a simple and effective way; laparoscopy combined with magnetic compression anastomosis has the advantages of small wound and quick recovery. Magnetic compression anastomosis has been increasingly used in clinical practice. But its mechanism has not been fully revealed, and it is difficulty in expelling out of the magnet for the gastrointestinal and certain large-size lumen, so further research and optimization are still needed. Relative to the traditional manual suture, magnetic anastomosis has great advantage, especially a combination of magnetic compression anastomosis and minimally invasive surgery has bright prospects for development.


    • 1 November 2014
      • Vol. 28  (11) , 1428-30

    [Research status and future of in situ three-dimensional printing technique].

    by Dong Chen, Yaxiong Liu, Jiankang He, Zhen Wang, Lei Ma, Zhongmin Jin

    To review the current research status of in situ three-dimensional (3-D) printing technique and future trends. Recent related literature about in situ 3-D printing technique was summarized, reviewed, and analyzed. Based on the clinical need for surgical repair, in situ 3-D printing technique is in the preliminary study, mainly focuses on in situ dermal repair and bone and cartilage repair, and succeeds in experiments, but there are still a lot of problems for clinical application. With the development of in situ 3-D printing technique, it will provide patients with real-time and in situ digital design and 3-D printing treatment with a timely and minimally invasive surgical repair process. It will be widely used in the future.

    • 1 March 2014
      • Vol. 28  (3) , 286-91

    [Application of digital design and three-dimensional printing technique on individualized medical treatment].

    by Mian Qin, Yaxiong Liu, Jiankang He, Ling Wang, Qin Lian, Dichen Li, Zhongmin Jin, Sanhu He, Gang Li, Yanpu Liu, et al.

    To summarize the latest research development of the application of digital design and three-dimensional (3-D) printing technique on individualized medical treatment. Recent research data and clinical literature about the application of digital design and 3-D printing technique on individualized medical treatment in Xi'an Jiaotong University and its cooperation unit were summarized, reviewed, and analyzed. Digital design and 3-D printing technique can design and manufacture individualized implant based on the patient's specific disease conditions. And the implant can satisfy the needs of specific shape and function of the patient, reducing dependence on the level of experience required for the doctor. So 3-D printing technique get more and more recognition of the surgeon on the individualized repair of human tissue. Xi'an Jiaotong University is the first unit to develop the commercial 3-D printer and conduct depth research on the design and manufacture of individualized medical implant. And complete technological processes and quality standards of product have been developed. The individualized medical implant manufactured by 3-D printing technique can not only achieve personalized match but also meet the functional requirements and aesthetic requirements of patients. In addition, the individualized medical implant has the advantages of accurate positioning, stable connection, and high strength. So 3-D printing technique has broad prospects in the manufacture and application of individualized implant.


    • 1 March 2014
      • Vol. 28  (3) , 314-7

    [Fabrication and in vivo implantation of ligament-bone composite scaffolds based on three-dimensional printing technique].

    by Wenyou Zhang, Jiankang He, Xiang Li, Yaxiong Liu, Weiguo Bian, Dichen Li, Zhongmin Jin

    To solve the fixation problem between ligament grafts and host bones in ligament reconstruction surgery by using ligament-bone composite scaffolds to repair the ligaments, to explore the fabrication method for ligament-bone composite scaffolds based on three-dimensional (3-D) printing technique, and to investigate their mechanical and biological properties in animal experiments. The model of bone scaffolds was designed using CAD software, and the corresponding negative mould was created by boolean operation. 3-D printing techinique was employed to fabricate resin mold. Ceramic bone scaffolds were obtained by casting the ceramic slurry in the resin mould and sintering the dried ceramics-resin composites. Ligament scaffolds were obtained by weaving degummed silk fibers, and then assembled with bone scaffolds and bone anchors. The resultant ligament-bone composite scaffolds were implanted into 10 porcine left anterior cruciate ligament rupture models at the age of 4 months. Mechanical testing and histological examination were performed at 3 months postoperatively, and natural anterior cruciate ligaments of the right sides served as control. Biomechanical testing showed that the natural anterior cruciate ligament of control group can withstand maximum tensile force of (1 384 +/- 181) N and dynamic creep of (0.74 +/- 0.21) mm, while the regenerated ligament-bone scaffolds of experimental group can withstand maximum tensile force of (370 +/- 103) N and dynamic creep of (1.48 +/- 0.49) mm, showing significant differences (t = 11.617, P = 0.000; t = 2.991, P = 0.020). In experimental group, histological examination showed that new bone formed in bone scaffolds. A hierarchical transition structure regenerated between ligament-bone scaffolds and the host bones, which was similar to the structural organizations of natural ligament-bone interface. Ligament-bone composite scaffolds based on 3-D printing technique facilitates the regeneration of biomimetic ligament-bone interface. It is expected to achieve physical fixation between ligament grafts and host bone.


    • 1 March 2014
      • Vol. 28  (3) , 318-24

    [Cartilage repair and subchondral bone reconstruction based on three-dimensional printing technique].

    by Weijie Zhang, Qin Lian, Dichen Li, Kunzheng Wang, Zhongmin Jin, Weiguo Bian, Yaxiong Liu, Jiankang He, Ling Wang

    To investigate whether subchondral bone microstructural parameters are related to cartilage repair during large osteochondral defect repairing based on three-dimensional (3-D) printing technique. Biomimetic biphasic osteochondral composite scaffolds were fabricated by using 3-D printing technique. The right trochlea critical sized defects (4.8 mm in diameter, 7.5 mm in depth) were created in 40 New Zealand white rabbits (aged 6 months, weighing 2.5-3.5 kg). Biomimetic biphasic osteochondral composite scaffolds were implanted into the defects in the experimental group (n = 35), and no composite scaffolds implantation served as control group (n = 5); the left side had no defect as sham-operation group. Animals of experimental and sham-operation groups were euthanized at 1, 2, 4, 8, 16, 24, and 52 weeks after operation, while animals of control group were sampled at 24 weeks. Subchondral bone microstructural parameters and cartilage repair were quantitatively analyzed using Micro-CT and Wayne scoring system. Correlation analysis and regression analysis were applied to reveal the relationship between subchondral bone parameters and cartilage repair. The subchondral bone parameters included bone volume fraction (BV/TV), bone surface area fraction (BSA/BV), trabecular thickness (Tb.Th), trabecular number (Tb.N), and trabecular spacing (Tb.Sp). In the experimental group, articular cartilage repair was significantly improved at 52 weeks postoperatively, which was dominated by hyaline cartilage tissue, and tidal line formed. Wayne scores at 24 and 52 weeks were significantly higher than that at 16 weeks in the experimental group (P < 0.05), but no significant difference was found between at 24 and 52 weeks (P > 0.05); the scores of experimental group were significantly lower than those of sham-operation group at all time points (P < 0.05). In the experimental group, new subchondral bone migrated from the surrounding defect to the centre, and subchondral bony plate formed at 24 and 52 weeks. The microstructural parameters of repaired subchondral bone followed a "twin peaks" like discipline to which BV/TV, BSA/BV, and Tb.N increased at 2 and 16 weeks, and then they returned to normal level. The Tb.Sp showed reversed discipline compared to the former 3 parameters, no significant change was found for Tb.Th during the repair process. Correlation analysis showed that BV/TV, BSA/BV, Tb.Th, Tb.N, and Tb.Sp were all related with gross appearance score and histology score of repaired cartilage. Subchondral bone parameters are related with cartilage repair in critical size osteochondral repair in vivo. Microstructural parameters of repaired subchondral bone follow a "twin peaks" like discipline (osteoplasia-remodeling-osteoplasia-remodeling) to achieve reconstruction, 2nd week and 16th week are critical time points for subchondral bone functional restoration.

    • 1 March 2014
      • Vol. 28  (3) , 325-30

    [Construction of large block of engineered liver tissue seeded with co-cultured cells and in vivo implantation research].

    by Xiaoli Qu, Min Wang, Jiankang He, Yaxiong Liu, Xinmin Zhou, Dichen Li, Zhongmin Jin

    To construct large block of engineered liver tissue by co-culture of fibroblasts and hepatocytes on collagen hydrogels in vitro and do in vivo implantation research. Silastic mould was prepared using three-dimensional printing technology. The collagen hydrogel scaffold was prepared by collagen hydrogel gel in the silicone mould and was removed. Sprague Dawley rat lung fibroblasts were co-cultured with primary hepatocytes at a ratio of 0.4 : 1 on the collagen hydrogel scaffold to construct large block of engineered liver tissue in vitro (group B), and primary hepatocytes cultured on the collagen hydrogel scaffold served as control group (group A). The cell morphology was observed, and the liver function was tested at 1, 3, 7, 14, and 21 days after culture. The rat model (n = 24) of hepatic cirrhosis was made by subcutaneous injection of carbon tetrachloride. And in vivo implantation study was carried in cirrhosis rat model. The phenotypic characteristics and functional expression of hepatocytes were evaluated at 3, 7, 14, 21, and 28 days after implantation. In vitro results indicated that hepatocytes in group B exhibited compact polyhedral cells with round nuclei and high expression of liver function. Moreover, cells aggregated to the most at 7 days. Album production and urea synthesis incresed significantly when compared with group A (P < 0.05). In vivo results showed hepatocytes in group B survived for 28 days, and albumin production and urea synthesis were significantly increased. In addition, hepatocytes showed an aggregated distribution and cord-like structures, which was similar to normal liver tissue. The large block of engineered liver tissue constructed by co-cultured cells can form tissue similar to normal liver tissue in vivo, and survive for a long time, laying foundations for building more complete engineered liver tissue in the future.

    • 1 March 2014
      • Vol. 38  (2) , 107-9

    [The development of the system of blood flow block by using magnetic compression abdominal large vascular].

    by Xiaopeng Yan, Yi Lv, Feng Ma, Jia Ma, Haohua Wang, Shanpei Wang, Dichen Li, Yaxiong Liu, Shenli Jia, Zongqian Shi, et al.

    A new system of blood flow block for control of bleeding in abdominal operation is composed of an abdominal magnetic blocking unit, an abdominal external electromagnet unit and other non-magnetic operation instrument. The abdominal external electromagnetic unit is placed in advance in the operation bed. The abdominal magnetic blocking unit can be placed directly on the ventral of the large vessels when need to blocking the abdominal large vessels during the operation. According to the non-contact suction characteristics of magnetic materials, the two magnetic units will attract each other and compression the vessels. Using this system for vascular occlusion does not need clear exposure and without separating vessel. There is the advantage of rapid, accurate and reliable for the system.

  • Biomaterial scaffolds with biomimetic fluidic channels for hepatocyte culture

    by Xiao Li, Jiankang He, Yaxiong Liu, Qian Zhao, Wanquan Wu, Dichen Li, Zhongmin Jin