Mohammad Ali Taher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Latest Publications
- 23 August 2001
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (8) , 969-973
Flame Atomic Absorption Spectrometric Determination of Trace Amounts of Manganese in Alloys and Biological Samples after Preconcentration with the Ion Pair of 2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol and Ammonium Tetraphenylborate on Microcrystalline Naphthalene or by Column Method
Manganese is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 7.5-10.5 from large volumes of aqueous solutions of various samples. After filtration, each solid mass consisting of the manganese complex and naphthalene was dissolved with 5 ml of dimethylformamide and the metal was determined by flame atomic absorption spectrometry. Manganese complex can alternatively be quantitatively adsorbed on ammonium tetraphenylborate-naphthalene adsorbent packed in a column and determined similarly. About 0.1 microgram of manganese can be concentrated in a column from 500 ml of aqueous sample, where its concentration is as low as 0.2 ppb. Eight replicate determinations of 1.0 ppm of manganese gave a mean absorbance of 0.224 with a relative standard deviation of 1.8%. The sensitivity for 1% absorption was 19 ppb. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of manganese in various standard samples.
- 23 August 2001
- Published by Springer Nature in Analytical Sciences
- Vol. 17 (8) , 969-973
Flame Atomic Absorption Spectrometric Determination of Trace Amounts of Manganese in Alloys and Biological Samples after Preconcentration with the Ion Pair of 2-(5-Bromo-2-pyridylazo)-5-diethylaminophenol and Ammonium Tetraphenylborate on Microcrystalline Naphthalene or by Column Method
Manganese is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 7.5-10.5 from large volumes of aqueous solutions of various samples. After filtration, each solid mass consisting of the manganese complex and naphthalene was dissolved with 5 ml of dimethylformamide and the metal was determined by flame atomic absorption spectrometry. Manganese complex can alternatively be quantitatively adsorbed on ammonium tetraphenylborate-naphthalene adsorbent packed in a column and determined similarly. About 0.1 microgram of manganese can be concentrated in a column from 500 ml of aqueous sample, where its concentration is as low as 0.2 ppb. Eight replicate determinations of 1.0 ppm of manganese gave a mean absorbance of 0.224 with a relative standard deviation of 1.8%. The sensitivity for 1% absorption was 19 ppb. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of manganese in various standard samples.
- 4 October 2000
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 368 (4) , 421-423
Flame atomic absorption spectrometric determination of trace chromium in various standard samples after preconcentration with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol
Chromium can be quantitatively retained as 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-tetraphenylborate(TPB) complex onto microcrystalline naphthalene in the pH range 4.8–5.9 from a large volume of aqueous solutions of various standard samples. After filtration, the solid mass consisting of the chromium complex and naphthalene was dissolved with 5 mL of dimethylformamide and the metal was determined by air-acetylene FAAS. A detection limit of ¶4 ng/mL for chromium was established. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of chromium in various standard alloys and biological samples.
- 4 October 2000
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 368 (4) , 421-423
Flame atomic absorption spectrometric determination of trace chromium in various standard samples after preconcentration with 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol
Chromium can be quantitatively retained as 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)-tetraphenylborate(TPB) complex onto microcrystalline naphthalene in the pH range 4.8–5.9 from a large volume of aqueous solutions of various standard samples. After filtration, the solid mass consisting of the chromium complex and naphthalene was dissolved with 5 mL of dimethylformamide and the metal was determined by air-acetylene FAAS. A detection limit of ¶4 ng/mL for chromium was established. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of chromium in various standard alloys and biological samples.
- 5 September 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (10) , 1865-1868
Atomic absorption spectrometric determination of trace zinc in alloys and biological samples after preconcentration with [1-(2-pyridylazo)-2-naphthol] on microcrystalline naphthalene
An atomic absorption spectrometric method for the determination of trace amounts of zinc after adsorption of its [1-(2-pyridylazo)-2-naphthol] complex on microcrystalline naphthalene has been developed. This complex is adsorbed on microcrystalline naphthalene in the pH range 3.5–7.5 from large volumes of aqueous solutions of various alloys and biological samples with a preconcentration factor of 40. After filtration, the solid mass consisting of the zinc complex and naphthalene was dissolved with 5 ml of dimethylformamide and the metal was determined by flame atomic absorption spectrometry. Zinc can alternatively be quantitatively adsorbed on [1-(2-pyridylazo)-2-naphthol]–naphthalene adsorbent packed in a column and determined similarly. About 0.5 ng of zinc can be concentrated in a column from 200 ml of aqueous sample, where its concentration is as low as 2.5 pg ml−1. The calibration curve is linear in the range 0.1–6.5 ng ml−1 in dimethylformamide solution. Eight replicate determinations of 2 ng ml−1 of zinc gave a mean absorbance of 0.145 with a relative standard deviation of 1.5%. The sensitivity for 1% absorption was 0.061 ng ml−1. Various parameters, such as the effect of pH and the interference of a number of metal ions on the determination of zinc, have been studied in detail to optimize the conditions for the determination of zinc in various standard complex materials.
- 5 September 2000
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 125 (10) , 1865-1868
Atomic absorption spectrometric determination of trace zinc in alloys and biological samples after preconcentration with [1-(2-pyridylazo)-2-naphthol] on microcrystalline naphthalene
An atomic absorption spectrometric method for the determination of trace amounts of zinc after adsorption of its [1-(2-pyridylazo)-2-naphthol] complex on microcrystalline naphthalene has been developed. This complex is adsorbed on microcrystalline naphthalene in the pH range 3.5–7.5 from large volumes of aqueous solutions of various alloys and biological samples with a preconcentration factor of 40. After filtration, the solid mass consisting of the zinc complex and naphthalene was dissolved with 5 ml of dimethylformamide and the metal was determined by flame atomic absorption spectrometry. Zinc can alternatively be quantitatively adsorbed on [1-(2-pyridylazo)-2-naphthol]–naphthalene adsorbent packed in a column and determined similarly. About 0.5 ng of zinc can be concentrated in a column from 200 ml of aqueous sample, where its concentration is as low as 2.5 pg ml−1. The calibration curve is linear in the range 0.1–6.5 ng ml−1 in dimethylformamide solution. Eight replicate determinations of 2 ng ml−1 of zinc gave a mean absorbance of 0.145 with a relative standard deviation of 1.5%. The sensitivity for 1% absorption was 0.061 ng ml−1. Various parameters, such as the effect of pH and the interference of a number of metal ions on the determination of zinc, have been studied in detail to optimize the conditions for the determination of zinc in various standard complex materials.
- 26 April 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 15 (5) , 573-576
Atomic absorption spectrometric determination of trace amount of nickel in alloys and biological samples after preconcentration with the ion pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and ammonium tetraphenylborate on microcrystalline naphthalene or by column method
Nickel is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)–ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 9.0–10.5 from a large volume of aqueous solutions of various samples. After filtration, the solid mass consisting of the nickel complex and naphthalene was dissolved with 5 ml of dimethylformamide and the metal was determined by atomic absorption spectrometry. The nickel complex can alternatively be quantitatively adsorbed on ammonium tetraphenylborate–naphthalene adsorbent packed in a column and determined similarly. The calibration curve is linear at 0.30–18 ppm in dimethylformamide solution. Eight replicate determinations of 5.0 ppm of nickel gave a mean absorbance of 0.096 with a relative standard deviation of 1.5%. The sensitivity for 1% absorption was 0.23 µg ml–1. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of nickel in various standard samples.
- 26 April 2000
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 15 (5) , 573-576
Atomic absorption spectrometric determination of trace amount of nickel in alloys and biological samples after preconcentration with the ion pair of 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol and ammonium tetraphenylborate on microcrystalline naphthalene or by column method
Nickel is quantitatively retained on 2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (5-Br-PADAP)–ammonium tetraphenylborate with microcrystalline naphthalene or by a column method in the pH range 9.0–10.5 from a large volume of aqueous solutions of various samples. After filtration, the solid mass consisting of the nickel complex and naphthalene was dissolved with 5 ml of dimethylformamide and the metal was determined by atomic absorption spectrometry. The nickel complex can alternatively be quantitatively adsorbed on ammonium tetraphenylborate–naphthalene adsorbent packed in a column and determined similarly. The calibration curve is linear at 0.30–18 ppm in dimethylformamide solution. Eight replicate determinations of 5.0 ppm of nickel gave a mean absorbance of 0.096 with a relative standard deviation of 1.5%. The sensitivity for 1% absorption was 0.23 µg ml–1. The interference of a large number of anions and cations has been studied and the optimized conditions developed were utilized for the trace determination of nickel in various standard samples.
- 1 March 2000
- Published by Elsevier in Analytica Chimica Acta
- Vol. 408 (1-2) , 153-161
Determination of trace copper in biological and environmental samples by third derivative spectrophotometry after pre-concentration with the ion pair of nitroso-R and tetradecyldimethylbenzylammonium chloride on microcrystalline naphthalene
- 1 March 2000
- Published by Elsevier in Analytica Chimica Acta
- Vol. 408 (1-2) , 153-161
Determination of trace copper in biological and environmental samples by third derivative spectrophotometry after pre-concentration with the ion pair of nitroso-R and tetradecyldimethylbenzylammonium chloride on microcrystalline naphthalene