Nuran Özaltın
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nuran Özaltın has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Ceren Yardimci
Department of Analytical Chemistry, Faculty of Pharmacy, University of Hacettepe, 06100, Sihhiye, Ankara, Turkey
3 shared publicationsCeren Yardımcı
Department of Analytical Chemistry, Faculty of Pharmacy, Hacettepe University, 06100 Sihhiye, Ankara, Turkey
3 shared publicationsEmirhan Nemutlu
Department of Analytical Chemistry, Faculty of Pharmacy, University of Hacettepe, 06100 Ankara, Turkey
2 shared publicationsAlper Gürlek
Division of Endocrinology, Department of Internal Medicine, Faculty of Medicine, Hacettepe University, 06100 Sıhhıye, Ankara, Turkey
1 shared publicationE. Uçaktürk
Hacettepe University
1 shared publication- Incilay Suslu
Department of Analytical Chemistry, Faculty of Pharmacy, Hacettepe University, 06100 Ankara, Turkey
1 shared publication
Latest Publications
- 1 April 2019
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 55 (4) , 305-313
Voltammetric Determination of Cefuroxime Axetil in Pharmaceuticals Using Graphene Oxide Modified Glassy Carbon Electrode and Hanging Mercury Drop Electrode
Two novel, economic, rapid, simple, sensitive and selective square wave voltammetric (SWV) methods have been developed for the determination of cefuroxime axetil (CEFA) in pharmaceutical...
- 1 April 2019
- Published by Pleiades Publishing Ltd in Russian Journal of Electrochemistry
- Vol. 55 (4) , 305-313
Voltammetric Determination of Cefuroxime Axetil in Pharmaceuticals Using Graphene Oxide Modified Glassy Carbon Electrode and Hanging Mercury Drop Electrode
Two novel, economic, rapid, simple, sensitive and selective square wave voltammetric (SWV) methods have been developed for the determination of cefuroxime axetil (CEFA) in pharmaceutical...
- Open Access
- 1 April 2011
- Published by Walter de Gruyter GmbH in Reviews in Analytical Chemistry
- Vol. 30 (1) , 29-36
Adsorptive stripping voltammetric methods for determination of ezetimibe in tablets
In this study, square-wave adsorptive stripping voltammetry (SWAdSV) and differential pulse adsorptive stripping voltammetry (DPAdSV) were used for determination of ezetimibe (EZE) in the presence of 0.1 m K 2 HPO 4 –Na 2 B 4 O 7 (1:1) supporting electrolyte. The well-defined peaks for SWAdSV were observed at accumulation time of 15 s, accumulation potential of -0.80 V, frequency of 15 Hz, pulse amplitude of 25 mV, potential increment of 4 mV. For DPAdSV, accumulation time of 15 s, accumulation potential of -0.85 mV, scan rate of 20 mV/s and pulse amplitude of 50 mV were found as the best apparatus parameters. EZE gave rise to a single voltammetric peak in the potential interval from -1236 to -1252 mV for SWAdSV and interval from -1190 to -1210 mV for DPAdSV. The developed methods were validated according to the ICH guideline and were found to be linear, sensitive, specific, precise and accurate. The linearity ranges of EZE for SWAdSV and DPAdSV are 33–596 ng/ml and 66–400 ng/ml, respectively. The developed method was applied successfully for the determination of EZE in tablet dosage form.
- 1 April 2011
- Published by Walter de Gruyter GmbH in Reviews in Analytical Chemistry
- Vol. 30 (1) , 29-36
Open AccessAdsorptive stripping voltammetric methods for determination of ezetimibe in tablets
In this study, square-wave adsorptive stripping voltammetry (SWAdSV) and differential pulse adsorptive stripping voltammetry (DPAdSV) were used for determination of ezetimibe (EZE) in the presence of 0.1 m K 2 HPO 4 –Na 2 B 4 O 7 (1:1) supporting electrolyte. The well-defined peaks for SWAdSV were observed at accumulation time of 15 s, accumulation potential of -0.80 V, frequency of 15 Hz, pulse amplitude of 25 mV, potential increment of 4 mV. For DPAdSV, accumulation time of 15 s, accumulation potential of -0.85 mV, scan rate of 20 mV/s and pulse amplitude of 50 mV were found as the best apparatus parameters. EZE gave rise to a single voltammetric peak in the potential interval from -1236 to -1252 mV for SWAdSV and interval from -1190 to -1210 mV for DPAdSV. The developed methods were validated according to the ICH guideline and were found to be linear, sensitive, specific, precise and accurate. The linearity ranges of EZE for SWAdSV and DPAdSV are 33–596 ng/ml and 66–400 ng/ml, respectively. The developed method was applied successfully for the determination of EZE in tablet dosage form.
- 27 February 2009
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 39 (9) , 1535-1543
Square-wave adsorptive stripping voltammetric determination of candesartan cilexetil in pharmaceutical formulations
- 27 February 2009
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 39 (9) , 1535-1543
Square-wave adsorptive stripping voltammetric determination of candesartan cilexetil in pharmaceutical formulations
- 15 August 2007
- Published by Springer Nature in Chromatographia
- Vol. 66 (S1) , 87-91
Simultaneous Determination of Ezetimibe and Simvastatin in Pharmaceutical Formulations by Dual-Mode Gradient LC
- 15 August 2007
- Published by Springer Nature in Chromatographia
- Vol. 66 (S1) , 87-91
Simultaneous Determination of Ezetimibe and Simvastatin in Pharmaceutical Formulations by Dual-Mode Gradient LC
- 20 September 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 383 (5) , 833-838
Determination of magnesium, calcium, sodium, and potassium in blood plasma samples by capillary zone electrophoresis
A capillary zone electrophoretic assay has been developed and validated for analysis of magnesium, calcium, sodium, and potassium in blood plasma samples. Optimum results were obtained with 20 mmol L−1 imidazole (pH 2.8) and 0.5 mmol L−1 oxalic acid containing 5% methanol, capillary temperature 25°C, applied voltage 30 kV, hydrodynamic injection time 3 s, and a poly(vinyl alcohol)-coated capillary (i.d. 50 μm, total length 64.5 cm and effective length 56 cm). Indirect detection was performed at 214 nm. Cadmium was used as internal standard. The migration times of magnesium, calcium, sodium, and potassium were 4.25, 3.79, 3.96, and 2.79 min, respectively. The method was applied to the determination of magnesium, calcium, sodium, and potassium in blood plasma samples. The results were compared with those from atomic absorption spectrophotometry and no statistically significant difference was found (P>0.05).
- 20 September 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 383 (5) , 833-838
Determination of magnesium, calcium, sodium, and potassium in blood plasma samples by capillary zone electrophoresis
A capillary zone electrophoretic assay has been developed and validated for analysis of magnesium, calcium, sodium, and potassium in blood plasma samples. Optimum results were obtained with 20 mmol L−1 imidazole (pH 2.8) and 0.5 mmol L−1 oxalic acid containing 5% methanol, capillary temperature 25°C, applied voltage 30 kV, hydrodynamic injection time 3 s, and a poly(vinyl alcohol)-coated capillary (i.d. 50 μm, total length 64.5 cm and effective length 56 cm). Indirect detection was performed at 214 nm. Cadmium was used as internal standard. The migration times of magnesium, calcium, sodium, and potassium were 4.25, 3.79, 3.96, and 2.79 min, respectively. The method was applied to the determination of magnesium, calcium, sodium, and potassium in blood plasma samples. The results were compared with those from atomic absorption spectrophotometry and no statistically significant difference was found (P>0.05).
- 15 August 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 547 (1) , 83-88
Determination of sertaconazole in pharmaceutical preparations by capillary zone electrophoresis
- 15 August 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 547 (1) , 83-88
Determination of sertaconazole in pharmaceutical preparations by capillary zone electrophoresis
- 20 February 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (2) , 308-311
Determination of piribedil in pharmaceutical formulations by micellar electrokinetic capillary chromatography
- 20 February 2004
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 379 (2) , 308-311
Determination of piribedil in pharmaceutical formulations by micellar electrokinetic capillary chromatography
- 16 October 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (2) , 495-498
Electrochemical studies and square-wave voltammetric determination of fenofibrate in pharmaceutical formulations
- 16 October 2003
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 378 (2) , 495-498
Electrochemical studies and square-wave voltammetric determination of fenofibrate in pharmaceutical formulations
- 1 October 2002
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 30 (3) , 573-582
Determination of nifedipine in human plasma by square wave adsorptive stripping voltammetry
- 1 October 2002
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 30 (3) , 573-582
Determination of nifedipine in human plasma by square wave adsorptive stripping voltammetry