MWMartin R. Weinzierl

Martin R. Weinzierl

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Martin R. Weinzierl has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Franz-Josef Hans

    Department of Neurosurgery, University Hospital, RWTH Aachen University, Aachen, Germany

    1 shared publication
  • Marcus C. Korinth

    Department of Neurosurgery, University Hospital, RWTH Aachen University, Aachen, Germany

    1 shared publication
  • Markus F. Oertel

    Department of Neurosurgery, University Hospital, RWTH Aachen University, Aachen, Germany

    1 shared publication
  • Michael Stoffel

    Department of Neurosurgery, Technical University Munich, Klinikum rechts der Isar, Munich; and

    1 shared publication

Latest Publications

  • Experience with a gravitational valve in the management of symptomatic overdrainage in children with shunts

    by Martin R. Weinzierl, Franz-Josef Hans, Michael Stoffel, Markus F. Oertel, Marcus C. Korinth

    Symptomatic overdrainage in children with shunt-treated hydrocephalus represents one of the more difficult shunt-related diseases and may require repeated surgery. Gravity-assisted valve design has become a standard device to avoid overdrainage in many European pediatric hydrocephalus centers. However, the use of a gravitational valve for relieving symptoms associated with overdrainage has not yet been addressed. The goal of this study was to evaluate the effectiveness of a gravitational valve in the treatment of symptomatic overdrainage in children with shunts. Seventeen children with an adjustable shunt system and symptomatic overdrainage were treated by insertion of a gravitational valve. Clinical and radiological outcome were monitored for a minimum of 12 months after surgery. Implantation of a gravitational valve resulted in either resolution (n = 12) or improvement (n = 5) of the symptoms. In 1 patient, symptoms remained almost unchanged and the gravitational valve had to be upgraded, resulting in resolution of the symptoms. During follow-up, the pressure setting of the adjustable differential pressure valve had to be changed in 7 patients. The gravitational valve was effective in improving symptomatic overdrainage in the majority of patients in the present study. Because the ideal pressure setting for a given patient is hard to determine a priori, adjustable valve systems appear to be beneficial.