Martin R. Weinzierl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Martin R. Weinzierl has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Franz-Josef Hans
Department of Neurosurgery, University Hospital, RWTH Aachen University, Aachen, Germany
1 shared publicationMarcus C. Korinth
Department of Neurosurgery, University Hospital, RWTH Aachen University, Aachen, Germany
1 shared publicationMarkus F. Oertel
Department of Neurosurgery, University Hospital, RWTH Aachen University, Aachen, Germany
1 shared publicationMichael Stoffel
Department of Neurosurgery, Technical University Munich, Klinikum rechts der Isar, Munich; and
1 shared publication
Latest Publications
- 1 May 2012
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of neurosurgery. Pediatrics
- Vol. 9 (5) , 468-472
Experience with a gravitational valve in the management of symptomatic overdrainage in children with shunts
Symptomatic overdrainage in children with shunt-treated hydrocephalus represents one of the more difficult shunt-related diseases and may require repeated surgery. Gravity-assisted valve design has become a standard device to avoid overdrainage in many European pediatric hydrocephalus centers. However, the use of a gravitational valve for relieving symptoms associated with overdrainage has not yet been addressed. The goal of this study was to evaluate the effectiveness of a gravitational valve in the treatment of symptomatic overdrainage in children with shunts. Seventeen children with an adjustable shunt system and symptomatic overdrainage were treated by insertion of a gravitational valve. Clinical and radiological outcome were monitored for a minimum of 12 months after surgery. Implantation of a gravitational valve resulted in either resolution (n = 12) or improvement (n = 5) of the symptoms. In 1 patient, symptoms remained almost unchanged and the gravitational valve had to be upgraded, resulting in resolution of the symptoms. During follow-up, the pressure setting of the adjustable differential pressure valve had to be changed in 7 patients. The gravitational valve was effective in improving symptomatic overdrainage in the majority of patients in the present study. Because the ideal pressure setting for a given patient is hard to determine a priori, adjustable valve systems appear to be beneficial.
- 1 May 2012
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of neurosurgery. Pediatrics
- Vol. 9 (5) , 468-472
Experience with a gravitational valve in the management of symptomatic overdrainage in children with shunts
Symptomatic overdrainage in children with shunt-treated hydrocephalus represents one of the more difficult shunt-related diseases and may require repeated surgery. Gravity-assisted valve design has become a standard device to avoid overdrainage in many European pediatric hydrocephalus centers. However, the use of a gravitational valve for relieving symptoms associated with overdrainage has not yet been addressed. The goal of this study was to evaluate the effectiveness of a gravitational valve in the treatment of symptomatic overdrainage in children with shunts. Seventeen children with an adjustable shunt system and symptomatic overdrainage were treated by insertion of a gravitational valve. Clinical and radiological outcome were monitored for a minimum of 12 months after surgery. Implantation of a gravitational valve resulted in either resolution (n = 12) or improvement (n = 5) of the symptoms. In 1 patient, symptoms remained almost unchanged and the gravitational valve had to be upgraded, resulting in resolution of the symptoms. During follow-up, the pressure setting of the adjustable differential pressure valve had to be changed in 7 patients. The gravitational valve was effective in improving symptomatic overdrainage in the majority of patients in the present study. Because the ideal pressure setting for a given patient is hard to determine a priori, adjustable valve systems appear to be beneficial.