Gary W. Small
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gary W. Small has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Robert T. Kroutil
Los Alamos National Lab. (United States)
3 shared publicationsRobert T Kroutil
Los Alamos National Laboratory, P.O. Box 1663, MS E543, Los Alamos, NM 87545, USA
2 shared publicationsRoger J Combs
Los Alamos National Laboratory, P.O. Box 1663, MS E543, Los Alamos, NM 87545, USA
2 shared publicationsRoger J. Combs
Los Alamos National Laboratory, P.O. Box 1663, MS E543, Los Alamos, NM 87545, USA
2 shared publicationsToshiyasu Tarumi
Center for Intelligent Chemical Instrumentation, Department of Chemistry and Biochemistry, Clippinger Laboratories, OHIO University, Athens, OH 45701-2979, USA
2 shared publications- David Philip Miller
Department of Implementation Science, Wake Forest University School of Medicine, Winston-Salem, North Carolina
1 shared publication
Latest Publications
- 27 August 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7086, 708607
Implementation of an automated signal processing approach for the analysis of chemical spectral signatures collected from FT-IR mounted in an aircraft
The automated detection of chemical spectral signatures using a passive infrared Fourier Transform Infrared (FT-IR) Spectrometer mounted in an aircraft is a difficult challenge due to the small total infrared energy contribution of a particular chemical species compared to the background signature. The detection of spectral signatures is complicated by the fact that a large, widely varying infrared background is present that is coupled with the presence of a number of chemical interferents in the atmosphere. This paper describes a mathematical technique that has been successfully demonstrated to automatically detect specific chemical species in an automated processing environment. The data analysis methodology has been demonstrated to be effective using data of low spectral resolution at low aircraft altitudes. An overview of the implementation and basic concepts of the approach are presented.
- 27 August 2008
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7086, 708607
Implementation of an automated signal processing approach for the analysis of chemical spectral signatures collected from FT-IR mounted in an aircraft
The automated detection of chemical spectral signatures using a passive infrared Fourier Transform Infrared (FT-IR) Spectrometer mounted in an aircraft is a difficult challenge due to the small total infrared energy contribution of a particular chemical species compared to the background signature. The detection of spectral signatures is complicated by the fact that a large, widely varying infrared background is present that is coupled with the presence of a number of chemical interferents in the atmosphere. This paper describes a mathematical technique that has been successfully demonstrated to automatically detect specific chemical species in an automated processing environment. The data analysis methodology has been demonstrated to be effective using data of low spectral resolution at low aircraft altitudes. An overview of the implementation and basic concepts of the approach are presented.
- 14 January 2005
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 37 (1) , 39-52
Infinite impulse response filters for direct analysis of interferogram data from airborne passive Fourier transform infrared spectrometry
- 14 January 2005
- Published by Elsevier in Vibrational Spectroscopy
- Vol. 37 (1) , 39-52
Infinite impulse response filters for direct analysis of interferogram data from airborne passive Fourier transform infrared spectrometry
- 16 January 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 501 (2) , 235-247
High-pass filters for spectral background suppression in airborne passive Fourier transform infrared spectrometry
- 16 January 2004
- Published by Elsevier in Analytica Chimica Acta
- Vol. 501 (2) , 235-247
High-pass filters for spectral background suppression in airborne passive Fourier transform infrared spectrometry
- 1 August 2003
- Published by Elsevier in Analytica Chimica Acta
- Vol. 490 (1-2) , 325-340
Evaluation of selectivity and robustness of near-infrared glucose measurements based on short-scan Fourier transform infrared interferograms
- 1 August 2003
- Published by Elsevier in Analytica Chimica Acta
- Vol. 490 (1-2) , 325-340
Evaluation of selectivity and robustness of near-infrared glucose measurements based on short-scan Fourier transform infrared interferograms
- 1 September 2001
- Published by Defense Technical Information Center (DTIC)
Wolf Creek VI Conference on Cardiopulmonary Resuscitation
Digital filtering methods are evaluated for automated detection of ethanol using passive Fourier transform infrared (FT-IR) data collected during laboratory and open-air experiments. In applications where ethanol signals are overlapped by spectral interference signals (e.g., ammonia and acetone), the use of multiple digital filters is found to improve the sensitivity of the vapor analyte detection. The detection strategy applies bandpass digital filters to short interferogram segments that are acquired from the passive FT-IR spectrometer configuration. To implement the automated detection of the ethanol target analyte, the filtered interferogram segments are input into a piece-wise linear discriminant analysis. Through the use of a set of training data, discriminants are computed that are subsequently used for automated detection of ethanol vapor. A two-filter strategy with separate ethanol and ammonia filters is compared to a single ethanol filter approach. Bandpass parameters of the digital filters and the interferogram segment location are optimized with laboratory data. The laboratory data are generated for ethanol, ammonia, and acetone vapor mixtures in a gas cell, whose contents are viewed against various infrared background radiances. The optimized parameters, from the laboratory data, are subsequently tested with open-air remote sensing data. The open-air data consists of elevated temperature ethanol and ammonia plumes generated from a portable emission stack. The two-filter strategy outperforms the single-filter approach in laboratory and open-air scenarios, where the ammonia spectral interference dominates the ethanol spectral signature.
- 1 September 2001
- Published by Defense Technical Information Center (DTIC)
Wolf Creek VI Conference on Cardiopulmonary Resuscitation
Digital filtering methods are evaluated for automated detection of ethanol using passive Fourier transform infrared (FT-IR) data collected during laboratory and open-air experiments. In applications where ethanol signals are overlapped by spectral interference signals (e.g., ammonia and acetone), the use of multiple digital filters is found to improve the sensitivity of the vapor analyte detection. The detection strategy applies bandpass digital filters to short interferogram segments that are acquired from the passive FT-IR spectrometer configuration. To implement the automated detection of the ethanol target analyte, the filtered interferogram segments are input into a piece-wise linear discriminant analysis. Through the use of a set of training data, discriminants are computed that are subsequently used for automated detection of ethanol vapor. A two-filter strategy with separate ethanol and ammonia filters is compared to a single ethanol filter approach. Bandpass parameters of the digital filters and the interferogram segment location are optimized with laboratory data. The laboratory data are generated for ethanol, ammonia, and acetone vapor mixtures in a gas cell, whose contents are viewed against various infrared background radiances. The optimized parameters, from the laboratory data, are subsequently tested with open-air remote sensing data. The open-air data consists of elevated temperature ethanol and ammonia plumes generated from a portable emission stack. The two-filter strategy outperforms the single-filter approach in laboratory and open-air scenarios, where the ammonia spectral interference dominates the ethanol spectral signature.
- 31 January 1994
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2089, 24-32
Remote infrared vapor detection of volatile organic compounds
In many open-air monitoring applications of Fourier transform spectrometry (FTS), the lack of a valid background reference spectrum limits the ability to perform quantitative measurements. Suppression of the broad band detector envelope overcomes this limitation. Interferogram processing provides a means of suppressing the broad band background, while maintaining the target spectral signatures of interest. A combination of interferogram segment selection, digital filtering, and pattern discrimination techniques achieve the background suppression of the variable broad band detector envelope. The spectral band position, width, and strength of the target vapor determine the parameters that are used for background suppression. Interferogram segment selection depends primarily on spectral band width. Digital filter design requires inputs of both spectral band position and width. The pattern discrimination techniques compensate for variation in the spectral shape with band strength.
- 31 January 1994
- Published by SPIE-Intl Soc Optical Eng
- Vol. 2089, 24-32
Remote infrared vapor detection of volatile organic compounds
In many open-air monitoring applications of Fourier transform spectrometry (FTS), the lack of a valid background reference spectrum limits the ability to perform quantitative measurements. Suppression of the broad band detector envelope overcomes this limitation. Interferogram processing provides a means of suppressing the broad band background, while maintaining the target spectral signatures of interest. A combination of interferogram segment selection, digital filtering, and pattern discrimination techniques achieve the background suppression of the variable broad band detector envelope. The spectral band position, width, and strength of the target vapor determine the parameters that are used for background suppression. Interferogram segment selection depends primarily on spectral band width. Digital filter design requires inputs of both spectral band position and width. The pattern discrimination techniques compensate for variation in the spectral shape with band strength.