Paulo Cícero Do Nascimento
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paulo Cícero Do Nascimento has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Denise Bohrer
12 shared publicationsLeandro M. de Carvalho
8 shared publications- Denise Bohrer
Departamento de Química, Universidade Federal de Santa Maria, Santa Maria, RS, Brazil
4 shared publications - Leandro Machado de Carvalho
Graduate Program in Chemistry, Department of Chemistry, Federal University of Santa Maria, PO Box 5051, 97105-970, Santa Maria, RS, Brazil
3 shared publications - Cristiane Luisa Jost
Department of Chemistry, ampere – Laboratório de Plataformas Eletroquímicas, Federal University of Santa Catarina, Florianópolis, Brazil
2 shared publications Cristiane Spengler
Universidade Federal de Santa Maria, Santa Maria, Brasil
2 shared publications
Latest Publications
- Open Access
- 1 January 2010
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 33 (8) , 1765-1772
Voltametria de micropartículas imobilizadas: fundamentos e aplicações analíticas
The theoretical aspects of Voltammetry of Immobilized Microparticles (VIM) were discussed. The immobilization of microparticles on electrode surface, the electrode cleaning processes and the electrode materials were analyzed. The three-phase electrode model and the possible reactions between the immobilized particle and the electrolytic solution were discussed. In addition, this work discusses some selected applications of VIM published in the last years
- 1 January 2010
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 33 (8) , 1765-1772
Open AccessVoltametria de micropartículas imobilizadas: fundamentos e aplicações analíticas
The theoretical aspects of Voltammetry of Immobilized Microparticles (VIM) were discussed. The immobilization of microparticles on electrode surface, the electrode cleaning processes and the electrode materials were analyzed. The three-phase electrode model and the possible reactions between the immobilized particle and the electrolytic solution were discussed. In addition, this work discusses some selected applications of VIM published in the last years
- 1 August 2009
- Published by Elsevier in Analytica Chimica Acta
- Vol. 648 (2) , 162-166
Voltammetric determination of Se(IV) and Se(VI) in saline samples—Studies with seawater, hydrothermal and hemodialysis fluids
- 1 August 2009
- Published by Elsevier in Analytica Chimica Acta
- Vol. 648 (2) , 162-166
Voltammetric determination of Se(IV) and Se(VI) in saline samples—Studies with seawater, hydrothermal and hemodialysis fluids
- Open Access
- 1 January 2009
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 32 (8) , 2203-2208
Determinação simultânea de cátions empregando eletroforese capilar com detecção condutométrica sem contato em equipamento construído em laboratório
This work describes the development of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the separation of the metallic species Zn2+, Cr3+, Pb2+, Cd2+, Co2+, Cu2+, Ni2+ e Tl+. A background electrolyte composed of MES/Histidine 0,02 mol L-1 (pH 5.0) was optimized for the separation of the metallic species by using organic solvents and complexing agents as additives. The system allowed the determination of the metallic species using MES/Histidine 0,02 mol L-1 and methanol 5% (pH 5.0) as a background electrolyte, 15 kV separation voltage and hydrodynamic injection by gravity
- 1 January 2009
- Published by FapUNIFESP (SciELO) in Química Nova
- Vol. 32 (8) , 2203-2208
Open AccessDeterminação simultânea de cátions empregando eletroforese capilar com detecção condutométrica sem contato em equipamento construído em laboratório
This work describes the development of a home-made capillary electrophoresis (CE) system based on the capacitively coupled contactless conductivity detection (C4D) for the separation of the metallic species Zn2+, Cr3+, Pb2+, Cd2+, Co2+, Cu2+, Ni2+ e Tl+. A background electrolyte composed of MES/Histidine 0,02 mol L-1 (pH 5.0) was optimized for the separation of the metallic species by using organic solvents and complexing agents as additives. The system allowed the determination of the metallic species using MES/Histidine 0,02 mol L-1 and methanol 5% (pH 5.0) as a background electrolyte, 15 kV separation voltage and hydrodynamic injection by gravity
- 7 May 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (10) , 1078-1084
Al(III) and Fe(III) Balance in Hemodialysis Treatment Assessed via Fluid Analysis by Adsorptive Stripping Voltammetry and UV Sample Digestion
Simultaneous determination of Al(III) and Fe(III) in posthemodialysis fluids was investigated by the Adsorptive stripping voltammetry of solochrome violet metal complexes. The adsorption of the complexes on the mercury electrode (HMDE) was investigated by out of phase altenating current voltammetry in presence of the main matrix interfering species. Sample digestion by UV irradiation was investigated to overcome the matrix interference. The proposed method was valid for real posthemodialysis samples containing or not Desferrioxamine B. Detection limits of 1.4 and 1.8 μg L−1 were calculated for Al(III) and Fe(III), respectively. Recoveries ranging from 88.1 to 106.3% were obtained from spiking experiments.
- 7 May 2008
- Published by Wiley in Electroanalysis
- Vol. 20 (10) , 1078-1084
Al(III) and Fe(III) Balance in Hemodialysis Treatment Assessed via Fluid Analysis by Adsorptive Stripping Voltammetry and UV Sample Digestion
Simultaneous determination of Al(III) and Fe(III) in posthemodialysis fluids was investigated by the Adsorptive stripping voltammetry of solochrome violet metal complexes. The adsorption of the complexes on the mercury electrode (HMDE) was investigated by out of phase altenating current voltammetry in presence of the main matrix interfering species. Sample digestion by UV irradiation was investigated to overcome the matrix interference. The proposed method was valid for real posthemodialysis samples containing or not Desferrioxamine B. Detection limits of 1.4 and 1.8 μg L−1 were calculated for Al(III) and Fe(III), respectively. Recoveries ranging from 88.1 to 106.3% were obtained from spiking experiments.
- 1 April 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (4) , 777-790
Simultaneous Determination of Cadmium, Copper, Lead and Zinc in Amino Acid Parenteral Nutrition Solutions by Anodic Stripping Voltammetry and Sample Digestion by UV Irradiation
Irradiation with ultraviolet (UV) energy was investigated to assay cadmium, copper, lead, and zinc by anodic stripping voltammetry (ASV) in amino acid parenteral nutrition (PN) solutions. Sample digestion by UV irradiation showed the best performances to liberate the metals from the samples (metal recoveries between 90% and 102%) in comparison with classical oxidative wet digestion methods. The best UV digestion condition was obtained with 1:10 diluted PN samples irradiated during 10 h at 90±3°C with the addition of one aliquot of 50 µL concentrated H2SO4 and repeated additions of 50 µL 30% (v/v) H2O2 at each 60 min irradiation interval. By using the UV digestion procedure cadmium, copper, lead, and zinc were simultaneously assayed in commercial amino acid PN solutions by ASV. The metal concentrations ranged between 1.3 to 4.4 for cadmium, 2.9 to 40.8 for copper, 4.4 to 16.8 for lead, and 1.4 to 208.5 for zinc. The ASV method correlated well with atomic absorption spectrometry measurements to assay the investigated analytes in amino acid PN samples after the UV digestion.
- 1 April 2006
- Published by Taylor & Francis in Analytical Letters
- Vol. 39 (4) , 777-790
Simultaneous Determination of Cadmium, Copper, Lead and Zinc in Amino Acid Parenteral Nutrition Solutions by Anodic Stripping Voltammetry and Sample Digestion by UV Irradiation
Irradiation with ultraviolet (UV) energy was investigated to assay cadmium, copper, lead, and zinc by anodic stripping voltammetry (ASV) in amino acid parenteral nutrition (PN) solutions. Sample digestion by UV irradiation showed the best performances to liberate the metals from the samples (metal recoveries between 90% and 102%) in comparison with classical oxidative wet digestion methods. The best UV digestion condition was obtained with 1:10 diluted PN samples irradiated during 10 h at 90±3°C with the addition of one aliquot of 50 µL concentrated H2SO4 and repeated additions of 50 µL 30% (v/v) H2O2 at each 60 min irradiation interval. By using the UV digestion procedure cadmium, copper, lead, and zinc were simultaneously assayed in commercial amino acid PN solutions by ASV. The metal concentrations ranged between 1.3 to 4.4 for cadmium, 2.9 to 40.8 for copper, 4.4 to 16.8 for lead, and 1.4 to 208.5 for zinc. The ASV method correlated well with atomic absorption spectrometry measurements to assay the investigated analytes in amino acid PN samples after the UV digestion.
- Open Access
- 1 August 2003
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 14 (4) , 577-583
Determination of triazines in hemodialysis saline solutions by adsorptive stripping voltammetry after extraction in acetonitrile
A method for the voltammetric determination of 2-methylthio-4,6-dialkylamino-1,3,5-triazine (triazines) herbicides in hemodialysis (HD) saline solutions was developed. The herbicides were detected in the saline solutions at the hanging mercury drop electrode (HMDE) with high sensitivities only after extraction of the analytes in acetonitrile (ACN). The salting out effect originated by the saline environment existing in the solutions enabled the extractions. The volume ratio between the saline and ACN phases was investigated in order to find the best sensitivity to detect the triazines. The speciation amongst them (ametryn, desmetryn, prometryn and terbutryn) was not possible. Recoveries between 88 and 107% were calculated in spiked samples, and detection limits of 0.03 mumol L-1 were calculated for the triazines in the saline samples using this methodology.
- 1 August 2003
- Published by Sociedade Brasileira de Quimica (SBQ) in Journal of the Brazilian Chemical Society
- Vol. 14 (4) , 577-583
Open AccessDetermination of triazines in hemodialysis saline solutions by adsorptive stripping voltammetry after extraction in acetonitrile
A method for the voltammetric determination of 2-methylthio-4,6-dialkylamino-1,3,5-triazine (triazines) herbicides in hemodialysis (HD) saline solutions was developed. The herbicides were detected in the saline solutions at the hanging mercury drop electrode (HMDE) with high sensitivities only after extraction of the analytes in acetonitrile (ACN). The salting out effect originated by the saline environment existing in the solutions enabled the extractions. The volume ratio between the saline and ACN phases was investigated in order to find the best sensitivity to detect the triazines. The speciation amongst them (ametryn, desmetryn, prometryn and terbutryn) was not possible. Recoveries between 88 and 107% were calculated in spiked samples, and detection limits of 0.03 mumol L-1 were calculated for the triazines in the saline samples using this methodology.
- 23 June 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (9-10) , 829-834
Polyethylene powder microcolumn for protein separation prior to HPLC plasma analysis. Application to the determination of copper and zinc
Three different types of polyethylene powder (PE) were investigated with regard to their ability to adsorb proteins, with the goal of accomplishing plasma deproteinization for further HPLC analysis. Best results were obtained with ultrahigh molecular mass polyethylene The proteins retained by the PE powder were washed out of the column with methanol followed by water. A chromatographic system with the PE column as pre‐column was set up for the determination of copper and zinc in plasma. The plasma sample was injected into the chromatograph, and, on passage through the pre‐column, the proteins were adsorbed onto the PE. While a protein‐free eluate was being sent to the analytical column, by switching the pump channels the pre‐column was being flushed with methanol and water to elute the adsorbed proteins. After washing, the pre‐column was conditioned with the eluent to receive the next sample. Copper and zinc determination was performed by HPLC with photometric detection after post‐column derivatization with 4‐(2‐pyridylazo)resorcinol (PAR). The results, compared with those from flame atomic absorption spectrometry, showed that zinc can be determined by direct injection of the sample, but copper only after dilution. As the copper recovery from undiluted samples was about 65%, it was probably retained together with the proteins. However, on previous dilution of the sample with the eluent (acidic solution of lactic acid) the copper recovery reached 100%. The proposed method is suitable for the HPLC determination of copper and zinc in plasma samples without further sample treatment, in about 30 min.
- 23 June 2003
- Published by Wiley in Journal of Separation Science
- Vol. 26 (9-10) , 829-834
Polyethylene powder microcolumn for protein separation prior to HPLC plasma analysis. Application to the determination of copper and zinc
Three different types of polyethylene powder (PE) were investigated with regard to their ability to adsorb proteins, with the goal of accomplishing plasma deproteinization for further HPLC analysis. Best results were obtained with ultrahigh molecular mass polyethylene The proteins retained by the PE powder were washed out of the column with methanol followed by water. A chromatographic system with the PE column as pre‐column was set up for the determination of copper and zinc in plasma. The plasma sample was injected into the chromatograph, and, on passage through the pre‐column, the proteins were adsorbed onto the PE. While a protein‐free eluate was being sent to the analytical column, by switching the pump channels the pre‐column was being flushed with methanol and water to elute the adsorbed proteins. After washing, the pre‐column was conditioned with the eluent to receive the next sample. Copper and zinc determination was performed by HPLC with photometric detection after post‐column derivatization with 4‐(2‐pyridylazo)resorcinol (PAR). The results, compared with those from flame atomic absorption spectrometry, showed that zinc can be determined by direct injection of the sample, but copper only after dilution. As the copper recovery from undiluted samples was about 65%, it was probably retained together with the proteins. However, on previous dilution of the sample with the eluent (acidic solution of lactic acid) the copper recovery reached 100%. The proposed method is suitable for the HPLC determination of copper and zinc in plasma samples without further sample treatment, in about 30 min.