PKProespichaya Kanatharana

Proespichaya Kanatharana

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Proespichaya Kanatharana has a total of 52 co-authors. Here are the top co-authors by number of shared publications:

  • Panote Thavarungkul

    Trace Analysis and Biosensor Research Center, Prince of Songkla University, Hat Yai, Songkhla, 90112, Thailand

    16 shared publications
  • Chongdee Thammakhet

    A Trace Analysis and Biosensor Research Center, Prince of Songkla University , Hat Yai, Songkhla , Thailand

    9 shared publications
  • Panote Thavarungkul

    Center of Excellence for Trace Analysis and Biosensor, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Division of Physical Science, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Prince of Songkla University, Hat Yai, Songkhla, 90110, Thailand

    8 shared publications
  • Apon Numnuam

    Prince of Songkla University

    5 shared publications
  • Warakorn Limbut

    Trace Analysis and Biosensor Research Center Prince of Songkla University Hat Yai, Songkhla 90112 Thailand

    5 shared publications
  • Supaporn Dawan

    Trace Analysis and Biosensor Research Center Prince of Songkla University Hat Yai, Songkhla 90112 Thailand

    3 shared publications

Latest Publications

  • Open Access

    An Unlabeled Electrochemical Immunosensor Uses Poly(thionine) and Graphene Quantum Dot-Modified Activated Marigold Flower Carbon for Early Prostate Cancer Detection

    by Suparat Cotchim, Supatinee Kongkaew, Panote Thavarungkul, Proespichaya Kanatharana, Warakorn Limbut

    The activated carbon from marigold flowers (MG) was used to make an unlabeled electrochemical immunosensor to determine prostate cancer. MG was synthesized by hydrothermal carbonization and pyrolysis. MG had a large surface area, was highly conductive, and biocompatible. MG modified with graphene quantum dots produced excellent electron transfer for grafting poly(thionine) (PTH). The amine group of PTH bonded with anti-prostate-specific antigen (Anti-PSA) via glutaraldehyde, forming a layer that improved electron transfer. The binding affinity of the immunosensor, presented as the dissociation constant (Kd), was calculated using the Langmuir isotherm model. The results showed that a lower Kd value indicated greater antibody affinity. The immunosensor exhibited two different linear ranges under optimized conditions: 0.0125 to 1.0 ng mL−1 and 1.0 to 80.0 ng mL−1. The sensor could detect concentrations as low as 0.005 ng mL−1, and had a quantification limit of 0.017 ng mL−1. This immunosensor accurately quantified PSA levels of human serum, and the results were validated using enzyme-linked fluorescence assay (ELFA).


  • Open Access

    A Cotton Bud Coated with Chitosan/N-Carbon Dot Composite as SPE Sorbent for Extraction of Steroid Hormones from Fish Farm Water

    by Deki, Panote Thavarungkul, Proespichaya Kanatharana, Chongdee Thammakhet Buranachai

  • Open Access

    A Fabrication of Multichannel Graphite Electrode Using Low-Cost Stencil-Printing Technique

    by Supatinee Kongkaew, Suowarot Tubtimtong, Panote Thavarungkul, Proespichaya Kanatharana, Kah Haw Chang, Ahmad Fahmi Lim Abdullah, Warakorn Limbut

    Multichannel graphite electrodes (MGrEs) have been designed and fabricated in this study. A template was cut from an adhesive plastic sheet using a desktop cutting device. The template was placed on a polypropylene substrate, and carbon graphite ink was applied with a squeegee to the template. The size of the auxiliary electrode (AE) as well as the location of the reference electrode (RE) of MGrEs design were investigated. Scanning electron microscopy was used to determine the thickness of the ink on the four working electrodes (WEs), which was 21.9 ± 1.8 µm. Cyclic voltammetry with a redox probe solution was used to assess the precision of the four WEs. The intra-electrode repeatability and inter-electrode reproducibility of the MGrEs production were satisfied by low RSD (<6%). Therefore, the MGrEs is reliable and capable of detecting four replicates of the target analyte in a single analysis. The electrochemical performance of four WEs was investigated and compared to one WE. The sensitivity of the MGrEs was comparable to the sensitivity of a single WE. The MGrEs’ potential applications were investigated by analyzing the nitrite in milk and tap water samples (recoveries values of 97.6 ± 0.4 to 110 ± 2%).


  • A stir foam composed of graphene oxide, poly(ethylene glycol) and natural latex for the extraction of preservatives and antioxidant

    by Charinrat Siritham, Chongdee Thammakhet-Buranachai, Panote Thavarungkul, Proespichaya Kanatharana

    A stir foam composed of graphene oxide, poly(ethylene glycol) and natural latex (GO-PEG-NL) was prepared for use in micro-solid phase extraction sorbent of preservative agents and antioxidants from cosmetic products. The extracted analytes were quantified by GC-MS. Under the optimized conditions, the calibration plots are linear in the concentration ranges between 5.0 μg·L−1 to 1.0 mg·L−1 for benzoic acid, of 10.0 μg·L−1 to 1.0 mg·L−1 for 2-methyl-3-isothiazolinone (MI), and between 1.0 μg·L−1 and 1.0 mg·L−1 for both 3-tert-butyl-4-hydroxyanisole (BHA) and 2,6-di-tert-butyl-p-hydroxytoluene (BHT). The LODs are 1.0 μg·L−1 for benzoic acid, 5.0 μg·L−1 for MI and 0.5 μg·L−1 for both BHA and BHT. The stir-foam can be easily prepared, is inexpensive and well reproducible (RSDs n = 6). It can be re-used for up to 12 times after which extraction efficiency has dropped to 90%. The method was successfully applied to the determination of preservatives and antioxidants in cosmetic samples. Recoveries from spiked samples ranged between 94.5 ± 2.1% and 99.8 ± 1.8%.


  • A preconcentrator-separator two-in-one online system for polycyclic aromatic hydrocarbons analysis

    by Charinrat Siritham, Chongdee Thammakhet-Buranachai, Panote Thavarungkul, Proespichaya Kanatharana


  • A Simple and Highly Stable Porous Gold‐based Electrochemical Sensor for Bisphenol A Detection

    by Rodtichoti Wannapob, Panote Thavarungkul, Supaporn Dawan, Apon Numnuam, Warakorn Limbut, Proespichaya Kanatharana

    A porous gold electrode with a uniform pore size was prepared by a simple single potential step method. It provided around 19 times more surface area than a bare gold electrode. The porous gold electrode, without any modification, exhibited good electrocatalytic activity towards the oxidation of bisphenol A (BPA). The effect of the pH and scan rate, on the porous gold electrode was studied and discussed. Under optimum conditions of the flow system, the calibration plot of BPA was linear over a wide range of concentration, from 2.0 nM to 800 nM (R2=0.999), and the detection limit was 2.0 nM (s/n=3). It was of interest that, the porous gold electrode showed an exceptional result in minimizing the fouling from the oxidation product of BPA and led to a very high operational stability of the electrode for the detection of BPA (560 consecutive times). The porous gold electrode showed good fabrication reproducibility and can be used to detect bisphenol A that leached from baby bottles and drinking water bottles. The obtained results were in good agreement with the GC‐MS method (P>0.05).


  • Distributions of SO2and NO2in the lower atmosphere of an industrial area in Bhutan

    by Jas Raj Subba, Chongdee Thammakhet, Panote Thavarungkul, Proespichaya Kanatharana

    Two important air pollutants, sulfur dioxide (SO2) and nitrogen dioxide (NO2), were sampled and monitored in the spring season in the biggest industrial area of Bhutan. Field measurements of SO2 and NO2 were performed using standard colorimetric methods, and air samples were collected using an active sampling technique. Sampling sites were selected to cover all the potential catchment areas like settlements, staff quarters, shops and schools. The main objective of this sampling work was to see the distribution of these two pollutants from the source of emission (small scale industries) and to obtain and establish a baseline data. The active sampler was first tested and validated in a laboratory using liquid and gas standards of SO2 and NO2. Good linearity from 0.050 to 1.0 µg mL−1 for SO2 and from 0.010 to 1.0 µg mL−1 for NO2 were obtained (R2 > 0.99) with limits of detection of 30 and 50 ng mL−1 for SO2 and NO2, respectively. Daylong sampling was done at selected sites with a range of distances away from the sources of emission. The ambient concentration of SO2 and NO2 were in the range of 0.45–4.46 and 0.56–5.68 µg m−3, respectively.


  • Sampling of BTX in Hat Yai city using cost effective laboratory-built PCB passive sampler

    by Jas Raj Subba, Chongdee Thammakhet, Panote Thavarungkul, Proespichaya Kanatharana

    A laboratory-built printed circuit board (PCB) passive sampler used for the monitoring of xylene and styrene in copy print shops was re-validated for detecting benzene, toluene and xylene (BTX) and applied for the sampling of ambient air from Hat Yai city, Songkhla, Thailand, in the month of November 2014. For monitoring, the PCB passive samplers were exposed to target analytes in 16 locations covering high to low exposure areas. After sampling, the samplers were thermally desorbed and the analytes were trapped by multi-walled carbon nanotubes packed into a micro-preconcentrator coupled to a gas chromatograph (GC) equipped with a flame ionization detector. At the optimum GC operating conditions, the linear dynamic ranges for BTX were 0.06–5.6 µg for benzene, 0.07–2.2 µg for toluene and 0.23–2.5 µg for xylene with R2 > 0.99 with the limits of detection being 6.6, 6.8 and 19 ng for benzene, toluene and xylene, respectively. The concentrations of BTX in the 16 sampling sites were in the range of N.D.–1.3 ± 1.6, 4.50 ± 0.76–49.6 ± 3.7 and 1.00 ± 0.21–39.6 ± 3.1 µg m−3, respectively. When compared to past studies, there had been an increase in the benzene concentration.


  • Multiwalled carbon nanotubes–poly(vinyl alcohol) composite cryogel used in microcolumn liquid chromatography to separate various herbicides

    by C. Siritham, C. Thammakhet, P. Thavarungkul, P. Kanatharana

    A simple liquid chromatographic system that consisted of a Teflon tube filled with a MWCNTs–PVA composite cryogel microcolumn connected to an on-column UV-visible detector was developed. The system was applied to the simultaneous determination of atrazine, diuron and 2,4-(dichlorophenoxy)acetic acid (2,4-D) in water samples. Using optimum conditions, the system provided a linear range from 1.0 μg L−1 to 1.50 mg L−1 for atrazine and diuron and 2.0 μg L−1 to 2.00 mg L−1 for 2,4-D. The limits of detection were 0.75 μg L−1 for atrazine and diuron and 1.00 μg L−1 for 2,4-D. A good microcolumn-to-microcolumn reproducibility with a relative standard deviation (RSD) of 1.4–2.3% and a good precision with % RSD of 1.09, 0.95 and 1.56 for peak areas of atrazine, diuron and 2,4-D were obtained. The developed method provided good chromatographic performance, with the values of plate number (N ≥ 2000), the peak asymmetry factor (As ≤ 1.0), resolution (Rs ≥ 5.6) and capacity factor (3.3 ≤ k′ ≤ 14) all within the acceptable ranges. This simple liquid chromatographic system, with a 10 cm long microcolumn, without a high pressure pump, was successfully applied to the simultaneous determination of atrazine, diuron and 2,4-D in water samples. This developed method could be easily applied to the separation of other compounds.