Xiaoyun Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiaoyun Zhang has a total of 113 co-authors. Here are the top co-authors by number of shared publications:
- Hong Lin Zhai
College of Chemistry and Chemical Engineering, Lanzhou University, Lanzhou 730000, People's Republic of China
8 shared publications - Feng Luan
School of Chemistry and Chemical Engineering, Yantai University, Yantai 264005, China
5 shared publications Shuying Ma
Department of Chemistry, Lanzhou University, Lanzhou 730000, Gansu, People's Republic of China
4 shared publicationsWenjuan Lv
A College of Chemistry and Chemical Engineering , Lanzhou University , Lanzhou , PR China
4 shared publicationsBotao Fan
Université Paris 7-Denis Diderot, ITODYS 1, Rue Guy de la Brosse, 75005 Paris, France
3 shared publicationsFangfang Deng
Department of Chemistry, Lanzhou University, Lanzhou 730000, Gansu, People's Republic of China
3 shared publications
Latest Publications
- 16 September 2026
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 27 (10) , 6513-6526
Topology-Dependent Application of Fluorinated bPEI and PAMAM G4 in Gene Delivery
Existing research of single polymer systems has primarily focused on the modification and optimization, with limited systematic comparisons of the performance evolution and gene transfection differences between branched polyethyleneimine (bPEI) and dendritic polyamide-amine (PAMAM) after fluorination modification. In this study, a series of fluorinated polymers were prepared by fluorinating 25 kDa bPEI and PAMAM G4 using heptafluorobutyric anhydride. The pEGFP plasmid was employed as a model gene. The gene transfection efficiencies of both types of materials before and after fluorination were systematically compared and evaluated using fluorescence analysis, flow cytometry, and in vivo imaging techniques. The results demonstrated that fluorination significantly enhanced transfection efficiency under serum-containing conditions. PAMAM G4-F773 in particular exhibited superior performance compared to fluorinated bPEI and the commercial Lipofectamine 2000 transfection reagent. This study represents the first systematic comparison of transfection performance between these two types of fluorinated polymers, providing crucial insights for rational design of gene delivery vectors.
- 16 September 2026
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 27 (10) , 6513-6526
Topology-Dependent Application of Fluorinated bPEI and PAMAM G4 in Gene Delivery
Existing research of single polymer systems has primarily focused on the modification and optimization, with limited systematic comparisons of the performance evolution and gene transfection differences between branched polyethyleneimine (bPEI) and dendritic polyamide-amine (PAMAM) after fluorination modification. In this study, a series of fluorinated polymers were prepared by fluorinating 25 kDa bPEI and PAMAM G4 using heptafluorobutyric anhydride. The pEGFP plasmid was employed as a model gene. The gene transfection efficiencies of both types of materials before and after fluorination were systematically compared and evaluated using fluorescence analysis, flow cytometry, and in vivo imaging techniques. The results demonstrated that fluorination significantly enhanced transfection efficiency under serum-containing conditions. PAMAM G4-F773 in particular exhibited superior performance compared to fluorinated bPEI and the commercial Lipofectamine 2000 transfection reagent. This study represents the first systematic comparison of transfection performance between these two types of fluorinated polymers, providing crucial insights for rational design of gene delivery vectors.
- 7 December 2023
- Published by Springer Nature in Drug Delivery and Translational Research
- Vol. 14 (6) , 1551-1566
Design, optimization, and evaluation for a long-time-released transdermal microneedle delivery system containing estradiol
Transdermal drug delivery systems (TDDS) have drawbacks such as poor absorption, low blood concentration, and delayed effects. Dissolving microneedle has sharp tips and short length, which overcome patients’ pain and improve transdermal efficiency but has low mechanical strength and drug loading capacity. This study thereby proposes a microemulsion-encapsulated and long-time-released transdermal microneedle (MN) delivery system with estradiol (Es) as the model drug. The microemulsion (ME) was optimized by utilizing the pseudo-ternary phase diagram and D-optimal mixture design. The estradiol microemulsion-encapsulated microneedle (Es-ME-MN) was optimized by Box–Behnken design and prepared by freeze–thaw method. The Es-ME-MN obtained was characterized and evaluated through a large variety of studies. Es-ME-MN had sufficient mechanical strength to pierce skin and was safe enough, the length of which was 600 μm, and the Es content was 177.12 ± 0.72 μg/patch without drug-excipient chemical interaction. In vitro permeation study showed that Es-ME-MN has a higher transdermal efficiency and lower retention capacity than commercial estradiol patch and conventional MN. Es plasma concentration began to increase at 3 h and remained at 12.98–23.52 ng/mL until 72 h by pharmacokinetic experiments in the Es-ME-MN group. Es-ME-MN rapidly achieves effective blood concentrations through needle puncture and microemulsion delivery and maintains blood concentrations through the baseplate long-time release. Microemulsion-encapsulated, organic solvent-free, and long-time-released transdermal microneedle will make progress and provide a new idea for transdermal delivery of lipophilic drugs. Graphical Abstract
- 7 December 2023
- Published by Springer Nature in Drug Delivery and Translational Research
- Vol. 14 (6) , 1551-1566
Design, optimization, and evaluation for a long-time-released transdermal microneedle delivery system containing estradiol
Transdermal drug delivery systems (TDDS) have drawbacks such as poor absorption, low blood concentration, and delayed effects. Dissolving microneedle has sharp tips and short length, which overcome patients’ pain and improve transdermal efficiency but has low mechanical strength and drug loading capacity. This study thereby proposes a microemulsion-encapsulated and long-time-released transdermal microneedle (MN) delivery system with estradiol (Es) as the model drug. The microemulsion (ME) was optimized by utilizing the pseudo-ternary phase diagram and D-optimal mixture design. The estradiol microemulsion-encapsulated microneedle (Es-ME-MN) was optimized by Box–Behnken design and prepared by freeze–thaw method. The Es-ME-MN obtained was characterized and evaluated through a large variety of studies. Es-ME-MN had sufficient mechanical strength to pierce skin and was safe enough, the length of which was 600 μm, and the Es content was 177.12 ± 0.72 μg/patch without drug-excipient chemical interaction. In vitro permeation study showed that Es-ME-MN has a higher transdermal efficiency and lower retention capacity than commercial estradiol patch and conventional MN. Es plasma concentration began to increase at 3 h and remained at 12.98–23.52 ng/mL until 72 h by pharmacokinetic experiments in the Es-ME-MN group. Es-ME-MN rapidly achieves effective blood concentrations through needle puncture and microemulsion delivery and maintains blood concentrations through the baseplate long-time release. Microemulsion-encapsulated, organic solvent-free, and long-time-released transdermal microneedle will make progress and provide a new idea for transdermal delivery of lipophilic drugs. Graphical Abstract
- 23 June 2023
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 24 (6) , 1-10
Transdermal Delivery of Estradiol Simultaneously Possessing Rapid Release and Sustained Release Effect
Dissolving microneedle (DMN) has been researched as a drug delivery technology that improves drug molecule transportation through the skin with little disc
- 23 June 2023
- Published by Springer Nature in AAPS PharmSciTech
- Vol. 24 (6) , 1-10
Transdermal Delivery of Estradiol Simultaneously Possessing Rapid Release and Sustained Release Effect
Dissolving microneedle (DMN) has been researched as a drug delivery technology that improves drug molecule transportation through the skin with little disc
- 5 July 2022
- Published by Springer Nature in European Journal of Drug Metabolism and Pharmacokinetics
- Vol. 47 (5) , 677-686
A pH/Time/Pectinase-Dependent Oral Colon-Targeted System Containing Isoliquiritigenin: Pharmacokinetics and Colon Targeting Evaluation in Mice
Background and Objectives Oral colon-targeted gel beads containing isoliquiritigenin (ISL) were successfully designed in our study. In order to further explore the targeting of the colon by the gel beads, a systematic study of their in vivo pharmacokinetics and colon targeting was performed in mice. Methods Eighteen male mice were included in this study. The mice were separated into six groups at random. We collected blood, stomach, duodenum, jejunum, ileum, and colon tissues at 2, 4, 6, 8, 12, and 24 h after oral administration of gel beads containing isoliquiritigenin at a dose of 20 mg/kg. Gel beads in tissues were recorded and taken out to observe their swelling and erosion. The total ISL concentrations in different tissues and gel beads were analyzed by high-performance liquid chromatography. Results All gel beads reached the upper part of the stomach at 2 h with no obvious swelling. Most of the gel beads were still in the lower part of stomach, while a small amount had reached the small intestine at 4 h. A few gel beads reached the colon and swelled at 6 h. Furthermore, the gel beads in the colon were swollen and erosive at 8 h. Meanwhile, the plasma ISL concentration could be detected, which indicated that the ISL in the gel beads was absorbed. At 12 h, the gel beads were almost dissolved and the plasma concentration was 8.33 times that at 8 h. At 24 h, the gel beads had completely disappeared, and the plasma concentration was 2.55 times that at 12 h. Conclusion The gel beads containing ISL are a sustained, controlled, and colon-targeting delivery system that can alter the ISL distribution in the gastrointestinal tract.
- 5 July 2022
- Published by Springer Nature in European Journal of Drug Metabolism and Pharmacokinetics
- Vol. 47 (5) , 677-686
A pH/Time/Pectinase-Dependent Oral Colon-Targeted System Containing Isoliquiritigenin: Pharmacokinetics and Colon Targeting Evaluation in Mice
Background and Objectives Oral colon-targeted gel beads containing isoliquiritigenin (ISL) were successfully designed in our study. In order to further explore the targeting of the colon by the gel beads, a systematic study of their in vivo pharmacokinetics and colon targeting was performed in mice. Methods Eighteen male mice were included in this study. The mice were separated into six groups at random. We collected blood, stomach, duodenum, jejunum, ileum, and colon tissues at 2, 4, 6, 8, 12, and 24 h after oral administration of gel beads containing isoliquiritigenin at a dose of 20 mg/kg. Gel beads in tissues were recorded and taken out to observe their swelling and erosion. The total ISL concentrations in different tissues and gel beads were analyzed by high-performance liquid chromatography. Results All gel beads reached the upper part of the stomach at 2 h with no obvious swelling. Most of the gel beads were still in the lower part of stomach, while a small amount had reached the small intestine at 4 h. A few gel beads reached the colon and swelled at 6 h. Furthermore, the gel beads in the colon were swollen and erosive at 8 h. Meanwhile, the plasma ISL concentration could be detected, which indicated that the ISL in the gel beads was absorbed. At 12 h, the gel beads were almost dissolved and the plasma concentration was 8.33 times that at 8 h. At 24 h, the gel beads had completely disappeared, and the plasma concentration was 2.55 times that at 12 h. Conclusion The gel beads containing ISL are a sustained, controlled, and colon-targeting delivery system that can alter the ISL distribution in the gastrointestinal tract.
- 27 June 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1677, 463289
Study of the separation ability differences of three covalent organic frameworks as coated materials in capillary electrochromatography
- 27 June 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1677, 463289
Study of the separation ability differences of three covalent organic frameworks as coated materials in capillary electrochromatography
- 22 January 2021
- Published by Taylor & Francis in Journal of Biomolecular Structure and Dynamics
- Vol. 39 (2) , 672-680
Prediction of the inhibitory concentrations of chloroquine derivatives using deep neural networks models
In recent years, deep neural networks have begun to receive much attention, which has obvious advantages in feature extraction and modeling. However, in the using of deep neural networks for the QSAR modeling process, the selection of various parameters (number of neurons, hidden layers, transfer functions, data set partitioning, number of iterations, etc.) becomes difficult. Thus, we proposed a new and easy method for optimizing the model and selecting Deep Neural Networks (DNN) parameters through uniform design ideas and orthogonal design methods. By using this approach, 222 chloroquine (CQ) derivatives with half maximal inhibitory concentration values reported in different kinds of literature were selected to establish DNN models and a total number of 128,000 DNN models were built to determine the optimized parameters for selecting the better models. Comparing with linear and Artificial Neural Network (ANN) models, we found that DNN models showed better performance. Communicated by Ramaswamy H. Sarma
- 22 January 2021
- Published by Taylor & Francis in Journal of Biomolecular Structure and Dynamics
- Vol. 39 (2) , 672-680
Prediction of the inhibitory concentrations of chloroquine derivatives using deep neural networks models
In recent years, deep neural networks have begun to receive much attention, which has obvious advantages in feature extraction and modeling. However, in the using of deep neural networks for the QSAR modeling process, the selection of various parameters (number of neurons, hidden layers, transfer functions, data set partitioning, number of iterations, etc.) becomes difficult. Thus, we proposed a new and easy method for optimizing the model and selecting Deep Neural Networks (DNN) parameters through uniform design ideas and orthogonal design methods. By using this approach, 222 chloroquine (CQ) derivatives with half maximal inhibitory concentration values reported in different kinds of literature were selected to establish DNN models and a total number of 128,000 DNN models were built to determine the optimized parameters for selecting the better models. Comparing with linear and Artificial Neural Network (ANN) models, we found that DNN models showed better performance. Communicated by Ramaswamy H. Sarma
- 24 September 2019
- Published by Springer Nature in Archives of Toxicology
- Vol. 93 (11) , 3207-3218
In silico toxicity evaluation of dioxins using structure–activity relationship (SAR) and two-dimensional quantitative structure–activity relationship (2D-QSAR)
Prediction of pEC50 values of dioxins binding with the aryl hydrocarbon receptor (AhR) is of great significance for exploring how dioxins induce toxicity in human body and evaluating their environmental behaviors and risks. To reveal the factors that influence the toxicity of dioxins, provide more accurate mathematical models for predicting the pEC50 values of dioxins, and supplement the toxicity database of persistent organic pollutants, qualitative structure–activity relationship (SAR) and two-dimensional quantitative structure–activity relationship (2D-QSAR) were used in this study. The research objects in this study were 60 organic compounds with pEC50 values and 162 compounds without pEC50 values, which included polychlorinated dibenzofurans (PCDFs), polychlorinated dibenzo-p-dioxins (PCDDs), and polybrominated dibenzo-p-dioxins (PBDDs). The qualitative structure–activity relationship (SAR) was performed first and concluded that halogen substitutions at any of the 2, 3, 7, and 8 sites increased the pEC50 value of the compound. Moreover, two-dimensional quantitative structure–activity relationship (2D-QSAR) models were established by employing multiple linear regression (MLR) method and artificial neural network (ANN) algorithm to investigate the factors affecting the pEC50 values of dioxins molecules. MLR was used to establish the well-understood linear model and ANN was used to establish a more accurate non-linear model. Both models have good fitting, robustness, and predictive ability. Importantly, the ability of dioxins binding to AhR is mainly determined by molecular descriptors including E1m, SM09_AEA (dm), RDF065u, F05 [Cl–Cl], and Neoplastic-80. In addition, the pEC50 values of the 162 dioxins without toxicity data were predicted by MLR and ANN models, respectively.
- 24 September 2019
- Published by Springer Nature in Archives of Toxicology
- Vol. 93 (11) , 3207-3218
In silico toxicity evaluation of dioxins using structure–activity relationship (SAR) and two-dimensional quantitative structure–activity relationship (2D-QSAR)
Prediction of pEC50 values of dioxins binding with the aryl hydrocarbon receptor (AhR) is of great significance for exploring how dioxins induce toxicity in human body and evaluating their environmental behaviors and risks. To reveal the factors that influence the toxicity of dioxins, provide more accurate mathematical models for predicting the pEC50 values of dioxins, and supplement the toxicity database of persistent organic pollutants, qualitative structure–activity relationship (SAR) and two-dimensional quantitative structure–activity relationship (2D-QSAR) were used in this study. The research objects in this study were 60 organic compounds with pEC50 values and 162 compounds without pEC50 values, which included polychlorinated dibenzofurans (PCDFs), polychlorinated dibenzo-p-dioxins (PCDDs), and polybrominated dibenzo-p-dioxins (PBDDs). The qualitative structure–activity relationship (SAR) was performed first and concluded that halogen substitutions at any of the 2, 3, 7, and 8 sites increased the pEC50 value of the compound. Moreover, two-dimensional quantitative structure–activity relationship (2D-QSAR) models were established by employing multiple linear regression (MLR) method and artificial neural network (ANN) algorithm to investigate the factors affecting the pEC50 values of dioxins molecules. MLR was used to establish the well-understood linear model and ANN was used to establish a more accurate non-linear model. Both models have good fitting, robustness, and predictive ability. Importantly, the ability of dioxins binding to AhR is mainly determined by molecular descriptors including E1m, SM09_AEA (dm), RDF065u, F05 [Cl–Cl], and Neoplastic-80. In addition, the pEC50 values of the 162 dioxins without toxicity data were predicted by MLR and ANN models, respectively.