Katri Kuningas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Katri Kuningas has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Terhi Rantanen
Department of Biotechnology, University of Turku, Turku, Finland
5 shared publicationsTero Soukka
Department of Biotechnology, University of Turku, Turku, Finland
5 shared publicationsTimo Lövgren
Department of Biotechnology, University of Turku, Tykistökatu 6A, FIN-20520 Turku, Finland
4 shared publicationsTelle Ukonaho
Department of Biotechnology, University of Turku, Turku, Finland
3 shared publicationsHenna PäkKilä
Department of Biotechnology, University of Turku, Turku, Finland
1 shared publicationHenna Päkkilä
Department of Biotechnology, University of Turku, Tykistökatu 6A, FIN-20520 Turku, Finland
1 shared publication
Latest Publications
- Open Access
- 1 January 2007
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 53 (1) , 145-146
Upconversion Fluorescence Enables Homogeneous Immunoassay in Whole Blood
Many medical conditions are related to alterations in protein or hormone concentrations in blood. These changes are commonly detected with heterogeneous immunoa
- 1 January 2007
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 53 (1) , 145-146
Open AccessUpconversion Fluorescence Enables Homogeneous Immunoassay in Whole Blood
Many medical conditions are related to alterations in protein or hormone concentrations in blood. These changes are commonly detected with heterogeneous immunoa
- 17 May 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (13) , 4690-4696
Upconversion Fluorescence Resonance Energy Transfer in a Homogeneous Immunoassay for Estradiol
We recently described a novel homogeneous assay principle based on upconversion fluorescence resonance energy transfer (UC-FRET), where an upconverting phosphor (UCP) is utilized as a donor. The UC-FRET has now been applied to a competitive homogeneous immunoassay for 17β-estradiol (E2) in serum, using a small-molecular dye as an acceptor. The assay was constructed by employing an UCP coated with an E2-specific recombinant antibody Fab fragment as a donor and an E2-conjugated small-molecular dye, Oyster-556, as an acceptor. Standard curves for the assay were produced both in buffer and in male serum. Sensitized acceptor emission was measured at 600 nm under continuous laser diode excitation at 980 nm. In buffer, the IC50 value of the assay was 1 nM and in serum 3 nM. The lower limits of detection (mean of zero calibrators, 3 SD) were 0.4 and 0.9 nM, respectively. The measurable concentration range extended up to 3 nM in buffer and 9 nM in serum. Equilibrium in the assay was reached in 30 min. The novel principle of UC-FRET has unique advantages compared to present homogeneous luminescence-based methods and can enable an attractive assay system platform for clinical diagnostics and for high-throughput screening approaches.
- 17 May 2006
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 78 (13) , 4690-4696
Upconversion Fluorescence Resonance Energy Transfer in a Homogeneous Immunoassay for Estradiol
We recently described a novel homogeneous assay principle based on upconversion fluorescence resonance energy transfer (UC-FRET), where an upconverting phosphor (UCP) is utilized as a donor. The UC-FRET has now been applied to a competitive homogeneous immunoassay for 17β-estradiol (E2) in serum, using a small-molecular dye as an acceptor. The assay was constructed by employing an UCP coated with an E2-specific recombinant antibody Fab fragment as a donor and an E2-conjugated small-molecular dye, Oyster-556, as an acceptor. Standard curves for the assay were produced both in buffer and in male serum. Sensitized acceptor emission was measured at 600 nm under continuous laser diode excitation at 980 nm. In buffer, the IC50 value of the assay was 1 nM and in serum 3 nM. The lower limits of detection (mean of zero calibrators, 3 SD) were 0.4 and 0.9 nM, respectively. The measurable concentration range extended up to 3 nM in buffer and 9 nM in serum. Equilibrium in the assay was reached in 30 min. The novel principle of UC-FRET has unique advantages compared to present homogeneous luminescence-based methods and can enable an attractive assay system platform for clinical diagnostics and for high-throughput screening approaches.
- 6 October 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (22) , 7348-7355
Homogeneous Assay Technology Based on Upconverting Phosphors
Upconversion photoluminescence can eliminate problems associated with autofluorescence and scattered excitation light in homogeneous luminescence-based assays without need for temporal resolution. We have demonstrated a luminescence resonance energy-transfer-based assay utilizing inorganic upconverting (UPC) lanthanide phosphor as a donor and fluorescent protein as an acceptor. UPC phosphors are excited at near-infrared and they have narrow-banded anti-Stokes emission at visible wavelengths enabling measurement of the proximity-dependent sensitized emission with minimal background. The acceptor alone does not generate any direct emission at shorter wavelengths under near-infrared excitation. A competitive model assay for biotin was constructed using streptavidin-conjugated Er3+,Yb3+-doped UPC phosphor as a donor and biotinylated phycobiliprotein as an acceptor. UPC phosphor was excited at near-infrared (980 nm) and sensitized acceptor emission was measured at red wavelength (600 nm) by using a microtitration plate fluorometer equipped with an infrared laser diode and suitable excitation and emission filters. Lower limit of detection was in the subnanomolar concentration range. Compared to time-resolved fluorometry, the developed assay technology enabled simplified instrumentation. Excitation at near-infrared and emission at red wavelengths render the technology also suitable to analysis of strongly colored and fluorescent samples, which are often of concern in clinical immunoassays and in high-throughput screening.
- 6 October 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (22) , 7348-7355
Homogeneous Assay Technology Based on Upconverting Phosphors
Upconversion photoluminescence can eliminate problems associated with autofluorescence and scattered excitation light in homogeneous luminescence-based assays without need for temporal resolution. We have demonstrated a luminescence resonance energy-transfer-based assay utilizing inorganic upconverting (UPC) lanthanide phosphor as a donor and fluorescent protein as an acceptor. UPC phosphors are excited at near-infrared and they have narrow-banded anti-Stokes emission at visible wavelengths enabling measurement of the proximity-dependent sensitized emission with minimal background. The acceptor alone does not generate any direct emission at shorter wavelengths under near-infrared excitation. A competitive model assay for biotin was constructed using streptavidin-conjugated Er3+,Yb3+-doped UPC phosphor as a donor and biotinylated phycobiliprotein as an acceptor. UPC phosphor was excited at near-infrared (980 nm) and sensitized acceptor emission was measured at red wavelength (600 nm) by using a microtitration plate fluorometer equipped with an infrared laser diode and suitable excitation and emission filters. Lower limit of detection was in the subnanomolar concentration range. Compared to time-resolved fluorometry, the developed assay technology enabled simplified instrumentation. Excitation at near-infrared and emission at red wavelengths render the technology also suitable to analysis of strongly colored and fluorescent samples, which are often of concern in clinical immunoassays and in high-throughput screening.
- 6 July 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 543 (1-2) , 130-136
Enhanced photoluminescence of up-converting phosphors in a solid phase bioaffinity assay
- 6 July 2005
- Published by Elsevier in Analytica Chimica Acta
- Vol. 543 (1-2) , 130-136
Enhanced photoluminescence of up-converting phosphors in a solid phase bioaffinity assay
- 24 March 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (9) , 2826-2834
Simultaneous Use of Time-Resolved Fluorescence and Anti-Stokes Photoluminescence in a Bioaffinity Assay
A bioaffinity assay is described where anti-Stokes photoluminescence of inorganic lanthanide phosphors and time-resolved fluorescence of lanthanide chelates are measured from a single microtitration well without any disturbance from these label technologies to each other. Up-converting phosphor (UPC-phosphor) bioconjugate was produced by grinding the commercial, micrometer-sized UPC-phosphors to colloidal, submicrometer-sized phosphor particles and by attaching these phosphors to biomolecules. Experiments were carried out in standard 96-well microtitration plates to determine detection limits, linearity, and cross-talk of UPC-phosphor and europium chelate. In numbers of molecules the lower limits of detection for UPC-phosphor were roughly 3 x 10(3) particles in solution and 1 x 10(4) particles in solid phase, and for europium label same values were 9 x 10(6) and 9 x 10(7) molecules. Linearity of detection was for UPC-phosphor 5 orders of magnitude in solution and over 4 orders of magnitude in solid phase and for europium label over 5 orders of magnitude in solution and over 4 orders of magnitude in solid phase. The cross-talk between the two labels was practically nonexistent. In this study we show that up-converting anti-Stokes photoluminescent phosphors could be employed in bioaffinity assays as very potential labels with significant advantages either alone or together with long-lifetime lanthanide chelates.
- 24 March 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (9) , 2826-2834
Simultaneous Use of Time-Resolved Fluorescence and Anti-Stokes Photoluminescence in a Bioaffinity Assay
A bioaffinity assay is described where anti-Stokes photoluminescence of inorganic lanthanide phosphors and time-resolved fluorescence of lanthanide chelates are measured from a single microtitration well without any disturbance from these label technologies to each other. Up-converting phosphor (UPC-phosphor) bioconjugate was produced by grinding the commercial, micrometer-sized UPC-phosphors to colloidal, submicrometer-sized phosphor particles and by attaching these phosphors to biomolecules. Experiments were carried out in standard 96-well microtitration plates to determine detection limits, linearity, and cross-talk of UPC-phosphor and europium chelate. In numbers of molecules the lower limits of detection for UPC-phosphor were roughly 3 x 10(3) particles in solution and 1 x 10(4) particles in solid phase, and for europium label same values were 9 x 10(6) and 9 x 10(7) molecules. Linearity of detection was for UPC-phosphor 5 orders of magnitude in solution and over 4 orders of magnitude in solid phase and for europium label over 5 orders of magnitude in solution and over 4 orders of magnitude in solid phase. The cross-talk between the two labels was practically nonexistent. In this study we show that up-converting anti-Stokes photoluminescent phosphors could be employed in bioaffinity assays as very potential labels with significant advantages either alone or together with long-lifetime lanthanide chelates.