Charles J. Davidson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Charles J. Davidson has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Andy Adam
2 shared publicationsChetan Huded
1 shared publicationChristoph R. Becker
1 shared publication- Christoph R. Becker
Institute of Radiologic Diagnostic, University of Munich, Klinikum Grosshadern, Marchioninistrasse 15, 81377 Munich, Germany
1 shared publication Cin Consensus Working Panel
1 shared publicationFulvio Stacul
1 shared publication
Latest Publications
- 1 September 2006
- Published by Elsevier in The American Journal of Cardiology
- Vol. 98 (6) , 42-58
Contrast Medium Use
- 1 September 2006
- Published by Elsevier in The American Journal of Cardiology
- Vol. 98 (6) , 42-58
Contrast Medium Use
- 1 January 2006
- Vol. 7 (4) , 177-97
Contrast-Induced Nephropathy (CIN) Consensus Working Panel: executive summary.
With the advances made in radiology and cardiology, greater numbers of patients are expected to undergo exposure to iodinated contrast media in the years to come. Contrast-induced nephropathy (CIN) accounts for a significant number of cases of hospital-acquired renal failure, with adverse effects on prognosis and healthcare costs. The CIN Consensus Working Panel is an international multidisciplinary group convened to address the challenges of CIN. The group reviewed 865 published papers, chosen for potential relevance from a comprehensive literature search that identified over 4000 references. The results were used to compile reviews covering the epidemiology and pathogenesis of CIN, baseline renal function measurement, risk assessment, identification of high-risk patients, contrast medium use, and preventive strategies. In this executive summary, consensus statements and an algorithm for the risk stratification and management of CIN are presented.
- 1 January 2006
- Vol. 7 (4) , 177-97
Contrast-Induced Nephropathy (CIN) Consensus Working Panel: executive summary.
With the advances made in radiology and cardiology, greater numbers of patients are expected to undergo exposure to iodinated contrast media in the years to come. Contrast-induced nephropathy (CIN) accounts for a significant number of cases of hospital-acquired renal failure, with adverse effects on prognosis and healthcare costs. The CIN Consensus Working Panel is an international multidisciplinary group convened to address the challenges of CIN. The group reviewed 865 published papers, chosen for potential relevance from a comprehensive literature search that identified over 4000 references. The results were used to compile reviews covering the epidemiology and pathogenesis of CIN, baseline renal function measurement, risk assessment, identification of high-risk patients, contrast medium use, and preventive strategies. In this executive summary, consensus statements and an algorithm for the risk stratification and management of CIN are presented.
- 1 February 2003
- Vol. 15 (2) , 68-70
A comparison of arterial closure devices to manual compression in liver transplantation candidates undergoing coronary angiography.
Whether arterial closure devices can be used safely in a coagulopathic population undergoing cardiac catheterization and at high risk for groin complications, such as liver transplant candidates, is unknown. In this prospective, non-randomized consecutive series of 80 liver transplant candidates undergoing coronary angiography, manual compression and arterial closure devices were compared. Ilio-femoral angiography was performed to determine suitability for use of the closure device. Bleeding and vascular complications were recorded along with time to ambulation. Arterial closure devices were used in 31 patients (39%), whereas manual compression was used in 49 patients (50 procedures) (61%). There were no significant differences between the two groups with respect to age, sex, cardiac risk factors, peripheral vascular disease, baseline platelet count or baseline INR. There were 10 total vascular complications out of 50 procedures (20%) in the manual compression group compared to 2 vascular complications out of 31 procedures in the arterial closure device group (6%; p = 0.12). The time to ambulation was significantly less in the group receiving arterial closure devices versus manual compression (4.2 1.8 hours versus 6.6 3.7 hours, respectively; p = 0.0003). In coagulopathic patients at higher risk for groin complications, arterial closure devices can be safely used and decrease time to ambulation compared to manual compression.
- 1 February 2003
- Vol. 15 (2) , 68-70
A comparison of arterial closure devices to manual compression in liver transplantation candidates undergoing coronary angiography.
Whether arterial closure devices can be used safely in a coagulopathic population undergoing cardiac catheterization and at high risk for groin complications, such as liver transplant candidates, is unknown. In this prospective, non-randomized consecutive series of 80 liver transplant candidates undergoing coronary angiography, manual compression and arterial closure devices were compared. Ilio-femoral angiography was performed to determine suitability for use of the closure device. Bleeding and vascular complications were recorded along with time to ambulation. Arterial closure devices were used in 31 patients (39%), whereas manual compression was used in 49 patients (50 procedures) (61%). There were no significant differences between the two groups with respect to age, sex, cardiac risk factors, peripheral vascular disease, baseline platelet count or baseline INR. There were 10 total vascular complications out of 50 procedures (20%) in the manual compression group compared to 2 vascular complications out of 31 procedures in the arterial closure device group (6%; p = 0.12). The time to ambulation was significantly less in the group receiving arterial closure devices versus manual compression (4.2 1.8 hours versus 6.6 3.7 hours, respectively; p = 0.0003). In coagulopathic patients at higher risk for groin complications, arterial closure devices can be safely used and decrease time to ambulation compared to manual compression.