Sadao Nakamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sadao Nakamura has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Shigeki Daishima
Agilent Technologies Japan, Ltd. Chemical Analysis Group
9 shared publicationsMasahiko Takino
Yokogawa Analytical Systems Inc., 2-11-13 Nakacho, Musashino-shi, Tokyo, Japan
2 shared publicationsSatoshi Ito
Yokogawa Analytical Systems Inc., 2‐11‐13 Nakacho, Musashino‐shi, Tokyo 180–0006, Japan; Fax: +81‐422‐52‐5966
2 shared publicationsAkira Tsuji
Yokogawa Analytical Systems, Hachioji‐shi, Tokyo, Japan. Fax: +81‐426‐60‐9712
1 shared publicationChuichi Watanabe
1 shared publicationKenichi Toubou
Shinkawa Electric Co., Ltd
1 shared publication
Latest Publications
- 1 January 2013
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 62 (3) , 229-241
Multi-residue Analysis of Pesticides in Agricultural Products by GC/MS Using Synchronous SIM/Scan Acquisition
- 1 January 2013
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 62 (3) , 229-241
Multi-residue Analysis of Pesticides in Agricultural Products by GC/MS Using Synchronous SIM/Scan Acquisition
- 1 January 2013
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 62 (3) , 215-221
Simultaneous Determination of 1,4-dioxane, Epichlorohydrin, 2-methylisoborneol and Geosmin in Water by Headspace Solid-phase Microextraction/GC/MS
- 1 January 2013
- Published by Japan Society for Analytical Chemistry in BUNSEKI KAGAKU
- Vol. 62 (3) , 215-221
Simultaneous Determination of 1,4-dioxane, Epichlorohydrin, 2-methylisoborneol and Geosmin in Water by Headspace Solid-phase Microextraction/GC/MS
- 7 December 2005
- Published by Wiley in Journal of Separation Science
- Vol. 28 (18) , 2511-2516
Determination of 2‐methylisoborneol and geosmin in aqueous samples by static headspace‐gas chromatography‐mass spectrometry with ramped inlet pressure
A method for determining the earthy and musty odors 2‐methylisoborneol (2‐MIB) and geosmin in drinking water using static headspace‐GC‐MS is described. To achieve lower detection limits, split ratio was optimized with ramped inlet pressure for large headspace sampling volume. The ramped inlet pressure, which held higher pressure (higher column flow rate) only during injection, allowed us to inject 3‐mL volume to GC with very low split ratio (2:1). Although sequential analysis with a stainless steel ion source often changed the mass spectrum of 2‐MIB, this spectral change was eliminated by using an inert ion source with a 6 mm drawout plate. The detection limits of this method were 0.36 and 0.14 ng/L, respectively, for 2‐MIB and geosmin. The repeatabilities (n = 30) were 6.6 and 4.8%, respectively, at 1 ng/L for 2‐MIB and geosmin.
- 7 December 2005
- Published by Wiley in Journal of Separation Science
- Vol. 28 (18) , 2511-2516
Determination of 2‐methylisoborneol and geosmin in aqueous samples by static headspace‐gas chromatography‐mass spectrometry with ramped inlet pressure
A method for determining the earthy and musty odors 2‐methylisoborneol (2‐MIB) and geosmin in drinking water using static headspace‐GC‐MS is described. To achieve lower detection limits, split ratio was optimized with ramped inlet pressure for large headspace sampling volume. The ramped inlet pressure, which held higher pressure (higher column flow rate) only during injection, allowed us to inject 3‐mL volume to GC with very low split ratio (2:1). Although sequential analysis with a stainless steel ion source often changed the mass spectrum of 2‐MIB, this spectral change was eliminated by using an inert ion source with a 6 mm drawout plate. The detection limits of this method were 0.36 and 0.14 ng/L, respectively, for 2‐MIB and geosmin. The repeatabilities (n = 30) were 6.6 and 4.8%, respectively, at 1 ng/L for 2‐MIB and geosmin.
- 27 April 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (1) , 99-107
Simultaneous determination of 64 pesticides in river water by stir bar sorptive extraction and thermal desorption-gas chromatography-mass spectrometry
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively.
- 27 April 2005
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 382 (1) , 99-107
Simultaneous determination of 64 pesticides in river water by stir bar sorptive extraction and thermal desorption-gas chromatography-mass spectrometry
A method for determining 68 pesticides in river water using stir bar sorptive extraction (SBSE)-thermal desorption (TD)-gas chromatography-mass spectrometry (GC-MS) is described. SBSE sampling was optimized for sample solution pH, salting-out and methanol addition. Although salting-out enhanced the ability of the method to extract most of the pesticides with low absolute recoveries, the absolute recoveries of four pesticides were not improved by salting-out. The detection limits of the method for the pesticides ranged from 0.2 to 20 ng/l. Analyte recoveries from a river water sample spiked with standards at 10 and 100 ng/l were 58.5–132.0% (RSD: 1.8–15.8%) and 61.0–121.3% (RSD: 1.4–20.2%), respectively.
- 1 August 2001
- Published by Wiley in Journal of Separation Science
- Vol. 24 (8) , 674-677
Determination of 2-methylisoborneol and geosmin in water by gas chromatography-mass spectrometry using stir bar sorptive extraction
- 1 August 2001
- Published by Wiley in Journal of Separation Science
- Vol. 24 (8) , 674-677
Determination of 2-methylisoborneol and geosmin in water by gas chromatography-mass spectrometry using stir bar sorptive extraction
- 1 June 2001
- Published by Elsevier in Journal of Chromatography A
- Vol. 919 (2) , 275-282
Determination of estrogens in river water by gas chromatography–negative-ion chemical-ionization mass spectrometry
- 1 June 2001
- Published by Elsevier in Journal of Chromatography A
- Vol. 919 (2) , 275-282
Determination of estrogens in river water by gas chromatography–negative-ion chemical-ionization mass spectrometry
- 23 May 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (6) , 835-839
Trace level determination of phenols as pentafluorobenzyl derivatives by gas chromatography - negative-ion chemical ionization mass spectrometry
A method for the trace level determination of 11 phenols as pentafluorobenzyl (PFB) derivatives by gas chromatography–mass spectrometry (GC-MS) with negative-ion chemical ionization (NICI) is described. First, the conditions for the PFB derivatisation of phenols were optimized and were found to be reaction temperature 80 °C and reaction time 5 h. Second, the detection limits using selected ion monitoring (SIM) were compared between trimethylsilylated (TMS) derivatives in the electron ionization (EI) mode and PFB derivatives in the NICI mode. The responses for the PFB derivatives in the NICI mode were 3.3–61 times higher than those of the TMS derivatives in the EI mode. The instrumental detection limits using NICI-SIM ranged from 2.6 to 290 fg. This method was applied to the analysis of phenols in river water using solid-phase extraction. The recoveries of the phenols from a river water sample spiked with standards at 100 ng l−1 with 2-chlorophenol, 4-chloro-3-methylphenol and pentachlorophenol and at 1000 ng l−1 with phenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 2-nitrophenol, 2,4,6-trichlorophenol and 4-nitrophenol were 81.2–106.3% (RSD 5.1–8.0%), except for 2-methyl-4,6-dinitrophenol and 2,4-dinitrophenol, for which the recoveries were 5.8 and 4.2%, respectively, because water contained in the acetone eluate interfered with the derivatisation of these compounds with two electrophilic nitro groups.
- 23 May 2001
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 126 (6) , 835-839
Trace level determination of phenols as pentafluorobenzyl derivatives by gas chromatography - negative-ion chemical ionization mass spectrometry
A method for the trace level determination of 11 phenols as pentafluorobenzyl (PFB) derivatives by gas chromatography–mass spectrometry (GC-MS) with negative-ion chemical ionization (NICI) is described. First, the conditions for the PFB derivatisation of phenols were optimized and were found to be reaction temperature 80 °C and reaction time 5 h. Second, the detection limits using selected ion monitoring (SIM) were compared between trimethylsilylated (TMS) derivatives in the electron ionization (EI) mode and PFB derivatives in the NICI mode. The responses for the PFB derivatives in the NICI mode were 3.3–61 times higher than those of the TMS derivatives in the EI mode. The instrumental detection limits using NICI-SIM ranged from 2.6 to 290 fg. This method was applied to the analysis of phenols in river water using solid-phase extraction. The recoveries of the phenols from a river water sample spiked with standards at 100 ng l−1 with 2-chlorophenol, 4-chloro-3-methylphenol and pentachlorophenol and at 1000 ng l−1 with phenol, 2,4-dimethylphenol, 2,4-dichlorophenol, 2-nitrophenol, 2,4,6-trichlorophenol and 4-nitrophenol were 81.2–106.3% (RSD 5.1–8.0%), except for 2-methyl-4,6-dinitrophenol and 2,4-dinitrophenol, for which the recoveries were 5.8 and 4.2%, respectively, because water contained in the acetone eluate interfered with the derivatisation of these compounds with two electrophilic nitro groups.
- 20 March 2001
- Published by Elsevier in Journal of Chromatography A
- Vol. 912 (2) , 329-334
Analysis of waterborne paints by gas chromatography–mass spectrometry with a temperature-programmable pyrolyzer
- 20 March 2001
- Published by Elsevier in Journal of Chromatography A
- Vol. 912 (2) , 329-334
Analysis of waterborne paints by gas chromatography–mass spectrometry with a temperature-programmable pyrolyzer
- 1 January 1998
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 46 (4) , 336-341
Analysis of Vulcanization Accelerator in Vulcanized Rubber by Thermal Desorption/Pyrolysis-GC/AED and MS.
- 1 January 1998
- Published by The Mass Spectrometry Society of Japan in Journal of the Mass Spectrometry Society of Japan
- Vol. 46 (4) , 336-341
Analysis of Vulcanization Accelerator in Vulcanized Rubber by Thermal Desorption/Pyrolysis-GC/AED and MS.